Flow calculation : TestRslt.FlowVolume is always the most accurate CTV flow (calculated from the measured mass in case of mass collection methods)
This commit is contained in:
+9
-8
@@ -945,21 +945,22 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollDeferredEval
|
||||
tstRslt.MassEndRaw = EndMass.Val;
|
||||
tstRslt.MassEnd = massEnd;
|
||||
tstRslt.FlowMass = 3600.0 * (tstRslt.MassEnd - tstRslt.MassStart + massOfEvaporatedWater) / tstRslt.TestTime; /// [kg/h]
|
||||
tstRslt.FlowVolume = 3.6 * LtrPerRefPulse * tstRslt.PulsesMaster / tstRslt.TestTime; /// [m3/h]
|
||||
tstRslt.VolumeMaster = LtrPerRefPulse * tstRslt.PulsesMaster; /// [l] volume from the master flow meter
|
||||
double flow = 3.6 * LtrPerRefPulse * tstRslt.PulsesMaster / tstRslt.TestTime; /// [m3/h]
|
||||
tstRslt.VolumeMaster = LtrPerRefPulse * tstRslt.PulsesMaster; /// [l] volume from the master flow meter
|
||||
tstRslt.Buoyancy = buoyancy;
|
||||
tstRslt.VolumeCTV = volumeCTV; /// [l] 1000.0f is because density is in [kg/m3]
|
||||
tstRslt.ConstMasterRaw = outPath.FlowMeter.LtrPerPulse; /// Uncorrected master flowmeter coefficient
|
||||
tstRslt.ConstMasterCorr = outPath.FlowMeter.LtrPerPulseCorrected(tstRslt.FlowVolume, rangeIx); /// Corrected master pulses per liter
|
||||
tstRslt.ConstMasterCorr = outPath.FlowMeter.LtrPerPulseCorrected(flow, rangeIx); /// Corrected master pulses per liter
|
||||
tstRslt.ConstMaster = (tstRslt.VolumeMaster == 0) ? tstRslt.ConstMasterCorr : (LtrPerRefPulse * tstRslt.VolumeCTV / tstRslt.VolumeMaster);
|
||||
/// Calculated master pulses per liter
|
||||
tstRslt.ErrorMaster = Config.Formulas.ErrorFromVolumes(tstRslt.VolumeMaster, tstRslt.VolumeCTV);
|
||||
|
||||
tstRslt.FlowMean = (float)RefFlowStat.Average;
|
||||
tstRslt.FlowStart = (float)RefFlowStat.First;
|
||||
tstRslt.FlowEnd = (float)RefFlowStat.Last;
|
||||
tstRslt.FlowMin = (float)RefFlowStat.Min;
|
||||
tstRslt.FlowMax = (float)RefFlowStat.Max;
|
||||
tstRslt.FlowVolume = 3.6 * tstRslt.VolumeCTV / tstRslt.TestTime;
|
||||
tstRslt.FlowMean = Convert.ToSingle(RefFlowStat.Average);
|
||||
tstRslt.FlowStart = Convert.ToSingle(RefFlowStat.First);
|
||||
tstRslt.FlowEnd = Convert.ToSingle(RefFlowStat.Last);
|
||||
tstRslt.FlowMin = Convert.ToSingle(RefFlowStat.Min);
|
||||
tstRslt.FlowMax = Convert.ToSingle(RefFlowStat.Max);
|
||||
|
||||
tstRslt.DiverterStart = switchTimeStart;
|
||||
tstRslt.DiverterEnd = switchTimeEnd;
|
||||
|
||||
Reference in New Issue
Block a user