(1) formated date/time information in output items, (2) support for two printers and four file writers in procedure spec.
This commit is contained in:
@@ -110,9 +110,11 @@ namespace Results
|
||||
AllItems.Add(new WMeterRsltItemSpec(11, "Uncertainty", (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : w.GetTestRslt(t).Uncertainty().ToString(string.IsNullOrEmpty(p) ? "F2" : p)));
|
||||
|
||||
/// Test results
|
||||
AllItems.Add(new WMeterRsltItemSpec(12, "Test start time", (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : w.GetTestRslt(t).StartTime.ToShortTimeString()));
|
||||
AllItems.Add(new WMeterRsltItemSpec(13, "Test end time", (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : w.GetTestRslt(t).EndTime.ToShortTimeString()));
|
||||
AllItems.Add(new WMeterRsltItemSpec(14, "Test time", (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : w.GetTestRslt(t).TestTime.ToString(string.IsNullOrEmpty(p) ? "F2" : p)));
|
||||
AllItems.Add(new WMeterRsltItemSpec(12, "Test start date/time", (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : (string.IsNullOrEmpty(p) ? w.GetTestRslt(t).StartTime.ToShortTimeString()
|
||||
: w.GetTestRslt(t).StartTime.ToString(p))));
|
||||
AllItems.Add(new WMeterRsltItemSpec(13, "Test end date/time", (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : (string.IsNullOrEmpty(p) ? w.GetTestRslt(t).EndTime.ToShortTimeString()
|
||||
: w.GetTestRslt(t).EndTime.ToString(p))));
|
||||
AllItems.Add(new WMeterRsltItemSpec(14, "Test time", (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : w.GetTestRslt(t).TestTime.ToString(string.IsNullOrEmpty(p) ? "F2" : p)));
|
||||
AllItems.Add(new WMeterRsltItemSpec(15, "Flow", (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Utils.DoubleToStr(Config.Units.ConvertTo(u, w.GetTestRslt(t).FlowVolume), 4)));
|
||||
AllItems.Add(new WMeterRsltItemSpec(16, "T in", (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetTestRslt(t).TempInAvrg).ToString(string.IsNullOrEmpty(p) ? "F2" : p)));
|
||||
AllItems.Add(new WMeterRsltItemSpec(17, "T out", (w, t, u, f, p) => (w.GetTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetTestRslt(t).TempOutAvrg).ToString(string.IsNullOrEmpty(p) ? "F2" : p)));
|
||||
@@ -170,10 +172,10 @@ namespace Results
|
||||
AllItems.Add(new WMeterRsltItemSpec(54, "Procedure name", (w, t, u, f, p) => w.Batch.ProcedureName));
|
||||
AllItems.Add(new WMeterRsltItemSpec(55, "Watermeters", (w, t, u, f, p) => w.Batch.WatermetersStr));
|
||||
AllItems.Add(new WMeterRsltItemSpec(56, "Protocol title", (w, t, u, f, p) => w.Batch.ProtocolTitle));
|
||||
AllItems.Add(new WMeterRsltItemSpec(57, "Batch start time", (w, t, u, f, p) => w.Batch.StartTime.ToShortTimeString()));
|
||||
AllItems.Add(new WMeterRsltItemSpec(58, "Batch end time", (w, t, u, f, p) => w.Batch.EndTime.ToShortTimeString()));
|
||||
AllItems.Add(new WMeterRsltItemSpec(59, "Batch start date", (w, t, u, f, p) => w.Batch.StartTime.ToShortDateString()));
|
||||
AllItems.Add(new WMeterRsltItemSpec(60, "Batch end date", (w, t, u, f, p) => w.Batch.EndTime.ToShortDateString()));
|
||||
AllItems.Add(new WMeterRsltItemSpec(57, "Batch start date/time",(w, t, u, f, p) => (string.IsNullOrEmpty(p) ? w.Batch.StartTime.ToShortDateString()
|
||||
: w.Batch.StartTime.ToString(p))));
|
||||
AllItems.Add(new WMeterRsltItemSpec(58, "Batch end date/time", (w, t, u, f, p) => (string.IsNullOrEmpty(p) ? w.Batch.EndTime.ToShortDateString()
|
||||
: w.Batch.EndTime.ToString(p))));
|
||||
}
|
||||
|
||||