Ambient clean-up.
This commit is contained in:
@@ -22,7 +22,7 @@ namespace TBF.Rig.Ambient.Greco
|
||||
public class Ambient : ComponentBase, IDevice, IOperation, GenericDevices.IAmbient, IDrawingItCmpntWithMeasuredVal
|
||||
{
|
||||
private static readonly ILog log = LogManager.GetLogger(typeof(Ambient));
|
||||
public override string ToString() { return string.Format("Ambient({0})", Cfg.ToString(-1)); }
|
||||
public override string ToString() { return string.Format("{0}({1})", ClassName, Cfg.ToString(-1)); }
|
||||
|
||||
private readonly AmbientCfg ambientCfg;
|
||||
///
|
||||
@@ -49,7 +49,8 @@ namespace TBF.Rig.Ambient.Greco
|
||||
public double MeasuredVal { get { return temperature; } }
|
||||
public string AltString
|
||||
{
|
||||
get {
|
||||
get
|
||||
{
|
||||
return string.Format(ambientCfg.Format, Units.ConvertTo(TempUnit, temperature),
|
||||
Units.ConvertTo(PressureUnit, pressure),
|
||||
Units.ConvertTo(HumiUnit, humidity));
|
||||
@@ -60,9 +61,6 @@ namespace TBF.Rig.Ambient.Greco
|
||||
SerialPort serialPort;
|
||||
StringBuilder measurementBuilder;
|
||||
|
||||
/// <summary>The state of the measurement</summary>
|
||||
MsrmntState msrmntState;
|
||||
|
||||
///
|
||||
/// Measured values when MsrmntState == MsrmntState.Valid
|
||||
///
|
||||
@@ -73,48 +71,41 @@ namespace TBF.Rig.Ambient.Greco
|
||||
/// <summary>Measurement time stamp when MsrmntState == MsrmntState.Valid</summary>
|
||||
int msrmntTimeStamp;
|
||||
|
||||
public Ambient()
|
||||
{
|
||||
}
|
||||
|
||||
public Ambient() { }
|
||||
|
||||
/// <summary>
|
||||
/// Ambient temperature / humidity / pressure meter 'Greco' connected via serial interface (RS232)
|
||||
/// Connection settings: 19200 Bd 8-bits No-parity 1-stop-bit Flow control: none or hardware.
|
||||
/// </summary>
|
||||
public Ambient(AmbientCfg cfg, IList<Generic.IComponent> components)
|
||||
: this(cfg)
|
||||
{
|
||||
}
|
||||
|
||||
public Ambient(Generic.IComponentCfg cfg)
|
||||
public Ambient(Generic.IComponentCfg cfg)
|
||||
: base(cfg)
|
||||
{
|
||||
ambientCfg = cfg as AmbientCfg;
|
||||
|
||||
temperature = DefaultTemperature;
|
||||
pressure = DefaultPressure;
|
||||
humidity = DefaultHumidity;
|
||||
|
||||
log.Warn(this.ToString());
|
||||
}
|
||||
|
||||
public void Initialize()
|
||||
{
|
||||
if (ambientCfg.DebugLevel == DebugMode.Simulate)
|
||||
{
|
||||
msrmntTimeStamp = StateMachine.Time;
|
||||
msrmntState = MsrmntState.Valid;
|
||||
return;
|
||||
}
|
||||
temperature = DefaultTemperature;
|
||||
pressure = DefaultPressure;
|
||||
humidity = DefaultHumidity;
|
||||
msrmntTimeStamp = 0;
|
||||
|
||||
string comPortName = "COM" + ambientCfg.ComPortNr.ToString();
|
||||
serialPort = new SerialPort(comPortName, ambientCfg.BaudRate, ambientCfg.Parity, ambientCfg.DataBits, ambientCfg.StopBits);
|
||||
serialPort.Handshake = ambientCfg.Handshake;
|
||||
serialPort.Open();
|
||||
measurementBuilder = new StringBuilder(40);
|
||||
msrmntState = MsrmntState.Busy;
|
||||
|
||||
log.FatalFormat("Successfully initialized device {0}", ToString());
|
||||
if (ambientCfg.DebugLevel == DebugMode.Normal)
|
||||
{
|
||||
string comPortName = "COM" + ambientCfg.ComPortNr.ToString();
|
||||
serialPort = new SerialPort(comPortName, ambientCfg.BaudRate, ambientCfg.Parity, ambientCfg.DataBits, ambientCfg.StopBits);
|
||||
serialPort.Handshake = ambientCfg.Handshake;
|
||||
serialPort.Open();
|
||||
measurementBuilder = new StringBuilder(40);
|
||||
log.FatalFormat("{0} - Device successfully initialized", Name);
|
||||
}
|
||||
else
|
||||
{
|
||||
serialPort = null;
|
||||
log.FatalFormat("{0} - Device simulated", Name);
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>Run this device</summary>
|
||||
@@ -170,7 +161,6 @@ namespace TBF.Rig.Ambient.Greco
|
||||
|
||||
UpdateProcessData(temperature, pressure, humidity);
|
||||
msrmntTimeStamp = StateMachine.Time;
|
||||
msrmntState = MsrmntState.Valid;
|
||||
log.InfoFormat("Ambient: temperature = {0:F1} C, humidity = {1:F1} %, pressure = {2:F0} mbar", temperature, humidity, 1000 * pressure);
|
||||
}
|
||||
else
|
||||
@@ -193,18 +183,17 @@ namespace TBF.Rig.Ambient.Greco
|
||||
}
|
||||
|
||||
/// <summary>Run this device</summary>
|
||||
public void RunDeviceAfter()
|
||||
{
|
||||
}
|
||||
public void RunDeviceAfter() { }
|
||||
|
||||
/// <summary>Stop this device</summary>
|
||||
public void StopDevice()
|
||||
{
|
||||
if (serialPort != null) serialPort.Close();
|
||||
if (serialPort != null && serialPort.IsOpen) serialPort.Close();
|
||||
}
|
||||
|
||||
public void StopDevice2() { }
|
||||
|
||||
|
||||
void UpdateProcessData(double temperature, double pressure, double humidity)
|
||||
{
|
||||
TBF.Rig.Sequences.ProcessData.AmbTemp.Val = temperature;
|
||||
|
||||
Reference in New Issue