Files for Danfoss-VLT800-Pump added to the repository, builds OK
This commit is contained in:
@@ -0,0 +1,185 @@
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.Globalization;
|
||||
using System.IO.Ports;
|
||||
using System.Text;
|
||||
using log4net;
|
||||
using TBF.BenchControl.Generic;
|
||||
using TBF.Boxes;
|
||||
|
||||
namespace TBF.BenchControl.Danfoss.VLT2800
|
||||
{
|
||||
/// <summary>
|
||||
/// Ambient temperature / humidity / pressure meter 'Greco' connected via serial interface (RS232)
|
||||
/// Connection settings: 19200 Bd 8-bits No-parity 1-stop-bit Flow control: none or hardware.
|
||||
/// </summary>
|
||||
public class Pump : ComponentBase, IDevice, IOperation, GenericDevices.IAmbient
|
||||
{
|
||||
private static readonly ILog log = LogManager.GetLogger(typeof(Pump));
|
||||
public override string ToString() { return string.Format("Pump-Danfoss-VLT2800({0})", Cfg.ToString(1)); }
|
||||
|
||||
private readonly PumpCfg ambientCfg;
|
||||
|
||||
/// Private fields
|
||||
SerialPort serialPort;
|
||||
StringBuilder measurementBuilder;
|
||||
|
||||
/// <summary>The state of the measurement</summary>
|
||||
MsrmntState msrmntState;
|
||||
|
||||
/// <summary>Measured temperature when MsrmntState == MsrmntState.Valid</summary>
|
||||
float temperature;
|
||||
|
||||
/// <summary>Measured humidity when MsrmntState == MsrmntState.Valid</summary>
|
||||
float humidity;
|
||||
|
||||
/// <summary>Measured pressure when MsrmntState == MsrmntState.Valid</summary>
|
||||
float pressure;
|
||||
|
||||
/// <summary>Measurement time stamp when MsrmntState == MsrmntState.Valid</summary>
|
||||
int msrmntTimeStamp;
|
||||
|
||||
/// <summary>
|
||||
/// Ambient temperature / humidity / pressure meter 'Greco' connected via serial interface (RS232)
|
||||
/// Connection settings: 19200 Bd 8-bits No-parity 1-stop-bit Flow control: none or hardware.
|
||||
/// </summary>
|
||||
public Pump(PumpCfg cfg, IList<Generic.IComponent> components)
|
||||
: base(cfg)
|
||||
{
|
||||
ambientCfg = cfg;
|
||||
log.Debug(this.ToString());
|
||||
}
|
||||
|
||||
public void Initialize()
|
||||
{
|
||||
if (ambientCfg.DebugLevel == Entities.DebugMode.Simulate)
|
||||
{
|
||||
temperature = 20.0f;
|
||||
humidity = 40.0f;
|
||||
pressure = 1.0f;
|
||||
msrmntTimeStamp = StateMachine.Time;
|
||||
msrmntState = MsrmntState.Valid;
|
||||
return;
|
||||
}
|
||||
|
||||
string comPortName = "COM" + ambientCfg.ComPortNr.ToString();
|
||||
serialPort = new SerialPort(comPortName, ambientCfg.BaudRate, ambientCfg.Parity, ambientCfg.DataBits, ambientCfg.StopBits);
|
||||
serialPort.Handshake = ambientCfg.Handshake;
|
||||
serialPort.Open();
|
||||
measurementBuilder = new StringBuilder(40);
|
||||
msrmntState = MsrmntState.Busy;
|
||||
|
||||
log.FatalFormat("Successfully initialized device {0}", ToString());
|
||||
}
|
||||
|
||||
/// <summary>Run this device</summary>
|
||||
public void RunDeviceBefore()
|
||||
{
|
||||
if (ambientCfg.DebugLevel == Entities.DebugMode.Simulate)
|
||||
{
|
||||
msrmntTimeStamp = StateMachine.Time;
|
||||
return;
|
||||
}
|
||||
|
||||
measurementBuilder.Append(serialPort.ReadExisting());
|
||||
int len = measurementBuilder.Length;
|
||||
|
||||
///
|
||||
/// Device sends each 20 sec one line of ASCII text with data in the following format:
|
||||
/// (temp) 6 characters, two decimal digits, with leading spaces
|
||||
/// TAB 1 character
|
||||
/// (humi) 6 characters, two decimal digits, with leading spaces
|
||||
/// TAB 1 character
|
||||
/// (pressure) 6 characters, one decimal digits, with leading spaces is LT 1000
|
||||
/// CR + LF 2 characters
|
||||
/// Example:
|
||||
/// 23.42 38.08 1061.1
|
||||
/// 23.39 38.04 1060.8
|
||||
/// 23.39 38.08 1061.4
|
||||
///
|
||||
if (len >= 22)
|
||||
{
|
||||
string measurement = measurementBuilder.ToString();
|
||||
measurementBuilder.Clear();
|
||||
|
||||
float t = 0;
|
||||
float h = 0;
|
||||
float p = 0;
|
||||
if (float.TryParse(measurement.Substring(len - 22, 6), NumberStyles.AllowDecimalPoint | NumberStyles.AllowLeadingWhite,
|
||||
CultureInfo.InvariantCulture, out t) &&
|
||||
measurement[len - 16] == '\t' &&
|
||||
float.TryParse(measurement.Substring(len - 15, 6), NumberStyles.AllowDecimalPoint | NumberStyles.AllowLeadingWhite,
|
||||
CultureInfo.InvariantCulture, out h) &&
|
||||
measurement[len - 9] == '\t' &&
|
||||
float.TryParse(measurement.Substring(len - 8, 6), NumberStyles.AllowDecimalPoint | NumberStyles.AllowLeadingWhite,
|
||||
CultureInfo.InvariantCulture, out p) &&
|
||||
measurement[len - 2] == '\r' &&
|
||||
measurement[len - 1] == '\n')
|
||||
{
|
||||
temperature = t;
|
||||
humidity = h;
|
||||
pressure = p;
|
||||
msrmntTimeStamp = StateMachine.Time;
|
||||
msrmntState = MsrmntState.Valid;
|
||||
|
||||
log.InfoFormat("Msrmnt OK: time = {0}, temp={1}, humi={2}, pres={3}", msrmntTimeStamp, t, h, p);
|
||||
}
|
||||
else
|
||||
{
|
||||
log.Warn("Invalid string received: " + measurement);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>Run this device</summary>
|
||||
public void RunDeviceAfter()
|
||||
{
|
||||
}
|
||||
|
||||
/// <summary>Stop this device</summary>
|
||||
public void StopDevice()
|
||||
{
|
||||
if (serialPort != null) serialPort.Close();
|
||||
}
|
||||
|
||||
///
|
||||
/// Boxes for the operation result
|
||||
///
|
||||
FloatBox tempBox;
|
||||
FloatBox pressureBox;
|
||||
FloatBox humiBox;
|
||||
|
||||
public IOperation ReadAmbientOp(FloatBox temperature, FloatBox pressure, FloatBox humidity)
|
||||
{
|
||||
this.tempBox = temperature;
|
||||
this.pressureBox = pressure;
|
||||
this.humiBox = humidity;
|
||||
return this;
|
||||
}
|
||||
|
||||
/// <summary>Start this operation</summary>
|
||||
public void Start()
|
||||
{
|
||||
if (tempBox != null) tempBox.Val = temperature;
|
||||
if (pressureBox != null) pressureBox.Val = pressure;
|
||||
if (humiBox != null) humiBox.Val = humidity;
|
||||
}
|
||||
|
||||
/// <summary>Run this operation</summary>
|
||||
/// <returns>
|
||||
/// Event.FlowInDone or Event.FlowOutDone
|
||||
/// </returns>
|
||||
public Event Run()
|
||||
{
|
||||
if (tempBox != null) tempBox.Val = temperature;
|
||||
if (pressureBox != null) pressureBox.Val = pressure;
|
||||
if (humiBox != null) humiBox.Val = humidity;
|
||||
return Event.AmbientDone;
|
||||
}
|
||||
|
||||
/// <summary>Stop this operation</summary>
|
||||
public void Stop()
|
||||
{
|
||||
}
|
||||
}
|
||||
}
|
||||
Reference in New Issue
Block a user