@@ -0,0 +1,85 @@
= ked dam na DN100 zdruzeny test tak na konci testu pri prepisovani vysledkov padne:
pouzije sa index vodomera 2 (treti), pricom su ale iba 2 vodomery
= vyriesit znovunacitanie procedury po zmene
-----
Nove:
-----
- nezobrazit DebugLevel Inherit pre componenty ktore nemaju parenta
- ako osetrit nepodarenu detekciu (retry / continue) ?
- RefPulses pre camery
- Transitions sa nedaju vymazat
------
Stare:
------
- User interface pre interaktivne ovladanie kamier
- stop procedury a ulozenie vysledkov vodomerov - prerobit
- ako sa vysporiadat s detekciou: zobrazovanie progressu, vysledky, zobrazovanie vysledkov?
Podobne plati pre ine testy ako tlakova skuska, atp.
- process page je napisana iba pre jeden zdruzeny vodomer
- vyber vysledkov na obrazovke
- IDC100 kamera: Ako sa vysporiadat so sync. impulzami, casom startu a stopu?
- PID cisla pre kazdu regulacnu cestu zvlast
- Ked je WaterMeterStates dialog a dam Stop -> ide do Error
- Kvoli FixedStart testu a kameram by mal RegisterReader vracat 'double' (pripadne 'float') namiesto 'int' (???)
- 'zamykanie' hydraulickej schemy
- upozornit ked sa idu zahodit neulozene zmeny
- Zmen LocalSettings tak aby nebola potrebna metoda Assign()
- Ked sa otvori procedura zobrazit 3. tab
- ucesat logovanie
=============================
- zistit si timing kamery, zadavat v UI cas 1 otacky (alebo spocitat z prietoku ?)
- ked sa zada Pump1/4 power nespravne nie je hlaska dostatocne zavcasu
============ JB =============
- schovat alebo prelozit do nemciny 'Zobrazit Sim'
- Inicializacia
---------------
Prelozit do DE:
---------------
Data Entry (form)
Printer . . . Druecker
Results to disk
Purge - Begin
Purge - End
Meter Types Tested
Add (&Add >)
Arrangement of meters
Arrangement of tests
Available results
Combined meters
Detection completed
Emergency STOP
Flow Selection
Method_selection (Test method selection)
in Procedure dialog:
Transition - Start . . . Ubergang - Start
Transition - End . . . . Ubergang - Ende
Target Q [m3/h] . . . . Ziel Q [m3/h]
Relative Q from . . . . Relatives Q von
Relative Q to . . . . . Relatives Q bis
Rate of change . . . . . Aenderungsrate
Detection threshold . . Schwellwert
Component -> Komponente (3x)
Pulses pe liter . . . . Impulse pro Liter
Messung screen:
vymazat
Picrures:
Grab
Live
Focus
Camera
Process screen:
vela
---
Zobrazit Sim -> prec (ako?)
@@ -1,5 +1,7 @@
using System; using System;
using System.Collections.Generic; using System.Collections.Generic;
using System.Xml.Serialization;
using log4net;
using TBF.BenchControl; using TBF.BenchControl;
namespace TBF.BenchControl.BenchId namespace TBF.BenchControl.BenchId
@@ -9,7 +11,13 @@ namespace TBF.BenchControl.BenchId
/// </summary> /// </summary>
public class Component : ComponentBase, Generic.IComponent public class Component : ComponentBase, Generic.IComponent
{ {
readonly ComponentCfg benchIdCfg; private static readonly ILog log = LogManager.GetLogger(typeof(Component));
public override string ToString()
{
return string.Format("BenchId: Name={0}, TestBenchNr={1}", benchIdCfg.Name, TestBenchNr);
}
readonly ComponentCfg benchIdCfg;
public static void ResetStaticProperties() { } public static void ResetStaticProperties() { }
@@ -20,6 +28,8 @@ namespace TBF.BenchControl.BenchId
{ {
if (cfg == null) throw new ArgumentNullException("cfg"); if (cfg == null) throw new ArgumentNullException("cfg");
this.benchIdCfg = cfg; this.benchIdCfg = cfg;
}
log.Debug(this.ToString());
}
} }
} }
@@ -1,5 +1,6 @@
using System; using System;
using System.Collections.Generic; using System.Collections.Generic;
using log4net;
using TBF.BenchControl; using TBF.BenchControl;
using TBF.BenchControl.GenericDevices; using TBF.BenchControl.GenericDevices;
@@ -7,7 +8,14 @@ namespace TBF.BenchControl.DataEntry.Munich
{ {
public class EntryForm : Generic.IComponent, IOperation, IDataEntry, IHasCycleBeginForm, IHasCycleEndForm, IHasProtocolTitle public class EntryForm : Generic.IComponent, IOperation, IDataEntry, IHasCycleBeginForm, IHasCycleEndForm, IHasProtocolTitle
{ {
readonly EntryFormCfg entryFormCfg; private static readonly ILog log = LogManager.GetLogger(typeof(EntryForm));
public override string ToString()
{
return string.Format("Name={0}", Name);
}
readonly EntryFormCfg entryFormCfg;
public Generic.IComponentCfg Cfg { get { return entryFormCfg; } } public Generic.IComponentCfg Cfg { get { return entryFormCfg; } }
public static void ResetStaticProperties() { } public static void ResetStaticProperties() { }
@@ -20,10 +28,10 @@ namespace TBF.BenchControl.DataEntry.Munich
public string MainBeginStateText { get { return mainBeginStateText; } } public string MainBeginStateText { get { return mainBeginStateText; } }
string mainBeginStateText; string mainBeginStateText;
public string AuxBegintateText { get { return auxBeginStateText; } } public string AuxBeginStateText { get { return auxBeginStateText; } }
string auxBeginStateText; string auxBeginStateText;
public string ProtocolTitle { get { return protocolTitle; } } public string ProtocolTitle { get { return protocolTitle; } }
string protocolTitle; string protocolTitle;
@@ -60,7 +68,9 @@ namespace TBF.BenchControl.DataEntry.Munich
if (cfg == null) throw new ArgumentNullException("cfg"); if (cfg == null) throw new ArgumentNullException("cfg");
this.entryFormCfg = cfg; this.entryFormCfg = cfg;
currentOp = CurrentOp.None; currentOp = CurrentOp.None;
}
log.Debug(this.ToString());
}
/// <returns>Reference to the operation</returns> /// <returns>Reference to the operation</returns>
public IOperation ShowCycleBeginFormOp(IList<IWaterMeter> waterMeters) public IOperation ShowCycleBeginFormOp(IList<IWaterMeter> waterMeters)
@@ -1,5 +1,6 @@
using System; using System;
using System.Collections.Generic; using System.Collections.Generic;
using log4net;
using TBF.BenchControl; using TBF.BenchControl;
using TBF.BenchControl.GenericDevices; using TBF.BenchControl.GenericDevices;
@@ -7,7 +8,14 @@ namespace TBF.BenchControl.DataEntry.Munich3
{ {
public class EntryForm : Generic.IComponent, IOperation, IDataEntry, IHasCycleBeginForm, IHasCycleEndForm, IHasProtocolTitle public class EntryForm : Generic.IComponent, IOperation, IDataEntry, IHasCycleBeginForm, IHasCycleEndForm, IHasProtocolTitle
{ {
readonly EntryFormCfg entryFormCfg; private static readonly ILog log = LogManager.GetLogger(typeof(EntryForm));
public override string ToString()
{
return string.Format("Name={0}", Name);
}
readonly EntryFormCfg entryFormCfg;
public Generic.IComponentCfg Cfg { get { return entryFormCfg; } } public Generic.IComponentCfg Cfg { get { return entryFormCfg; } }
public static void ResetStaticProperties() { } public static void ResetStaticProperties() { }
@@ -54,7 +62,9 @@ namespace TBF.BenchControl.DataEntry.Munich3
if (cfg == null) throw new ArgumentNullException("cfg"); if (cfg == null) throw new ArgumentNullException("cfg");
this.entryFormCfg = cfg; this.entryFormCfg = cfg;
currentOp = CurrentOp.None; currentOp = CurrentOp.None;
}
log.Debug(this.ToString());
}
/// <returns>Reference to the operation</returns> /// <returns>Reference to the operation</returns>
public IOperation ShowCycleBeginFormOp(IList<IWaterMeter> waterMeters) public IOperation ShowCycleBeginFormOp(IList<IWaterMeter> waterMeters)
@@ -1,5 +1,6 @@
using System; using System;
using System.Collections.Generic; using System.Collections.Generic;
using log4net;
using TBF.BenchControl; using TBF.BenchControl;
using TBF.BenchControl.GenericDevices; using TBF.BenchControl.GenericDevices;
@@ -7,7 +8,14 @@ namespace TBF.BenchControl.DataEntry.WMStates
{ {
public class EntryForm : Generic.IComponent, IOperation, IDataEntry, IHasWMStatesForm public class EntryForm : Generic.IComponent, IOperation, IDataEntry, IHasWMStatesForm
{ {
readonly EntryFormCfg entryFormCfg; private static readonly ILog log = LogManager.GetLogger(typeof(EntryForm));
public override string ToString()
{
return string.Format("Name={0}", Name);
}
readonly EntryFormCfg entryFormCfg;
public Generic.IComponentCfg Cfg { get { return entryFormCfg; } } public Generic.IComponentCfg Cfg { get { return entryFormCfg; } }
public static void ResetStaticProperties() { } public static void ResetStaticProperties() { }
@@ -63,7 +71,9 @@ namespace TBF.BenchControl.DataEntry.WMStates
serialNr = new string[Program.WMsCount]; serialNr = new string[Program.WMsCount];
wmState = new float[Program.WMsCount]; wmState = new float[Program.WMsCount];
currentOp = CurrentOp.None; currentOp = CurrentOp.None;
}
log.Debug(this.ToString());
}
/// <returns>Reference to the operation</returns> /// <returns>Reference to the operation</returns>
public IOperation ShowCycleBeginFormOp(IList<IWaterMeter> waterMeters) public IOperation ShowCycleBeginFormOp(IList<IWaterMeter> waterMeters)
@@ -16,7 +16,10 @@ namespace TBF.BenchControl.Elde
/// Error: /// Error:
/// </summary> /// </summary>
private static readonly ILog log = LogManager.GetLogger(typeof(ControlBoardDev)); private static readonly ILog log = LogManager.GetLogger(typeof(ControlBoardDev));
public override string ToString() { return string.Format("ControlBoardDev on com{0}", controlBoardCfg.ComPortNr); } public override string ToString()
{
return string.Format("ControlBoardDev: Name={0}, ComPort={1}", controlBoardCfg.Name, controlBoardCfg.ComPortNr);
}
public static void ResetStaticProperties() { } public static void ResetStaticProperties() { }
@@ -25,7 +25,7 @@ namespace TBF.BenchControl.Elde.Diverter
readonly ControlBoardDev controlBoard; readonly ControlBoardDev controlBoard;
public readonly ulong Mask; /// derived from bitPosition in the constructor readonly ulong mask; /// derived from bitPosition in the constructor
public Diverter(DiverterCfg cfg, IList<Generic.IComponent> components) public Diverter(DiverterCfg cfg, IList<Generic.IComponent> components)
@@ -37,14 +37,14 @@ namespace TBF.BenchControl.Elde.Diverter
if (controlBoard == null) throw new Exception("Cannot find " + Name + " parent"); if (controlBoard == null) throw new Exception("Cannot find " + Name + " parent");
if (cfg.BitPosition < 0 || cfg.BitPosition >= 64) throw new ArgumentOutOfRangeException("position"); if (cfg.BitPosition < 0 || cfg.BitPosition >= 64) throw new ArgumentOutOfRangeException("position");
this.Mask = (((ulong)1) << cfg.BitPosition); this.mask = (((ulong)1) << cfg.BitPosition);
log.Debug(this.ToString()); log.Debug(this.ToString());
} }
public bool State public bool State
{ {
get { return (controlBoard.Route & Mask) != 0; } get { return (controlBoard.Route & mask) != 0; }
} }
} }
} }
@@ -14,7 +14,7 @@ namespace TBF.BenchControl.Elde.FlowMeter
private static readonly ILog log = LogManager.GetLogger(typeof(FlowMeter)); private static readonly ILog log = LogManager.GetLogger(typeof(FlowMeter));
public override string ToString() public override string ToString()
{ {
return string.Format("FlowMeter({0},{1})", Name, Idx1); return string.Format("FlowMeter: Name={0}, Idx1={1}", Name, Idx1);
} }
public static void ResetStaticProperties() { } public static void ResetStaticProperties() { }
@@ -28,9 +28,8 @@ namespace TBF.BenchControl.Elde.FlowMeter
public readonly ControlBoardDev ControlBoard; public readonly ControlBoardDev ControlBoard;
readonly float nominalFlow;
public float NominalFlow { get { return nominalFlow; } } public float NominalFlow { get { return nominalFlow; } }
readonly float nominalFlow;
public float LtrPerPulse { get { return nominalFlow / 7200.0f; } } public float LtrPerPulse { get { return nominalFlow / 7200.0f; } }
@@ -14,8 +14,8 @@ namespace TBF.BenchControl.Elde.FlowMeterTwins
private static readonly ILog log = LogManager.GetLogger(typeof(FlowMeter)); private static readonly ILog log = LogManager.GetLogger(typeof(FlowMeter));
public override string ToString() public override string ToString()
{ {
return string.Format("FlowMeter({0})", Name); return string.Format("FlowMeter: Name={0}", Name);
} }
public static void ResetStaticProperties() { } public static void ResetStaticProperties() { }
@@ -23,15 +23,17 @@ namespace TBF.BenchControl.Elde.FlowMeterTwins
public Generic.IComponentCfg Cfg { get { return flowMeterCfg; } } public Generic.IComponentCfg Cfg { get { return flowMeterCfg; } }
public string Name { get { return flowMeterCfg.Name; } } public string Name { get { return flowMeterCfg.Name; } }
public int Idx1 { get { return 0; } }
public IList<Entities.MeasurementCorrection> Corrections { get { return flowMeterCfg.Corrections; } } public IList<Entities.MeasurementCorrection> Corrections { get { return flowMeterCfg.Corrections; } }
public readonly ControlBoardDev ControlBoard; public int Idx1 { get { return 0; } }
public readonly ControlBoardDev ControlBoard;
public readonly TBF.BenchControl.Elde.FlowMeter.FlowMeter FlowMeter1; public readonly TBF.BenchControl.Elde.FlowMeter.FlowMeter FlowMeter1;
public readonly TBF.BenchControl.Elde.FlowMeter.FlowMeter FlowMeter2; public readonly TBF.BenchControl.Elde.FlowMeter.FlowMeter FlowMeter2;
readonly float nominalFlow;
public float NominalFlow { get { return nominalFlow; } } public float NominalFlow { get { return nominalFlow; } }
readonly float nominalFlow;
/// The nominal flowed of a pair of flow meters is reached at 4000Hz /// The nominal flowed of a pair of flow meters is reached at 4000Hz
public float LtrPerPulse { get { return nominalFlow / 14400.0f; } } public float LtrPerPulse { get { return nominalFlow / 14400.0f; } }
@@ -15,7 +15,7 @@ namespace TBF.BenchControl.Elde.PressureMeter
private static readonly ILog log = LogManager.GetLogger(typeof(PressureMeter)); private static readonly ILog log = LogManager.GetLogger(typeof(PressureMeter));
public override string ToString() public override string ToString()
{ {
return string.Format("PressureMeter({0},{1})", Name, Idx0); return string.Format("PressureMeter: Name={0}, Idx0={1}", Name, Idx0);
} }
public static void ResetStaticProperties() { } public static void ResetStaticProperties() { }
+1 -1
View File
@@ -79,7 +79,7 @@
this.MinimizeBox = false; this.MinimizeBox = false;
this.Name = "ComponentAddDlg"; this.Name = "ComponentAddDlg";
this.SizeGripStyle = System.Windows.Forms.SizeGripStyle.Hide; this.SizeGripStyle = System.Windows.Forms.SizeGripStyle.Hide;
this.Load += new System.EventHandler(this.AddComponentDlg_Load); this.Load += new System.EventHandler(this.SelectComponentClassDlg_Load);
this.ResumeLayout(false); this.ResumeLayout(false);
this.PerformLayout(); this.PerformLayout();
@@ -23,7 +23,7 @@ namespace TBF
} }
/// Load components from BenchControl.SupportedComponents /// Load components from BenchControl.SupportedComponents
private void AddComponentDlg_Load(object sender, EventArgs e) private void SelectComponentClassDlg_Load(object sender, EventArgs e)
{ {
if (selectedIndex >= 0 && selectedIndex < BenchControl.TbfComponents.Factories.Count) if (selectedIndex >= 0 && selectedIndex < BenchControl.TbfComponents.Factories.Count)
{ {