(1) Genesis component upgraded, (2) FixedStartMassCollectionSeq : Opening start/stop valve in 2nd repetition fixed, ver. 2.12.453
This commit is contained in:
+12
-3
@@ -164,10 +164,18 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
||||
//------------------------------------------------
|
||||
Bridge.OnActivity(this, Strings.Setting_the_flow);
|
||||
//------------------------------------------------
|
||||
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
||||
if (inPath.Pump is GenericDevices.IPumpFM)
|
||||
{
|
||||
(inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
||||
}
|
||||
///
|
||||
IList<GenericDevices.IValve> valvesOpen = new List<GenericDevices.IValve>();
|
||||
valvesOpen.Add(inPath.Pump);
|
||||
valvesOpen.Add(outPath.StartValve);
|
||||
///
|
||||
State.Create("FixedStartMassCollection : Starting the pump")
|
||||
.AddOperation(checkUiOp)
|
||||
.AddOperation(cBrd.SetValvesOp(inPath.Pump, null))
|
||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(valvesOpen, null))
|
||||
.AddOperation(heatMetersPromptOp)
|
||||
.EnterState();
|
||||
do
|
||||
@@ -178,7 +186,8 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
||||
|
||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||
}
|
||||
while (!e.Contains(Event.ValvesSet));
|
||||
while (e.Contains(Event.ValvesBusy));
|
||||
|
||||
|
||||
//--------------------------------
|
||||
State.Create("FixedStartMassCollection : Setting the flow")
|
||||
|
||||
@@ -29,5 +29,5 @@ using System.Runtime.InteropServices;
|
||||
// Build Number
|
||||
// Revision
|
||||
//
|
||||
[assembly: AssemblyVersion("2.12.452.1")]
|
||||
[assembly: AssemblyFileVersion("2.12.452.1")]
|
||||
[assembly: AssemblyVersion("2.12.453.1")]
|
||||
[assembly: AssemblyFileVersion("2.12.453.1")]
|
||||
|
||||
Binary file not shown.
Reference in New Issue
Block a user