Start- and End-volume for the fixed start method can be saved/printed in results.
This commit is contained in:
@@ -224,6 +224,15 @@ namespace Results
|
||||
AllItems.Add(new WMeterRsltItemSpec(ItemID.Remark, Strings.Remark, Quantity.String, (w, t, u, f, p) => w.Batch.Remark));
|
||||
AllItems.Add(new WMeterRsltItemSpec(ItemID.Meter_type, Strings.Meter_type, Quantity.String, (w, t, u, f, p) => w.WaterMeterData.Compound ? Strings.Compound : (w.WaterMeterData.HeatMeter ? Strings.Heat_meter : Strings.Single)));
|
||||
|
||||
AllItems.Add(new WMeterRsltItemSpec(ItemID.Volume_main, Strings.Volume_main + "()", Quantity.Volume, (w, t, u, f, p) => (w.GetMeterTestRslt(t, CompoundMeterId.CompoundMain) == null) ? "" : Config.Units.ConvertTo(u, w.GetMeterTestRslt(t).VolumeMeter).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
||||
AllItems.Add(new WMeterRsltItemSpec(ItemID.Volume_aux, Strings.Volume_aux + "()", Quantity.Volume, (w, t, u, f, p) => (w.GetMeterTestRslt(t, CompoundMeterId.CompoundAux) == null) ? "" : Config.Units.ConvertTo(u, w.GetMeterTestRslt(t).VolumeMeter).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
||||
AllItems.Add(new WMeterRsltItemSpec(ItemID.Start_volume, Strings.Start_volume + "()", Quantity.Volume, (w, t, u, f, p) => (w.GetMeterTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetMeterTestRslt(t).VolumeStart).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
||||
AllItems.Add(new WMeterRsltItemSpec(ItemID.Start_volume_main, Strings.Start_volume_main + "()", Quantity.Volume, (w, t, u, f, p) => (w.GetMeterTestRslt(t, CompoundMeterId.CompoundMain) == null) ? "" : Config.Units.ConvertTo(u, w.GetMeterTestRslt(t).VolumeStart).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
||||
AllItems.Add(new WMeterRsltItemSpec(ItemID.Start_volume_aux, Strings.Start_volume_aux + "()", Quantity.Volume, (w, t, u, f, p) => (w.GetMeterTestRslt(t, CompoundMeterId.CompoundAux) == null) ? "" : Config.Units.ConvertTo(u, w.GetMeterTestRslt(t).VolumeStart).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
||||
AllItems.Add(new WMeterRsltItemSpec(ItemID.End_volume, Strings.End_volume + "()", Quantity.Volume, (w, t, u, f, p) => (w.GetMeterTestRslt(t) == null) ? "" : Config.Units.ConvertTo(u, w.GetMeterTestRslt(t).VolumeEnd).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
||||
AllItems.Add(new WMeterRsltItemSpec(ItemID.End_volume_main, Strings.End_volume_main + "()", Quantity.Volume, (w, t, u, f, p) => (w.GetMeterTestRslt(t, CompoundMeterId.CompoundMain) == null) ? "" : Config.Units.ConvertTo(u, w.GetMeterTestRslt(t).VolumeEnd).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
||||
AllItems.Add(new WMeterRsltItemSpec(ItemID.End_volume_aux, Strings.End_volume_aux + "()", Quantity.Volume, (w, t, u, f, p) => (w.GetMeterTestRslt(t, CompoundMeterId.CompoundAux) == null) ? "" : Config.Units.ConvertTo(u, w.GetMeterTestRslt(t).VolumeEnd).ToString(string.IsNullOrEmpty(p) ? "F3" : p)));
|
||||
|
||||
#if HEAT_METERS_SUPPORT
|
||||
AllItems.Add(new WMeterRsltItemSpec(ItemID.Energy, Strings.Energy + "()", Quantity.Energy, (w, t, u, f, p) => (w.GetMeterTestRslt(t, Config.Entities.CompoundMeterId.HeatMeterEnergy) == null) ? "" : Config.Units.ConvertTo(u, w.GetMeterTestRslt(t, Config.Entities.CompoundMeterId.HeatMeterEnergy).VolumeMeter).ToString(string.IsNullOrEmpty(p) ? "F1" : p)));
|
||||
AllItems.Add(new WMeterRsltItemSpec(ItemID.Reference_energy, Strings.Energy_ref + "()", Quantity.Energy, (w, t, u, f, p) => (w.GetMeterTestRslt(t, Config.Entities.CompoundMeterId.HeatMeterEnergy) == null) ? "" : Config.Units.ConvertTo(u, w.GetMeterTestRslt(t, Config.Entities.CompoundMeterId.HeatMeterEnergy).VolumeRef).ToString(string.IsNullOrEmpty(p) ? "F1" : p)));
|
||||
|
||||
Reference in New Issue
Block a user