All PumpsWithFM are controlled when opening pumps at the test start
This commit is contained in:
+7
-7
@@ -102,9 +102,9 @@ namespace TBF.BenchControl.TestMethods.FlyingStartCollectionMethod
|
||||
//------------------------------------------------
|
||||
Bridge.OnActivity(this, Strings.Setting_the_flow);
|
||||
//------------------------------------------------
|
||||
foreach (var pump in PumpsWithFM) pump.TurnOnDfltPower();
|
||||
State.Create("FlyingStartCollectionMethod : Starting the pump")
|
||||
.AddOperation(checkUiOp)
|
||||
.AddOperation((inPath.Pump is GenericDevices.IPumpFM) ? (inPath.Pump as GenericDevices.IPumpFM).TurnOnDfltPowerOp() : null)
|
||||
.AddOperation(cBrd.SetValvesOp(inPath.Pump, null))
|
||||
.EnterState();
|
||||
do
|
||||
@@ -279,15 +279,15 @@ namespace TBF.BenchControl.TestMethods.FlyingStartCollectionMethod
|
||||
tstRslt.MassStart = Formulas.CorrectedValue(tstRslt.MassStartRaw, outPath.Balance.Corrections);
|
||||
tstRslt.MassEnd = Formulas.CorrectedValue(tstRslt.MassEndRaw, outPath.Balance.Corrections);
|
||||
tstRslt.MassDiff = tstRslt.MassEnd - tstRslt.MassStart;
|
||||
tstRslt.DensityIn = Formulas.WaterDensityFromTemp(tstRslt.TempInAvrg); /// [kg/m3]
|
||||
tstRslt.DensityIn = Formulas.WaterDensityFromTemp(tstRslt.TempInAvrg); /// [kg/m3]
|
||||
tstRslt.DensityOut = Formulas.WaterDensityFromTemp(tstRslt.TempOutAvrg); /// [kg/m3]
|
||||
tstRslt.DensityDiv = Formulas.WaterDensityFromTemp(tstRslt.TempDivAvrg); /// [kg/m3]
|
||||
tstRslt.Time = cBrd.TTime; /// [s] measurement time
|
||||
tstRslt.FlowMass = 3600.0f * tstRslt.MassDiff / tstRslt.Time; /// [kg/h]
|
||||
tstRslt.Time = cBrd.TTime; /// [s] measurement time
|
||||
tstRslt.FlowMass = 3600.0f * tstRslt.MassDiff / tstRslt.Time; /// [kg/h]
|
||||
tstRslt.FlowVolume = 3600.0f * ltrPerRefPulse * cBrd.EtPulses(0) / tstRslt.Time; /// [l/h]
|
||||
tstRslt.VolumeCTV = 1.00103f * 1000.0f * tstRslt.MassDiff / tstRslt.DensityOut; /// [l] 1000.0f is because density is in [kg/m3]
|
||||
tstRslt.VolumeMaster = ltrPerRefPulse * cBrd.EtPulses(0); /// [l] volume from the master flow meter
|
||||
tstRslt.PulsesMaster = cBrd.EtPulses(0); /// Pulses of the master flow meter (test total)
|
||||
tstRslt.VolumeCTV = 1.00103f * 1000.0f * tstRslt.MassDiff / tstRslt.DensityOut; /// [l] 1000.0f is because density is in [kg/m3]
|
||||
tstRslt.VolumeMaster = ltrPerRefPulse * cBrd.EtPulses(0); /// [l] volume from the master flow meter
|
||||
tstRslt.PulsesMaster = cBrd.EtPulses(0); /// Pulses of the master flow meter (test total)
|
||||
tstRslt.ConstMaster = ltrPerRefPulse * tstRslt.VolumeCTV / tstRslt.VolumeMaster;
|
||||
/// Corrected master pulses per liter
|
||||
if (tstRslt.VolumeCTV <= float.Epsilon)
|
||||
|
||||
Reference in New Issue