Bug fixes in FixedStartSeq, ver. 2.18.854
This commit is contained in:
@@ -419,7 +419,7 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
||||
|
||||
TestStartTime = DateTime.Now;
|
||||
LogProcessDataTestInfo(processDataLogger, test.Procedure.Name, test.Name);
|
||||
int startPulses = cBrd.EtPulses(0);
|
||||
int startPulses = 0;
|
||||
|
||||
///
|
||||
/// Enter watermeter begin states here
|
||||
@@ -548,7 +548,7 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
||||
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Diverter | Elde.TestMethods.Synchro,
|
||||
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Synchro,
|
||||
test.Qfrom, test.Qto, 2 * totalPulses, (float)test.TolerRed))
|
||||
.EnterState();
|
||||
do
|
||||
|
||||
Reference in New Issue
Block a user