Danfoss-VLT2800-Pump functions OK, TODO: control the valve of the pump
This commit is contained in:
@@ -35,10 +35,6 @@ namespace TBF.BenchControl.Danfoss.VLT2800
|
||||
stopBitsComboBox.Items.Add(StopBits.One.ToString());
|
||||
stopBitsComboBox.Items.Add(StopBits.OnePointFive.ToString());
|
||||
stopBitsComboBox.Items.Add(StopBits.Two.ToString());
|
||||
|
||||
handshakeComboBox.Items.Add(Handshake.None.ToString());
|
||||
handshakeComboBox.Items.Add(Handshake.RequestToSend.ToString());
|
||||
handshakeComboBox.Items.Add(Handshake.XOnXOff.ToString());
|
||||
}
|
||||
|
||||
int GetParityIx(Parity par)
|
||||
@@ -103,23 +99,25 @@ namespace TBF.BenchControl.Danfoss.VLT2800
|
||||
|
||||
classNameLabel.Text = config.Factory.ClassName;
|
||||
nameTextBox.Text = config.Name;
|
||||
delayTextBox.Text = config.Delay.ToString();
|
||||
modbusAddressTextBox.Text = config.ModbusAddress.ToString();
|
||||
comPortNrTextBox.Text = config.ComPortNr.ToString();
|
||||
baudRateTextBox.Text = config.BaudRate.ToString();
|
||||
parityComboBox.Text = config.Parity.ToString();
|
||||
dataBitsTextBox.Text = config.DataBits.ToString();
|
||||
stopBitsComboBox.Text = config.StopBits.ToString();
|
||||
handshakeComboBox.Text = config.Handshake.ToString();
|
||||
}
|
||||
|
||||
public void Unlock()
|
||||
{
|
||||
nameTextBox.Enabled = true;
|
||||
delayTextBox.Enabled = true;
|
||||
modbusAddressTextBox.Enabled = true;
|
||||
comPortNrTextBox.Enabled = true;
|
||||
baudRateTextBox.Enabled = true;
|
||||
parityComboBox.Enabled = true;
|
||||
dataBitsTextBox.Enabled = true;
|
||||
stopBitsComboBox.Enabled = true;
|
||||
handshakeComboBox.Enabled = true;
|
||||
}
|
||||
|
||||
public CfgUpdateFlags UpdateCfg()
|
||||
@@ -129,12 +127,13 @@ namespace TBF.BenchControl.Danfoss.VLT2800
|
||||
if (config == null) return CfgUpdateFlags.Error; /// Control was not loaded, settings were not changed
|
||||
|
||||
config.Name = nameTextBox.Text;
|
||||
config.Delay = int.Parse(delayTextBox.Text);
|
||||
config.ModbusAddress = int.Parse(modbusAddressTextBox.Text);
|
||||
config.ComPortNr = int.Parse(comPortNrTextBox.Text);
|
||||
config.BaudRate = int.Parse(baudRateTextBox.Text);
|
||||
config.Parity = GetParity(parityComboBox.SelectedItem.ToString());
|
||||
config.DataBits = int.Parse(dataBitsTextBox.Text);
|
||||
config.StopBits = GetStopBits(stopBitsComboBox.SelectedItem.ToString());
|
||||
config.Handshake = GetHandshake(handshakeComboBox.SelectedItem.ToString());
|
||||
|
||||
return flags;
|
||||
}
|
||||
@@ -144,6 +143,18 @@ namespace TBF.BenchControl.Danfoss.VLT2800
|
||||
CfgUpdateFlags flags = CfgUpdateFlags.None;
|
||||
|
||||
int dummy;
|
||||
if (!int.TryParse(delayTextBox.Text, out dummy) || dummy < 0 || dummy > 300)
|
||||
{
|
||||
flags |= CfgUpdateFlags.Error;
|
||||
message += Environment.NewLine + "'Delay' is not valid";
|
||||
}
|
||||
|
||||
if (!int.TryParse(modbusAddressTextBox.Text, out dummy) || dummy < 1 || dummy > 247)
|
||||
{
|
||||
flags |= CfgUpdateFlags.Error;
|
||||
message += Environment.NewLine + "'Modbus Address' should be in range 1..247";
|
||||
}
|
||||
|
||||
if (!int.TryParse(comPortNrTextBox.Text, out dummy) || dummy < 1 || dummy > 999)
|
||||
{
|
||||
flags |= CfgUpdateFlags.Error;
|
||||
|
||||