Process data display : many changes, TODO: Meter data and the end of test.
This commit is contained in:
@@ -34,13 +34,13 @@ namespace TBF.BenchControl.TestMethods.FlyingStart
|
||||
Event retVal = Event.Done;
|
||||
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||
|
||||
ltrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
||||
LtrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
||||
|
||||
/// Notes:
|
||||
/// float timeHr = volumeLtr / (1000.0f * targetFlow);
|
||||
/// float timeSec = 3600.0f * timeHr;
|
||||
/// int refPulses = (int)(timeSec * (2000.0f * targetFlow / pOut.FlowMeter.NominalFlow));
|
||||
int totalPulses = (int)(test.Volume / ltrPerRefPulse + 0.5f);
|
||||
int totalPulses = (int)(test.Volume / LtrPerRefPulse + 0.5f);
|
||||
|
||||
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this);
|
||||
|
||||
@@ -79,6 +79,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStart
|
||||
do
|
||||
{
|
||||
e = StateMachine.WaitRunDevsRunOps();
|
||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||
|
||||
if (e.Contains(Event.UiCmdStop)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||
@@ -93,6 +94,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStart
|
||||
do
|
||||
{
|
||||
e = StateMachine.WaitRunDevsRunOps();
|
||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||
|
||||
if (e.Contains(Event.OpArgumentError)) { retVal = Event.OpArgumentError; goto stopTest; }
|
||||
@@ -173,8 +175,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStart
|
||||
}
|
||||
|
||||
UpdateAllStatistics();
|
||||
CurrentMassRaw = Mass.Val;
|
||||
RefFreq.Val = cBrd.ReferenceFreq;
|
||||
RefFreq.Val = cBrd.ReferenceFreq;
|
||||
RefFlow.Val = cBrd.ReferenceFlow;
|
||||
|
||||
string logstr = string.Format("E={0} f={1} q={2}", cBrd.EtPulses(0), cBrd.ReferenceFreq,
|
||||
@@ -185,6 +186,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStart
|
||||
}
|
||||
log.Debug(logstr);
|
||||
|
||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
||||
}
|
||||
/// Measurement loop - end
|
||||
@@ -251,8 +253,8 @@ namespace TBF.BenchControl.TestMethods.FlyingStart
|
||||
tstRslt.MassEndRaw = 0;
|
||||
tstRslt.MassEnd = 0;
|
||||
tstRslt.FlowMass = 0; /// [kg/h]
|
||||
tstRslt.FlowVolume = 3.6 * ltrPerRefPulse * tstRslt.PulsesMaster / tstRslt.TestTime; /// [m3/h]
|
||||
tstRslt.VolumeMaster = ltrPerRefPulse * tstRslt.PulsesMaster; /// [l] volume from the master flow meter
|
||||
tstRslt.FlowVolume = 3.6 * LtrPerRefPulse * tstRslt.PulsesMaster / tstRslt.TestTime; /// [m3/h]
|
||||
tstRslt.VolumeMaster = LtrPerRefPulse * tstRslt.PulsesMaster; /// [l] volume from the master flow meter
|
||||
tstRslt.ConstMaster = outPath.FlowMeter.LtrPerPulseCorrected(tstRslt.FlowVolume); /// Corrected master pulses per liter
|
||||
tstRslt.VolumeCTV = tstRslt.ConstMaster * tstRslt.PulsesMaster; /// [l] 1000.0f is because density is in [kg/m3]
|
||||
tstRslt.ErrorMaster = 0.0; /// Cannot be determined without a mass measurement
|
||||
|
||||
Reference in New Issue