TestTimeCorrection and MassOfEvapWater are stored in SummaryResults columns BK resp. BB
This commit is contained in:
@@ -408,7 +408,7 @@ namespace TBF.BenchControl.TestMethods.PulsesTestManual
|
||||
tstRslt.MassEnd = 0;
|
||||
tstRslt.FlowMass = 0; /// [kg/h]
|
||||
tstRslt.FlowVolume = 3.6 * LtrPerRefPulse * cBrd.EtPulses(0) / tstRslt.TestTime; /// [m3/h]
|
||||
tstRslt.Buoyancy = Config.Formulas.Buoyancy();
|
||||
tstRslt.MassOfEvapWater = 0;
|
||||
tstRslt.VolumeMaster = LtrPerRefPulse * tstRslt.PulsesMaster; /// [l] volume from the master flow meter
|
||||
tstRslt.ConstMasterRaw = outPath.FlowMeter.LtrPerPulse; /// Uncorrected master flowmeter coefficient
|
||||
tstRslt.ConstMasterCorr = outPath.FlowMeter.LtrPerPulseCorrected(tstRslt.FlowVolume, rangeIx); /// Corrected master pulses per liter
|
||||
|
||||
Reference in New Issue