TestTimeCorrection and MassOfEvapWater are stored in SummaryResults columns BK resp. BB

This commit is contained in:
Milan Hanajik
2021-01-29 10:46:45 +01:00
parent 0fa8057324
commit 241bb3aff1
27 changed files with 59 additions and 57 deletions
@@ -699,8 +699,8 @@ namespace TBF.BenchControl.TestMethods.DiverterTest
tstRslt.MassEnd = Config.Formulas.CorrectedValue(tstRslt.MassEndRaw, scale.Corrections);
tstRslt.FlowMass = 3600.0 * (tstRslt.MassEnd - tstRslt.MassStart + massOfEvaporatedWater) / tstRslt.TestTime; /// [kg/h]
tstRslt.FlowVolume = 3.6 * LtrPerRefPulse * tstRslt.PulsesMaster / tstRslt.TestTime; /// [m3/h]
tstRslt.Buoyancy = Config.Formulas.Buoyancy();
tstRslt.VolumeCTV = 1000 * tstRslt.Buoyancy * (tstRslt.MassEnd - tstRslt.MassStart + massOfEvaporatedWater) / tstRslt.DensityLine; /// [l] commercially true volume
tstRslt.MassOfEvapWater = massOfEvaporatedWater;
tstRslt.VolumeCTV = 1000 * tstRslt.Batch.Buoyancy * (tstRslt.MassEnd - tstRslt.MassStart + massOfEvaporatedWater) / tstRslt.DensityLine; /// [l] commercially true volume
if ((outPath.Diverter != null) && (tstRslt.TestTime > float.Epsilon))
{
tstRslt.TestTimeCorrection = testParams.DivRepetitions * outPath.Diverter.TestTimeCorrection(tstRslt.FlowVolume);