iPerl and iPerlHead separated, iPerl removed (WaterMeter should be used instead).
This commit is contained in:
+224
-185
@@ -16,7 +16,7 @@ using log4net;
|
||||
using Config.Entities;
|
||||
using TBF.Resources;
|
||||
using TBF.BenchControl.Sequences;
|
||||
using TBF.BenchControl.WaterMeters.iPerl;
|
||||
using TBF.BenchControl.TestMethods.iPerlCommunication.iPerlHead;
|
||||
|
||||
namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
{
|
||||
@@ -74,17 +74,17 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
/// <param name="boardNr">0..3</param>
|
||||
/// <param name="comPort">Com port number</param>
|
||||
/// <returns>Value returned by openPort(...)</returns>
|
||||
public static unsafe int OpenPort(WaterMeters.iPerl.WaterMeter wm)
|
||||
public static unsafe int OpenPort(IperlHead iperlHead)
|
||||
{
|
||||
if (wm.DebugLevel != DebugMode.Normal) return 0; /// No function in debug mode
|
||||
if (iperlHead.DebugLevel != DebugMode.Normal) return 0; /// No function in debug mode
|
||||
|
||||
if (wm.RfidComPortNr > 0)
|
||||
if (iperlHead.RfidComPortNr > 0)
|
||||
{
|
||||
return openPort1(wm.RfidComPortNr);
|
||||
return openPort1(iperlHead.RfidComPortNr);
|
||||
}
|
||||
else
|
||||
{
|
||||
switch (wm.MuxBoardNr)
|
||||
switch (iperlHead.MuxBoardNr)
|
||||
{
|
||||
default:
|
||||
case 1: return openPort1(cfg.RfidPortNrBoard1);
|
||||
@@ -101,17 +101,17 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
/// <param name="boardNr">0..3</param>
|
||||
/// <param name="comPort">Com port number</param>
|
||||
/// <returns>Value returned by openPort(...)</returns>
|
||||
public static unsafe int ClosePort(WaterMeters.iPerl.WaterMeter wm)
|
||||
public static unsafe int ClosePort(IperlHead iperlHead)
|
||||
{
|
||||
if (wm.DebugLevel != DebugMode.Normal) return 0; /// No function in debug mode
|
||||
if (iperlHead.DebugLevel != DebugMode.Normal) return 0; /// No function in debug mode
|
||||
|
||||
if (wm.RfidComPortNr > 0)
|
||||
if (iperlHead.RfidComPortNr > 0)
|
||||
{
|
||||
return closePort1();
|
||||
}
|
||||
else
|
||||
{
|
||||
switch (wm.MuxBoardNr)
|
||||
switch (iperlHead.MuxBoardNr)
|
||||
{
|
||||
default:
|
||||
case 1: return closePort1();
|
||||
@@ -126,11 +126,11 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
/// Wrapper function with safe interface and unsafe body
|
||||
/// </summary>
|
||||
/// <returns>Value returned by readRequestPort(...)</returns>
|
||||
public static unsafe int ReadRequestPort(WaterMeters.iPerl.WaterMeter wm, MessageID messageID, int offset, int lenght, out byte[] buffer, int timeout)
|
||||
public static unsafe int ReadRequestPort(IperlHead iperlHead, MessageID messageID, int offset, int lenght, out byte[] buffer, int timeout)
|
||||
{
|
||||
buffer = new byte[lenght];
|
||||
|
||||
if (wm.DebugLevel != DebugMode.Normal) return wm.Name.Equals("iPerl13") ? 2 : 0; /// Simulates an error on position 13
|
||||
if (iperlHead.DebugLevel != DebugMode.Normal) return iperlHead.Name.Equals("iPerl13") ? 2 : 0; /// Simulates an error on position 13
|
||||
|
||||
|
||||
byte[] buf = new byte[200];
|
||||
@@ -139,13 +139,13 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
{
|
||||
int retv;
|
||||
|
||||
if (wm.RfidComPortNr > 0)
|
||||
if (iperlHead.RfidComPortNr > 0)
|
||||
{
|
||||
retv = readRequestPort1(messageID, offset, lenght, pBuf, timeout);
|
||||
}
|
||||
else
|
||||
{
|
||||
switch (wm.MuxBoardNr)
|
||||
switch (iperlHead.MuxBoardNr)
|
||||
{
|
||||
default:
|
||||
case 1: retv = readRequestPort1(messageID, offset, lenght, pBuf, timeout); break;
|
||||
@@ -160,11 +160,11 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
///
|
||||
/// Logging
|
||||
///
|
||||
string name = string.Format("{0}({1})", wm.Name, wm.SerialNr);
|
||||
if ((messageID == MessageID.Configuration) && (offset == 0) && (lenght == WaterMeters.iPerl.ConfigStruct.Length))
|
||||
rfidDataLogger.InfoFormat("{0}: ReadRequestPort({1},...) returned {2} {3}", name, messageID, retv, (retv != 0) ? "!" : WaterMeters.iPerl.ConfigStruct.FromByteArray(buffer).ToString());
|
||||
else if ((messageID == MessageID.Calibration) && (offset == 0) && (lenght == WaterMeters.iPerl.CalibrationStruct.Length))
|
||||
rfidDataLogger.InfoFormat("{0}: ReadRequestPort({1},...) returned {2} {3}", name, messageID, retv, (retv != 0) ? "!" : WaterMeters.iPerl.CalibrationStruct.FromByteArray(buffer).ToString());
|
||||
string name = string.Format("{0}({1})", iperlHead.Name, iperlHead.SerialNr);
|
||||
if ((messageID == MessageID.Configuration) && (offset == 0) && (lenght == ConfigStruct.Length))
|
||||
rfidDataLogger.InfoFormat("{0}: ReadRequestPort({1},...) returned {2} {3}", name, messageID, retv, (retv != 0) ? "!" : ConfigStruct.FromByteArray(buffer).ToString());
|
||||
else if ((messageID == MessageID.Calibration) && (offset == 0) && (lenght == CalibrationStruct.Length))
|
||||
rfidDataLogger.InfoFormat("{0}: ReadRequestPort({1},...) returned {2} {3}", name, messageID, retv, (retv != 0) ? "!" : CalibrationStruct.FromByteArray(buffer).ToString());
|
||||
else if ((messageID == MessageID.Calibration) && (offset == 2) && (lenght == 2))
|
||||
rfidDataLogger.InfoFormat("{0}: ReadRequestPort({1},2,2,...) returned {2} {3}", name, messageID, retv, (retv != 0) ? "!" : string.Format("Cal={0}", buf[0] + 256 * buf[1]));
|
||||
else
|
||||
@@ -178,21 +178,21 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
/// Wrapper function with safe interface adn unsafe body
|
||||
/// </summary>
|
||||
/// <returns>Value returned by writeRequestPort(...)</returns>
|
||||
public static unsafe int WriteRequestPort(WaterMeters.iPerl.WaterMeter wm, MessageID messageID, int offset, int lenght, byte[] buffer, int timeout)
|
||||
public static unsafe int WriteRequestPort(IperlHead iperlHead, MessageID messageID, int offset, int lenght, byte[] buffer, int timeout)
|
||||
{
|
||||
if (wm.DebugLevel != DebugMode.Normal) return 0;
|
||||
if (iperlHead.DebugLevel != DebugMode.Normal) return 0;
|
||||
|
||||
fixed (byte* pBuf = buffer)
|
||||
{
|
||||
int retv;
|
||||
|
||||
if (wm.RfidComPortNr > 0)
|
||||
if (iperlHead.RfidComPortNr > 0)
|
||||
{
|
||||
retv = writeRequestPort1(messageID, offset, lenght, pBuf, timeout);
|
||||
}
|
||||
else
|
||||
{
|
||||
switch (wm.MuxBoardNr)
|
||||
switch (iperlHead.MuxBoardNr)
|
||||
{
|
||||
default:
|
||||
case 1: retv = writeRequestPort1(messageID, offset, lenght, pBuf, timeout); break;
|
||||
@@ -207,7 +207,7 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
///
|
||||
/// Logging
|
||||
///
|
||||
string name = string.Format("{0}({1})", wm.Name, wm.SerialNr);
|
||||
string name = string.Format("{0}({1})", iperlHead.Name, iperlHead.SerialNr);
|
||||
if (lenght == 1)
|
||||
rfidDataLogger.InfoFormat("{0}: WriteRequestPort({2}, {3}, {4}, {5}) returned {1} {6}", name, retv, messageID, offset, lenght, pBuf[0].ToString("X2"), (retv != 0) ? "!" : "");
|
||||
else if (lenght == 2)
|
||||
@@ -260,7 +260,7 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
PictureBox[] counters;
|
||||
TextBox[] messages;
|
||||
|
||||
static IList<WaterMeters.iPerl.WaterMeter> waterMeters;
|
||||
static IList<IperlHead> iperlHeads;
|
||||
static IList<int> waterMeterPositions; /// keeps original indices in RegisterReaders list
|
||||
|
||||
Modbus.QuidoRS.QuidoRS quido;
|
||||
@@ -331,7 +331,11 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
wmTextBox46, wmTextBox47, wmTextBox48,
|
||||
};
|
||||
|
||||
formCompleted = false;
|
||||
/// Initialize lists
|
||||
iperlHeads = new List<IperlHead>();
|
||||
waterMeterPositions = new List<int>();
|
||||
|
||||
formCompleted = false;
|
||||
|
||||
startTime = DateTime.Now;
|
||||
startTimeSec = StateMachine.Time;
|
||||
@@ -412,21 +416,18 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
|
||||
void ConstructorCommon()
|
||||
{
|
||||
waterMeters = new List<WaterMeters.iPerl.WaterMeter>();
|
||||
waterMeterPositions = new List<int>();
|
||||
///
|
||||
for (int wmPos = 0; wmPos < ProcessData.RegisterReaders.Length; wmPos++)
|
||||
{
|
||||
WaterMeters.iPerl.WaterMeter iPerl = ProcessData.RegisterReaders[wmPos] as WaterMeters.iPerl.WaterMeter;
|
||||
IperlHead iperlHead = ProcessData.RegisterReaders[wmPos] as IperlHead;
|
||||
|
||||
if (iPerl != null)
|
||||
if (iperlHead != null)
|
||||
{
|
||||
waterMeters.Add(iPerl);
|
||||
iperlHeads.Add(iperlHead);
|
||||
waterMeterPositions.Add(wmPos);
|
||||
}
|
||||
}
|
||||
|
||||
WaterMetersCount = waterMeters.Count;
|
||||
WaterMetersCount = iperlHeads.Count;
|
||||
|
||||
ShuffleTextBoxes(WaterMetersCount, Config.Data.LineSize);
|
||||
|
||||
@@ -442,7 +443,7 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
completedCommCount = 0;
|
||||
stopWorkerThreads = false;
|
||||
|
||||
foreach (var iPerl in iPerlCommunicationForm.waterMeters)
|
||||
foreach (var iPerl in iPerlCommunicationForm.iperlHeads)
|
||||
{
|
||||
if (!rfidPortNrs.Contains(iPerl.MuxBoardNr))
|
||||
{
|
||||
@@ -510,9 +511,9 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
void Localize()
|
||||
{
|
||||
Text = Strings.Water_Meter_States;
|
||||
for (int i = 0; i < Math.Min(textBoxesCount, waterMeters.Count); i++)
|
||||
for (int i = 0; i < Math.Min(textBoxesCount, iperlHeads.Count); i++)
|
||||
{
|
||||
labels[i].Text = waterMeters[i].Name;
|
||||
labels[i].Text = iperlHeads[i].Name;
|
||||
}
|
||||
}
|
||||
|
||||
@@ -541,9 +542,9 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
Top = (ls.iPerlCommunicationsFormTop != 0) ? ls.iPerlCommunicationsFormTop : 150;
|
||||
|
||||
/// Reset opto-data indication
|
||||
for (int i = 0; i < waterMeters.Count; i++)
|
||||
for (int i = 0; i < iperlHeads.Count; i++)
|
||||
{
|
||||
waterMeters[i].FlushedDataCount = 0;
|
||||
iperlHeads[i].FlushedDataCount = 0;
|
||||
counters[i].BackColor = Color.Red;
|
||||
}
|
||||
|
||||
@@ -661,26 +662,29 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
int wmNr = 0;
|
||||
bool wmFound = false;
|
||||
|
||||
foreach (var wm in waterMeters)
|
||||
for (int j = 0; j < iperlHeads.Count; j++)
|
||||
{
|
||||
if ((wm.MuxBoardNr == rfidPortNr) && (wm.Group == group))
|
||||
IperlHead ihead = iperlHeads[j];
|
||||
|
||||
if ((ihead.MuxBoardNr == rfidPortNr) && (ihead.Group == group))
|
||||
{
|
||||
wmFound = true;
|
||||
WaterMeters.WaterMeter.WaterMeter wm = SequenceBase.WaterMeters[waterMeterPositions[j]] as WaterMeters.WaterMeter.WaterMeter; /// WaterMeters.WaterMeter.WaterMeter implements iPerl specific variables
|
||||
|
||||
CommErr error;
|
||||
string resultStr = string.Empty;
|
||||
|
||||
if (activity.ToLower().Contains(ReadConfigurationStr.ToLower())) error = ReadConfiguration(wm, ref resultStr);
|
||||
else if (activity.ToLower().Contains(SetTestModeStr.ToLower())) error = SetTestMode(wm, ref resultStr);
|
||||
else if (activity.ToLower().Equals(SetActiveModeStr.ToLower())) error = SetActiveMode(wm, ref resultStr);
|
||||
else if (activity.ToLower().Equals(ReadCalibrationStr.ToLower())) error = ReadCalibration(wm, ref resultStr);
|
||||
else if (activity.ToLower().Contains(WriteCalibrationFactorStr.ToLower())) error = WriteCalibrationFactor(wm, ref resultStr);
|
||||
else if (activity.ToLower().Equals(NormalizeCalibrationFactorStr.ToLower())) error = NormalizeCalibrationFactor(wm, ref resultStr);
|
||||
else if (activity.ToLower().Equals(ResetQ2CorrectionStr.ToLower())) error = ResetQ2Correction(wm, ref resultStr);
|
||||
else if (activity.ToLower().Equals(WriteQ2CorrectionStr.ToLower())) error = WriteQ2Correction(wm, ref resultStr, false); /// standard iPerl
|
||||
else if (activity.ToLower().Equals(WriteQ2CorrectionAltStr.ToLower())) error = WriteQ2Correction(wm, ref resultStr, true); /// DEWA iPerl
|
||||
else if (activity.ToLower().Equals(Reset2HzCorrectionStr.ToLower())) error = Reset2HzCorrection(wm, ref resultStr);
|
||||
else if (activity.ToLower().Equals(Write2HzCorrectionStr.ToLower())) error = Write2HzCorrection(wm, ref resultStr);
|
||||
if (activity.ToLower().Contains(ReadConfigurationStr.ToLower())) error = ReadConfiguration(ihead, wm, ref resultStr);
|
||||
else if (activity.ToLower().Contains(SetTestModeStr.ToLower())) error = SetTestMode(ihead, wm, ref resultStr);
|
||||
else if (activity.ToLower().Equals(SetActiveModeStr.ToLower())) error = SetActiveMode(ihead, wm, ref resultStr);
|
||||
else if (activity.ToLower().Equals(ReadCalibrationStr.ToLower())) error = ReadCalibration(ihead, wm, ref resultStr);
|
||||
else if (activity.ToLower().Contains(WriteCalibrationFactorStr.ToLower())) error = WriteCalibrationFactor(ihead, wm, ref resultStr);
|
||||
else if (activity.ToLower().Equals(NormalizeCalibrationFactorStr.ToLower())) error = NormalizeCalibrationFactor(ihead, wm, ref resultStr);
|
||||
else if (activity.ToLower().Equals(ResetQ2CorrectionStr.ToLower())) error = ResetQ2Correction(ihead, wm, ref resultStr);
|
||||
else if (activity.ToLower().Equals(WriteQ2CorrectionStr.ToLower())) error = WriteQ2Correction(ihead, wm, ref resultStr, false); /// standard iPerl
|
||||
else if (activity.ToLower().Equals(WriteQ2CorrectionAltStr.ToLower())) error = WriteQ2Correction(ihead, wm, ref resultStr, true); /// DEWA iPerl
|
||||
else if (activity.ToLower().Equals(Reset2HzCorrectionStr.ToLower())) error = Reset2HzCorrection(ihead, wm, ref resultStr);
|
||||
else if (activity.ToLower().Equals(Write2HzCorrectionStr.ToLower())) error = Write2HzCorrection(ihead, wm, ref resultStr);
|
||||
else
|
||||
{
|
||||
error = CommErr.None;
|
||||
@@ -692,20 +696,20 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
{
|
||||
OnCommCompleted(null, new CommCompletedEventArgs(threadId, wmNr, resultStr));
|
||||
}
|
||||
else if (wm.CommFailed || error == CommErr.CommFailed)
|
||||
else if (ihead.CommFailed || error == CommErr.CommFailed)
|
||||
{
|
||||
OnCommCompleted(null, new CommCompletedEventArgs(threadId, wmNr, "Watermeter is disabled"));
|
||||
}
|
||||
else
|
||||
{
|
||||
OnCommCompleted(null, new CommCompletedEventArgs(threadId, wmNr, string.Format("{0} failed ({1}) !!!", activity, error)));
|
||||
rfidDataLogger.ErrorFormat("Group={0}, Board={1}, {2} failed ({3}) !!!", currentGroup, wm.MuxBoardNr, activity, error);
|
||||
wm.CommFailed = true;
|
||||
rfidDataLogger.ErrorFormat("Group={0}, Board={1}, {2} failed ({3}) !!!", currentGroup, ihead.MuxBoardNr, activity, error);
|
||||
ihead.CommFailed = true;
|
||||
}
|
||||
break;
|
||||
}
|
||||
wmNr++;
|
||||
TBF.UiBridge.Bridge.OnTestProgress(null, new TBF.UiBridge.TestProgressEventArgs(tests[i], Config.Entities.Progress.FlowSetting));
|
||||
TBF.UiBridge.Bridge.OnTestProgress(null, new TBF.UiBridge.TestProgressEventArgs(tests[i], Config.Entities.Progress.FlowSetting));
|
||||
}
|
||||
|
||||
if (!wmFound)
|
||||
@@ -730,10 +734,10 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
/// <summary>
|
||||
/// Read a complete configuration structure of the watermeter
|
||||
/// </summary>
|
||||
/// <param name="wm">Water meter object</param>
|
||||
/// <param name="ihead">Water meter object</param>
|
||||
/// <param name="resultStr">String passed to caller</param>
|
||||
/// <returns>true on success</returns>
|
||||
static CommErr ReadConfiguration(WaterMeters.iPerl.WaterMeter wm, ref string resultStr)
|
||||
static CommErr ReadConfiguration(IperlHead ihead, WaterMeters.WaterMeter.WaterMeter wm, ref string resultStr)
|
||||
{
|
||||
///
|
||||
/// The activity is "Read configuration" (this enables the watermeter, resets error flag)
|
||||
@@ -741,12 +745,12 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
///
|
||||
if (!multiTestParams[currentActivityStep].Activity.ToLower().Contains(" if enabled"))
|
||||
{
|
||||
wm.CommFailed = false;
|
||||
ihead.CommFailed = false;
|
||||
}
|
||||
|
||||
if (wm.CommFailed) return CommErr.CommFailed;
|
||||
if (ihead.CommFailed) return CommErr.CommFailed;
|
||||
|
||||
if (OpenPort(wm) != 0) return CommErr.OpenPort; /// Open RFID port
|
||||
if (OpenPort(ihead) != 0) return CommErr.OpenPort; /// Open RFID port
|
||||
|
||||
CommErr error = CommErr.Read;
|
||||
|
||||
@@ -754,16 +758,16 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
byte[] config = null;
|
||||
for (int j = 0; j < cfg.MaxCommRetries; j++)
|
||||
{
|
||||
if (0 == ReadRequestPort(wm, MessageID.Configuration, 0, ConfigStruct.Length, out config, cfg.CommTimeout))
|
||||
if (0 == ReadRequestPort(ihead, MessageID.Configuration, 0, ConfigStruct.Length, out config, cfg.CommTimeout))
|
||||
{
|
||||
error = CommErr.None;
|
||||
wm.ConfigStruct = ConfigStruct.FromByteArray(config);
|
||||
resultStr = wm.ConfigStruct.ToString(1);
|
||||
ihead.ConfigStruct = ConfigStruct.FromByteArray(config);
|
||||
resultStr = ihead.ConfigStruct.ToString(1);
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
||||
ClosePort(wm); /// Close RFID port
|
||||
ClosePort(ihead); /// Close RFID port
|
||||
|
||||
return error;
|
||||
}
|
||||
@@ -775,12 +779,12 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
/// whether the testModeConfig is correctly set, if necessary it is changed to the specified value.
|
||||
/// Read a part of configuration afterwards to verify the mode was set correctly.
|
||||
/// </summary>
|
||||
/// <param name="wm">Water meter object</param>
|
||||
/// <param name="ihead">Water meter object</param>
|
||||
/// <param name="resultStr">String passed to caller</param>
|
||||
/// <returns>true on success</returns>
|
||||
static CommErr SetTestMode(WaterMeters.iPerl.WaterMeter wm, ref string resultStr)
|
||||
static CommErr SetTestMode(IperlHead ihead, WaterMeters.WaterMeter.WaterMeter wm, ref string resultStr)
|
||||
{
|
||||
if (wm.CommFailed) return CommErr.CommFailed;
|
||||
if (ihead.CommFailed) return CommErr.CommFailed;
|
||||
|
||||
Byte testModeConfig = 0xA0; /// Default value
|
||||
///
|
||||
@@ -794,41 +798,41 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
}
|
||||
}
|
||||
|
||||
if (wm.ConfigStruct.MeterState == MeterState.Test && wm.ConfigStruct.TestModeConfig == testModeConfig)
|
||||
if (ihead.ConfigStruct.MeterState == MeterState.Test && ihead.ConfigStruct.TestModeConfig == testModeConfig)
|
||||
{
|
||||
/// Already in the correct test mode
|
||||
resultStr = "Already " + wm.ConfigStruct.ToString(1);
|
||||
resultStr = "Already " + ihead.ConfigStruct.ToString(1);
|
||||
return CommErr.None;
|
||||
}
|
||||
|
||||
/// Communication necessary
|
||||
if (OpenPort(wm) != 0) return CommErr.OpenPort; /// Open RFID port
|
||||
if (OpenPort(ihead) != 0) return CommErr.OpenPort; /// Open RFID port
|
||||
|
||||
CommErr error = CommErr.None;
|
||||
|
||||
if (error==CommErr.None && (wm.ConfigStruct.TestModeConfig != testModeConfig) && (wm.ConfigStruct.MeterState != MeterState.Active))
|
||||
if (error==CommErr.None && (ihead.ConfigStruct.TestModeConfig != testModeConfig) && (ihead.ConfigStruct.MeterState != MeterState.Active))
|
||||
{
|
||||
/// Switch to Active mode in order to change TestModeConfig
|
||||
error = CommErr.CmdActive;
|
||||
byte[] cmd = new byte[1] { (byte)6 };
|
||||
for (int j = 0; j < cfg.MaxCommRetries; j++)
|
||||
{
|
||||
if (0 == WriteRequestPort(wm, MessageID.Command, 0, 1, cmd, cfg.CommTimeout)) { error = CommErr.None; break; }
|
||||
if (0 == WriteRequestPort(ihead, MessageID.Command, 0, 1, cmd, cfg.CommTimeout)) { error = CommErr.None; break; }
|
||||
}
|
||||
|
||||
Thread.Sleep(250);
|
||||
}
|
||||
|
||||
if (error == CommErr.None && (wm.ConfigStruct.TestModeConfig != testModeConfig))
|
||||
if (error == CommErr.None && (ihead.ConfigStruct.TestModeConfig != testModeConfig))
|
||||
{
|
||||
/// Change the TestModeConfig if necessary
|
||||
error = CommErr.Write;
|
||||
byte[] tstMdCfg = new byte[1] { testModeConfig };
|
||||
for (int j = 0; j < cfg.MaxCommRetries; j++)
|
||||
{
|
||||
if (0 == WriteRequestPort(wm, MessageID.Configuration, 21, 1, tstMdCfg, cfg.CommTimeout))
|
||||
if (0 == WriteRequestPort(ihead, MessageID.Configuration, 21, 1, tstMdCfg, cfg.CommTimeout))
|
||||
{
|
||||
wm.ConfigStruct.Update(21, tstMdCfg);
|
||||
ihead.ConfigStruct.Update(21, tstMdCfg);
|
||||
error = CommErr.None;
|
||||
break;
|
||||
}
|
||||
@@ -844,7 +848,7 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
byte[] cmd = new byte[1] { (byte)7 };
|
||||
for (int j = 0; j < cfg.MaxCommRetries; j++)
|
||||
{
|
||||
if (0 == WriteRequestPort(wm, MessageID.Command, 0, 1, cmd, cfg.CommTimeout)) { error = CommErr.None; break; }
|
||||
if (0 == WriteRequestPort(ihead, MessageID.Command, 0, 1, cmd, cfg.CommTimeout)) { error = CommErr.None; break; }
|
||||
}
|
||||
|
||||
Thread.Sleep(250);
|
||||
@@ -858,20 +862,20 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
byte[] cfg_0_3 = null;
|
||||
for (int j = 0; j < cfg.MaxCommRetries; j++)
|
||||
{
|
||||
if (0 == ReadRequestPort(wm, MessageID.Configuration, 0, 4, out cfg_0_3, cfg.CommTimeout))
|
||||
if (0 == ReadRequestPort(ihead, MessageID.Configuration, 0, 4, out cfg_0_3, cfg.CommTimeout))
|
||||
{
|
||||
wm.ConfigStruct.Update(0, cfg_0_3);
|
||||
if (wm.ConfigStruct.MeterState == MeterState.Test)
|
||||
ihead.ConfigStruct.Update(0, cfg_0_3);
|
||||
if (ihead.ConfigStruct.MeterState == MeterState.Test)
|
||||
{
|
||||
error = CommErr.None;
|
||||
resultStr = wm.ConfigStruct.ToString(1);
|
||||
resultStr = ihead.ConfigStruct.ToString(1);
|
||||
break;
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
ClosePort(wm); /// Close RFID port
|
||||
ClosePort(ihead); /// Close RFID port
|
||||
|
||||
return error;
|
||||
}
|
||||
@@ -881,12 +885,12 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
/// Set the watermeter to the active mode.
|
||||
/// Read a part of configuration afterwards to verify the mode was set correctly.
|
||||
/// </summary>
|
||||
/// <param name="wm">Water meter object</param>
|
||||
/// <param name="ihead">Water meter object</param>
|
||||
/// <param name="resultStr">String passed to caller</param>
|
||||
/// <returns>true on success</returns>
|
||||
static CommErr SetActiveMode(WaterMeters.iPerl.WaterMeter wm, ref string resultStr)
|
||||
static CommErr SetActiveMode(IperlHead ihead, WaterMeters.WaterMeter.WaterMeter wm, ref string resultStr)
|
||||
{
|
||||
if (OpenPort(wm) != 0) return CommErr.OpenPort; /// Open RFID port
|
||||
if (OpenPort(ihead) != 0) return CommErr.OpenPort; /// Open RFID port
|
||||
|
||||
CommErr error = CommErr.CmdActive;
|
||||
|
||||
@@ -894,7 +898,7 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
byte[] cmd = new byte[1] { (byte)6 };
|
||||
for (int j = 0; j < cfg.MaxCommRetries; j++)
|
||||
{
|
||||
if (0 == WriteRequestPort(wm, MessageID.Command, 0, 1, cmd, cfg.CommTimeout))
|
||||
if (0 == WriteRequestPort(ihead, MessageID.Command, 0, 1, cmd, cfg.CommTimeout))
|
||||
{
|
||||
error = CommErr.None;
|
||||
break;
|
||||
@@ -928,14 +932,14 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
#else
|
||||
if (error == CommErr.None)
|
||||
{
|
||||
if (wm.ConfigStruct == null)
|
||||
if (ihead.ConfigStruct == null)
|
||||
resultStr = "OK (Config not available)";
|
||||
else
|
||||
resultStr = wm.ConfigStruct.ToString(1);
|
||||
resultStr = ihead.ConfigStruct.ToString(1);
|
||||
}
|
||||
#endif
|
||||
|
||||
ClosePort(wm); /// Close RFID port
|
||||
ClosePort(ihead); /// Close RFID port
|
||||
|
||||
return error;
|
||||
}
|
||||
@@ -944,14 +948,14 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
/// <summary>
|
||||
/// Read a complete calibration structure from the watermeter
|
||||
/// </summary>
|
||||
/// <param name="wm">Water meter object</param>
|
||||
/// <param name="ihead">Water meter object</param>
|
||||
/// <param name="resultStr">String passed to caller</param>
|
||||
/// <returns>true on success</returns>
|
||||
static CommErr ReadCalibration(WaterMeters.iPerl.WaterMeter wm, ref string resultStr)
|
||||
static CommErr ReadCalibration(IperlHead ihead, WaterMeters.WaterMeter.WaterMeter wm, ref string resultStr)
|
||||
{
|
||||
if (wm.CommFailed) return CommErr.CommFailed;
|
||||
if (ihead.CommFailed) return CommErr.CommFailed;
|
||||
|
||||
if (OpenPort(wm) != 0) return CommErr.OpenPort; /// Open RFID port
|
||||
if (OpenPort(ihead) != 0) return CommErr.OpenPort; /// Open RFID port
|
||||
|
||||
CommErr error = CommErr.Read;
|
||||
|
||||
@@ -959,16 +963,19 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
byte[] calib = null;
|
||||
for (int j = 0; j < cfg.MaxCommRetries; j++)
|
||||
{
|
||||
if (0 == ReadRequestPort(wm, MessageID.Calibration, 0, CalibrationStruct.Length, out calib, cfg.CommTimeout))
|
||||
if (0 == ReadRequestPort(ihead, MessageID.Calibration, 0, CalibrationStruct.Length, out calib, cfg.CommTimeout))
|
||||
{
|
||||
wm.CalibrationStruct = CalibrationStruct.FromByteArray(calib);
|
||||
resultStr = wm.CalibrationStruct.ToString();
|
||||
error = wm.VerifyIPerlType() ? CommErr.None : CommErr.WrongIPerlType;
|
||||
ihead.CalibrationStruct = CalibrationStruct.FromByteArray(calib);
|
||||
#if IPERL
|
||||
if (wm != null && wm.OriginalCalibFactor == 0) wm.OriginalCalibFactor = ihead.CalibrationStruct.Calibration;
|
||||
#endif
|
||||
resultStr = ihead.CalibrationStruct.ToString();
|
||||
error = ihead.VerifyIPerlType() ? CommErr.None : CommErr.WrongIPerlType;
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
||||
ClosePort(wm); /// Close RFID port
|
||||
ClosePort(ihead); /// Close RFID port
|
||||
|
||||
return error;
|
||||
}
|
||||
@@ -978,12 +985,12 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
/// Write the calculated calibration factor to the water meter.
|
||||
/// Read a part of CalibrationStruct afterwards to verify factor was written correctly.
|
||||
/// </summary>
|
||||
/// <param name="wm">Water meter object</param>
|
||||
/// <param name="ihead">Water meter object</param>
|
||||
/// <param name="resultStr">String passed to caller</param>
|
||||
/// <returns>true on success</returns>
|
||||
static CommErr WriteCalibrationFactor(WaterMeters.iPerl.WaterMeter wm, ref string resultStr)
|
||||
static CommErr WriteCalibrationFactor(IperlHead ihead, WaterMeters.WaterMeter.WaterMeter wm, ref string resultStr)
|
||||
{
|
||||
if (wm.CommFailed) return CommErr.CommFailed;
|
||||
if (ihead.CommFailed) return CommErr.CommFailed;
|
||||
|
||||
///
|
||||
/// Parse calibration factor (1 argument) or calibration factor limits (2 arguments)
|
||||
@@ -1002,7 +1009,7 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
UInt16.TryParse(arguments[0], out factorLimitLo) && factorLimitLo > 0 &&
|
||||
UInt16.TryParse(arguments[1], out factorLimitHi) && factorLimitHi > 0)
|
||||
{
|
||||
newCalibFactor = wm.CalculateNewCalibFactor(wm.CalibrationFactor, factorLimitLo, factorLimitHi);
|
||||
newCalibFactor = ihead.CalculateNewCalibFactor(ihead.CalibrationFactor, factorLimitLo, factorLimitHi);
|
||||
}
|
||||
else if (arguments.Length == 1 && UInt16.TryParse(arguments[0], out val) && val > 0)
|
||||
{
|
||||
@@ -1010,12 +1017,12 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
}
|
||||
else
|
||||
{
|
||||
newCalibFactor = wm.CalculateNewCalibFactor(wm.CalibrationFactor, wm.FactorLimitLo, wm.FactorLimitHi);
|
||||
newCalibFactor = ihead.CalculateNewCalibFactor(ihead.CalibrationFactor, ihead.FactorLimitLo, ihead.FactorLimitHi);
|
||||
}
|
||||
}
|
||||
else
|
||||
{
|
||||
newCalibFactor = wm.CalculateNewCalibFactor(wm.CalibrationFactor, wm.FactorLimitLo, wm.FactorLimitHi);
|
||||
newCalibFactor = ihead.CalculateNewCalibFactor(ihead.CalibrationFactor, ihead.FactorLimitLo, ihead.FactorLimitHi);
|
||||
}
|
||||
|
||||
if (newCalibFactor == 0) return CommErr.CalibFactorOoRange;
|
||||
@@ -1023,7 +1030,7 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
///
|
||||
/// Start communication with iPerl
|
||||
///
|
||||
if (OpenPort(wm) != 0) return CommErr.OpenPort; /// Open RFID port
|
||||
if (OpenPort(ihead) != 0) return CommErr.OpenPort; /// Open RFID port
|
||||
|
||||
CommErr error;
|
||||
byte[] data = new byte[2] { (byte)(newCalibFactor & 0x00FF), (byte)((newCalibFactor >> 8) & 0x00FF) };
|
||||
@@ -1034,31 +1041,34 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
/// Write the new calibration factor (up to cfg.MaxCommRetries tims)
|
||||
///
|
||||
error = CommErr.Write;
|
||||
if (0 == WriteRequestPort(wm, MessageID.Calibration, 2, 2, data, cfg.CommTimeout))
|
||||
if (0 == WriteRequestPort(ihead, MessageID.Calibration, 2, 2, data, cfg.CommTimeout))
|
||||
{
|
||||
///
|
||||
/// Read and verify the calibration factor
|
||||
///
|
||||
error = CommErr.ReadAfterWrite;
|
||||
byte[] calib_2_3 = null;
|
||||
if (0 == ReadRequestPort(wm, MessageID.Calibration, 2, 2, out calib_2_3, cfg.CommTimeout))
|
||||
if (0 == ReadRequestPort(ihead, MessageID.Calibration, 2, 2, out calib_2_3, cfg.CommTimeout))
|
||||
{
|
||||
error = CommErr.Verify;
|
||||
if (calib_2_3 != null && calib_2_3.Length == 2 && data[0] == calib_2_3[0] && data[1] == calib_2_3[1])
|
||||
{
|
||||
error = CommErr.None;
|
||||
wm.CalibrationStruct.Update(data, 2);
|
||||
resultStr = wm.CalibrationStruct.ToString();
|
||||
ihead.CalibrationStruct.Update(data, 2);
|
||||
#if IPERL
|
||||
if (wm != null) wm.CalibFactor = newCalibFactor;
|
||||
#endif
|
||||
resultStr = ihead.CalibrationStruct.ToString();
|
||||
break;
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
wm.CalibrationStruct.Update(data, 2);
|
||||
ihead.CalibrationStruct.Update(data, 2);
|
||||
}
|
||||
while (++writeAndVerifyRetries <= cfg.MaxCommRetries);
|
||||
|
||||
ClosePort(wm); /// Close RFID port
|
||||
ClosePort(ihead); /// Close RFID port
|
||||
|
||||
return error;
|
||||
}
|
||||
@@ -1067,26 +1077,26 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
/// <summary>
|
||||
/// Normalize calibration factor in case ti is close to value 8000.
|
||||
/// </summary>
|
||||
/// <param name="wm">Water meter object</param>
|
||||
/// <param name="ihead">Water meter object</param>
|
||||
/// <param name="resultStr">String passed to caller</param>
|
||||
/// <returns>true on success</returns>
|
||||
static CommErr NormalizeCalibrationFactor(WaterMeters.iPerl.WaterMeter wm, ref string resultStr)
|
||||
static CommErr NormalizeCalibrationFactor(IperlHead ihead, WaterMeters.WaterMeter.WaterMeter wm, ref string resultStr)
|
||||
{
|
||||
if (wm.CommFailed) return CommErr.CommFailed;
|
||||
if (ihead.CommFailed) return CommErr.CommFailed;
|
||||
|
||||
if (wm.CalibrationFactor <= 5000)
|
||||
if (ihead.CalibrationFactor <= 5000)
|
||||
{
|
||||
resultStr = "Calibratin factor is OK";
|
||||
return CommErr.None; /// No need to update the calibration factor
|
||||
}
|
||||
|
||||
if (OpenPort(wm) != 0) return CommErr.OpenPort; /// Open RFID port
|
||||
if (OpenPort(ihead) != 0) return CommErr.OpenPort; /// Open RFID port
|
||||
|
||||
CommErr error = CommErr.Write;
|
||||
|
||||
/// Determine the new calibration factor
|
||||
UInt16 newCalibFactor = 0;
|
||||
switch (wm.CalibrationStruct.MeterType)
|
||||
switch (ihead.CalibrationStruct.MeterType)
|
||||
{
|
||||
case MeterType.DN15: newCalibFactor = 2650; break;
|
||||
case MeterType.DN20: newCalibFactor = 3746; break;
|
||||
@@ -1104,10 +1114,10 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
byte[] data = new byte[2] { (byte)(newCalibFactor & 0x00FF), (byte)((newCalibFactor >> 8) & 0x00FF) };
|
||||
for (int j = 0; j < cfg.MaxCommRetries; j++)
|
||||
{
|
||||
if (0 == WriteRequestPort(wm, MessageID.Calibration, 2, 2, data, cfg.CommTimeout))
|
||||
if (0 == WriteRequestPort(ihead, MessageID.Calibration, 2, 2, data, cfg.CommTimeout))
|
||||
{
|
||||
error = CommErr.None;
|
||||
wm.CalibrationStruct.Update(data, 2);
|
||||
ihead.CalibrationStruct.Update(data, 2);
|
||||
break;
|
||||
}
|
||||
}
|
||||
@@ -1120,17 +1130,17 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
byte[] calib_2_3 = null;
|
||||
for (int j = 0; j < cfg.MaxCommRetries; j++)
|
||||
{
|
||||
if (0 == ReadRequestPort(wm, MessageID.Calibration, 2, 2, out calib_2_3, cfg.CommTimeout))
|
||||
if (0 == ReadRequestPort(ihead, MessageID.Calibration, 2, 2, out calib_2_3, cfg.CommTimeout))
|
||||
{
|
||||
error = CommErr.None;
|
||||
wm.CalibrationStruct.Update(calib_2_3, 2);
|
||||
resultStr = wm.CalibrationStruct.ToString();
|
||||
ihead.CalibrationStruct.Update(calib_2_3, 2);
|
||||
resultStr = ihead.CalibrationStruct.ToString();
|
||||
break;
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
ClosePort(wm); /// Close RFID port
|
||||
ClosePort(ihead); /// Close RFID port
|
||||
|
||||
return error;
|
||||
}
|
||||
@@ -1144,14 +1154,14 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
/// Reset both Q2 correction factors in the memory to 0.
|
||||
/// Read them back to verify factors were written correctly.
|
||||
/// </summary>
|
||||
/// <param name="wm">Water meter object</param>
|
||||
/// <param name="ihead">Water meter object</param>
|
||||
/// <param name="resultStr">String passed to caller</param>
|
||||
/// <returns>true on success</returns>
|
||||
static CommErr ResetQ2Correction(WaterMeters.iPerl.WaterMeter wm, ref string resultStr)
|
||||
static CommErr ResetQ2Correction(IperlHead ihead, WaterMeters.WaterMeter.WaterMeter wm, ref string resultStr)
|
||||
{
|
||||
if (wm.CommFailed) return CommErr.CommFailed;
|
||||
if (ihead.CommFailed) return CommErr.CommFailed;
|
||||
|
||||
if (OpenPort(wm) != 0) return CommErr.OpenPort; /// Open RFID port
|
||||
if (OpenPort(ihead) != 0) return CommErr.OpenPort; /// Open RFID port
|
||||
|
||||
CommErr error = CommErr.Write;
|
||||
|
||||
@@ -1160,7 +1170,7 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
///
|
||||
for (int j = 0; j < cfg.MaxCommRetries; j++)
|
||||
{
|
||||
if (0 == WriteRequestPort(wm, MessageID.MetrologyMemory, Q2CorrFactorsAddr, wrData.Length, wrData, cfg.CommTimeout))
|
||||
if (0 == WriteRequestPort(ihead, MessageID.MetrologyMemory, Q2CorrFactorsAddr, wrData.Length, wrData, cfg.CommTimeout))
|
||||
{
|
||||
error = CommErr.None;
|
||||
break;
|
||||
@@ -1194,11 +1204,11 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
if (error == CommErr.None)
|
||||
{
|
||||
resultStr = "Q2 corrections reset to 0";
|
||||
wm.Q2CorrRFlow = 0;
|
||||
ihead.Q2CorrRFlow = 0;
|
||||
}
|
||||
#endif
|
||||
|
||||
ClosePort(wm); /// Close RFID port
|
||||
ClosePort(ihead); /// Close RFID port
|
||||
|
||||
return error;
|
||||
}
|
||||
@@ -1207,14 +1217,14 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
/// <summary>
|
||||
/// Reset 2Hz correction factor in the memory to 0.
|
||||
/// </summary>
|
||||
/// <param name="wm">Water meter object</param>
|
||||
/// <param name="ihead">Water meter object</param>
|
||||
/// <param name="resultStr">String passed to caller</param>
|
||||
/// <returns>true on success</returns>
|
||||
static CommErr Reset2HzCorrection(WaterMeters.iPerl.WaterMeter wm, ref string resultStr)
|
||||
static CommErr Reset2HzCorrection(IperlHead ihead, WaterMeters.WaterMeter.WaterMeter wm, ref string resultStr)
|
||||
{
|
||||
if (wm.CommFailed) return CommErr.CommFailed;
|
||||
if (ihead.CommFailed) return CommErr.CommFailed;
|
||||
|
||||
if (OpenPort(wm) != 0) return CommErr.OpenPort; /// Open RFID port
|
||||
if (OpenPort(ihead) != 0) return CommErr.OpenPort; /// Open RFID port
|
||||
|
||||
CommErr error = CommErr.Write;
|
||||
|
||||
@@ -1223,7 +1233,7 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
///
|
||||
for (int j = 0; j < cfg.MaxCommRetries; j++)
|
||||
{
|
||||
if (0 == WriteRequestPort(wm, MessageID.MetrologyMemory, Hz2CorrFactorsAddr, wrData.Length, wrData, cfg.CommTimeout))
|
||||
if (0 == WriteRequestPort(ihead, MessageID.MetrologyMemory, Hz2CorrFactorsAddr, wrData.Length, wrData, cfg.CommTimeout))
|
||||
{
|
||||
error = CommErr.None;
|
||||
break;
|
||||
@@ -1257,11 +1267,11 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
if (error == CommErr.None)
|
||||
{
|
||||
resultStr = "2Hz correction reset to 0";
|
||||
wm.Hz2CorrectionFactor = 0;
|
||||
ihead.Hz2CorrectionFactor = 0;
|
||||
}
|
||||
#endif
|
||||
|
||||
ClosePort(wm); /// Close RFID port
|
||||
ClosePort(ihead); /// Close RFID port
|
||||
|
||||
return error;
|
||||
}
|
||||
@@ -1271,17 +1281,17 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
/// Write the calculated Q2 correction factors to the memory.
|
||||
/// Read them back to verify factors were written correctly.
|
||||
/// </summary>
|
||||
/// <param name="wm">Water meter object</param>
|
||||
/// <param name="ihead">Water meter object</param>
|
||||
/// <param name="resultStr">String passed to caller</param>
|
||||
/// <returns>true on success</returns>
|
||||
static CommErr WriteQ2Correction(WaterMeters.iPerl.WaterMeter wm, ref string resultStr, bool DEWA)
|
||||
static CommErr WriteQ2Correction(IperlHead ihead, WaterMeters.WaterMeter.WaterMeter wm, ref string resultStr, bool DEWA)
|
||||
{
|
||||
if (wm.CommFailed) return CommErr.CommFailed;
|
||||
if (wm.LastTestResult == null) return CommErr.CommFailed; /// This should never happen
|
||||
if (ihead.CommFailed) return CommErr.CommFailed;
|
||||
if (ihead.LastTestResult == null) return CommErr.CommFailed; /// This should never happen
|
||||
|
||||
wm.Q2ErrorWOCorrection = wm.LastTestResult.Error;
|
||||
wm.Q2CorrectionDone = false;
|
||||
wm.Q2CorrRFlow = 0;
|
||||
ihead.Q2ErrorWOCorrection = ihead.LastTestResult.Error;
|
||||
ihead.Q2CorrectionDone = false;
|
||||
ihead.Q2CorrRFlow = 0;
|
||||
|
||||
double q2Correction = 0;
|
||||
Byte q2CorrRFlow = 0;
|
||||
@@ -1292,13 +1302,13 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
///
|
||||
/// Standard process
|
||||
///
|
||||
if (Math.Abs(wm.LastTestResult.Error) <= 0.5)
|
||||
if (Math.Abs(ihead.LastTestResult.Error) <= 0.5)
|
||||
{
|
||||
resultStr = string.Format("Q2 correction = 0 (writing bypassed)");
|
||||
return CommErr.None;
|
||||
}
|
||||
|
||||
if (!wm.CalculateQ2CorrectionFactor(wm.LastTestResult, out q2Correction))
|
||||
if (!ihead.CalculateQ2CorrectionFactor(ihead.LastTestResult, out q2Correction))
|
||||
{
|
||||
return CommErr.None; /// Q2 error is too large, water meter failed anyhow
|
||||
}
|
||||
@@ -1311,18 +1321,18 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
///
|
||||
/// DEWA process
|
||||
///
|
||||
if (wm.LastTestResult.Error >= 0 && wm.LastTestResult.Error <= 1.0)
|
||||
if (ihead.LastTestResult.Error >= 0 && ihead.LastTestResult.Error <= 1.0)
|
||||
{
|
||||
resultStr = string.Format("Q2 correction = 0 (writing bypassed)");
|
||||
return CommErr.None;
|
||||
}
|
||||
|
||||
if (!wm.CalculateQ2CorrectionFactor(wm.LastTestResult, out q2Correction))
|
||||
if (!ihead.CalculateQ2CorrectionFactor(ihead.LastTestResult, out q2Correction))
|
||||
{
|
||||
return CommErr.None; /// Q2 error is too large, water meter failed anyhow
|
||||
}
|
||||
|
||||
if (wm.LastTestResult.Error < 0)
|
||||
if (ihead.LastTestResult.Error < 0)
|
||||
{
|
||||
q2CorrRFlow = (byte)((int)Math.Round(1.1 * q2Correction) & 0x000000FF);
|
||||
q2CorrLFlow = (byte)((int)Math.Round(1.1 * q2Correction) & 0x000000FF);
|
||||
@@ -1334,7 +1344,7 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
}
|
||||
}
|
||||
|
||||
if (OpenPort(wm) != 0) return CommErr.OpenPort; /// Open RFID port
|
||||
if (OpenPort(ihead) != 0) return CommErr.OpenPort; /// Open RFID port
|
||||
|
||||
CommErr error = CommErr.Write;
|
||||
|
||||
@@ -1342,7 +1352,7 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
///
|
||||
for (int j = 0; j < cfg.MaxCommRetries; j++)
|
||||
{
|
||||
if (0 == WriteRequestPort(wm, MessageID.MetrologyMemory, Q2CorrFactorsAddr, wrData.Length, wrData, cfg.CommTimeout))
|
||||
if (0 == WriteRequestPort(ihead, MessageID.MetrologyMemory, Q2CorrFactorsAddr, wrData.Length, wrData, cfg.CommTimeout))
|
||||
{
|
||||
error = CommErr.None;
|
||||
break;
|
||||
@@ -1366,9 +1376,21 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
{
|
||||
error = CommErr.None;
|
||||
resultStr = string.Format("Q2 factors: R-flow={0}, L-flow={1}", (SByte)q2CorrRFlow, (SByte)q2CorrLFlow);
|
||||
rfidDataLogger.Warn(wm.Name + ": " + resultStr);
|
||||
wm.Q2CorrectionDone = true;
|
||||
wm.Q2CorrectionFactor = q2CorrectionFactor;
|
||||
rfidDataLogger.Warn(ihead.Name + ": " + resultStr);
|
||||
ihead.Q2CorrectionDone = true;
|
||||
ihead.Q2Correction = q2Correction;
|
||||
ihead.Q2CorrRFlow = (int)(sbyte)q2CorrRFlow;
|
||||
ihead.Q2CorrLFlow = (int)(sbyte)q2CorrLFlow;
|
||||
#if IPERL
|
||||
if (wm != null)
|
||||
{
|
||||
wm.Q2ErrorWOCorrection = ihead.Q2ErrorWOCorrection;
|
||||
wm.Q2CorrectionDone = ihead.Q2CorrectionDone;
|
||||
wm.Q2Correction = ihead.Q2Correction;
|
||||
wm.Q2CorrRFlow = ihead.Q2CorrRFlow;
|
||||
wm.Q2CorrLFlow = ihead.Q2CorrLFlow;
|
||||
}
|
||||
#endif
|
||||
break;
|
||||
}
|
||||
}
|
||||
@@ -1377,15 +1399,25 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
if (error == CommErr.None)
|
||||
{
|
||||
resultStr = string.Format("Q2 correction: R-flow={0}, L-flow={1}", (SByte)q2CorrRFlow, (SByte)q2CorrLFlow);
|
||||
rfidDataLogger.Warn(wm.Name + ": " + resultStr);
|
||||
wm.Q2CorrectionDone = true;
|
||||
wm.Q2Correction = q2Correction;
|
||||
wm.Q2CorrRFlow = (int)(sbyte)q2CorrRFlow;
|
||||
wm.Q2CorrLFlow = (int)(sbyte)q2CorrLFlow;
|
||||
rfidDataLogger.Warn(ihead.Name + ": " + resultStr);
|
||||
ihead.Q2CorrectionDone = true;
|
||||
ihead.Q2Correction = q2Correction;
|
||||
ihead.Q2CorrRFlow = (int)(sbyte)q2CorrRFlow;
|
||||
ihead.Q2CorrLFlow = (int)(sbyte)q2CorrLFlow;
|
||||
#if IPERL
|
||||
if (wm != null)
|
||||
{
|
||||
wm.Q2ErrorWOCorrection = ihead.Q2ErrorWOCorrection;
|
||||
wm.Q2CorrectionDone = ihead.Q2CorrectionDone;
|
||||
wm.Q2Correction = ihead.Q2Correction;
|
||||
wm.Q2CorrRFlow = ihead.Q2CorrRFlow;
|
||||
wm.Q2CorrLFlow = ihead.Q2CorrLFlow;
|
||||
}
|
||||
#endif
|
||||
}
|
||||
#endif
|
||||
|
||||
ClosePort(wm); /// Close RFID port
|
||||
ClosePort(ihead); /// Close RFID port
|
||||
|
||||
return error;
|
||||
}
|
||||
@@ -1394,17 +1426,17 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
/// <summary>
|
||||
/// Write the calculated 2Hz correction factor to the memory.
|
||||
/// </summary>
|
||||
/// <param name="wm">Water meter object</param>
|
||||
/// <param name="ihead">Water meter object</param>
|
||||
/// <param name="resultStr">String passed to caller</param>
|
||||
/// <returns>true on success</returns>
|
||||
static CommErr Write2HzCorrection(WaterMeters.iPerl.WaterMeter wm, ref string resultStr)
|
||||
static CommErr Write2HzCorrection(IperlHead ihead, WaterMeters.WaterMeter.WaterMeter wm, ref string resultStr)
|
||||
{
|
||||
if (wm.CommFailed) return CommErr.CommFailed;
|
||||
if (ihead.CommFailed) return CommErr.CommFailed;
|
||||
|
||||
/// Calculate the correction
|
||||
wm.Hz2CorrectionDone = false;
|
||||
ihead.Hz2CorrectionDone = false;
|
||||
int hz2CorrectionFactor;
|
||||
bool wmOK = wm.Calculate2HzCorrectionFactor(wm.LastTestResult2, wm.LastTestResult, out wm.Diff2Hz8Hz, out hz2CorrectionFactor);
|
||||
bool wmOK = ihead.Calculate2HzCorrectionFactor(ihead.LastTestResult2, ihead.LastTestResult, out ihead.Diff2Hz8Hz, out hz2CorrectionFactor);
|
||||
|
||||
if (hz2CorrectionFactor == 0)
|
||||
{
|
||||
@@ -1412,7 +1444,7 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
return CommErr.None;
|
||||
}
|
||||
|
||||
if (OpenPort(wm) != 0) return CommErr.OpenPort; /// Open RFID port
|
||||
if (OpenPort(ihead) != 0) return CommErr.OpenPort; /// Open RFID port
|
||||
|
||||
CommErr error = CommErr.Write;
|
||||
|
||||
@@ -1421,9 +1453,18 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
///
|
||||
for (int j = 0; j < cfg.MaxCommRetries; j++)
|
||||
{
|
||||
if (0 == WriteRequestPort(wm, MessageID.MetrologyMemory, Hz2CorrFactorsAddr, wrData.Length, wrData, cfg.CommTimeout))
|
||||
if (0 == WriteRequestPort(ihead, MessageID.MetrologyMemory, Hz2CorrFactorsAddr, wrData.Length, wrData, cfg.CommTimeout))
|
||||
{
|
||||
error = CommErr.None;
|
||||
ihead.Hz2CorrectionFactor = hz2CorrectionFactor;
|
||||
ihead.Hz2CorrectionDone = true;
|
||||
#if IPERL
|
||||
if (wm != null)
|
||||
{
|
||||
wm.Hz2CorrectionDone = ihead.Hz2CorrectionDone;
|
||||
wm.Hz2CorrectionFactor = ihead.Hz2CorrectionFactor;
|
||||
}
|
||||
#endif
|
||||
break;
|
||||
}
|
||||
}
|
||||
@@ -1455,13 +1496,13 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
if (error == CommErr.None)
|
||||
{
|
||||
resultStr = string.Format("2Hz correction = {0}", (SByte)hz2CorrectionByte);
|
||||
rfidDataLogger.Warn(wm.Name + ": " + resultStr);
|
||||
wm.Hz2CorrectionDone = true;
|
||||
wm.Hz2CorrectionFactor = hz2CorrectionFactor;
|
||||
rfidDataLogger.Warn(ihead.Name + ": " + resultStr);
|
||||
ihead.Hz2CorrectionDone = true;
|
||||
ihead.Hz2CorrectionFactor = hz2CorrectionFactor;
|
||||
}
|
||||
#endif
|
||||
|
||||
ClosePort(wm); /// Close RFID port
|
||||
ClosePort(ihead); /// Close RFID port
|
||||
|
||||
return error;
|
||||
}
|
||||
@@ -1482,9 +1523,9 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
{
|
||||
if (data.WMNr >= 0) messages[data.WMNr].Text = data.CommMessage;
|
||||
|
||||
for (int i = 0; i < waterMeters.Count; i++)
|
||||
for (int i = 0; i < iperlHeads.Count; i++)
|
||||
{
|
||||
counters[i].BackColor = (waterMeters[i].FlushedDataDelta == 0) ? Color.Red : Color.Green;
|
||||
counters[i].BackColor = (iperlHeads[i].FlushedDataDelta == 0) ? Color.Red : Color.Green;
|
||||
}
|
||||
|
||||
lock (this)
|
||||
@@ -1567,21 +1608,19 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
tstRslt.EndTime = endTime;
|
||||
tstRslt.FlowSetTime = 0;
|
||||
tstRslt.TestTime += testTime; /// [s] total communication time of all tests
|
||||
|
||||
for (int i = 0; i < waterMeters.Count; i++)
|
||||
{
|
||||
Results.Entities.MeterTestRslt meterRslt =
|
||||
|
||||
for (int i = 0; i < iperlHeads.Count; i++)
|
||||
{
|
||||
Results.Entities.MeterTestRslt meterRslt =
|
||||
ProcessData.BatchRslts.GetMeterTestRslt(test.Name, waterMeterPositions[i], Config.Entities.CompoundMeterId.Single);
|
||||
|
||||
WaterMeters.iPerl.WaterMeter iPerl = waterMeters[i] as WaterMeters.iPerl.WaterMeter;
|
||||
|
||||
if (meterRslt != null && iPerl != null)
|
||||
{
|
||||
meterRslt.WaterMeter.SerialNr = iPerl.SerialNr;
|
||||
meterRslt.Passed = (!iPerl.CommFailed && !iPerl.Disabled);
|
||||
meterRslt.TestDone = true;
|
||||
}
|
||||
}
|
||||
if (meterRslt != null && iperlHeads[i] != null)
|
||||
{
|
||||
meterRslt.WaterMeter.SerialNr = iperlHeads[i].SerialNr;
|
||||
meterRslt.Passed = (!iperlHeads[i].CommFailed && !iperlHeads[i].Disabled);
|
||||
meterRslt.TestDone = true;
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
+7
-7
@@ -124,14 +124,14 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
|
||||
for (int i = 0; i < Config.Data.WMsCount; i++)
|
||||
{
|
||||
WaterMeters.iPerl.WaterMeter iPerl = ((sensPath.RegisterReaders != null) && (i < sensPath.RegisterReaders.Length))
|
||||
? (sensPath.RegisterReaders[i] as WaterMeters.iPerl.WaterMeter)
|
||||
: null;
|
||||
TestMethods.iPerlCommunication.iPerlHead.IperlHead iPerl = ((sensPath.RegisterReaders != null) && (i < sensPath.RegisterReaders.Length))
|
||||
? (sensPath.RegisterReaders[i] as TestMethods.iPerlCommunication.iPerlHead.IperlHead)
|
||||
: null;
|
||||
if (iPerl != null)
|
||||
{
|
||||
/// TODO: Reimplement
|
||||
//iPerl.LastTestResult = meterRslt; /// Save this water meter test result to iPerl WM
|
||||
iPerl.NominalTestFlow = 500.0 * (double)(test.Qfrom + test.Qto); /// Ave. + convert to liter/hour
|
||||
iPerl.NominalTestFlowLph = 500.0 * (double)(test.Qfrom + test.Qto); /// Ave. + convert to liter/hour
|
||||
}
|
||||
}
|
||||
|
||||
@@ -293,9 +293,9 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
||||
Results.Entities.MeterTestRslt meterRslt = ProcessData.BatchRslts.GetMeterTestRslt(testName, i, CompoundMeterId.Single);
|
||||
|
||||
/// Reference to iPerl water meter or null:
|
||||
WaterMeters.iPerl.WaterMeter iPerl = ((sensPath.RegisterReaders != null) && (i < sensPath.RegisterReaders.Length))
|
||||
? (sensPath.RegisterReaders[i] as WaterMeters.iPerl.WaterMeter)
|
||||
: null;
|
||||
TestMethods.iPerlCommunication.iPerlHead.IperlHead iPerl = ((sensPath.RegisterReaders != null) && (i < sensPath.RegisterReaders.Length))
|
||||
? (sensPath.RegisterReaders[i] as TestMethods.iPerlCommunication.iPerlHead.IperlHead)
|
||||
: null;
|
||||
|
||||
if (meterRslt != null && oriMeterRslt != null)
|
||||
{
|
||||
|
||||
+188
@@ -0,0 +1,188 @@
|
||||
///
|
||||
/// Copyright (c) 2015-2017 Sensus Metering Systems
|
||||
///
|
||||
using System;
|
||||
|
||||
namespace TBF.BenchControl.TestMethods.iPerlCommunication.iPerlHead
|
||||
{
|
||||
public class CalibrationStruct
|
||||
{
|
||||
public static readonly int Length = 35;
|
||||
|
||||
public Byte Version;
|
||||
public MeterType MeterType;
|
||||
public UInt16 Calibration;
|
||||
public VolumeUnits VolumeUnits;
|
||||
public FlowArrow FlowArrow;
|
||||
public UInt16 FWVersion;
|
||||
public UInt16[] TargetField;
|
||||
public UInt16 RecipMeanCurrent;
|
||||
public UInt16 ThresholdVolume;
|
||||
public UInt16 ThresholdTime;
|
||||
public UInt16 FlowActivationThr;
|
||||
public UInt16 VolumeArrowThr;
|
||||
public UInt32 CalibrationTime;
|
||||
public ulong SerialNumber;
|
||||
public MeterSealed MeterSealed;
|
||||
public byte CheckSum;
|
||||
|
||||
|
||||
public CalibrationStruct()
|
||||
{
|
||||
TargetField = new UInt16[3];
|
||||
}
|
||||
|
||||
public byte[] ToByteArray()
|
||||
{
|
||||
byte[] result = new byte[Length];
|
||||
|
||||
result[0] = Version;
|
||||
result[1] = (byte)MeterType;
|
||||
|
||||
result[2] = (byte)(Calibration & 0x00FF);
|
||||
result[3] = (byte)((Calibration >> 8) & 0x00FF);
|
||||
|
||||
result[4] = (byte)VolumeUnits;
|
||||
|
||||
result[5] = (byte)FlowArrow;
|
||||
|
||||
result[6] = (byte)(FWVersion & 0x00FF);
|
||||
result[7] = (byte)((FWVersion >> 8) & 0x00FF);
|
||||
|
||||
result[8] = (byte)( TargetField[0] & 0x00FF);
|
||||
result[9] = (byte)((TargetField[0] >> 8) & 0x00FF);
|
||||
result[10] = (byte)( TargetField[1] & 0x00FF);
|
||||
result[11] = (byte)((TargetField[1] >> 8) & 0x00FF);
|
||||
result[12] = (byte)( TargetField[2] & 0x00FF);
|
||||
result[13] = (byte)((TargetField[2] >> 8) & 0x00FF);
|
||||
|
||||
result[14] = (byte)(RecipMeanCurrent & 0x00FF);
|
||||
result[15] = (byte)((RecipMeanCurrent >> 8) & 0x00FF);
|
||||
|
||||
result[16] = (byte)(ThresholdVolume & 0x00FF);
|
||||
result[17] = (byte)((ThresholdVolume >> 8) & 0x00FF);
|
||||
|
||||
result[18] = (byte)(ThresholdTime & 0x00FF);
|
||||
result[19] = (byte)((ThresholdTime >> 8) & 0x00FF);
|
||||
|
||||
result[20] = (byte)(FlowActivationThr & 0x00FF);
|
||||
result[21] = (byte)((FlowActivationThr >> 8) & 0x00FF);
|
||||
|
||||
result[22] = (byte)(VolumeArrowThr & 0x00FF);
|
||||
result[23] = (byte)((VolumeArrowThr >> 8) & 0x00FF);
|
||||
|
||||
result[24] = (byte)(CalibrationTime & 0x000000FF);
|
||||
result[25] = (byte)((CalibrationTime >> 8) & 0x000000FF);
|
||||
result[26] = (byte)((CalibrationTime >> 16) & 0x000000FF);
|
||||
result[27] = (byte)((CalibrationTime >> 24) & 0x000000FF);
|
||||
|
||||
result[28] = (byte)(SerialNumber & 0x00000000000000FF);
|
||||
result[29] = (byte)((SerialNumber >> 8) & 0x00000000000000FF);
|
||||
result[30] = (byte)((SerialNumber >> 16) & 0x00000000000000FF);
|
||||
result[31] = (byte)((SerialNumber >> 24) & 0x00000000000000FF);
|
||||
result[32] = (byte)((SerialNumber >> 32) & 0x00000000000000FF);
|
||||
|
||||
result[33] = (byte)MeterSealed;
|
||||
result[34] = CheckSum;
|
||||
|
||||
return result;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Create a calibration structure from a complete byte array
|
||||
/// </summary>
|
||||
/// <param name="data">A complete byte array data</param>
|
||||
/// <returns>CalibrationStruct or null when byte array was not complete</returns>
|
||||
public static CalibrationStruct FromByteArray(byte[] data)
|
||||
{
|
||||
if (data.Length != Length) return null;
|
||||
|
||||
CalibrationStruct result = new CalibrationStruct();
|
||||
|
||||
result.Version = data[0];
|
||||
result.MeterType = (MeterType)data[1];
|
||||
result.Calibration = (UInt16)(data[2] + 256 * data[3]);
|
||||
result.VolumeUnits = (VolumeUnits)data[4];
|
||||
result.FlowArrow = (FlowArrow)data[5];
|
||||
result.FWVersion = (UInt16)(data[6] + 256 * data[7]);
|
||||
result.TargetField[0] = (UInt16)(data[8] + 256 * data[9]);
|
||||
result.TargetField[1] = (UInt16)(data[10] + 256 * data[11]);
|
||||
result.TargetField[2] = (UInt16)(data[12] + 256 * data[13]);
|
||||
result.RecipMeanCurrent = (UInt16)(data[14] + 256 * data[15]);
|
||||
result.ThresholdVolume = (UInt16)(data[16] + 256 * data[17]);
|
||||
result.ThresholdTime = (UInt16)(data[18] + 256 * data[19]);
|
||||
result.FlowActivationThr = (UInt16)(data[20] + 256 * data[21]);
|
||||
result.VolumeArrowThr = (UInt16)(data[22] + 256 * data[23]);
|
||||
result.CalibrationTime = (((UInt32)data[27] * 256 + data[26]) * 256 + data[25]) * 256 + data[24];
|
||||
result.SerialNumber = ((((UInt64)data[32] * 256 + data[31]) * 256 + data[30]) * 256 + data[29]) * 256 + data[28];
|
||||
result.MeterSealed = (MeterSealed)data[33];
|
||||
result.CheckSum = data[34];
|
||||
|
||||
return result;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Update the calibration structure from an incomplete byte array
|
||||
/// </summary>
|
||||
/// <param name="data">Byte array data</param>
|
||||
/// <param name="offset">Offset of byte array data in CalibrationStruct</param>
|
||||
/// <returns>true when successful, false when data are not appropriate</returns>
|
||||
public bool Update(byte[] data, int offset)
|
||||
{
|
||||
if (offset == 2 && data.Length == 2)
|
||||
{
|
||||
/// Data containing iPerl calibration factor
|
||||
Calibration = (UInt16)(data[2 - offset] + 256 * data[3 - offset]);
|
||||
return true;
|
||||
}
|
||||
else if (offset == 0 && data.Length == Length)
|
||||
{
|
||||
/// Data containing a complete CalibrationStruct
|
||||
Version = data[0];
|
||||
MeterType = (MeterType)data[1];
|
||||
Calibration = (UInt16)(data[2] + 256 * data[3]);
|
||||
VolumeUnits = (VolumeUnits)data[4];
|
||||
FlowArrow = (FlowArrow)data[5];
|
||||
FWVersion = (UInt16)(data[6] + 256 * data[7]);
|
||||
TargetField[0] = (UInt16)(data[8] + 256 * data[9]);
|
||||
TargetField[1] = (UInt16)(data[10] + 256 * data[11]);
|
||||
TargetField[2] = (UInt16)(data[12] + 256 * data[13]);
|
||||
RecipMeanCurrent = (UInt16)(data[14] + 256 * data[15]);
|
||||
ThresholdVolume = (UInt16)(data[16] + 256 * data[17]);
|
||||
ThresholdTime = (UInt16)(data[18] + 256 * data[19]);
|
||||
FlowActivationThr = (UInt16)(data[20] + 256 * data[21]);
|
||||
VolumeArrowThr = (UInt16)(data[22] + 256 * data[23]);
|
||||
CalibrationTime = (((UInt32)data[27] * 256 + data[26]) * 256 + data[25]) * 256 + data[24];
|
||||
SerialNumber = ((((UInt64)data[32] * 256 + data[31]) * 256 + data[30]) * 256 + data[29]) * 256 + data[28];
|
||||
MeterSealed = (MeterSealed)data[33];
|
||||
CheckSum = data[34];
|
||||
return true;
|
||||
}
|
||||
else
|
||||
return false;
|
||||
}
|
||||
|
||||
public override string ToString()
|
||||
{
|
||||
return string.Format("Calibration: V{0} Type={1} Cal={2} Units={3} FlowArrow.{4} FW={5} Hi={6} Norm={7} Low={8} RMC={9} ThrVol={10} ThrTime={11} FlActThr={12} VolArrThr={13} CalTm={14} SN={15} MeterSealed={16} Chksum={17}",
|
||||
Version,
|
||||
MeterType,
|
||||
Calibration,
|
||||
VolumeUnits,
|
||||
FlowArrow,
|
||||
FWVersion,
|
||||
TargetField[0],
|
||||
TargetField[1],
|
||||
TargetField[2],
|
||||
RecipMeanCurrent,
|
||||
ThresholdVolume,
|
||||
ThresholdTime,
|
||||
FlowActivationThr,
|
||||
VolumeArrowThr,
|
||||
CalibrationTime,
|
||||
SerialNumber,
|
||||
MeterSealed,
|
||||
CheckSum.ToString("X2"));
|
||||
}
|
||||
}
|
||||
}
|
||||
+225
@@ -0,0 +1,225 @@
|
||||
///
|
||||
/// Copyright (c) 2015-2017 Sensus Metering Systems
|
||||
///
|
||||
using System;
|
||||
|
||||
namespace TBF.BenchControl.TestMethods.iPerlCommunication.iPerlHead
|
||||
{
|
||||
public class ConfigStruct
|
||||
{
|
||||
public static readonly int Length = 32;
|
||||
|
||||
public Byte Version;
|
||||
public MeterState MeterState;
|
||||
public UInt32 TargetTimeVeryLowBatt; /// in seconds
|
||||
public UInt32 TargetTimeLowBatt; /// in seconds
|
||||
public UInt32 TestModeTime; /// Max. test mode time in seconds
|
||||
public UInt16 EmptyPipeThreshold;
|
||||
public byte[] PCBNumber; /// 5 bytes
|
||||
public byte TestModeConfig;
|
||||
public UInt32 RadioAddress;
|
||||
public UInt16 TempCalibration;
|
||||
public UInt16 AlarmMask; /// Default 0xA3F7
|
||||
public UInt16 ConfigCheckSum;
|
||||
|
||||
public ConfigStruct()
|
||||
{
|
||||
PCBNumber = new byte[5];
|
||||
}
|
||||
|
||||
public byte[] ToByteArray()
|
||||
{
|
||||
byte[] result = new byte[Length];
|
||||
|
||||
result[0] = Version;
|
||||
result[1] = (byte)MeterState;
|
||||
|
||||
result[2] = (byte)(TargetTimeVeryLowBatt & 0x000000FF);
|
||||
result[3] = (byte)((TargetTimeVeryLowBatt >> 8) & 0x000000FF);
|
||||
result[4] = (byte)((TargetTimeVeryLowBatt >> 16) & 0x000000FF);
|
||||
result[5] = (byte)((TargetTimeVeryLowBatt >> 24) & 0x000000FF);
|
||||
|
||||
result[6] = (byte)(TargetTimeLowBatt & 0x000000FF);
|
||||
result[7] = (byte)((TargetTimeLowBatt >> 8) & 0x000000FF);
|
||||
result[8] = (byte)((TargetTimeLowBatt >> 16) & 0x000000FF);
|
||||
result[9] = (byte)((TargetTimeLowBatt >> 24) & 0x000000FF);
|
||||
|
||||
result[10] = (byte)(TestModeTime & 0x000000FF);
|
||||
result[11] = (byte)((TestModeTime >> 8) & 0x000000FF);
|
||||
result[12] = (byte)((TestModeTime >> 16) & 0x000000FF);
|
||||
result[13] = (byte)((TestModeTime >> 24) & 0x000000FF);
|
||||
|
||||
result[14] = (byte)(EmptyPipeThreshold & 0x00FF);
|
||||
result[15] = (byte)((EmptyPipeThreshold >> 8) & 0x00FF);
|
||||
|
||||
result[16] = PCBNumber[0];
|
||||
result[17] = PCBNumber[1];
|
||||
result[18] = PCBNumber[2];
|
||||
result[19] = PCBNumber[3];
|
||||
result[20] = PCBNumber[4];
|
||||
|
||||
result[21] = TestModeConfig;
|
||||
|
||||
result[22] = (byte)(RadioAddress & 0x000000FF);
|
||||
result[23] = (byte)((RadioAddress >> 8) & 0x000000FF);
|
||||
result[24] = (byte)((RadioAddress >> 16) & 0x000000FF);
|
||||
result[25] = (byte)((RadioAddress >> 24) & 0x000000FF);
|
||||
|
||||
result[26] = (byte)(TempCalibration & 0x00FF);
|
||||
result[27] = (byte)((TempCalibration >> 8) & 0x00FF);
|
||||
|
||||
result[28] = (byte)(AlarmMask & 0x00FF);
|
||||
result[29] = (byte)((AlarmMask >> 8) & 0x00FF);
|
||||
|
||||
result[30] = (byte)(ConfigCheckSum & 0x00FF);
|
||||
result[31] = (byte)((ConfigCheckSum >> 8) & 0x00FF);
|
||||
|
||||
return result;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Create a configuration structure from a complete byte array
|
||||
/// </summary>
|
||||
/// <param name="data">A complete byte array data</param>
|
||||
/// <returns>ConfigStruct or null when byte array was not complete</returns>
|
||||
public static ConfigStruct FromByteArray(byte[] data)
|
||||
{
|
||||
if (data.Length != Length) return null;
|
||||
|
||||
ConfigStruct result = new ConfigStruct();
|
||||
|
||||
result.Version = data[0];
|
||||
result.MeterState = (MeterState)data[1];
|
||||
result.TargetTimeVeryLowBatt = (((UInt32)data[5] * 256 + data[4]) * 256 + data[3]) * 256 + data[2];
|
||||
result.TargetTimeLowBatt = (((UInt32)data[9] * 256 + data[8]) * 256 + data[7]) * 256 + data[6];
|
||||
result.TestModeTime = (((UInt32)data[13] * 256 + data[12]) * 256 + data[11]) * 256 + data[10];
|
||||
result.EmptyPipeThreshold = (UInt16)(data[15] * 256 + data[14]);
|
||||
result.PCBNumber[0] = data[16];
|
||||
result.PCBNumber[1] = data[17];
|
||||
result.PCBNumber[2] = data[18];
|
||||
result.PCBNumber[3] = data[19];
|
||||
result.PCBNumber[4] = data[20];
|
||||
result.TestModeConfig = data[21];
|
||||
result.RadioAddress = (((UInt32)data[25] * 256 + data[24]) * 256 + data[23]) * 256 + data[22];
|
||||
result.TempCalibration = (UInt16)(data[27] * 256 + data[26]);
|
||||
result.AlarmMask = (UInt16)(data[29] * 256 + data[28]);
|
||||
result.ConfigCheckSum = (UInt16)(data[31] * 256 + data[30]);
|
||||
|
||||
return result;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Update the configuration structure from an incomplete byte array
|
||||
/// </summary>
|
||||
/// <param name="offset">Offset of byte array data in ConfigStruct</param>
|
||||
/// <param name="data">Byte array data</param>
|
||||
/// <returns>true when successful, false when data are not appropriate</returns>
|
||||
public bool Update(int offset, byte[] data)
|
||||
{
|
||||
if (offset == 0 && data.Length == 2)
|
||||
{
|
||||
/// iPerl mode of function
|
||||
Version = data[0];
|
||||
MeterState = (MeterState)data[1];
|
||||
return true;
|
||||
}
|
||||
else if (offset == 0 && data.Length == 4)
|
||||
{
|
||||
/// iPerl mode of function and extra 2 bytes
|
||||
Version = data[0];
|
||||
MeterState = (MeterState)data[1];
|
||||
return true;
|
||||
}
|
||||
else if (offset == 21 && data.Length == 1)
|
||||
{
|
||||
/// TestModeConfig value
|
||||
TestModeConfig = data[21 - offset];
|
||||
return true;
|
||||
}
|
||||
else if (offset == 0 && data.Length == Length)
|
||||
{
|
||||
/// Complete ConfigStruct
|
||||
Version = data[0];
|
||||
MeterState = (MeterState)data[1];
|
||||
TargetTimeVeryLowBatt = (((UInt32)data[5] * 256 + data[4]) * 256 + data[3]) * 256 + data[2];
|
||||
TargetTimeLowBatt = (((UInt32)data[9] * 256 + data[8]) * 256 + data[7]) * 256 + data[6];
|
||||
TestModeTime = (((UInt32)data[13] * 256 + data[12]) * 256 + data[11]) * 256 + data[10];
|
||||
EmptyPipeThreshold = (UInt16)(data[15] * 256 + data[14]);
|
||||
PCBNumber[0] = data[16];
|
||||
PCBNumber[1] = data[17];
|
||||
PCBNumber[2] = data[18];
|
||||
PCBNumber[3] = data[19];
|
||||
PCBNumber[4] = data[20];
|
||||
TestModeConfig = data[21];
|
||||
RadioAddress = (((UInt32)data[25] * 256 + data[24]) * 256 + data[23]) * 256 + data[22];
|
||||
TempCalibration = (UInt16)(data[27] * 256 + data[26]);
|
||||
AlarmMask = (UInt16)(data[29] * 256 + data[28]);
|
||||
ConfigCheckSum = (UInt16)(data[31] * 256 + data[30]);
|
||||
return true;
|
||||
}
|
||||
else
|
||||
return false;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Converts PCBNumber to string
|
||||
/// </summary>
|
||||
/// <param name="pcbNumber"></param>
|
||||
/// <returns>PCB number string</returns>
|
||||
public static string PCBNumber2String(byte[] pcbNumber)
|
||||
{
|
||||
if (pcbNumber.Length != 5) return string.Empty;
|
||||
|
||||
Int64 number = 0;
|
||||
for (int i = 4; i >= 0; i--)
|
||||
{
|
||||
number = 256 * number + (Int64)pcbNumber[i];
|
||||
}
|
||||
|
||||
return number.ToString();
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Converts PCBNumber to string
|
||||
/// </summary>
|
||||
/// <returns>PCB number string</returns>
|
||||
public string PCBNumber2String()
|
||||
{
|
||||
return ConfigStruct.PCBNumber2String(PCBNumber);
|
||||
}
|
||||
|
||||
public override string ToString()
|
||||
{
|
||||
return string.Format("Config: V{0} State={1} VLoBattT={2}s LoBattT={3}s TestModeT={4}s EPThld={5} PCB#={6} TMCfg={7} RadioAddr={8} TempCalib={9} AlarmMask={10} CfgCheckSum={11}",
|
||||
Version,
|
||||
MeterState,
|
||||
TargetTimeVeryLowBatt,
|
||||
TargetTimeLowBatt,
|
||||
TestModeTime,
|
||||
EmptyPipeThreshold,
|
||||
PCBNumber2String(),
|
||||
TestModeConfig.ToString("X2"),
|
||||
RadioAddress,
|
||||
TempCalibration,
|
||||
AlarmMask.ToString("X4"),
|
||||
ConfigCheckSum.ToString("X4"));
|
||||
}
|
||||
|
||||
public string ToString(int sel)
|
||||
{
|
||||
return string.Format("{1} PCB#={6} TMCfg={7}",
|
||||
Version,
|
||||
MeterState,
|
||||
TargetTimeVeryLowBatt,
|
||||
TargetTimeLowBatt,
|
||||
TestModeTime,
|
||||
EmptyPipeThreshold,
|
||||
PCBNumber2String(),
|
||||
TestModeConfig.ToString("X2"),
|
||||
RadioAddress,
|
||||
TempCalibration,
|
||||
AlarmMask.ToString("X4"),
|
||||
ConfigCheckSum.ToString("X4"));
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,110 @@
|
||||
///
|
||||
/// Copyright (c) 2015-2017 Sensus Metering Systems
|
||||
///
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.Linq;
|
||||
using System.Text;
|
||||
|
||||
namespace TBF.BenchControl.TestMethods.iPerlCommunication.iPerlHead
|
||||
{
|
||||
public enum MessageID
|
||||
{
|
||||
Calibration = 0x00, /// Access to stCalibration
|
||||
Configuration = 0x01, /// Access to stConfig
|
||||
Status = 0x02, /// Access to stStaus, read only
|
||||
Power = 0x03, /// Access to stPower, containing power info from both processors
|
||||
LCD = 0x04, /// Access to stLCD
|
||||
EventData = 0x05, /// NOT USED
|
||||
IntervalData = 0x06, /// NOT USED
|
||||
Diagnostics = 0x07, /// Access tostMetroDiagArray, read onl
|
||||
MetrologyMemory = 0x08, /// Memory block access, read only
|
||||
Error_LongAck = 0x09, /// Error message
|
||||
Command = 0x0A, /// Command to execute, with no arguments
|
||||
Parameterizing = 0x0B, /// Parameterizing message is used in MCI-SPI interface only
|
||||
Error_ShortAck = 0x0C, /// Short acknowledge message is used in MCI-SPI interface only
|
||||
ChanelAlive = 0x0D, /// Channel alive message is used in MCI-SPI interface only
|
||||
RadioPassthrough = 0x0E, /// RFID <-> Metrology <-> Radio passthrough message
|
||||
ASICRegisterReadTest = 0x0F, /// ASIC Register read test
|
||||
IMIDebugMessagesAccess = 0x10, /// IMI debug messages read test
|
||||
ProductionChecksumsRead = 0x11, /// Production checksum read: Calibration (1 byte), Configuration (2 bytes), spare (4 bytes)
|
||||
HardwareParametersTest = 0x12, /// Hardware Parameters Testing: User configurable fixed field drive time (1 byte)
|
||||
/// <summary>
|
||||
/// Notes:
|
||||
/// 1. Short Ack message contains 1-byte error code and all the fields (Offset, Payload length, payload and password) will not be present.
|
||||
/// 2. Channel Alive message does not contain the fields (Offset, Payload length, payload and password).
|
||||
/// 3. Except the above two special messages, rest all the messages in the above table will follow the message format mentioned in sections 3.1 and 3.2.
|
||||
/// </summary>
|
||||
Count /// Number of MessageID-s
|
||||
}
|
||||
|
||||
public enum MeterType : byte
|
||||
{
|
||||
DN15 = 0,
|
||||
CoaxManifold = 1,
|
||||
DN20 = 2,
|
||||
DN25 = 3,
|
||||
DN26 = 4, /// DN25*
|
||||
DN32 = 5,
|
||||
DN40 = 6,
|
||||
AutoDetect,
|
||||
Count /// Number of meter types
|
||||
}
|
||||
|
||||
public enum VolumeUnits : byte
|
||||
{
|
||||
m3 = 0,
|
||||
UK_gallon = 1,
|
||||
US_gallon = 2,
|
||||
Count /// Number of volume units
|
||||
}
|
||||
|
||||
public enum FlowArrow : byte
|
||||
{
|
||||
No = 0,
|
||||
Right = 1,
|
||||
Left = 2,
|
||||
Count /// Number of flow arrows
|
||||
}
|
||||
|
||||
public enum MeterSealed : byte
|
||||
{
|
||||
InProduction = 0x00,
|
||||
OutOfProduction = 0xA5,
|
||||
Sealed = 0x5A,
|
||||
}
|
||||
|
||||
public enum MeterState : byte
|
||||
{
|
||||
None = 0,
|
||||
Idle = 1,
|
||||
Active = 2,
|
||||
Test = 3,
|
||||
EndOfLife = 4,
|
||||
Count /// Number of meter states
|
||||
}
|
||||
|
||||
public enum FlowState : byte
|
||||
{
|
||||
No = 0,
|
||||
Reverse = 1,
|
||||
Forward = 2,
|
||||
EmptyPipe = 3,
|
||||
Count /// Number of flow states
|
||||
}
|
||||
|
||||
public enum OptoTelegramFlags : byte
|
||||
{
|
||||
OK = 0,
|
||||
OK_TestStart,
|
||||
OK_TestEnd,
|
||||
InvalidTelegram, /// Wrong telegram format of checksum error
|
||||
SyncError,
|
||||
}
|
||||
|
||||
public enum OptoState
|
||||
{
|
||||
Read,
|
||||
Flush,
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,26 @@
|
||||
///
|
||||
/// Copyright (c) 2015-2017 Sensus Metering Systems
|
||||
///
|
||||
using System.Collections.Generic;
|
||||
using TBF.BenchControl.Generic;
|
||||
|
||||
namespace TBF.BenchControl.TestMethods.iPerlCommunication.iPerlHead
|
||||
{
|
||||
public class Factory : IComponentFactory
|
||||
{
|
||||
public string ClassName { get { return "RegisterReader for iPerl/iPerl Head"; } }
|
||||
|
||||
public void ResetStaticProperties() { IperlHead.ResetStaticProperties(); }
|
||||
|
||||
public IComponent DummyComponent() { return new IperlHead(); }
|
||||
|
||||
public IComponent GetComponent(IComponentCfg cfg, IList<IComponent> components) { return new IperlHead(cfg); }
|
||||
|
||||
public IComponentCfg DefaultConfig() { return new IperlHeadCfg(this); }
|
||||
|
||||
public IComponentCfg CmpntCfgFromCmpntEntity(Config.Entities.Component component)
|
||||
{
|
||||
return ComponentCfgBase.CreateFromDbEntity(typeof(IperlHeadCfg), component, this);
|
||||
}
|
||||
}
|
||||
}
|
||||
+845
@@ -0,0 +1,845 @@
|
||||
///
|
||||
/// Copyright (c) 2015-2017 Sensus Metering Systems
|
||||
///
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.IO;
|
||||
using System.IO.Ports;
|
||||
using System.Threading;
|
||||
using System.Windows.Forms;
|
||||
using log4net;
|
||||
using Config.Entities;
|
||||
using TBF.BenchControl;
|
||||
using TBF.BenchControl.Generic;
|
||||
using TBF.Resources;
|
||||
|
||||
namespace TBF.BenchControl.TestMethods.iPerlCommunication.iPerlHead
|
||||
{
|
||||
/// <summary>
|
||||
/// This component = instance of this class is a placeholder for a combined main watermeter
|
||||
/// </summary>
|
||||
public class IperlHead : ComponentBase, IDevice, GenericDevices.IRegisterReader, IOperation
|
||||
{
|
||||
private static readonly ILog log = LogManager.GetLogger(typeof(IperlHead));
|
||||
public override string ToString() { return string.Format("iPerl({0})", Cfg.ToString(1)); }
|
||||
|
||||
|
||||
readonly IperlHeadCfg iperlHeadCfg;
|
||||
|
||||
public int RfidComPortNr { get { return iperlHeadCfg.RfidComPortNr; } }
|
||||
public int MuxBoardNr { get { return iperlHeadCfg.MuxBoardNr; } }
|
||||
public int Group { get { return iperlHeadCfg.Group; } }
|
||||
|
||||
public double PulsesPerLtr { get { return 1000.0; } }
|
||||
public double LtrsPerPulse { get { return 1 / PulsesPerLtr; } }
|
||||
|
||||
#if ORACLE_DB
|
||||
public int WMType_ID { get { return iperlHeadCfg.ProcParams.WMType_ID; } } /// Required by Oracle DB
|
||||
public int WMType_Rev { get { return iperlHeadCfg.ProcParams.WMType_Rev; } } /// Required by Oracle DB
|
||||
#endif
|
||||
public ushort FactorLimitLo { get { return (ushort)iperlHeadCfg.ProcParams.FactorLimitLo; } }
|
||||
public ushort FactorLimitHi { get { return (ushort)iperlHeadCfg.ProcParams.FactorLimitHi; } }
|
||||
|
||||
/// Properties set by the Begin and the End form
|
||||
public string SerialNr
|
||||
{
|
||||
get
|
||||
{
|
||||
if (ConfigStruct != null) return configStruct.PCBNumber2String();
|
||||
else return string.Empty;
|
||||
}
|
||||
set { }
|
||||
}
|
||||
|
||||
public string EndState
|
||||
{
|
||||
get { return endState; }
|
||||
set { endState = value; }
|
||||
}
|
||||
string endState;
|
||||
|
||||
public string BeginState
|
||||
{
|
||||
get { return beginState; }
|
||||
set { beginState = value; }
|
||||
}
|
||||
string beginState;
|
||||
|
||||
public bool Disabled
|
||||
{
|
||||
get { return disabled; }
|
||||
set { disabled = value; }
|
||||
}
|
||||
bool disabled;
|
||||
|
||||
public bool CommFailed
|
||||
{
|
||||
get { return commFailed; }
|
||||
set { commFailed = value; }
|
||||
}
|
||||
bool commFailed;
|
||||
|
||||
|
||||
/// <summary>
|
||||
/// Passed to OptoTelegramRaw.UpdateFromString(...)
|
||||
/// </summary>
|
||||
Int64 volumeRawExtLast;
|
||||
Int64 timestampExtLast;
|
||||
|
||||
|
||||
public bool PositiveCounting;
|
||||
|
||||
/// <summary> ConfigStruct of the water meter obtained or updated by iPerlCommunication </summary>
|
||||
public ConfigStruct ConfigStruct
|
||||
{
|
||||
get { return configStruct; }
|
||||
set { configStruct = value; }
|
||||
}
|
||||
ConfigStruct configStruct;
|
||||
|
||||
/// <summary> CalibrationStruct of the water meter obtained or updated by iPerlCommunication </summary>
|
||||
public CalibrationStruct CalibrationStruct
|
||||
{
|
||||
get { return calibrationStruct; }
|
||||
set { calibrationStruct = value; }
|
||||
}
|
||||
CalibrationStruct calibrationStruct;
|
||||
|
||||
public ushort OriginalCalibFactor;
|
||||
public ushort CalibrationFactor { get { return (CalibrationStruct != null) ? CalibrationStruct.Calibration : (ushort)0; } }
|
||||
|
||||
public double Q2ErrorWOCorrection;
|
||||
public bool Q2CorrectionDone;
|
||||
public double Q2Correction;
|
||||
public int Q2CorrRFlow;
|
||||
public int Q2CorrLFlow;
|
||||
|
||||
public double Diff2Hz8Hz;
|
||||
public bool Hz2CorrectionDone;
|
||||
public int Hz2CorrectionFactor;
|
||||
|
||||
/// <summary> Result of the last test used to calculate Q2 correction factors, etc </summary>
|
||||
public Results.Entities.MeterTestRslt LastTestResult2;
|
||||
public Results.Entities.MeterTestRslt LastTestResult;
|
||||
public double NominalTestFlowLph; /// in liter per hour
|
||||
|
||||
|
||||
///
|
||||
/// Required for IRegisterReader interface
|
||||
///
|
||||
public int WMPulses { get { return wmPulses; } }
|
||||
public int WMRefPulses { get { return wmRefPulses; } }
|
||||
public double WMVolume { get { return wmVolume; } }
|
||||
public double BeginWMState { get { return beginWMState; } }
|
||||
public double EndWMState { get { return endWMState; } }
|
||||
public double WMTestTime { get { return wmTestTime; } }
|
||||
|
||||
|
||||
double beginWMState;
|
||||
double endWMState;
|
||||
double wmVolume;
|
||||
int wmPulses;
|
||||
int wmRefPulses;
|
||||
double wmTestTime;
|
||||
|
||||
|
||||
/// <summary>
|
||||
/// New calibration factor calculated from the original factor (argument)
|
||||
/// and results of the last test.
|
||||
/// </summary>
|
||||
/// <param name="originalCalibrationFactor">Original calibration factor</param>
|
||||
/// <returns>New calibration factor or 0 (= Out of range)</returns>
|
||||
public UInt16 CalculateNewCalibFactor(UInt16 originalCalibrationFactor, UInt16 FactorLimitLo, UInt16 FactorLimitHi)
|
||||
{
|
||||
OriginalCalibFactor = originalCalibrationFactor;
|
||||
|
||||
double volumeMeter = Math.Abs(VolumeLtrEnd - VolumeLtrStart);
|
||||
|
||||
if (volumeMeter > 1E-2)
|
||||
{
|
||||
PositiveCounting = VolumeLtrEnd > VolumeLtrStart;
|
||||
|
||||
UInt16 newFactor = (UInt16)((double)originalCalibrationFactor * VolumeLtrRef / volumeMeter + 0.5);
|
||||
log.InfoFormat("Calibration factor: orig={0} new={1} V_1={2} V_2={3} Vdiff={4} Vref={5}",
|
||||
originalCalibrationFactor, newFactor,
|
||||
VolumeLtrStart.ToString("F3"), VolumeLtrEnd.ToString("F3"), volumeMeter.ToString("F3"),
|
||||
VolumeLtrRef.ToString("F3"));
|
||||
|
||||
if (newFactor < FactorLimitLo || newFactor > FactorLimitHi) return 0;
|
||||
|
||||
return newFactor;
|
||||
}
|
||||
else
|
||||
{
|
||||
log.ErrorFormat("Calibration factor: orig={0} new={0} (unchanged!) Vdiff={1}",
|
||||
originalCalibrationFactor, volumeMeter.ToString("F3"));
|
||||
return originalCalibrationFactor; /// Too small volume in the denominator -> no correction at all
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
/// <summary>
|
||||
/// Q2 correction factor calculated from the last test (Q2).
|
||||
/// This factors should be used only for R800 meters.
|
||||
/// </summary>
|
||||
/// <param name="q2TestResult">Test result from which to calculate the factor</param>
|
||||
/// <param name="q2CorrectionFactor">The calculated Q2 correction factor</param>
|
||||
/// <returns>true = OK, false = failed</returns>
|
||||
public bool CalculateQ2CorrectionFactor(Results.Entities.MeterTestRslt q2TestResult, out double q2CorrectionFactor)
|
||||
{
|
||||
q2CorrectionFactor = 0;
|
||||
|
||||
if (q2TestResult == null) return false; /// Q2 test result is missing ==> water meter failed
|
||||
|
||||
double errLimitLo = q2TestResult.ErrLimLo() + q2TestResult.Uncertainty();
|
||||
double errLimitHi = q2TestResult.ErrLimHi() - q2TestResult.Uncertainty();
|
||||
|
||||
if ((q2TestResult.Error < errLimitLo) || (q2TestResult.Error > errLimitHi))
|
||||
{
|
||||
return false; /// Q2 error too large ==> water meter failed
|
||||
}
|
||||
|
||||
double A = 16.0 / ScalingFactor(); /// Raw units per ml: DN15=16, DN20=8, DN25=4, DN32=2, DN40=1
|
||||
const double B = 8.0; /// Raw units per minute, 8
|
||||
const double C = B * 60.0; /// Raw units per hour, 480
|
||||
double D = C / A; /// ml correction per hour
|
||||
double F = D / (NominalTestFlowLph * 10.0); /// Error corrected with 8 Raw Units per minute [%]
|
||||
double G = F / B; /// Error corrected with 1 Raw Unit per minute [%]
|
||||
|
||||
q2CorrectionFactor = (-1) * (q2TestResult.Error / G) * (q2TestResult.VolumeRef / q2TestResult.VolumeMeter);
|
||||
|
||||
log.WarnFormat("Q2 correction: Pos={0}, PCB#={1}, corrFactor={2}, error={3}% [Lo={4}%, Hi={5}%]",
|
||||
Name,
|
||||
SerialNr,
|
||||
q2CorrectionFactor.ToString("F1"),
|
||||
q2TestResult.Error.ToString("F2"),
|
||||
errLimitLo.ToString("F1"),
|
||||
errLimitHi.ToString("F1"));
|
||||
|
||||
return true;
|
||||
}
|
||||
|
||||
|
||||
/// <summary>
|
||||
/// 2 Hz correction factor calculated from two Q3 tests - done at 2Hz and at 8Hz.
|
||||
/// This factors should be used only for DN32 and DN40 meters.
|
||||
/// </summary>
|
||||
/// <param name="resultAt2Hz">Test result @2Hz from which to calculate the factor</param>
|
||||
/// <param name="resultAt8Hz">Test result @8Hz from which to calculate the factor</param>
|
||||
/// <param name="hz2CorrectionFactor">The calculated Q2 correction factor</param>
|
||||
/// <returns>true = OK, false = failed</returns>
|
||||
public bool Calculate2HzCorrectionFactor(Results.Entities.MeterTestRslt resultAt2Hz,
|
||||
Results.Entities.MeterTestRslt resultAt8Hz,
|
||||
out double diff2Hz8Hz, out int hz2CorrectionFactor)
|
||||
{
|
||||
hz2CorrectionFactor = 0;
|
||||
diff2Hz8Hz = 0;
|
||||
|
||||
if ((resultAt2Hz == null) || (resultAt8Hz == null))
|
||||
{
|
||||
return false; /// Test result @2Hz and/or @8Hz is missing ==> water meter failed
|
||||
}
|
||||
|
||||
diff2Hz8Hz = resultAt2Hz.Error - resultAt8Hz.Error;
|
||||
|
||||
if (Math.Abs(diff2Hz8Hz) > 2.5) return false; /// Difference of errors > 2.5 % ==> water meter failed
|
||||
|
||||
hz2CorrectionFactor = -1 * (int)Math.Round(10 * diff2Hz8Hz);
|
||||
|
||||
log.WarnFormat("2Hz correction: Pos={0}, PCB#={1}, corrFactor={2}, erro@2Hz={3}%, erro@8Hz={4}%",
|
||||
Name,
|
||||
SerialNr,
|
||||
hz2CorrectionFactor,
|
||||
resultAt2Hz.Error.ToString("F2"),
|
||||
resultAt8Hz.Error.ToString("F2"));
|
||||
|
||||
return true;
|
||||
}
|
||||
|
||||
|
||||
/// <summary> Name set by the test, to be used as a part of the opto-data log file name </summary>
|
||||
public string TestName;
|
||||
|
||||
/// <summary> Name set by the test, to be used as a part of the opto-data log file name </summary>
|
||||
public string BenchName;
|
||||
|
||||
///
|
||||
/// Volume of water from the opto telegram
|
||||
///
|
||||
private Int64 lastVolumeRaw; /// Last read raw volume
|
||||
private double volumeLtr; ///
|
||||
private double volumeLtr0;
|
||||
|
||||
public double VolumeLtrStart; /// Test start volume for metrology
|
||||
public double VolumeLtrEnd; /// Test end volume for metrology
|
||||
public double VolumeLtrRef; /// Reference volume or metrology
|
||||
double volumeLtrEnd1; /// auxiliary buffer1 to keep the end volume before test stops
|
||||
double volumeLtrEnd2; /// auxiliary buffer2 to keep the end volume before test stops
|
||||
double volumeLtrEnd3; /// auxiliary buffer3 to keep the end volume before test stops
|
||||
|
||||
///
|
||||
/// Timestamp from the opto telegram
|
||||
///
|
||||
bool lastTimestampValid;
|
||||
private Int64 lastTimestamp;
|
||||
private double timestampSec;
|
||||
private double timestampSec0;
|
||||
|
||||
public bool NoSamples { get { return (timestampSecEnd - timestampSecStart) < float.Epsilon; } }
|
||||
public double TimestampSecStart { get { return timestampSecStart; } }
|
||||
public double TimestampSecEnd { get { return timestampSecEnd; } }
|
||||
double timestampSecStart;
|
||||
double timestampSecEnd;
|
||||
double timestampSecEnd1;
|
||||
double timestampSecEnd2;
|
||||
double timestampSecEnd3;
|
||||
|
||||
private int telegramIx;
|
||||
public int TestStartTelegramIx;
|
||||
public int TestEndTelegramIx;
|
||||
|
||||
|
||||
OptoTelegramRaw[] optoData;
|
||||
const int MaxOptoDataCount = 40000;
|
||||
int optoDataCount;
|
||||
string optoDataLogFileName;
|
||||
|
||||
|
||||
OptoTelegramRaw toBeFlushed;
|
||||
int flushedDataCount;
|
||||
public int FlushedDataCount
|
||||
{
|
||||
get { return flushedDataCount; }
|
||||
set { flushedDataCount = lastFlushedDataCount = lastFlushedDataCount_1 = value; }
|
||||
}
|
||||
|
||||
int lastFlushedDataCount_1;
|
||||
int lastFlushedDataCount;
|
||||
public int FlushedDataDelta
|
||||
{
|
||||
get
|
||||
{
|
||||
int retval = Math.Max(flushedDataCount - lastFlushedDataCount, lastFlushedDataCount - lastFlushedDataCount_1);
|
||||
lastFlushedDataCount_1 = lastFlushedDataCount;
|
||||
lastFlushedDataCount = flushedDataCount;
|
||||
return retval;
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
|
||||
///
|
||||
/// Opto serial port and worker thread related private variables
|
||||
///
|
||||
private SerialPort optoSerialPort;
|
||||
|
||||
|
||||
public IperlHead()
|
||||
{
|
||||
ClearData();
|
||||
}
|
||||
|
||||
public IperlHead(Generic.IComponentCfg cfg)
|
||||
: base(cfg)
|
||||
{
|
||||
ClearData();
|
||||
|
||||
iperlHeadCfg = cfg as IperlHeadCfg;
|
||||
|
||||
log.Debug(this.ToString());
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Clear data related to a specific water meter
|
||||
/// </summary>
|
||||
public void ClearData()
|
||||
{
|
||||
disabled = false;
|
||||
commFailed = false;
|
||||
endState = string.Empty;
|
||||
beginState = string.Empty;
|
||||
|
||||
configStruct = null;
|
||||
calibrationStruct = null;
|
||||
|
||||
LastTestResult = null;
|
||||
NominalTestFlowLph = 0;
|
||||
|
||||
OriginalCalibFactor = 0;
|
||||
Q2ErrorWOCorrection = 0;
|
||||
Q2CorrectionDone = false;
|
||||
Q2CorrRFlow = 0;
|
||||
|
||||
optoDataCount = 0;
|
||||
}
|
||||
|
||||
public void Initialize()
|
||||
{
|
||||
ClearData();
|
||||
|
||||
if (DebugLevel == DebugMode.Normal)
|
||||
{
|
||||
optoSerialPortParsingEnabled = false;
|
||||
|
||||
/// Allocate memory for opto-data from iPerl
|
||||
optoData = new OptoTelegramRaw[MaxOptoDataCount];
|
||||
for (int i = 0; i < MaxOptoDataCount; i++) optoData[i] = new OptoTelegramRaw();
|
||||
|
||||
toBeFlushed = new OptoTelegramRaw();
|
||||
flushedDataCount = 0;
|
||||
|
||||
synchronized = false;
|
||||
synchronized2 = false;
|
||||
partOfTelegram = string.Empty;
|
||||
|
||||
/// Prepare serial port
|
||||
optoSerialPort = new SerialPort(string.Format("COM{0}", iperlHeadCfg.OptoComPortNr),
|
||||
9600, Parity.None, 8, StopBits.One);
|
||||
optoSerialPort.Handshake = Handshake.None;
|
||||
|
||||
optoSerialPort.Open();
|
||||
}
|
||||
}
|
||||
|
||||
public void RunDeviceBefore()
|
||||
{
|
||||
if (DebugLevel == DebugMode.Normal)
|
||||
{
|
||||
try
|
||||
{
|
||||
if (optoSerialPortParsingEnabled)
|
||||
ReadOptoData(OptoState.Read);
|
||||
else
|
||||
ReadOptoData(OptoState.Flush);
|
||||
}
|
||||
catch (Exception e)
|
||||
{
|
||||
DebugLevel = DebugMode.FailureDuringOperation;
|
||||
|
||||
log.FatalFormat("Opto-data serial port failure : {0}", e.Message);
|
||||
if (e.InnerException != null)
|
||||
{
|
||||
log.FatalFormat("InnerMessage : {0}", e.InnerException.Message);
|
||||
}
|
||||
}
|
||||
}
|
||||
else if (DebugLevel == DebugMode.FailureDuringOperation)
|
||||
{
|
||||
}
|
||||
}
|
||||
|
||||
public void RunDeviceAfter()
|
||||
{
|
||||
}
|
||||
|
||||
public void StopDevice()
|
||||
{
|
||||
try
|
||||
{
|
||||
if (DebugLevel == DebugMode.Normal && optoSerialPort != null)
|
||||
{
|
||||
optoSerialPort.Close();
|
||||
optoSerialPort = null;
|
||||
}
|
||||
}
|
||||
catch
|
||||
{
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Events: Event.ReadRegisterDone, Event.Error
|
||||
/// </summary>
|
||||
/// <returns>ReadWaterMeter instance reference casted to IOperaton</returns>
|
||||
public IOperation ReadRegisterOp()
|
||||
{
|
||||
return this;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Clear data/counters related to a specific tests
|
||||
/// </summary>
|
||||
public void Clear()
|
||||
{
|
||||
sampleNr = 0;
|
||||
|
||||
volumeLtr = 0;
|
||||
volumeLtr0 = 0;
|
||||
timestampSec = 0;
|
||||
timestampSec0 = 0;
|
||||
|
||||
ReadPulses();
|
||||
}
|
||||
|
||||
public void TestCompleted()
|
||||
{
|
||||
/// TODO: Implement
|
||||
}
|
||||
|
||||
|
||||
int sampleNr; /// This is to determine when the test start sample should be taken
|
||||
|
||||
/// <summary>Start this operation</summary>
|
||||
public void Start()
|
||||
{
|
||||
Clear();
|
||||
|
||||
/// Reset opto data
|
||||
optoDataCount = 0;
|
||||
TestStartTelegramIx = 0;
|
||||
TestEndTelegramIx = 0;
|
||||
|
||||
/// File name is: PCB_AA_BB_HH_MI_SS..txt
|
||||
string wmPosition = Name.Substring(5);
|
||||
if (wmPosition.Length == 1) wmPosition = "0" + wmPosition;
|
||||
|
||||
string flowNr;
|
||||
if (TestName != null && TestName.ToLower().Contains("q1")) flowNr = "01";
|
||||
else if (TestName != null && TestName.ToLower().Contains("q2")) flowNr = "02";
|
||||
else if (TestName != null && TestName.ToLower().Contains("q3")) flowNr = "03";
|
||||
else if (TestName != null && TestName.ToLower().Contains("adj")) flowNr = "0-1";
|
||||
else flowNr = "99";
|
||||
|
||||
optoDataLogFileName = string.Format("{0}_{1}_{2}_{3}.txt",
|
||||
(ConfigStruct != null) ? ConfigStruct.PCBNumber2String() : "UnknownPcbNr",
|
||||
wmPosition,
|
||||
flowNr,
|
||||
StateMachine.CycleStartTimeStamp.ToString("HH_mm_ss"));
|
||||
|
||||
StartParsingOptoSerialPort();
|
||||
}
|
||||
|
||||
/// <summary>Run this operation</summary>
|
||||
/// <returns>eventDone</returns>
|
||||
public Event Run()
|
||||
{
|
||||
sampleNr++;
|
||||
ReadPulses();
|
||||
if (sampleNr == 4)
|
||||
{
|
||||
/// Take the test start sample
|
||||
VolumeLtrStart = volumeLtr;
|
||||
timestampSecStart = timestampSec;
|
||||
TestStartTelegramIx = telegramIx;
|
||||
}
|
||||
|
||||
/// Shift data in pipelines
|
||||
VolumeLtrEnd = volumeLtrEnd3;
|
||||
volumeLtrEnd3 = volumeLtrEnd2;
|
||||
volumeLtrEnd2 = volumeLtrEnd1;
|
||||
volumeLtrEnd1 = volumeLtr;
|
||||
|
||||
timestampSecEnd = timestampSecEnd3;
|
||||
timestampSecEnd3 = timestampSecEnd2;
|
||||
timestampSecEnd2 = timestampSecEnd1;
|
||||
timestampSecEnd1 = timestampSec;
|
||||
|
||||
TestEndTelegramIx = telegramIx - 3;
|
||||
|
||||
return Event.ReadRegisterDone;
|
||||
}
|
||||
|
||||
/// <summary>Stop this operation</summary>
|
||||
public void Stop()
|
||||
{
|
||||
if (TestStartTelegramIx > 0 && TestStartTelegramIx < optoData.Length && optoData[TestStartTelegramIx].Flags == OptoTelegramFlags.OK)
|
||||
{
|
||||
optoData[TestStartTelegramIx].Flags = OptoTelegramFlags.OK_TestStart;
|
||||
OptoTelegramRaw.TestStartTimestampDec = optoData[TestStartTelegramIx].TimestampDec();
|
||||
}
|
||||
|
||||
if (TestEndTelegramIx > 0 && TestEndTelegramIx < optoData.Length && optoData[TestEndTelegramIx].Flags == OptoTelegramFlags.OK)
|
||||
{
|
||||
optoData[TestEndTelegramIx].Flags = OptoTelegramFlags.OK_TestEnd;
|
||||
}
|
||||
|
||||
StopParsingOptoSerialPort();
|
||||
OptoTelegramRaw.FIRFilterFlow(optoData, optoDataCount);
|
||||
SaveOptoData();
|
||||
}
|
||||
|
||||
|
||||
void SaveOptoData()
|
||||
{
|
||||
string directory = string.Format("C:\\TBF\\ProcessData\\{0}\\{1}\\{2}\\",
|
||||
StateMachine.CycleStartTimeStamp.ToString("yy"),
|
||||
StateMachine.CycleStartTimeStamp.ToString("MM"),
|
||||
StateMachine.CycleStartTimeStamp.ToString("dd"));
|
||||
try
|
||||
{
|
||||
Directory.CreateDirectory(directory);
|
||||
|
||||
double scalFact = ScalingFactor();
|
||||
|
||||
using (TextWriter optoLogFile = new StreamWriter(directory + optoDataLogFileName))
|
||||
{
|
||||
optoLogFile.WriteLine(optoData[0].ToString(scalFact, null));
|
||||
for (int i = 1; i < optoDataCount; i++) optoLogFile.WriteLine(optoData[i].ToString(scalFact, optoData[i - 1]));
|
||||
optoLogFile.Close();
|
||||
}
|
||||
}
|
||||
catch (Exception exc)
|
||||
{
|
||||
MessageBox.Show(Strings.Error_writing_into_file_ + Environment.NewLine +
|
||||
string.Format("{0}\\{1}\r\n{2}", directory, optoDataLogFileName, exc.Message),
|
||||
Strings.Error,
|
||||
MessageBoxButtons.OK,
|
||||
MessageBoxIcon.Exclamation);
|
||||
}
|
||||
}
|
||||
|
||||
void ReadPulses()
|
||||
{
|
||||
beginWMState = volumeLtr0;
|
||||
endWMState = volumeLtr;
|
||||
wmVolume = Math.Abs(endWMState - beginWMState);
|
||||
wmPulses = (int)(wmVolume * (double)PulsesPerLtr + 0.5);
|
||||
wmRefPulses = StateMachine.ControlBoard.EtPulses(0);
|
||||
wmTestTime = timestampSec - timestampSec0;
|
||||
}
|
||||
|
||||
|
||||
bool optoSerialPortParsingEnabled;
|
||||
|
||||
/// <summary> Flush internal buffers and start parsing the opto serial port data </summary>
|
||||
void StartParsingOptoSerialPort()
|
||||
{
|
||||
optoSerialPortParsingEnabled = true;
|
||||
}
|
||||
|
||||
/// <summary> Stop parsig the opto serial port data </summary>
|
||||
void StopParsingOptoSerialPort()
|
||||
{
|
||||
optoSerialPortParsingEnabled = false;
|
||||
}
|
||||
|
||||
///
|
||||
/// Variables storing the context of serial port data parsing (ReadOptoSerialPort(...))
|
||||
///
|
||||
bool synchronized;
|
||||
bool synchronized2;
|
||||
string partOfTelegram;
|
||||
|
||||
/// <summary>
|
||||
/// 9600 Bd, 8 data bits, 1 stop bit, no parity
|
||||
///
|
||||
/// Telegram description:
|
||||
///
|
||||
/// AAAAAA[tab]BBBB[tab]CCCC[tab]DDDDDD[tab]EEEE[tab]FFFFFFFF[tab]GG[cr][lf] (42 bytes)
|
||||
///
|
||||
/// Example:
|
||||
/// FFFFFE 51EA 0000 65324E 0087 F6319DFF 86
|
||||
/// FFDD3A 51F9 0000 65324E 0088 F631A60B 45
|
||||
/// ...
|
||||
/// </summary>
|
||||
/// <param name="optoState">OptoState.Read or OptoState.Flush</param>
|
||||
void ReadOptoData(OptoState optoState)
|
||||
{
|
||||
int nrBytes = optoSerialPort.BytesToRead;
|
||||
if (nrBytes > 0)
|
||||
{
|
||||
char[] buffer = new char[nrBytes];
|
||||
optoSerialPort.Read(buffer, 0, nrBytes);
|
||||
string received = new string(buffer);
|
||||
|
||||
string allRcvd = partOfTelegram + received;
|
||||
|
||||
while (true)
|
||||
{
|
||||
int pos = allRcvd.IndexOf("\r\n");
|
||||
|
||||
if (pos < 0)
|
||||
{
|
||||
/// No CR+LF found, wait for more characters in the next invocation
|
||||
partOfTelegram = allRcvd;
|
||||
return;
|
||||
}
|
||||
else
|
||||
{
|
||||
// CR+LF found
|
||||
if (optoState == OptoState.Read)
|
||||
{
|
||||
if (pos < OptoTelegramRaw.Length - 2)
|
||||
{
|
||||
/// CR+LF found too early, truncate the beginning incl CR+LF and keep scanning in this loop
|
||||
allRcvd = allRcvd.Substring(pos + 2);
|
||||
if (synchronized)
|
||||
{
|
||||
optoData[optoDataCount].Counter = optoDataCount;
|
||||
optoData[optoDataCount++].SetFlags(OptoTelegramFlags.SyncError);
|
||||
}
|
||||
synchronized = true;
|
||||
}
|
||||
// CR+LF found and (pos >= OptoTelegramRaw.Length - 2)
|
||||
else if (optoData[optoDataCount].UpdateFromString(allRcvd.Substring(pos - OptoTelegramRaw.Length + 2), optoDataCount, ref volumeRawExtLast, ref timestampExtLast))
|
||||
{
|
||||
OptoTelegramRreceived(optoDataCount++, synchronized2);
|
||||
synchronized2 = synchronized;
|
||||
allRcvd = allRcvd.Substring(pos + 2);
|
||||
}
|
||||
else
|
||||
{
|
||||
optoData[optoDataCount].Counter = optoDataCount;
|
||||
optoDataCount++;
|
||||
allRcvd = allRcvd.Substring(pos + 2);
|
||||
}
|
||||
}
|
||||
else /// optoState == OptoState.Flush
|
||||
{
|
||||
if (pos < OptoTelegramRaw.Length - 2)
|
||||
{
|
||||
/// CR+LF found too early, truncate the beginning incl CR+LF and keep scanning in this loop
|
||||
allRcvd = allRcvd.Substring(pos + 2);
|
||||
synchronized = true;
|
||||
}
|
||||
// CR+LF found and (pos >= OptoTelegram.Length - 2)
|
||||
else if (toBeFlushed.UpdateFromStringDummy(allRcvd.Substring(pos - OptoTelegramRaw.Length + 2)))
|
||||
{
|
||||
flushedDataCount++;
|
||||
synchronized2 = synchronized;
|
||||
allRcvd = allRcvd.Substring(pos + 2);
|
||||
}
|
||||
else
|
||||
{
|
||||
allRcvd = allRcvd.Substring(pos + 2);
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
//OnOptoReceived(this, new OptoReceivedEventArgs(s));
|
||||
}
|
||||
else
|
||||
{
|
||||
//OnOptoReceived(this, new OptoReceivedEventArgs("."));
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
void OptoTelegramRreceived(int currentIx, bool async)
|
||||
{
|
||||
OptoTelegramRaw optoTelegram = optoData[currentIx];
|
||||
telegramIx = currentIx;
|
||||
|
||||
lastVolumeRaw = volumeRawExtLast;
|
||||
lastTimestamp = timestampExtLast;
|
||||
|
||||
if (volumeLtr == 0 && volumeLtr0 == 0)
|
||||
{
|
||||
volumeLtr = (double)lastVolumeRaw * ScalingFactor() / 16000.0;
|
||||
volumeLtr0 = volumeLtr;
|
||||
}
|
||||
else
|
||||
{
|
||||
volumeLtr = (double)lastVolumeRaw * ScalingFactor() / 16000.0;
|
||||
}
|
||||
|
||||
if (timestampSec == 0 && timestampSec0 == 0)
|
||||
{
|
||||
timestampSec = (double)lastTimestamp / 8192.0;
|
||||
timestampSec0 = timestampSec;
|
||||
}
|
||||
else
|
||||
{
|
||||
timestampSec = (double)lastTimestamp / 8192.0;
|
||||
}
|
||||
|
||||
//optoDataLogger.InfoFormat("{0} {1} {2} ltr {3} {4}", optoTelegram, lastTimestamp, lastVolumeRaw.ToString("X8"), timestampSec.ToString("F1"), volumeLtr.ToString("F3"));
|
||||
}
|
||||
|
||||
|
||||
/// <summary>
|
||||
/// Called from the state machine when a test is selected and UI needs to be updated.
|
||||
/// </summary>
|
||||
public void OnOptoReceived(object sender, OptoReceivedEventArgs args)
|
||||
{
|
||||
if (OptoReceivedHandler == null) return;
|
||||
try { OptoReceivedHandler(sender, args); }
|
||||
catch (Exception) { }
|
||||
}
|
||||
|
||||
public event EventHandler<OptoReceivedEventArgs> OptoReceivedHandler;
|
||||
|
||||
|
||||
/// <summary>
|
||||
/// Compares CalibrationStruct.MeterType with iPerlCfg.MeterType.
|
||||
/// iPerlCfg.MeterType == MeterType.AutoDetect disables type checking
|
||||
/// CalibrationStruct == null disables type checking ...
|
||||
/// ... so that failed RFID communication does not cause type verification failure)
|
||||
/// </summary>
|
||||
/// <returns>true when type is OK</returns>
|
||||
public bool VerifyIPerlType()
|
||||
{
|
||||
if (iperlHeadCfg.MeterType == MeterType.AutoDetect || CalibrationStruct == null)
|
||||
{
|
||||
return true;
|
||||
}
|
||||
|
||||
return iperlHeadCfg.MeterType == CalibrationStruct.MeterType;
|
||||
}
|
||||
|
||||
public static double UnitVolume(VolumeUnits units)
|
||||
{
|
||||
switch (units)
|
||||
{
|
||||
default:
|
||||
case VolumeUnits.m3: return Config.Units.ConvertFrom(Config.Unit.m3, 1.0); /// liter
|
||||
case VolumeUnits.UK_gallon: return Config.Units.ConvertFrom(Config.Unit.gal_UK, 1.0); /// liter
|
||||
case VolumeUnits.US_gallon: return Config.Units.ConvertFrom(Config.Unit.gal_US, 1.0); /// liter
|
||||
}
|
||||
}
|
||||
|
||||
public double ScalingFactor()
|
||||
{
|
||||
if ((iperlHeadCfg.MeterType == MeterType.AutoDetect) && (CalibrationStruct != null))
|
||||
{
|
||||
return IperlHead.ScalingFactor(CalibrationStruct.MeterType);
|
||||
}
|
||||
else if (iperlHeadCfg.MeterType != MeterType.AutoDetect)
|
||||
{
|
||||
return IperlHead.ScalingFactor(iperlHeadCfg.MeterType);
|
||||
}
|
||||
else
|
||||
{
|
||||
return IperlHead.ScalingFactor(MeterType.DN20);
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Scaling factor:
|
||||
/// 0, 1 (DN15, Coax) . . . . 1
|
||||
/// 2 (DN20) . . . . . . . . 2
|
||||
/// 3 (DN25) . . . . . . . . 4
|
||||
/// 4, 5 (DN26, DN32) . . . . 8
|
||||
/// 6 (DN40) . . . . . . . . 16
|
||||
/// </summary>
|
||||
/// <param name="meterType">MeterType (0..6)</param>
|
||||
/// <returns>Scaling factor</returns>
|
||||
public static double ScalingFactor(MeterType meterType)
|
||||
{
|
||||
switch (meterType)
|
||||
{
|
||||
default:
|
||||
case MeterType.DN15:
|
||||
case MeterType.CoaxManifold: return 1.0;
|
||||
case MeterType.DN20: return 2.0;
|
||||
case MeterType.DN25: return 4.0;
|
||||
case MeterType.DN26:
|
||||
case MeterType.DN32: return 8.0;
|
||||
case MeterType.DN40: return 16.0;
|
||||
}
|
||||
}
|
||||
|
||||
int PositionNrFormWMName(string name)
|
||||
{
|
||||
int len = name.Length;
|
||||
if (len < 2) return 0;
|
||||
|
||||
int loNr = (int)name[len - 1] - (int)'0';
|
||||
int hiNr = (int)name[len - 2] - (int)'0';
|
||||
if (hiNr < 1 || hiNr > 4) hiNr = 0;
|
||||
|
||||
return 10 * hiNr + loNr;
|
||||
}
|
||||
}
|
||||
}
|
||||
+73
@@ -0,0 +1,73 @@
|
||||
///
|
||||
/// Copyright (c) 2015-2017 Sensus Metering Systems
|
||||
///
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.IO;
|
||||
using System.Net;
|
||||
using System.Net.Sockets;
|
||||
using System.Xml.Serialization;
|
||||
using Config.Entities;
|
||||
using TBF.BenchControl.Generic;
|
||||
using TBF.Resources;
|
||||
|
||||
namespace TBF.BenchControl.TestMethods.iPerlCommunication.iPerlHead
|
||||
{
|
||||
public class IperlHeadCfg : ComponentCfgBase, Generic.IComponentCfg
|
||||
{
|
||||
public IComponentCfgCtrl GetControl() { return new IperlHeadCfgCtrl(); }
|
||||
|
||||
///
|
||||
/// Serialized parameters
|
||||
///
|
||||
public bool UseTcpIP;
|
||||
public string OptoIPAddress;
|
||||
public ushort OptoTcpipPortNr;
|
||||
public int OptoComPortNr;
|
||||
public int RfidComPortNr; /// 0 = use MuxBoardNr
|
||||
public int MuxBoardNr; /// 0 = use RfidComPort(Nr), otherwise mux. board nr. 1 .. 4
|
||||
public int Group; /// Number written to QuidoRS to connct the watermeter to RfidComPort
|
||||
|
||||
/// <summary> Procedure parameters </summary>
|
||||
[XmlIgnore]
|
||||
public ProcParams ProcParams;
|
||||
public override IParamsProvider GetProcedureParams() { return ProcParams; }
|
||||
public override IParamsProvider CreateProcedureParams(Procedure procedure)
|
||||
{
|
||||
ProcParams procParams = new ProcParams(true);
|
||||
procParams.UpdateProcedureParams(Name, procedure);
|
||||
return procParams;
|
||||
}
|
||||
|
||||
[XmlIgnore]
|
||||
public MeterType MeterType { get { return (ProcParams != null) ? ProcParams.MeterType : MeterType.AutoDetect; } }
|
||||
|
||||
|
||||
/// Private parameterless constructor invoked by all other (public) constructors
|
||||
IperlHeadCfg()
|
||||
{
|
||||
Name = "iPerl";
|
||||
ParentName = string.Empty;
|
||||
OptoComPortNr = 10;
|
||||
RfidComPortNr = 0; /// = use mux. board
|
||||
MuxBoardNr = 1;
|
||||
ProcParams = new ProcParams(true);
|
||||
}
|
||||
|
||||
public IperlHeadCfg(IComponentFactory factory)
|
||||
: this()
|
||||
{
|
||||
this.Factory = factory;
|
||||
}
|
||||
|
||||
public string ToString(int i)
|
||||
{
|
||||
return string.Format("Name={0}, Opto=COM{1}, RFID=COM{2}, MuxBoard#={3}, Group={4}",
|
||||
Name,
|
||||
OptoComPortNr,
|
||||
RfidComPortNr,
|
||||
MuxBoardNr,
|
||||
Group);
|
||||
}
|
||||
}
|
||||
}
|
||||
+161
@@ -0,0 +1,161 @@
|
||||
///
|
||||
/// Copyright (c) 2015-2017 Sensus Metering Systems
|
||||
///
|
||||
using System;
|
||||
using System.Net;
|
||||
using System.Net.Sockets;
|
||||
using System.Windows.Forms;
|
||||
using log4net;
|
||||
using TBF.BenchControl.Generic;
|
||||
using TBF.Resources;
|
||||
|
||||
namespace TBF.BenchControl.TestMethods.iPerlCommunication.iPerlHead
|
||||
{
|
||||
public partial class IperlHeadCfgCtrl : UserControl, IComponentCfgCtrl
|
||||
{
|
||||
static readonly ILog log = LogManager.GetLogger(typeof(IperlHeadCfgCtrl));
|
||||
|
||||
public bool ShowMore { get { return false; } }
|
||||
|
||||
IperlHeadCfg config;
|
||||
public IComponentCfg Config
|
||||
{
|
||||
get { return config as IComponentCfg; }
|
||||
set
|
||||
{
|
||||
config = value as IperlHeadCfg;
|
||||
Redraw();
|
||||
}
|
||||
}
|
||||
|
||||
public IperlHeadCfgCtrl()
|
||||
{
|
||||
InitializeComponent();
|
||||
}
|
||||
|
||||
private void WaterMeterCfgCtrl_Load(object sender, EventArgs e)
|
||||
{
|
||||
nameLabel.Text = Strings.Name;
|
||||
classNameLabel.Text = config.Factory.ClassName;
|
||||
Redraw();
|
||||
}
|
||||
|
||||
public void Closing()
|
||||
{
|
||||
}
|
||||
|
||||
void Redraw()
|
||||
{
|
||||
if (config == null) return; /// Control was not loaded, settings were not changed
|
||||
nameTextBox.Text = config.Name;
|
||||
radioButton1.Checked = config.UseTcpIP;
|
||||
radioButton2.Checked = !config.UseTcpIP;
|
||||
ipAddressTextBox.Text = (config.OptoIPAddress != null) ? config.OptoIPAddress : "0.0.0.0";
|
||||
tcpipPortTextBox.Text = config.OptoTcpipPortNr.ToString();
|
||||
optoSerialPortTextBox.Text = config.OptoComPortNr.ToString();
|
||||
rfidPortNrTextBox.Text = config.RfidComPortNr.ToString();
|
||||
muxBoardNrTextBox.Text = config.MuxBoardNr.ToString();
|
||||
groupTextBox.Text = config.Group.ToString();
|
||||
}
|
||||
|
||||
public void Unlock()
|
||||
{
|
||||
nameTextBox.Enabled = true;
|
||||
radioButton1.Enabled = true;
|
||||
radioButton2.Enabled = true;
|
||||
ipAddressTextBox.Enabled = true;
|
||||
tcpipPortTextBox.Enabled = true;
|
||||
optoSerialPortTextBox.Enabled = true;
|
||||
rfidPortNrTextBox.Enabled = true;
|
||||
muxBoardNrTextBox.Enabled = true;
|
||||
groupTextBox.Enabled = true;
|
||||
}
|
||||
|
||||
public CfgUpdateFlags VerifyCfg(ref string message)
|
||||
{
|
||||
CfgUpdateFlags flags = CfgUpdateFlags.None;
|
||||
|
||||
int dummy, dummy2;
|
||||
if (radioButton1.Checked)
|
||||
{
|
||||
IPAddress dummyIPAddress;
|
||||
if (!IPAddress.TryParse(ipAddressTextBox.Text, out dummyIPAddress))
|
||||
{
|
||||
flags |= CfgUpdateFlags.Error;
|
||||
message += Environment.NewLine + "'IP address' is not valid";
|
||||
}
|
||||
|
||||
ushort sdummy;
|
||||
if (!ushort.TryParse(tcpipPortTextBox.Text, out sdummy))
|
||||
{
|
||||
flags |= CfgUpdateFlags.Error;
|
||||
message += Environment.NewLine + "'TCP/IP port nr.' is not valid";
|
||||
}
|
||||
}
|
||||
else
|
||||
{
|
||||
if (!int.TryParse(optoSerialPortTextBox.Text, out dummy) || dummy < 1 || dummy > 999)
|
||||
{
|
||||
flags |= CfgUpdateFlags.Error;
|
||||
message += Environment.NewLine + "'Opto serial port nr.' is not valid";
|
||||
}
|
||||
}
|
||||
|
||||
if (!int.TryParse(rfidPortNrTextBox.Text, out dummy) || dummy < 0 || dummy > 999)
|
||||
{
|
||||
flags |= CfgUpdateFlags.Error;
|
||||
message += Environment.NewLine + "'RFID serial port nr.' is not valid";
|
||||
}
|
||||
if (!int.TryParse(muxBoardNrTextBox.Text, out dummy2) || dummy2 < 0 || dummy2 > 4)
|
||||
{
|
||||
flags |= CfgUpdateFlags.Error;
|
||||
message += Environment.NewLine + "'Mux. board nr.' is not valid";
|
||||
}
|
||||
if (dummy == 0 && dummy2 == 0)
|
||||
{
|
||||
flags |= CfgUpdateFlags.Error;
|
||||
message += Environment.NewLine + "Either 'RFID serial port nr.' or 'Mux. board nr.' should be nonzero";
|
||||
}
|
||||
if (dummy != 0 && dummy2 != 0)
|
||||
{
|
||||
flags |= CfgUpdateFlags.Error;
|
||||
message += Environment.NewLine + "Either 'RFID serial port nr.' or 'Mux. board nr.' should be zero";
|
||||
}
|
||||
|
||||
if (!int.TryParse(groupTextBox.Text, out dummy) || dummy < 1 || dummy > 10)
|
||||
{
|
||||
flags |= CfgUpdateFlags.Error;
|
||||
message += Environment.NewLine + "'Group' is not valid";
|
||||
}
|
||||
|
||||
return flags;
|
||||
}
|
||||
|
||||
public CfgUpdateFlags UpdateCfg()
|
||||
{
|
||||
CfgUpdateFlags flags = CfgUpdateFlags.RestartRqrd;
|
||||
|
||||
if (config == null) return CfgUpdateFlags.Error; /// Control was not loaded, settings were not changed
|
||||
|
||||
config.Name = nameTextBox.Text;
|
||||
|
||||
if (radioButton1.Checked)
|
||||
{
|
||||
config.UseTcpIP = true;
|
||||
config.OptoIPAddress = ipAddressTextBox.Text;
|
||||
config.OptoTcpipPortNr = ushort.Parse(tcpipPortTextBox.Text);
|
||||
}
|
||||
else
|
||||
{
|
||||
config.UseTcpIP = false;
|
||||
config.OptoComPortNr = int.Parse(optoSerialPortTextBox.Text);
|
||||
}
|
||||
|
||||
config.RfidComPortNr = int.Parse(rfidPortNrTextBox.Text);
|
||||
config.MuxBoardNr = int.Parse(muxBoardNrTextBox.Text);
|
||||
config.Group = int.Parse(groupTextBox.Text);
|
||||
|
||||
return flags;
|
||||
}
|
||||
}
|
||||
}
|
||||
+269
@@ -0,0 +1,269 @@
|
||||
///
|
||||
/// Copyright (c) 2015-2017 Sensus Metering Systems
|
||||
///
|
||||
namespace TBF.BenchControl.TestMethods.iPerlCommunication.iPerlHead
|
||||
{
|
||||
partial class IperlHeadCfgCtrl
|
||||
{
|
||||
/// <summary>
|
||||
/// Required designer variable.
|
||||
/// </summary>
|
||||
private System.ComponentModel.IContainer components = null;
|
||||
|
||||
/// <summary>
|
||||
/// Clean up any resources being used.
|
||||
/// </summary>
|
||||
/// <param name="disposing">true if managed resources should be disposed; otherwise, false.</param>
|
||||
protected override void Dispose(bool disposing)
|
||||
{
|
||||
if (disposing && (components != null))
|
||||
{
|
||||
components.Dispose();
|
||||
}
|
||||
base.Dispose(disposing);
|
||||
}
|
||||
|
||||
#region Component Designer generated code
|
||||
|
||||
/// <summary>
|
||||
/// Required method for Designer support - do not modify
|
||||
/// the contents of this method with the code editor.
|
||||
/// </summary>
|
||||
private void InitializeComponent()
|
||||
{
|
||||
this.nameTextBox = new System.Windows.Forms.TextBox();
|
||||
this.nameLabel = new System.Windows.Forms.Label();
|
||||
this.classNameLabel = new System.Windows.Forms.Label();
|
||||
this.optoSerialPortTextBox = new System.Windows.Forms.TextBox();
|
||||
this.optoSerialPortLabel = new System.Windows.Forms.Label();
|
||||
this.muxBoardNrTextBox = new System.Windows.Forms.TextBox();
|
||||
this.muxBoardNrLabel = new System.Windows.Forms.Label();
|
||||
this.groupTextBox = new System.Windows.Forms.TextBox();
|
||||
this.groupLabel = new System.Windows.Forms.Label();
|
||||
this.rfidPortNrTextBox = new System.Windows.Forms.TextBox();
|
||||
this.rfidSerialPortNrLabel = new System.Windows.Forms.Label();
|
||||
this.radioButton1 = new System.Windows.Forms.RadioButton();
|
||||
this.radioButton2 = new System.Windows.Forms.RadioButton();
|
||||
this.optoDataGroupBox = new System.Windows.Forms.GroupBox();
|
||||
this.tcpipPortLabel = new System.Windows.Forms.Label();
|
||||
this.tcpipPortTextBox = new System.Windows.Forms.TextBox();
|
||||
this.ipAddressLabel = new System.Windows.Forms.Label();
|
||||
this.ipAddressTextBox = new System.Windows.Forms.TextBox();
|
||||
this.optoDataGroupBox.SuspendLayout();
|
||||
this.SuspendLayout();
|
||||
//
|
||||
// nameTextBox
|
||||
//
|
||||
this.nameTextBox.Enabled = false;
|
||||
this.nameTextBox.Location = new System.Drawing.Point(135, 39);
|
||||
this.nameTextBox.Name = "nameTextBox";
|
||||
this.nameTextBox.Size = new System.Drawing.Size(121, 20);
|
||||
this.nameTextBox.TabIndex = 2;
|
||||
//
|
||||
// nameLabel
|
||||
//
|
||||
this.nameLabel.AutoSize = true;
|
||||
this.nameLabel.Location = new System.Drawing.Point(25, 42);
|
||||
this.nameLabel.Name = "nameLabel";
|
||||
this.nameLabel.Size = new System.Drawing.Size(35, 13);
|
||||
this.nameLabel.TabIndex = 1;
|
||||
this.nameLabel.Text = "Name";
|
||||
//
|
||||
// classNameLabel
|
||||
//
|
||||
this.classNameLabel.AutoSize = true;
|
||||
this.classNameLabel.Location = new System.Drawing.Point(132, 18);
|
||||
this.classNameLabel.Name = "classNameLabel";
|
||||
this.classNameLabel.Size = new System.Drawing.Size(60, 13);
|
||||
this.classNameLabel.TabIndex = 0;
|
||||
this.classNameLabel.Text = "ClassName";
|
||||
//
|
||||
// optoSerialPortTextBox
|
||||
//
|
||||
this.optoSerialPortTextBox.Enabled = false;
|
||||
this.optoSerialPortTextBox.Location = new System.Drawing.Point(329, 42);
|
||||
this.optoSerialPortTextBox.Name = "optoSerialPortTextBox";
|
||||
this.optoSerialPortTextBox.Size = new System.Drawing.Size(34, 20);
|
||||
this.optoSerialPortTextBox.TabIndex = 7;
|
||||
//
|
||||
// optoSerialPortLabel
|
||||
//
|
||||
this.optoSerialPortLabel.AutoSize = true;
|
||||
this.optoSerialPortLabel.Location = new System.Drawing.Point(241, 45);
|
||||
this.optoSerialPortLabel.Name = "optoSerialPortLabel";
|
||||
this.optoSerialPortLabel.Size = new System.Drawing.Size(72, 13);
|
||||
this.optoSerialPortLabel.TabIndex = 6;
|
||||
this.optoSerialPortLabel.Text = "Serial port nr.:";
|
||||
//
|
||||
// muxBoardNrTextBox
|
||||
//
|
||||
this.muxBoardNrTextBox.Enabled = false;
|
||||
this.muxBoardNrTextBox.Location = new System.Drawing.Point(135, 207);
|
||||
this.muxBoardNrTextBox.Name = "muxBoardNrTextBox";
|
||||
this.muxBoardNrTextBox.Size = new System.Drawing.Size(34, 20);
|
||||
this.muxBoardNrTextBox.TabIndex = 9;
|
||||
//
|
||||
// muxBoardNrLabel
|
||||
//
|
||||
this.muxBoardNrLabel.AutoSize = true;
|
||||
this.muxBoardNrLabel.Location = new System.Drawing.Point(25, 210);
|
||||
this.muxBoardNrLabel.Name = "muxBoardNrLabel";
|
||||
this.muxBoardNrLabel.Size = new System.Drawing.Size(78, 13);
|
||||
this.muxBoardNrLabel.TabIndex = 8;
|
||||
this.muxBoardNrLabel.Text = "Mux. board nr.:";
|
||||
//
|
||||
// groupTextBox
|
||||
//
|
||||
this.groupTextBox.Enabled = false;
|
||||
this.groupTextBox.Location = new System.Drawing.Point(135, 230);
|
||||
this.groupTextBox.Name = "groupTextBox";
|
||||
this.groupTextBox.Size = new System.Drawing.Size(34, 20);
|
||||
this.groupTextBox.TabIndex = 11;
|
||||
//
|
||||
// groupLabel
|
||||
//
|
||||
this.groupLabel.AutoSize = true;
|
||||
this.groupLabel.Location = new System.Drawing.Point(25, 233);
|
||||
this.groupLabel.Name = "groupLabel";
|
||||
this.groupLabel.Size = new System.Drawing.Size(39, 13);
|
||||
this.groupLabel.TabIndex = 10;
|
||||
this.groupLabel.Text = "Group:";
|
||||
//
|
||||
// rfidPortNrTextBox
|
||||
//
|
||||
this.rfidPortNrTextBox.Enabled = false;
|
||||
this.rfidPortNrTextBox.Location = new System.Drawing.Point(135, 184);
|
||||
this.rfidPortNrTextBox.Name = "rfidPortNrTextBox";
|
||||
this.rfidPortNrTextBox.Size = new System.Drawing.Size(34, 20);
|
||||
this.rfidPortNrTextBox.TabIndex = 7;
|
||||
//
|
||||
// rfidSerialPortNrLabel
|
||||
//
|
||||
this.rfidSerialPortNrLabel.AutoSize = true;
|
||||
this.rfidSerialPortNrLabel.Location = new System.Drawing.Point(25, 187);
|
||||
this.rfidSerialPortNrLabel.Name = "rfidSerialPortNrLabel";
|
||||
this.rfidSerialPortNrLabel.Size = new System.Drawing.Size(98, 13);
|
||||
this.rfidSerialPortNrLabel.TabIndex = 6;
|
||||
this.rfidSerialPortNrLabel.Text = "RFID serial port nr.:";
|
||||
//
|
||||
// radioButton1
|
||||
//
|
||||
this.radioButton1.AutoSize = true;
|
||||
this.radioButton1.Enabled = false;
|
||||
this.radioButton1.Location = new System.Drawing.Point(22, 19);
|
||||
this.radioButton1.Name = "radioButton1";
|
||||
this.radioButton1.Size = new System.Drawing.Size(83, 17);
|
||||
this.radioButton1.TabIndex = 0;
|
||||
this.radioButton1.TabStop = true;
|
||||
this.radioButton1.Text = "Use TCP/IP";
|
||||
this.radioButton1.UseVisualStyleBackColor = true;
|
||||
//
|
||||
// radioButton2
|
||||
//
|
||||
this.radioButton2.AutoSize = true;
|
||||
this.radioButton2.Enabled = false;
|
||||
this.radioButton2.Location = new System.Drawing.Point(234, 19);
|
||||
this.radioButton2.Name = "radioButton2";
|
||||
this.radioButton2.Size = new System.Drawing.Size(92, 17);
|
||||
this.radioButton2.TabIndex = 1;
|
||||
this.radioButton2.TabStop = true;
|
||||
this.radioButton2.Text = "Use serial port";
|
||||
this.radioButton2.UseVisualStyleBackColor = true;
|
||||
//
|
||||
// optoDataGroupBox
|
||||
//
|
||||
this.optoDataGroupBox.Controls.Add(this.tcpipPortLabel);
|
||||
this.optoDataGroupBox.Controls.Add(this.tcpipPortTextBox);
|
||||
this.optoDataGroupBox.Controls.Add(this.ipAddressLabel);
|
||||
this.optoDataGroupBox.Controls.Add(this.ipAddressTextBox);
|
||||
this.optoDataGroupBox.Controls.Add(this.radioButton1);
|
||||
this.optoDataGroupBox.Controls.Add(this.radioButton2);
|
||||
this.optoDataGroupBox.Controls.Add(this.optoSerialPortLabel);
|
||||
this.optoDataGroupBox.Controls.Add(this.optoSerialPortTextBox);
|
||||
this.optoDataGroupBox.Location = new System.Drawing.Point(28, 67);
|
||||
this.optoDataGroupBox.Name = "optoDataGroupBox";
|
||||
this.optoDataGroupBox.Size = new System.Drawing.Size(414, 101);
|
||||
this.optoDataGroupBox.TabIndex = 5;
|
||||
this.optoDataGroupBox.TabStop = false;
|
||||
this.optoDataGroupBox.Text = "Opto-data";
|
||||
//
|
||||
// tcpipPortLabel
|
||||
//
|
||||
this.tcpipPortLabel.AutoSize = true;
|
||||
this.tcpipPortLabel.Location = new System.Drawing.Point(31, 71);
|
||||
this.tcpipPortLabel.Name = "tcpipPortLabel";
|
||||
this.tcpipPortLabel.Size = new System.Drawing.Size(47, 13);
|
||||
this.tcpipPortLabel.TabIndex = 4;
|
||||
this.tcpipPortLabel.Text = "Port nr..:";
|
||||
//
|
||||
// tcpipPortTextBox
|
||||
//
|
||||
this.tcpipPortTextBox.Enabled = false;
|
||||
this.tcpipPortTextBox.Location = new System.Drawing.Point(107, 68);
|
||||
this.tcpipPortTextBox.Name = "tcpipPortTextBox";
|
||||
this.tcpipPortTextBox.Size = new System.Drawing.Size(39, 20);
|
||||
this.tcpipPortTextBox.TabIndex = 5;
|
||||
//
|
||||
// ipAddressLabel
|
||||
//
|
||||
this.ipAddressLabel.AutoSize = true;
|
||||
this.ipAddressLabel.Location = new System.Drawing.Point(31, 48);
|
||||
this.ipAddressLabel.Name = "ipAddressLabel";
|
||||
this.ipAddressLabel.Size = new System.Drawing.Size(63, 13);
|
||||
this.ipAddressLabel.TabIndex = 2;
|
||||
this.ipAddressLabel.Text = "IP address.:";
|
||||
//
|
||||
// ipAddressTextBox
|
||||
//
|
||||
this.ipAddressTextBox.Enabled = false;
|
||||
this.ipAddressTextBox.Location = new System.Drawing.Point(107, 45);
|
||||
this.ipAddressTextBox.Name = "ipAddressTextBox";
|
||||
this.ipAddressTextBox.Size = new System.Drawing.Size(98, 20);
|
||||
this.ipAddressTextBox.TabIndex = 3;
|
||||
//
|
||||
// WaterMeterCfgCtrl
|
||||
//
|
||||
this.AutoScaleDimensions = new System.Drawing.SizeF(6F, 13F);
|
||||
this.AutoScaleMode = System.Windows.Forms.AutoScaleMode.Font;
|
||||
this.Controls.Add(this.optoDataGroupBox);
|
||||
this.Controls.Add(this.rfidPortNrTextBox);
|
||||
this.Controls.Add(this.rfidSerialPortNrLabel);
|
||||
this.Controls.Add(this.groupTextBox);
|
||||
this.Controls.Add(this.groupLabel);
|
||||
this.Controls.Add(this.muxBoardNrTextBox);
|
||||
this.Controls.Add(this.muxBoardNrLabel);
|
||||
this.Controls.Add(this.nameTextBox);
|
||||
this.Controls.Add(this.nameLabel);
|
||||
this.Controls.Add(this.classNameLabel);
|
||||
this.Name = "WaterMeterCfgCtrl";
|
||||
this.Size = new System.Drawing.Size(500, 300);
|
||||
this.Load += new System.EventHandler(this.WaterMeterCfgCtrl_Load);
|
||||
this.optoDataGroupBox.ResumeLayout(false);
|
||||
this.optoDataGroupBox.PerformLayout();
|
||||
this.ResumeLayout(false);
|
||||
this.PerformLayout();
|
||||
|
||||
}
|
||||
|
||||
#endregion
|
||||
|
||||
private System.Windows.Forms.TextBox nameTextBox;
|
||||
private System.Windows.Forms.Label nameLabel;
|
||||
private System.Windows.Forms.Label classNameLabel;
|
||||
private System.Windows.Forms.TextBox optoSerialPortTextBox;
|
||||
private System.Windows.Forms.Label optoSerialPortLabel;
|
||||
private System.Windows.Forms.TextBox muxBoardNrTextBox;
|
||||
private System.Windows.Forms.Label muxBoardNrLabel;
|
||||
private System.Windows.Forms.TextBox groupTextBox;
|
||||
private System.Windows.Forms.Label groupLabel;
|
||||
private System.Windows.Forms.TextBox rfidPortNrTextBox;
|
||||
private System.Windows.Forms.Label rfidSerialPortNrLabel;
|
||||
private System.Windows.Forms.RadioButton radioButton1;
|
||||
private System.Windows.Forms.RadioButton radioButton2;
|
||||
private System.Windows.Forms.GroupBox optoDataGroupBox;
|
||||
private System.Windows.Forms.Label tcpipPortLabel;
|
||||
private System.Windows.Forms.TextBox tcpipPortTextBox;
|
||||
private System.Windows.Forms.Label ipAddressLabel;
|
||||
private System.Windows.Forms.TextBox ipAddressTextBox;
|
||||
}
|
||||
}
|
||||
+120
@@ -0,0 +1,120 @@
|
||||
<?xml version="1.0" encoding="utf-8"?>
|
||||
<root>
|
||||
<!--
|
||||
Microsoft ResX Schema
|
||||
|
||||
Version 2.0
|
||||
|
||||
The primary goals of this format is to allow a simple XML format
|
||||
that is mostly human readable. The generation and parsing of the
|
||||
various data types are done through the TypeConverter classes
|
||||
associated with the data types.
|
||||
|
||||
Example:
|
||||
|
||||
... ado.net/XML headers & schema ...
|
||||
<resheader name="resmimetype">text/microsoft-resx</resheader>
|
||||
<resheader name="version">2.0</resheader>
|
||||
<resheader name="reader">System.Resources.ResXResourceReader, System.Windows.Forms, ...</resheader>
|
||||
<resheader name="writer">System.Resources.ResXResourceWriter, System.Windows.Forms, ...</resheader>
|
||||
<data name="Name1"><value>this is my long string</value><comment>this is a comment</comment></data>
|
||||
<data name="Color1" type="System.Drawing.Color, System.Drawing">Blue</data>
|
||||
<data name="Bitmap1" mimetype="application/x-microsoft.net.object.binary.base64">
|
||||
<value>[base64 mime encoded serialized .NET Framework object]</value>
|
||||
</data>
|
||||
<data name="Icon1" type="System.Drawing.Icon, System.Drawing" mimetype="application/x-microsoft.net.object.bytearray.base64">
|
||||
<value>[base64 mime encoded string representing a byte array form of the .NET Framework object]</value>
|
||||
<comment>This is a comment</comment>
|
||||
</data>
|
||||
|
||||
There are any number of "resheader" rows that contain simple
|
||||
name/value pairs.
|
||||
|
||||
Each data row contains a name, and value. The row also contains a
|
||||
type or mimetype. Type corresponds to a .NET class that support
|
||||
text/value conversion through the TypeConverter architecture.
|
||||
Classes that don't support this are serialized and stored with the
|
||||
mimetype set.
|
||||
|
||||
The mimetype is used for serialized objects, and tells the
|
||||
ResXResourceReader how to depersist the object. This is currently not
|
||||
extensible. For a given mimetype the value must be set accordingly:
|
||||
|
||||
Note - application/x-microsoft.net.object.binary.base64 is the format
|
||||
that the ResXResourceWriter will generate, however the reader can
|
||||
read any of the formats listed below.
|
||||
|
||||
mimetype: application/x-microsoft.net.object.binary.base64
|
||||
value : The object must be serialized with
|
||||
: System.Runtime.Serialization.Formatters.Binary.BinaryFormatter
|
||||
: and then encoded with base64 encoding.
|
||||
|
||||
mimetype: application/x-microsoft.net.object.soap.base64
|
||||
value : The object must be serialized with
|
||||
: System.Runtime.Serialization.Formatters.Soap.SoapFormatter
|
||||
: and then encoded with base64 encoding.
|
||||
|
||||
mimetype: application/x-microsoft.net.object.bytearray.base64
|
||||
value : The object must be serialized into a byte array
|
||||
: using a System.ComponentModel.TypeConverter
|
||||
: and then encoded with base64 encoding.
|
||||
-->
|
||||
<xsd:schema id="root" xmlns="" xmlns:xsd="http://www.w3.org/2001/XMLSchema" xmlns:msdata="urn:schemas-microsoft-com:xml-msdata">
|
||||
<xsd:import namespace="http://www.w3.org/XML/1998/namespace" />
|
||||
<xsd:element name="root" msdata:IsDataSet="true">
|
||||
<xsd:complexType>
|
||||
<xsd:choice maxOccurs="unbounded">
|
||||
<xsd:element name="metadata">
|
||||
<xsd:complexType>
|
||||
<xsd:sequence>
|
||||
<xsd:element name="value" type="xsd:string" minOccurs="0" />
|
||||
</xsd:sequence>
|
||||
<xsd:attribute name="name" use="required" type="xsd:string" />
|
||||
<xsd:attribute name="type" type="xsd:string" />
|
||||
<xsd:attribute name="mimetype" type="xsd:string" />
|
||||
<xsd:attribute ref="xml:space" />
|
||||
</xsd:complexType>
|
||||
</xsd:element>
|
||||
<xsd:element name="assembly">
|
||||
<xsd:complexType>
|
||||
<xsd:attribute name="alias" type="xsd:string" />
|
||||
<xsd:attribute name="name" type="xsd:string" />
|
||||
</xsd:complexType>
|
||||
</xsd:element>
|
||||
<xsd:element name="data">
|
||||
<xsd:complexType>
|
||||
<xsd:sequence>
|
||||
<xsd:element name="value" type="xsd:string" minOccurs="0" msdata:Ordinal="1" />
|
||||
<xsd:element name="comment" type="xsd:string" minOccurs="0" msdata:Ordinal="2" />
|
||||
</xsd:sequence>
|
||||
<xsd:attribute name="name" type="xsd:string" use="required" msdata:Ordinal="1" />
|
||||
<xsd:attribute name="type" type="xsd:string" msdata:Ordinal="3" />
|
||||
<xsd:attribute name="mimetype" type="xsd:string" msdata:Ordinal="4" />
|
||||
<xsd:attribute ref="xml:space" />
|
||||
</xsd:complexType>
|
||||
</xsd:element>
|
||||
<xsd:element name="resheader">
|
||||
<xsd:complexType>
|
||||
<xsd:sequence>
|
||||
<xsd:element name="value" type="xsd:string" minOccurs="0" msdata:Ordinal="1" />
|
||||
</xsd:sequence>
|
||||
<xsd:attribute name="name" type="xsd:string" use="required" />
|
||||
</xsd:complexType>
|
||||
</xsd:element>
|
||||
</xsd:choice>
|
||||
</xsd:complexType>
|
||||
</xsd:element>
|
||||
</xsd:schema>
|
||||
<resheader name="resmimetype">
|
||||
<value>text/microsoft-resx</value>
|
||||
</resheader>
|
||||
<resheader name="version">
|
||||
<value>2.0</value>
|
||||
</resheader>
|
||||
<resheader name="reader">
|
||||
<value>System.Resources.ResXResourceReader, System.Windows.Forms, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089</value>
|
||||
</resheader>
|
||||
<resheader name="writer">
|
||||
<value>System.Resources.ResXResourceWriter, System.Windows.Forms, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089</value>
|
||||
</resheader>
|
||||
</root>
|
||||
+20
@@ -0,0 +1,20 @@
|
||||
///
|
||||
/// Copyright (c) 2015-2017 Sensus Metering Systems
|
||||
///
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.Linq;
|
||||
using System.Text;
|
||||
|
||||
namespace TBF.BenchControl.TestMethods.iPerlCommunication.iPerlHead
|
||||
{
|
||||
public class OptoReceivedEventArgs : EventArgs
|
||||
{
|
||||
public string Data;
|
||||
|
||||
public OptoReceivedEventArgs(string data)
|
||||
{
|
||||
this.Data = data;
|
||||
}
|
||||
}
|
||||
}
|
||||
+296
@@ -0,0 +1,296 @@
|
||||
///
|
||||
/// Copyright (c) 2015-2017 Sensus Metering Systems
|
||||
///
|
||||
using System;
|
||||
using System.Globalization;
|
||||
|
||||
namespace TBF.BenchControl.TestMethods.iPerlCommunication.iPerlHead
|
||||
{
|
||||
public class OptoTelegramRaw
|
||||
{
|
||||
public static readonly int Length = 42;
|
||||
private static CultureInfo culture;
|
||||
|
||||
|
||||
///
|
||||
/// Strobed value
|
||||
///
|
||||
public static decimal TestStartTimestampDec;
|
||||
|
||||
///
|
||||
/// Stored values
|
||||
///
|
||||
public OptoTelegramFlags Flags;
|
||||
|
||||
public DateTime DateTime; /// From PC
|
||||
public float RefFlow; /// [m3/h]
|
||||
public int Counter;
|
||||
|
||||
public UInt32 EmfRaw; /// From iPerl opto data
|
||||
public Int16 MagneticFieldRaw;
|
||||
public Int16 FlowRaw;
|
||||
public UInt32 VolumeRaw;
|
||||
public Int64 VolumeRawExt;
|
||||
public Int16 Impedance;
|
||||
public UInt32 Timestamp;
|
||||
public Int64 TimestampExt;
|
||||
public byte CheckSum;
|
||||
|
||||
///
|
||||
/// Calculated values
|
||||
///
|
||||
public double EMF()
|
||||
{
|
||||
Int32 signedEmf = (EmfRaw > 0x7FFFFF) ? ((int)EmfRaw - 0x1000000) : (int)EmfRaw;
|
||||
return 0.000000333 * (double)signedEmf;
|
||||
}
|
||||
public double MagneticField() { return (double)MagneticFieldRaw; }
|
||||
public double Flow(double scalingFactor) { return 0.225 * scalingFactor * (double)FlowRaw; }
|
||||
public double Volume(double scalingFactor) { return 0.0000625 * scalingFactor * (double)VolumeRawExt; }
|
||||
public Int32 FlipTime() { return Impedance; }
|
||||
public decimal TimestampDec() { return (decimal)TimestampExt / (decimal)8192; }
|
||||
public double VolumeDelta(double scalingFactor, OptoTelegramRaw previous) { return (previous == null) ? 0 : Volume(scalingFactor) - previous.Volume(scalingFactor); }
|
||||
public decimal TimeDelta() { return TimestampDec() - TestStartTimestampDec; }
|
||||
public string Label()
|
||||
{
|
||||
if (Flags == OptoTelegramFlags.OK_TestStart) return "#### start test ####";
|
||||
else if (Flags == OptoTelegramFlags.OK_TestEnd) return "#### end of test ####";
|
||||
else return string.Empty;
|
||||
}
|
||||
|
||||
|
||||
static OptoTelegramRaw()
|
||||
{
|
||||
culture = CultureInfo.CreateSpecificCulture("DE"); /// This is to use comma as decimal number separator
|
||||
}
|
||||
|
||||
public OptoTelegramRaw()
|
||||
{
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Parses optical telegram and returns OptoTelegramRaw object
|
||||
/// </summary>
|
||||
/// <description>
|
||||
/// Create a configuration structure from a complete byte array
|
||||
///
|
||||
/// Telegram description:
|
||||
///
|
||||
/// AAAAAA[tab]BBBB[tab]CCCC[tab]DDDDDD[tab]EEEE[tab]FFFFFFFF[tab]GG[cr][lf] (42 bytes)
|
||||
///
|
||||
/// Data Comment Type Calculate to decimal
|
||||
/// ----------------------------------------------------------------
|
||||
/// AAAAAA EMF Int24 Value * 0.000000333
|
||||
/// BBBB Magnetic field Int16 Value
|
||||
/// CCCC Flow Int16 Value * 0.225 * Scalig factor
|
||||
/// DDDDDD Volume Int24 Value / 16000 * Scaling factor
|
||||
/// EEEE Impedance Int16 Value
|
||||
/// FFFFFFFF Timestamp Uint32 Value / 8192
|
||||
/// GG Checksum Byte
|
||||
/// ----------------------------------------------------------------
|
||||
///
|
||||
/// Example:
|
||||
/// FFFFFE 51EA 0000 65324E 0087 F6319DFF 86
|
||||
/// FFDD3A 51F9 0000 65324E 0088 F631A60B 45
|
||||
/// ...
|
||||
/// </description>
|
||||
/// <param name="data">A complete byte array data</param>
|
||||
/// <returns>true = telegram OK, false = telegram NOK</returns>
|
||||
public bool UpdateFromString(string telegram, int counter, ref Int64 volumeRawExtLast, ref Int64 timestampExtLast)
|
||||
{
|
||||
DateTime = DateTime.Now;
|
||||
Counter = counter;
|
||||
RefFlow = (float)Sequences.ProcessData.RefFlow.Val;
|
||||
|
||||
if ((telegram == null) || (telegram.Length < Length) ||
|
||||
(telegram[6] != '\t') || (telegram[11] != '\t') || (telegram[16] != '\t') ||
|
||||
(telegram[23] != '\t') || (telegram[28] != '\t') || (telegram[37] != '\t') ||
|
||||
(telegram[40] != '\r') || (telegram[41] != '\n'))
|
||||
{
|
||||
Flags = OptoTelegramFlags.InvalidTelegram;
|
||||
return false;
|
||||
}
|
||||
|
||||
bool f1 = UInt32.TryParse(telegram.Substring(0, 6), NumberStyles.HexNumber, CultureInfo.CurrentCulture, out EmfRaw);
|
||||
bool f2 = Int16.TryParse(telegram.Substring(7, 4), NumberStyles.HexNumber, CultureInfo.CurrentCulture, out MagneticFieldRaw);
|
||||
bool f3 = Int16.TryParse(telegram.Substring(12, 4), NumberStyles.HexNumber, CultureInfo.CurrentCulture, out FlowRaw);
|
||||
bool f4 = UInt32.TryParse(telegram.Substring(17, 6), NumberStyles.HexNumber, CultureInfo.CurrentCulture, out VolumeRaw);
|
||||
bool f5 = Int16.TryParse(telegram.Substring(24, 4), NumberStyles.HexNumber, CultureInfo.CurrentCulture, out Impedance);
|
||||
bool f6 = UInt32.TryParse(telegram.Substring(29, 8), NumberStyles.HexNumber, CultureInfo.CurrentCulture, out Timestamp);
|
||||
bool f7 = byte.TryParse(telegram.Substring(38, 2), NumberStyles.HexNumber, CultureInfo.CurrentCulture, out CheckSum);
|
||||
|
||||
bool allOk = f1 && f2 && f3 && f4 && f5 && f6 && f7;
|
||||
Flags = allOk ? OptoTelegramFlags.OK : OptoTelegramFlags.InvalidTelegram;
|
||||
|
||||
///
|
||||
/// Cope with 'VolumeRaw' overflow
|
||||
///
|
||||
Int64 uncorrected = (Int64)(((UInt64)volumeRawExtLast & 0xFFFFFFFFFF000000UL) | VolumeRaw);
|
||||
if (Math.Abs(uncorrected - volumeRawExtLast) <= 0x800000L)
|
||||
{
|
||||
VolumeRawExt = volumeRawExtLast = uncorrected;
|
||||
}
|
||||
else if (Math.Abs(uncorrected + 0x1000000L - volumeRawExtLast) <= 0x800000L)
|
||||
{
|
||||
VolumeRawExt = volumeRawExtLast = uncorrected + 0x1000000L;
|
||||
}
|
||||
else if (Math.Abs(uncorrected - 0x1000000L - volumeRawExtLast) <= 0x800000L)
|
||||
{
|
||||
VolumeRawExt = volumeRawExtLast = uncorrected - 0x1000000L;
|
||||
}
|
||||
else
|
||||
{
|
||||
VolumeRawExt = volumeRawExtLast = uncorrected;
|
||||
}
|
||||
|
||||
///
|
||||
/// Cope with 'Timestamp' overflow
|
||||
///
|
||||
uncorrected = (Int64)(((UInt64)timestampExtLast & 0xFFFFFFFF00000000UL) | Timestamp);
|
||||
if (Math.Abs(uncorrected - timestampExtLast) <= 0x80000000L)
|
||||
{
|
||||
TimestampExt = timestampExtLast = uncorrected;
|
||||
}
|
||||
else if (Math.Abs(uncorrected + 0x100000000L - timestampExtLast) <= 0x80000000L)
|
||||
{
|
||||
TimestampExt = timestampExtLast = uncorrected + 0x100000000L;
|
||||
}
|
||||
else if (Math.Abs(uncorrected - 0x100000000L - timestampExtLast) <= 0x80000000L)
|
||||
{
|
||||
TimestampExt = timestampExtLast = uncorrected - 0x100000000L;
|
||||
}
|
||||
else
|
||||
{
|
||||
TimestampExt = timestampExtLast = uncorrected;
|
||||
}
|
||||
|
||||
return allOk;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Alternative to UpdateFromString(...) when data are flushed
|
||||
/// </summary>
|
||||
public bool UpdateFromStringDummy(string telegram)
|
||||
{
|
||||
DateTime = DateTime.Now;
|
||||
RefFlow = (float)Sequences.ProcessData.RefFlow.Val;
|
||||
|
||||
if ((telegram == null) || (telegram.Length < Length) ||
|
||||
(telegram[6] != '\t') || (telegram[11] != '\t') || (telegram[16] != '\t') ||
|
||||
(telegram[23] != '\t') || (telegram[28] != '\t') || (telegram[37] != '\t') ||
|
||||
(telegram[40] != '\r') || (telegram[41] != '\n'))
|
||||
{
|
||||
Flags = OptoTelegramFlags.InvalidTelegram;
|
||||
return false;
|
||||
}
|
||||
|
||||
//bool f1 = UInt32.TryParse(telegram.Substring(0, 6), NumberStyles.HexNumber, CultureInfo.CurrentCulture, out EmfRaw);
|
||||
//bool f2 = Int16.TryParse(telegram.Substring(7, 4), NumberStyles.HexNumber, CultureInfo.CurrentCulture, out MagneticFieldRaw);
|
||||
//bool f3 = Int16.TryParse(telegram.Substring(12, 4), NumberStyles.HexNumber, CultureInfo.CurrentCulture, out FlowRaw);
|
||||
//bool f4 = UInt32.TryParse(telegram.Substring(17, 6), NumberStyles.HexNumber, CultureInfo.CurrentCulture, out VolumeRaw);
|
||||
//bool f5 = Int16.TryParse(telegram.Substring(24, 4), NumberStyles.HexNumber, CultureInfo.CurrentCulture, out Impedance);
|
||||
//bool f6 = UInt32.TryParse(telegram.Substring(29, 8), NumberStyles.HexNumber, CultureInfo.CurrentCulture, out Timestamp);
|
||||
//bool f7 = byte.TryParse(telegram.Substring(38, 2), NumberStyles.HexNumber, CultureInfo.CurrentCulture, out CheckSum);
|
||||
//return f1 && f2 && f3 && f4 && f5 && f6 && f7;
|
||||
|
||||
return true;
|
||||
}
|
||||
|
||||
|
||||
public void SetFlags(OptoTelegramFlags flags)
|
||||
{
|
||||
this.Flags = flags;
|
||||
}
|
||||
|
||||
|
||||
public string ToString(double scalingFactor, OptoTelegramRaw previous)
|
||||
{
|
||||
if (Flags == OptoTelegramFlags.SyncError)
|
||||
{
|
||||
return "Sychronization error";
|
||||
}
|
||||
else if (Flags == OptoTelegramFlags.InvalidTelegram)
|
||||
{
|
||||
return "Invalid telegram";
|
||||
}
|
||||
else /// if (flags == OptoTelegramFlags.OK / OptoTelegramFlags.OK_TestStart / OptoTelegramFlags.OK_TestEnd)
|
||||
{
|
||||
return string.Format("{0}:{1}:{2}.{3}\t{4} :\t{5}\t{6}\t{7}\t{8}\t{9}\t{10}\t{11}\t{12}\t{13}\t{14}\t{15}\t{16}\t{17}\t{18}\t{19}\t{20}\t{21}\t{22}",
|
||||
DateTime.Hour.ToString("D2"),
|
||||
DateTime.Minute.ToString("D2"),
|
||||
DateTime.Second.ToString("D2"),
|
||||
DateTime.Millisecond.ToString("D4"),
|
||||
Counter,
|
||||
EmfRaw.ToString("X6"),
|
||||
MagneticFieldRaw.ToString("X4"),
|
||||
FlowRaw.ToString("X4"),
|
||||
VolumeRaw.ToString("X6"),
|
||||
Impedance.ToString("X4"),
|
||||
Timestamp.ToString("X8"),
|
||||
CheckSum.ToString("X2"),
|
||||
EMF().ToString("F4", culture),
|
||||
MagneticField().ToString("F0", culture),
|
||||
Flow(scalingFactor).ToString("F2", culture),
|
||||
Volume(scalingFactor).ToString("F4", culture),
|
||||
FlipTime().ToString("F0", culture),
|
||||
TimestampDec().ToString("F4", culture),
|
||||
(RefFlow * 1000).ToString("F2", culture),
|
||||
VolumeDelta(scalingFactor, previous).ToString("F4", culture),
|
||||
TimeDelta().ToString("F3", culture),
|
||||
scalingFactor.ToString("F1", culture),
|
||||
Label());
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Filter RefFlow data in an array of OptoTelegramRaw objects by a FIR filter:
|
||||
///
|
||||
/// kSize = 5, kSize2 = 2
|
||||
///
|
||||
/// i k
|
||||
/// ---------------------------------------------------------------------------
|
||||
/// 0 -5 filtered[0] = data[0]
|
||||
/// 1 -4 filtered[1] = data[1]
|
||||
/// 2 -3 filtered[2] = data[0]*k[0] + ... + data[4]*k[4]
|
||||
/// 3 -2 filtered[3] = data[1]*k[0] + ... + data[5]*k[4]
|
||||
/// 4 -1 filtered[4] = data[2]*k[0] + ... + data[6]*k[4]
|
||||
/// 5 0 data[0] = filtered[0], filtered[0] = data[3]*k[0] + ... + data[7]*k[4]
|
||||
/// 6 1 data[1] = filtered[1], filtered[1] = data[4]*k[0] + ... + data[8]*k[4]
|
||||
/// 7 ...
|
||||
/// </summary>
|
||||
/// <param name="optoData">array of OptoTelegramRaw objects</param>
|
||||
/// <param name="optoDataCount">number of objects to process</param>
|
||||
public static void FIRFilterFlow(OptoTelegramRaw[] optoData, int optoDataCount)
|
||||
{
|
||||
float[] kernel = new float[] { 0.1f, 0.2f, 0.4f, 0.2f, 0.1f };
|
||||
int kSize = kernel.Length;
|
||||
int kSize2 = kernel.Length / 2;
|
||||
|
||||
float[] filtered = new float[kSize];
|
||||
|
||||
for (int i = 0; i < optoDataCount; i++)
|
||||
{
|
||||
int k = i - kSize;
|
||||
if (k >= 0) optoData[k].RefFlow = filtered[i % kSize];
|
||||
|
||||
if (i < kSize2 || i >= optoDataCount - kSize2)
|
||||
{
|
||||
filtered[i % kSize] = optoData[i].RefFlow;
|
||||
}
|
||||
else
|
||||
{
|
||||
float weoightedSum = 0;
|
||||
for (int j = -kSize2; j <= kSize2; j++)
|
||||
weoightedSum += optoData[i + j].RefFlow * kernel[j + kSize2];
|
||||
|
||||
filtered[i % kSize] = weoightedSum;
|
||||
}
|
||||
}
|
||||
|
||||
for (int k = optoDataCount - kSize; k < optoDataCount; k++)
|
||||
{
|
||||
if (k >= 0) optoData[k].RefFlow = filtered[k % kSize];
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
+169
@@ -0,0 +1,169 @@
|
||||
///
|
||||
/// Copyright (c) 2015-2017 Sensus Metering Systems
|
||||
///
|
||||
using System;
|
||||
using System.IO;
|
||||
using System.Text;
|
||||
using System.Xml.Serialization;
|
||||
using Config.Entities;
|
||||
using TBF.BenchControl.Generic;
|
||||
using TBF.Resources;
|
||||
|
||||
namespace TBF.BenchControl.TestMethods.iPerlCommunication.iPerlHead
|
||||
{
|
||||
public class ProcParams : ProcedureParamsBase, IParamsProvider, IProcedureParams
|
||||
{
|
||||
public MeterType MeterType;
|
||||
public int FactorLimitLo; /// Lower limit for the calibration factor
|
||||
public int FactorLimitHi; /// Upper limit for the calibration factor
|
||||
#if ORACLE_DB
|
||||
public int WMType_ID; /// Required for Oracle DB: ID_WZTyp in table VT_PRUEFPUNKT_SOLL_SD
|
||||
public int WMType_Rev; /// Required for Oracle DB: Rev_WZTyp in table VT_PRUEFPUNKT_SOLL_SD
|
||||
#endif
|
||||
|
||||
|
||||
public override void InitializeAll()
|
||||
{
|
||||
MeterType = MeterType.AutoDetect;
|
||||
FactorLimitLo = 1000;
|
||||
FactorLimitHi = 8000;
|
||||
#if ORACLE_DB
|
||||
WMType_ID = 2; /// Value for iPerl DN15
|
||||
WMType_Rev = 1; /// Value for iPerl DN15
|
||||
#endif
|
||||
}
|
||||
|
||||
string[] paramNames = new string[]
|
||||
{
|
||||
"iPerl type",
|
||||
"Calib. factor Lo",
|
||||
"Calib. factor Hi",
|
||||
#if ORACLE_DB
|
||||
"WMType ID",
|
||||
"WMType Rev.",
|
||||
#endif
|
||||
};
|
||||
public override string ParamName(int i) { return paramNames[i]; }
|
||||
public override int ParamsCount() { return paramNames.Length; }
|
||||
|
||||
public override string ToString(int i)
|
||||
{
|
||||
switch (i)
|
||||
{
|
||||
case 0: return MeterType.ToString();
|
||||
case 1: return FactorLimitLo.ToString();
|
||||
case 2: return FactorLimitHi.ToString();
|
||||
#if ORACLE_DB
|
||||
case 3: return WMType_ID.ToString();
|
||||
case 4: return WMType_Rev.ToString();
|
||||
#endif
|
||||
default: return string.Empty;
|
||||
}
|
||||
}
|
||||
|
||||
public void UpdateParam(int i, string strValue)
|
||||
{
|
||||
switch (i)
|
||||
{
|
||||
case 0:
|
||||
for (MeterType mt = 0; mt < MeterType.Count; mt++)
|
||||
{
|
||||
if (mt.ToString().Equals(strValue)) { MeterType = mt; return; }
|
||||
}
|
||||
break;
|
||||
case 1: FactorLimitLo = int.Parse(strValue); return;
|
||||
case 2: FactorLimitHi = int.Parse(strValue); return;
|
||||
#if ORACLE_DB
|
||||
case 3: WMType_ID = int.Parse(strValue); return;
|
||||
case 4: WMType_Rev = int.Parse(strValue); return;
|
||||
#endif
|
||||
default: return;
|
||||
}
|
||||
}
|
||||
|
||||
public bool ValidateParam(int i, string strValue, out string message)
|
||||
{
|
||||
message = string.Empty;
|
||||
|
||||
int iDummy;
|
||||
|
||||
switch (i)
|
||||
{
|
||||
case 0:
|
||||
for (MeterType mt = 0; mt < MeterType.Count; mt++) if (mt.ToString().Equals(strValue)) return true;
|
||||
break;
|
||||
case 1:
|
||||
case 2:
|
||||
if (int.TryParse(strValue, out iDummy) && iDummy >= 1000 && iDummy <= 8000) return true;
|
||||
break;
|
||||
|
||||
#if ORACLE_DB
|
||||
case 3: /// WMType_ID
|
||||
case 4: /// WMType_Rev
|
||||
if (int.TryParse(strValue, out iDummy)) return true;
|
||||
break;
|
||||
#endif
|
||||
default:
|
||||
message = "Invalid index";
|
||||
return false;
|
||||
}
|
||||
|
||||
message = ParamName(i) + " is invalid";
|
||||
return false;
|
||||
}
|
||||
|
||||
void CopyContentTo(ProcParams prms)
|
||||
{
|
||||
prms.MeterType = this.MeterType;
|
||||
prms.FactorLimitLo = this.FactorLimitLo;
|
||||
prms.FactorLimitHi = this.FactorLimitHi;
|
||||
#if ORACLE_DB
|
||||
prms.WMType_ID = this.WMType_ID;
|
||||
prms.WMType_Rev = this.WMType_Rev;
|
||||
#endif
|
||||
}
|
||||
|
||||
public IParamsProvider Clone()
|
||||
{
|
||||
ProcParams pars = new ProcParams();
|
||||
CopyContentTo(pars);
|
||||
return pars;
|
||||
}
|
||||
|
||||
public override void UpdateProcedureParams(ComponentProcedure dbEntity)
|
||||
{
|
||||
if (dbEntity == null) return;
|
||||
try
|
||||
{
|
||||
ProcParams tmp = (ProcParams)(new XmlSerializer(typeof(ProcParams)))
|
||||
.Deserialize(new StringReader(dbEntity.Parameters));
|
||||
|
||||
procedureParamsEntity = dbEntity;
|
||||
componentName = dbEntity.CmpntName;
|
||||
procedure = dbEntity.Procedure;
|
||||
|
||||
tmp.CopyContentTo(this);
|
||||
}
|
||||
catch
|
||||
{
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
public ProcParams()
|
||||
{
|
||||
}
|
||||
|
||||
public ProcParams(bool initialize)
|
||||
{
|
||||
if (initialize) InitializeAll();
|
||||
}
|
||||
|
||||
public ProcParams(ComponentProcedure procParamsEntity, string componentName, Procedure procedure)
|
||||
{
|
||||
this.procedureParamsEntity = procParamsEntity;
|
||||
this.componentName = componentName;
|
||||
this.procedure = procedure;
|
||||
}
|
||||
}
|
||||
}
|
||||
+160
@@ -0,0 +1,160 @@
|
||||
///
|
||||
/// Copyright (c) 2015-2017 Sensus Metering Systems
|
||||
///
|
||||
using System;
|
||||
|
||||
namespace TBF.BenchControl.TestMethods.iPerlCommunication.iPerlHead
|
||||
{
|
||||
public class StatusStruct
|
||||
{
|
||||
public static readonly int Length = 48;
|
||||
|
||||
public Byte Version;
|
||||
public FlowState FlowState;
|
||||
public UInt32 BillingVolume;
|
||||
public UInt32 ForwardVolume;
|
||||
public UInt32 ReverseVolume;
|
||||
public UInt32 SecondsActive;
|
||||
public UInt32 SecondsIdle;
|
||||
public UInt32 SecondsUsed;
|
||||
public UInt32 UTC;
|
||||
public Int32 ScaledAvgFlowRate;
|
||||
public UInt16 PeakFlowRate;
|
||||
public UInt16 AlarmState;
|
||||
public byte RebootCount;
|
||||
public byte[] AlarmCount;
|
||||
public UInt16 FlipTime;
|
||||
|
||||
|
||||
public StatusStruct()
|
||||
{
|
||||
AlarmCount = new byte[7];
|
||||
}
|
||||
|
||||
public byte[] ToByteArray()
|
||||
{
|
||||
byte[] result = new byte[Length];
|
||||
|
||||
result[0] = Version;
|
||||
result[1] = (byte)FlowState;
|
||||
|
||||
result[2] = (byte)(BillingVolume & 0x000000FF);
|
||||
result[3] = (byte)((BillingVolume >> 8) & 0x000000FF);
|
||||
result[4] = (byte)((BillingVolume >> 16) & 0x000000FF);
|
||||
result[5] = (byte)((BillingVolume >> 24) & 0x000000FF);
|
||||
|
||||
result[6] = (byte)(ForwardVolume & 0x000000FF);
|
||||
result[7] = (byte)((ForwardVolume >> 8) & 0x000000FF);
|
||||
result[8] = (byte)((ForwardVolume >> 16) & 0x000000FF);
|
||||
result[9] = (byte)((ForwardVolume >> 24) & 0x000000FF);
|
||||
|
||||
result[10] = (byte)(ReverseVolume & 0x000000FF);
|
||||
result[11] = (byte)((ReverseVolume >> 8) & 0x000000FF);
|
||||
result[12] = (byte)((ReverseVolume >> 16) & 0x000000FF);
|
||||
result[13] = (byte)((ReverseVolume >> 24) & 0x000000FF);
|
||||
|
||||
result[14] = (byte)(SecondsActive & 0x000000FF);
|
||||
result[15] = (byte)((SecondsActive >> 8) & 0x000000FF);
|
||||
result[16] = (byte)((SecondsActive >> 16) & 0x000000FF);
|
||||
result[17] = (byte)((SecondsActive >> 24) & 0x000000FF);
|
||||
|
||||
result[18] = (byte)(SecondsIdle & 0x000000FF);
|
||||
result[19] = (byte)((SecondsIdle >> 8) & 0x000000FF);
|
||||
result[20] = (byte)((SecondsIdle >> 16) & 0x000000FF);
|
||||
result[21] = (byte)((SecondsIdle >> 24) & 0x000000FF);
|
||||
|
||||
result[22] = (byte)(SecondsUsed & 0x000000FF);
|
||||
result[23] = (byte)((SecondsUsed >> 8) & 0x000000FF);
|
||||
result[24] = (byte)((SecondsUsed >> 16) & 0x000000FF);
|
||||
result[25] = (byte)((SecondsUsed >> 24) & 0x000000FF);
|
||||
|
||||
result[26] = (byte)(UTC & 0x000000FF);
|
||||
result[27] = (byte)((UTC >> 8) & 0x000000FF);
|
||||
result[28] = (byte)((UTC >> 16) & 0x000000FF);
|
||||
result[29] = (byte)((UTC >> 24) & 0x000000FF);
|
||||
|
||||
result[30] = (byte)(ScaledAvgFlowRate & 0x000000FF);
|
||||
result[31] = (byte)((ScaledAvgFlowRate >> 8) & 0x000000FF);
|
||||
result[32] = (byte)((ScaledAvgFlowRate >> 16) & 0x000000FF);
|
||||
result[33] = (byte)((ScaledAvgFlowRate >> 24) & 0x000000FF); /// TODO: test with negative value
|
||||
|
||||
result[34] = (byte)(PeakFlowRate & 0x00FF);
|
||||
result[35] = (byte)((PeakFlowRate >> 8) & 0x00FF);
|
||||
|
||||
result[36] = (byte)(AlarmState & 0x00FF);
|
||||
result[37] = (byte)((AlarmState >> 8) & 0x00FF);
|
||||
|
||||
result[38] = RebootCount;
|
||||
|
||||
result[39] = AlarmCount[0];
|
||||
result[40] = AlarmCount[1];
|
||||
result[41] = AlarmCount[2];
|
||||
result[42] = AlarmCount[3];
|
||||
result[43] = AlarmCount[4];
|
||||
result[44] = AlarmCount[5];
|
||||
result[45] = AlarmCount[6];
|
||||
|
||||
result[46] = (byte)(FlipTime & 0x00FF);
|
||||
result[47] = (byte)((FlipTime >> 8) & 0x00FF);
|
||||
|
||||
return result;
|
||||
}
|
||||
|
||||
public static StatusStruct FromByteArray(byte[] data)
|
||||
{
|
||||
if (data.Length != Length) return null;
|
||||
|
||||
StatusStruct result = new StatusStruct();
|
||||
|
||||
result.Version = data[0];
|
||||
result.FlowState = (FlowState)data[1];
|
||||
result.BillingVolume = (((UInt32)data[5] * 256 + data[4]) * 256 + data[3]) * 256 + data[2];
|
||||
result.ForwardVolume = (((UInt32)data[9] * 256 + data[8]) * 256 + data[7]) * 256 + data[6];
|
||||
result.ReverseVolume = (((UInt32)data[13] * 256 + data[12]) * 256 + data[11]) * 256 + data[10];
|
||||
result.SecondsActive = (((UInt32)data[17] * 256 + data[16]) * 256 + data[15]) * 256 + data[14];
|
||||
result.SecondsIdle = (((UInt32)data[21] * 256 + data[20]) * 256 + data[19]) * 256 + data[18];
|
||||
result.SecondsUsed = (((UInt32)data[25] * 256 + data[24]) * 256 + data[23]) * 256 + data[22];
|
||||
result.UTC = (((UInt32)data[29] * 256 + data[28]) * 256 + data[27]) * 256 + data[26];
|
||||
result.ScaledAvgFlowRate = (((Int32)data[33] * 256 + data[32]) * 256 + data[31]) * 256 + data[30]; /// TODO: test with negative value
|
||||
result.PeakFlowRate = (UInt16)(data[34] + 256 * data[35]);
|
||||
result.AlarmState = (UInt16)(data[36] + 256 * data[37]);
|
||||
result.RebootCount = data[38];
|
||||
result.AlarmCount[0] = data[39];
|
||||
result.AlarmCount[1] = data[40];
|
||||
result.AlarmCount[2] = data[41];
|
||||
result.AlarmCount[3] = data[42];
|
||||
result.AlarmCount[4] = data[43];
|
||||
result.AlarmCount[5] = data[44];
|
||||
result.AlarmCount[6] = data[45];
|
||||
result.FlipTime = (UInt16)(data[46] * 256 + data[47]);
|
||||
|
||||
return result;
|
||||
}
|
||||
|
||||
public override string ToString()
|
||||
{
|
||||
return string.Format("Status: V{0} Flow={1} BillVol={2} ForwVol={3} RevVol={4} SecActive={5}s SecIdle={6}s SecUsed={7}s UTC={8} AvgFlowRate={9} PeekFlowRate={10} AlarmState={11} RebootCount={12} A0={13} A1={14} A2={15} A3={16} A4={17} A5={18} A6={19} FlipTime={20}",
|
||||
Version,
|
||||
FlowState,
|
||||
BillingVolume,
|
||||
ForwardVolume,
|
||||
ReverseVolume,
|
||||
SecondsActive,
|
||||
SecondsIdle,
|
||||
SecondsUsed,
|
||||
UTC,
|
||||
ScaledAvgFlowRate,
|
||||
PeakFlowRate,
|
||||
AlarmState,
|
||||
RebootCount,
|
||||
AlarmCount[0],
|
||||
AlarmCount[1],
|
||||
AlarmCount[2],
|
||||
AlarmCount[3],
|
||||
AlarmCount[4],
|
||||
AlarmCount[5],
|
||||
AlarmCount[6],
|
||||
FlipTime);
|
||||
}
|
||||
}
|
||||
}
|
||||
Reference in New Issue
Block a user