More TankSelector modifications, ver. 2.12.491
This commit is contained in:
@@ -1,37 +1,93 @@
|
|||||||
|
///
|
||||||
|
/// Copyright (c) 2017 Sensus Metering Systems
|
||||||
|
///
|
||||||
namespace TBF.BenchControl.Modbus.TankSelector
|
namespace TBF.BenchControl.Modbus.TankSelector
|
||||||
{
|
{
|
||||||
public class SelectTankOp : IOperation
|
public class SelectTankOp : IOperation
|
||||||
{
|
{
|
||||||
TankSelector tankSelector;
|
TankSelector tankSelector;
|
||||||
int tankNo;
|
TankId tankId;
|
||||||
ushort bitMask;
|
ushort bitMask;
|
||||||
|
ushort unselectBitMask;
|
||||||
bool alreadySet;
|
bool alreadySet;
|
||||||
|
bool unselectedWaitLevel;
|
||||||
|
bool doUnselect;
|
||||||
int time;
|
int time;
|
||||||
|
|
||||||
public SelectTankOp(TankSelector tankSelector, int tankNo)
|
public SelectTankOp(TankSelector tankSelector, TankId tankId)
|
||||||
{
|
{
|
||||||
this.tankSelector = tankSelector;
|
this.tankSelector = tankSelector;
|
||||||
this.tankNo = tankNo;
|
this.tankId = tankId; /// tankId is always TankId.Cold, TankId.Warm or TankId.Hot
|
||||||
this.bitMask = (ushort)((tankNo == 1) ? 1 : ((tankNo == 2) ? 2 : ((tankNo == 3) ? 4 : 0)));
|
this.bitMask = (ushort)((tankId == TankId.Cold) ? QuidoOutputs.SelectColdTank
|
||||||
|
: (tankId == TankId.Warm) ? QuidoOutputs.SelectWarmTank
|
||||||
|
: QuidoOutputs.SelectHotTank);
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
||||||
/// <summary>Start this operation</summary>
|
/// <summary>Start this operation</summary>
|
||||||
public void Start()
|
public void Start()
|
||||||
{
|
{
|
||||||
if (tankSelector.CurrentlySelectedTankValid && (tankNo == tankSelector.CurrentlySelectedTank))
|
if (tankSelector.CurrentActivity == Activity.Selected && tankSelector.CurrentTank == tankId)
|
||||||
{
|
{
|
||||||
alreadySet = true;
|
alreadySet = true; /// Nothing to be done in Run()
|
||||||
|
unselectedWaitLevel = false;
|
||||||
|
doUnselect = false;
|
||||||
}
|
}
|
||||||
else
|
else if (tankSelector.CurrentActivity == Activity.Selected_Waiting1min && tankSelector.CurrentTank == tankId)
|
||||||
{
|
{
|
||||||
tankSelector.CurrentlySelectedTank = tankNo;
|
|
||||||
tankSelector.CurrentlySelectedTankValid = true;
|
|
||||||
alreadySet = false;
|
alreadySet = false;
|
||||||
time = 0;
|
unselectedWaitLevel = false;
|
||||||
|
doUnselect = false;
|
||||||
tankSelector.QuidoRS.SetBit(bitMask);
|
time = 1; /// Skip resetting button bit in Run(), wait 1 min.
|
||||||
}
|
}
|
||||||
|
else if (tankSelector.CurrentActivity == Activity.Idle ||
|
||||||
|
tankSelector.CurrentActivity == Activity.Unknown)
|
||||||
|
{
|
||||||
|
SelectTankFromIdleState();
|
||||||
|
}
|
||||||
|
else if (tankSelector.CurrentActivity == Activity.Unselected_WaitingLevel)
|
||||||
|
{
|
||||||
|
alreadySet = false;
|
||||||
|
unselectedWaitLevel = true;
|
||||||
|
doUnselect = false;
|
||||||
|
}
|
||||||
|
else if (tankSelector.CurrentActivity == Activity.Selected ||
|
||||||
|
tankSelector.CurrentActivity == Activity.Selected_Waiting1min)
|
||||||
|
{
|
||||||
|
///
|
||||||
|
/// it follows that (tankSelector.CurrentTank != tankId) => unselect the tank first
|
||||||
|
///
|
||||||
|
alreadySet = false;
|
||||||
|
unselectedWaitLevel = false;
|
||||||
|
doUnselect = true;
|
||||||
|
|
||||||
|
TankId selectedTankId = tankSelector.CurrentTank;
|
||||||
|
|
||||||
|
unselectBitMask = (ushort)((selectedTankId == TankId.Cold) ? QuidoOutputs.PumpToColdTank
|
||||||
|
: (selectedTankId == TankId.Warm) ? QuidoOutputs.PumpToWarmTank
|
||||||
|
: QuidoOutputs.PumpToHotTank);
|
||||||
|
|
||||||
|
tankSelector.State = (selectedTankId == TankId.Cold) ? State.ColdTankUnselected_WaitingLevel
|
||||||
|
: (selectedTankId == TankId.Warm) ? State.WarmTankUnselected_WaitingLevel
|
||||||
|
: State.HotTankUnselected_WaitingLevel;
|
||||||
|
|
||||||
|
tankSelector.ResetBit(unselectBitMask);
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
void SelectTankFromIdleState()
|
||||||
|
{
|
||||||
|
/// tankId is always TankId.Cold, TankId.Warm or TankId.Hot
|
||||||
|
tankSelector.State = (tankId == TankId.Cold) ? State.ColdTankSelected_Waiting1min
|
||||||
|
: (tankId == TankId.Warm) ? State.WarmTankSelected_Waiting1min
|
||||||
|
: State.HotTankSelected_Waiting1min;
|
||||||
|
|
||||||
|
alreadySet = false;
|
||||||
|
unselectedWaitLevel = false;
|
||||||
|
doUnselect = false;
|
||||||
|
time = 0; /// Reset button bit in Run(), wait 1 min.
|
||||||
|
|
||||||
|
tankSelector.SetBit(bitMask);
|
||||||
}
|
}
|
||||||
|
|
||||||
/// <summary>Run this operation</summary>
|
/// <summary>Run this operation</summary>
|
||||||
@@ -41,9 +97,24 @@ namespace TBF.BenchControl.Modbus.TankSelector
|
|||||||
{
|
{
|
||||||
return Event.ConditionMet;
|
return Event.ConditionMet;
|
||||||
}
|
}
|
||||||
|
else if (doUnselect)
|
||||||
|
{
|
||||||
|
tankSelector.ResetBit(unselectBitMask);
|
||||||
|
doUnselect = false;
|
||||||
|
unselectedWaitLevel = true;
|
||||||
|
return Event.ConditionNotMet;
|
||||||
|
}
|
||||||
|
else if (unselectedWaitLevel)
|
||||||
|
{
|
||||||
|
if (tankSelector.CurrentActivity == Activity.Idle)
|
||||||
|
{
|
||||||
|
SelectTankFromIdleState();
|
||||||
|
}
|
||||||
|
return Event.ConditionNotMet;
|
||||||
|
}
|
||||||
else if (time == 0)
|
else if (time == 0)
|
||||||
{
|
{
|
||||||
tankSelector.QuidoRS.ResetBit(bitMask);
|
tankSelector.ResetBit(bitMask);
|
||||||
time++;
|
time++;
|
||||||
return Event.ConditionNotMet;
|
return Event.ConditionNotMet;
|
||||||
}
|
}
|
||||||
|
|||||||
@@ -16,7 +16,7 @@ namespace TBF.BenchControl.Modbus.TankSelector
|
|||||||
readonly Event eventDone;
|
readonly Event eventDone;
|
||||||
|
|
||||||
|
|
||||||
public SetQuidoBitOp(TBF.BenchControl.Modbus.QuidoRS.QuidoRS quidoRS, TankSelector.QuidoOutputs bitMask, bool set)
|
public SetQuidoBitOp(TBF.BenchControl.Modbus.QuidoRS.QuidoRS quidoRS, QuidoOutputs bitMask, bool set)
|
||||||
: this(quidoRS, (ushort)bitMask, set, Event.ConditionMet)
|
: this(quidoRS, (ushort)bitMask, set, Event.ConditionMet)
|
||||||
{
|
{
|
||||||
}
|
}
|
||||||
|
|||||||
@@ -11,6 +11,60 @@ using TBF.Resources;
|
|||||||
|
|
||||||
namespace TBF.BenchControl.Modbus.TankSelector
|
namespace TBF.BenchControl.Modbus.TankSelector
|
||||||
{
|
{
|
||||||
|
/// <summary> Enumeration of water tanks </summary>
|
||||||
|
public enum TankId
|
||||||
|
{
|
||||||
|
None,
|
||||||
|
Cold,
|
||||||
|
Warm,
|
||||||
|
Hot,
|
||||||
|
}
|
||||||
|
|
||||||
|
/// <summary> Enumeration of water tanks activities</summary>
|
||||||
|
public enum Activity
|
||||||
|
{
|
||||||
|
Unknown,
|
||||||
|
Idle,
|
||||||
|
Selected_Waiting1min,
|
||||||
|
Selected,
|
||||||
|
Unselected_WaitingLevel,
|
||||||
|
}
|
||||||
|
|
||||||
|
/// <summary> TankSelector state </summary>
|
||||||
|
public enum State
|
||||||
|
{
|
||||||
|
Unknown, /// Initial state after program startup
|
||||||
|
NoTankSelected,
|
||||||
|
ColdTankSelected_Waiting1min,
|
||||||
|
ColdTankSelected,
|
||||||
|
ColdTankUnselected_WaitingLevel,
|
||||||
|
WarmTankSelected_Waiting1min,
|
||||||
|
WarmTankSelected,
|
||||||
|
WarmTankUnselected_WaitingLevel,
|
||||||
|
HotTankSelected_Waiting1min,
|
||||||
|
HotTankSelected,
|
||||||
|
HotTankUnselected_WaitingLevel,
|
||||||
|
}
|
||||||
|
|
||||||
|
/// <summary> Quido digital out board outputs assignment </summary>
|
||||||
|
public enum QuidoOutputs : ushort
|
||||||
|
{
|
||||||
|
None = 0,
|
||||||
|
SelectColdTank = 0x0001, /// Quido out 1
|
||||||
|
SelectWarmTank = 0x0002, /// Quido out 2
|
||||||
|
SelectHotTank = 0x0004, /// Quido out 3
|
||||||
|
PumpToColdTank = 0x0008, /// Quido out 4
|
||||||
|
PumpToWarmTank = 0x0010, /// Quido out 5
|
||||||
|
PumpToHotTank = 0x0020, /// Quido out 6
|
||||||
|
Mixing = 0x0040, /// Quido out 7
|
||||||
|
HeatingHotTank = 0x0080, /// Quido out 8
|
||||||
|
HeatingWarmTank = 0x0100, /// Quido out 9
|
||||||
|
CoolingHotTank = 0x0200, /// Quido out 10
|
||||||
|
CoolingWarmTank = 0x0400, /// Quido out 11
|
||||||
|
CoolingColdTank = 0x0800, /// Quido out 12
|
||||||
|
}
|
||||||
|
|
||||||
|
|
||||||
public class TankSelector : ComponentBase, ISequenceCondition, IDevice
|
public class TankSelector : ComponentBase, ISequenceCondition, IDevice
|
||||||
{
|
{
|
||||||
private static readonly ILog log = LogManager.GetLogger(typeof(TankSelector));
|
private static readonly ILog log = LogManager.GetLogger(typeof(TankSelector));
|
||||||
@@ -18,7 +72,7 @@ namespace TBF.BenchControl.Modbus.TankSelector
|
|||||||
|
|
||||||
readonly TankSelectorCfg tankSelectorCfg;
|
readonly TankSelectorCfg tankSelectorCfg;
|
||||||
|
|
||||||
public readonly TBF.BenchControl.Modbus.QuidoRS.QuidoRS QuidoRS;
|
readonly TBF.BenchControl.Modbus.QuidoRS.QuidoRS quidoRS;
|
||||||
|
|
||||||
readonly TBF.BenchControl.Modbus.Easytherm.Easytherm hotHeating;
|
readonly TBF.BenchControl.Modbus.Easytherm.Easytherm hotHeating;
|
||||||
readonly TBF.BenchControl.Modbus.Easytherm.Easytherm hotCooling;
|
readonly TBF.BenchControl.Modbus.Easytherm.Easytherm hotCooling;
|
||||||
@@ -27,31 +81,60 @@ namespace TBF.BenchControl.Modbus.TankSelector
|
|||||||
readonly TBF.BenchControl.Modbus.Easytherm.Easytherm coldCooling;
|
readonly TBF.BenchControl.Modbus.Easytherm.Easytherm coldCooling;
|
||||||
|
|
||||||
|
|
||||||
IList<string> sequenceConditionNames;
|
public State State;
|
||||||
IList<IOperation> sequenceConditions;
|
public TankId CurrentTank { get { return GetTankIdFromState(State); } }
|
||||||
|
public Activity CurrentActivity { get { return GetActivityFromState(State); } }
|
||||||
|
|
||||||
|
|
||||||
public int CurrentlySelectedTank;
|
public TankId GetTankIdFromState(State state)
|
||||||
public bool CurrentlySelectedTankValid;
|
|
||||||
|
|
||||||
/// <summary>
|
|
||||||
/// Quido digital out board outputs assignment
|
|
||||||
/// </summary>
|
|
||||||
public enum QuidoOutputs : ushort
|
|
||||||
{
|
{
|
||||||
None = 0,
|
switch (state)
|
||||||
SelectColdTank = 0x0001,
|
{
|
||||||
SelectWarmTank = 0x0002,
|
case State.ColdTankSelected_Waiting1min:
|
||||||
SelectHotTank = 0x0004,
|
case State.ColdTankSelected:
|
||||||
PumpToColdTank = 0x0008,
|
case State.ColdTankUnselected_WaitingLevel:
|
||||||
PumpToWarmTank = 0x0010,
|
return TankId.Cold;
|
||||||
PumpToHotTank = 0x0020,
|
|
||||||
Mixing = 0x0040,
|
case State.WarmTankSelected_Waiting1min:
|
||||||
HeatingHotTank = 0x0080,
|
case State.WarmTankSelected:
|
||||||
HeatingWarmTank = 0x0100,
|
case State.WarmTankUnselected_WaitingLevel:
|
||||||
CoolingHotTank = 0x0200,
|
return TankId.Warm;
|
||||||
CoolingWarmTank = 0x0400,
|
|
||||||
CoolingColdTank = 0x0800,
|
case State.HotTankSelected_Waiting1min:
|
||||||
|
case State.HotTankSelected:
|
||||||
|
case State.HotTankUnselected_WaitingLevel:
|
||||||
|
return TankId.Hot;
|
||||||
|
|
||||||
|
default:
|
||||||
|
return TankId.None;
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
public Activity GetActivityFromState(State state)
|
||||||
|
{
|
||||||
|
switch (state)
|
||||||
|
{
|
||||||
|
case State.NoTankSelected:
|
||||||
|
return Activity.Idle;
|
||||||
|
|
||||||
|
case State.ColdTankSelected_Waiting1min:
|
||||||
|
case State.WarmTankSelected_Waiting1min:
|
||||||
|
case State.HotTankSelected_Waiting1min:
|
||||||
|
return Activity.Selected_Waiting1min;
|
||||||
|
|
||||||
|
case State.ColdTankSelected:
|
||||||
|
case State.WarmTankSelected:
|
||||||
|
case State.HotTankSelected:
|
||||||
|
return Activity.Selected;
|
||||||
|
|
||||||
|
case State.ColdTankUnselected_WaitingLevel:
|
||||||
|
case State.WarmTankUnselected_WaitingLevel:
|
||||||
|
case State.HotTankUnselected_WaitingLevel:
|
||||||
|
return Activity.Unselected_WaitingLevel;
|
||||||
|
|
||||||
|
default:
|
||||||
|
return Activity.Unknown;
|
||||||
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
||||||
@@ -65,8 +148,8 @@ namespace TBF.BenchControl.Modbus.TankSelector
|
|||||||
{
|
{
|
||||||
tankSelectorCfg = cfg as TankSelectorCfg;
|
tankSelectorCfg = cfg as TankSelectorCfg;
|
||||||
|
|
||||||
QuidoRS = (TBF.BenchControl.Modbus.QuidoRS.QuidoRS)TbfComponents.FindComponent(cfg.ParentName, components);
|
quidoRS = (TBF.BenchControl.Modbus.QuidoRS.QuidoRS)TbfComponents.FindComponent(cfg.ParentName, components);
|
||||||
if (QuidoRS == null) throw new Exception(string.Format("Cannot find parent '{0}' of the component {1}", cfg.ParentName, Name));
|
if (quidoRS == null) throw new Exception(string.Format("Cannot find parent '{0}' of the component {1}", cfg.ParentName, Name));
|
||||||
|
|
||||||
hotHeating = (TBF.BenchControl.Modbus.Easytherm.Easytherm)TbfComponents.FindComponent(tankSelectorCfg.HotWaterHeating, components);
|
hotHeating = (TBF.BenchControl.Modbus.Easytherm.Easytherm)TbfComponents.FindComponent(tankSelectorCfg.HotWaterHeating, components);
|
||||||
hotCooling = (TBF.BenchControl.Modbus.Easytherm.Easytherm)TbfComponents.FindComponent(tankSelectorCfg.HotWaterCooling, components);
|
hotCooling = (TBF.BenchControl.Modbus.Easytherm.Easytherm)TbfComponents.FindComponent(tankSelectorCfg.HotWaterCooling, components);
|
||||||
@@ -82,113 +165,48 @@ namespace TBF.BenchControl.Modbus.TankSelector
|
|||||||
|
|
||||||
CreateConditions(true);
|
CreateConditions(true);
|
||||||
|
|
||||||
CurrentlySelectedTankValid = false;
|
State = State.Unknown;
|
||||||
|
|
||||||
log.Debug(this.ToString());
|
log.Debug(this.ToString());
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
///
|
||||||
|
/// IDevice interface implementation
|
||||||
|
///
|
||||||
public void Initialize()
|
public void Initialize()
|
||||||
{
|
{
|
||||||
SetOutputs(0);
|
SetOutputs(0);
|
||||||
}
|
}
|
||||||
public void RunDeviceBefore() {}
|
|
||||||
|
public void RunDeviceBefore()
|
||||||
|
{
|
||||||
|
}
|
||||||
|
|
||||||
public void RunDeviceAfter() {}
|
public void RunDeviceAfter() {}
|
||||||
public void StopDevice() {}
|
public void StopDevice() {}
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
///
|
||||||
void CreateConditions(bool createAll)
|
/// Quido wrappers
|
||||||
{
|
///
|
||||||
sequenceConditionNames = new List<string>();
|
public void SetOutputs(ushort outputs) { quidoRS.SetOutputs(outputs); }
|
||||||
sequenceConditions = new List<IOperation>();
|
public void SetBit(ushort bitMask) { quidoRS.SetBit(bitMask); }
|
||||||
|
public void ResetBit(ushort bitMask) { quidoRS.ResetBit(bitMask); }
|
||||||
sequenceConditionNames.Add(Strings.Select_COLD_tank);
|
|
||||||
if (createAll) sequenceConditions.Add(new SelectTankOp(this, 1));
|
|
||||||
|
|
||||||
sequenceConditionNames.Add(Strings.Select_WARM_tank);
|
|
||||||
if (createAll) sequenceConditions.Add(new SelectTankOp(this, 2));
|
|
||||||
|
|
||||||
sequenceConditionNames.Add(Strings.Select_HOT_tank);
|
|
||||||
if (createAll) sequenceConditions.Add(new SelectTankOp(this, 3));
|
|
||||||
|
|
||||||
sequenceConditionNames.Add(Strings.Unselect_COLD_tank);
|
|
||||||
if (createAll) sequenceConditions.Add(new UnselectTankOp(this, 1));
|
|
||||||
|
|
||||||
sequenceConditionNames.Add(Strings.Unselect_WARM_tank);
|
|
||||||
if (createAll) sequenceConditions.Add(new UnselectTankOp(this, 2));
|
|
||||||
|
|
||||||
sequenceConditionNames.Add(Strings.Unselect_HOT_tank);
|
|
||||||
if (createAll) sequenceConditions.Add(new UnselectTankOp(this, 3));
|
|
||||||
|
|
||||||
sequenceConditionNames.Add(Strings.Set_hot_water_heating_temperature);
|
|
||||||
if (createAll) sequenceConditions.Add(hotHeating.SetRequiredTemperatureOp());
|
|
||||||
|
|
||||||
sequenceConditionNames.Add(Strings.Set_hot_water_cooling_temperature);
|
|
||||||
if (createAll) sequenceConditions.Add(hotCooling.SetRequiredTemperatureOp());
|
|
||||||
|
|
||||||
sequenceConditionNames.Add(Strings.Set_warm_water_heating_temperature);
|
|
||||||
if (createAll) sequenceConditions.Add(warmHeating.SetRequiredTemperatureOp());
|
|
||||||
|
|
||||||
sequenceConditionNames.Add(Strings.Set_warm_water_cooling_temperature);
|
|
||||||
if (createAll) sequenceConditions.Add(warmCooling.SetRequiredTemperatureOp());
|
|
||||||
|
|
||||||
sequenceConditionNames.Add(Strings.Set_cold_water_cooling_temperature);
|
|
||||||
if (createAll) sequenceConditions.Add(coldCooling.SetRequiredTemperatureOp());
|
|
||||||
|
|
||||||
sequenceConditionNames.Add("Start heating hot water");
|
|
||||||
if (createAll) sequenceConditions.Add(new SetQuidoBitOp(QuidoRS, QuidoOutputs.HeatingHotTank, true));
|
|
||||||
|
|
||||||
sequenceConditionNames.Add("Stop heating hot water");
|
|
||||||
if (createAll) sequenceConditions.Add(new SetQuidoBitOp(QuidoRS, QuidoOutputs.HeatingHotTank, false));
|
|
||||||
|
|
||||||
sequenceConditionNames.Add("Start cooling hot water");
|
|
||||||
if (createAll) sequenceConditions.Add(new SetQuidoBitOp(QuidoRS, QuidoOutputs.CoolingHotTank, true));
|
|
||||||
|
|
||||||
sequenceConditionNames.Add("Stop cooling hot water");
|
|
||||||
if (createAll) sequenceConditions.Add(new SetQuidoBitOp(QuidoRS, QuidoOutputs.CoolingHotTank, false));
|
|
||||||
|
|
||||||
sequenceConditionNames.Add("Start heating warm water");
|
|
||||||
if (createAll) sequenceConditions.Add(new SetQuidoBitOp(QuidoRS, QuidoOutputs.HeatingWarmTank, true));
|
|
||||||
|
|
||||||
sequenceConditionNames.Add("Stop heating warm water");
|
|
||||||
if (createAll) sequenceConditions.Add(new SetQuidoBitOp(QuidoRS, QuidoOutputs.HeatingWarmTank, false));
|
|
||||||
|
|
||||||
sequenceConditionNames.Add("Start cooling warm water");
|
|
||||||
if (createAll) sequenceConditions.Add(new SetQuidoBitOp(QuidoRS, QuidoOutputs.CoolingWarmTank, true));
|
|
||||||
|
|
||||||
sequenceConditionNames.Add("Stop cooling warm water");
|
|
||||||
if (createAll) sequenceConditions.Add(new SetQuidoBitOp(QuidoRS, QuidoOutputs.CoolingWarmTank, false));
|
|
||||||
|
|
||||||
sequenceConditionNames.Add("Start cooling cold water");
|
|
||||||
if (createAll) sequenceConditions.Add(new SetQuidoBitOp(QuidoRS, QuidoOutputs.CoolingColdTank, true));
|
|
||||||
|
|
||||||
sequenceConditionNames.Add("Stop cooling cold water");
|
|
||||||
if (createAll) sequenceConditions.Add(new SetQuidoBitOp(QuidoRS, QuidoOutputs.CoolingColdTank, false));
|
|
||||||
|
|
||||||
sequenceConditionNames.Add("Start mixing water");
|
|
||||||
if (createAll) sequenceConditions.Add(new SetQuidoBitOp(QuidoRS, QuidoOutputs.Mixing, true));
|
|
||||||
|
|
||||||
sequenceConditionNames.Add("Stop mixing water");
|
|
||||||
if (createAll) sequenceConditions.Add(new SetQuidoBitOp(QuidoRS, QuidoOutputs.Mixing, false));
|
|
||||||
}
|
|
||||||
|
|
||||||
|
|
||||||
/// <summary>
|
|
||||||
/// Set outputs of QuidoRS board
|
|
||||||
/// </summary>
|
|
||||||
/// <param name="outputs">output value</param>
|
|
||||||
public void SetOutputs(uint outputs)
|
|
||||||
{
|
|
||||||
QuidoRS.SetOutputs((ushort)outputs);
|
|
||||||
}
|
|
||||||
|
|
||||||
|
///
|
||||||
|
/// ISequenceCondition interface implementation (conditions in transition sequences)
|
||||||
|
///
|
||||||
|
IList<string> sequenceConditionNames;
|
||||||
|
IList<IOperation> sequenceConditions;
|
||||||
|
|
||||||
public int ConditionsCount { get { return sequenceConditions != null ? sequenceConditions.Count : 0; } }
|
public int ConditionsCount { get { return sequenceConditions != null ? sequenceConditions.Count : 0; } }
|
||||||
|
|
||||||
|
/// Strings are added to the combo-box for transition sequence condition selection
|
||||||
/// Returned strings are added to the combo-box
|
|
||||||
public string ConditionName(int i)
|
public string ConditionName(int i)
|
||||||
{
|
{
|
||||||
if (sequenceConditionNames != null && i < sequenceConditionNames.Count && i >= 0)
|
if (sequenceConditionNames != null && i < sequenceConditionNames.Count && i >= 0)
|
||||||
@@ -201,6 +219,7 @@ namespace TBF.BenchControl.Modbus.TankSelector
|
|||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
/// Operations are executed as a part of a transition sequence
|
||||||
public IOperation ConditionOp(int i)
|
public IOperation ConditionOp(int i)
|
||||||
{
|
{
|
||||||
if (sequenceConditions != null && i < sequenceConditions.Count && i >= 0)
|
if (sequenceConditions != null && i < sequenceConditions.Count && i >= 0)
|
||||||
@@ -212,5 +231,47 @@ namespace TBF.BenchControl.Modbus.TankSelector
|
|||||||
return null;
|
return null;
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
void ClearConditions()
|
||||||
|
{
|
||||||
|
sequenceConditionNames = new List<string>();
|
||||||
|
sequenceConditions = new List<IOperation>();
|
||||||
|
}
|
||||||
|
|
||||||
|
void AddCondition(string conditionName, bool createOperation, IOperation conditionOperation)
|
||||||
|
{
|
||||||
|
sequenceConditionNames.Add(conditionName);
|
||||||
|
if (createOperation) sequenceConditions.Add(conditionOperation);
|
||||||
|
}
|
||||||
|
|
||||||
|
/// <summary>
|
||||||
|
/// Create a list of conditions
|
||||||
|
/// </summary>
|
||||||
|
/// <param name="createOps">true = create names and condition operations, false = create names only</param>
|
||||||
|
void CreateConditions(bool createOps)
|
||||||
|
{
|
||||||
|
ClearConditions();
|
||||||
|
AddCondition(Strings.Select_COLD_tank, createOps, new SelectTankOp(this, TankId.Cold));
|
||||||
|
AddCondition(Strings.Select_WARM_tank, createOps, new SelectTankOp(this, TankId.Warm));
|
||||||
|
AddCondition(Strings.Select_HOT_tank, createOps, new SelectTankOp(this, TankId.Hot));
|
||||||
|
AddCondition(Strings.Unselect_current_tank, createOps, new UnselectTankOp(this));
|
||||||
|
AddCondition(Strings.Set_hot_water_heating_temperature, createOps, hotHeating.SetRequiredTemperatureOp());
|
||||||
|
AddCondition(Strings.Set_hot_water_cooling_temperature, createOps, hotCooling.SetRequiredTemperatureOp());
|
||||||
|
AddCondition(Strings.Set_warm_water_heating_temperature, createOps, warmHeating.SetRequiredTemperatureOp());
|
||||||
|
AddCondition(Strings.Set_warm_water_cooling_temperature, createOps, warmCooling.SetRequiredTemperatureOp());
|
||||||
|
AddCondition(Strings.Set_cold_water_cooling_temperature, createOps, coldCooling.SetRequiredTemperatureOp());
|
||||||
|
AddCondition("Start heating hot water", createOps, new SetQuidoBitOp(quidoRS, QuidoOutputs.HeatingHotTank, true));
|
||||||
|
AddCondition("Stop heating hot water", createOps, new SetQuidoBitOp(quidoRS, QuidoOutputs.HeatingHotTank, false));
|
||||||
|
AddCondition("Start cooling hot water", createOps, new SetQuidoBitOp(quidoRS, QuidoOutputs.CoolingHotTank, true));
|
||||||
|
AddCondition("Stop cooling hot water", createOps, new SetQuidoBitOp(quidoRS, QuidoOutputs.CoolingHotTank, false));
|
||||||
|
AddCondition("Start heating warm water", createOps, new SetQuidoBitOp(quidoRS, QuidoOutputs.HeatingWarmTank, true));
|
||||||
|
AddCondition("Stop heating warm water", createOps, new SetQuidoBitOp(quidoRS, QuidoOutputs.HeatingWarmTank, false));
|
||||||
|
AddCondition("Start cooling warm water", createOps, new SetQuidoBitOp(quidoRS, QuidoOutputs.CoolingWarmTank, true));
|
||||||
|
AddCondition("Stop cooling warm water", createOps, new SetQuidoBitOp(quidoRS, QuidoOutputs.CoolingWarmTank, false));
|
||||||
|
AddCondition("Start cooling cold water", createOps, new SetQuidoBitOp(quidoRS, QuidoOutputs.CoolingColdTank, true));
|
||||||
|
AddCondition("Stop cooling cold water", createOps, new SetQuidoBitOp(quidoRS, QuidoOutputs.CoolingColdTank, false));
|
||||||
|
AddCondition("Start mixing water", createOps, new SetQuidoBitOp(quidoRS, QuidoOutputs.Mixing, true));
|
||||||
|
AddCondition("Stop mixing water", createOps, new SetQuidoBitOp(quidoRS, QuidoOutputs.Mixing, false));
|
||||||
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
@@ -1,55 +1,68 @@
|
|||||||
|
///
|
||||||
|
/// Copyright (c) 2017 Sensus Metering Systems
|
||||||
|
///
|
||||||
namespace TBF.BenchControl.Modbus.TankSelector
|
namespace TBF.BenchControl.Modbus.TankSelector
|
||||||
{
|
{
|
||||||
public class UnselectTankOp : IOperation
|
public class UnselectTankOp : IOperation
|
||||||
{
|
{
|
||||||
TankSelector tankSelector;
|
TankSelector tankSelector;
|
||||||
int tankNo;
|
TankId tankId;
|
||||||
ushort bitMask;
|
ushort unselectBitMask;
|
||||||
bool alreadyUnselected;
|
bool doUnselect;
|
||||||
|
bool unselectedWaitLevel;
|
||||||
int time;
|
int time;
|
||||||
|
|
||||||
public UnselectTankOp(TankSelector tankSelector, int tankNo)
|
public UnselectTankOp(TankSelector tankSelector)
|
||||||
{
|
{
|
||||||
this.tankSelector = tankSelector;
|
this.tankSelector = tankSelector;
|
||||||
this.tankNo = tankNo;
|
|
||||||
this.bitMask = (ushort)((tankNo == 1) ? 8 : ((tankNo == 2) ? 0x10 : ((tankNo == 3) ? 0x20 : 0)));
|
|
||||||
}
|
}
|
||||||
|
|
||||||
/// <summary>Start this operation</summary>
|
/// <summary>Start this operation</summary>
|
||||||
public void Start()
|
public void Start()
|
||||||
{
|
{
|
||||||
if (tankSelector.CurrentlySelectedTankValid && (tankNo == 0))
|
if (tankSelector.CurrentActivity == Activity.Selected ||
|
||||||
|
tankSelector.CurrentActivity == Activity.Selected_Waiting1min)
|
||||||
{
|
{
|
||||||
alreadyUnselected = true;
|
tankId = tankSelector.CurrentTank;
|
||||||
}
|
unselectBitMask = (ushort)((tankId == TankId.Cold) ? QuidoOutputs.PumpToColdTank
|
||||||
else
|
: (tankId == TankId.Warm) ? QuidoOutputs.PumpToWarmTank
|
||||||
{
|
: QuidoOutputs.PumpToHotTank);
|
||||||
tankSelector.CurrentlySelectedTank = tankNo;
|
doUnselect = true;
|
||||||
tankSelector.CurrentlySelectedTankValid = true;
|
unselectedWaitLevel = false;
|
||||||
alreadyUnselected = false;
|
|
||||||
time = 0;
|
|
||||||
|
|
||||||
tankSelector.QuidoRS.SetBit(bitMask);
|
tankSelector.SetBit(unselectBitMask);
|
||||||
|
}
|
||||||
|
else if (tankSelector.CurrentActivity == Activity.Unselected_WaitingLevel)
|
||||||
|
{
|
||||||
|
tankId = tankSelector.CurrentTank;
|
||||||
|
|
||||||
|
doUnselect = false;
|
||||||
|
unselectedWaitLevel = true;
|
||||||
|
}
|
||||||
|
else /// tankSelector.CurrentActivity == Activity.Idle or Activity.Uknown
|
||||||
|
{
|
||||||
|
doUnselect = false;
|
||||||
|
unselectedWaitLevel = false;
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
/// <summary>Run this operation</summary>
|
/// <summary>Run this operation</summary>
|
||||||
public Event Run()
|
public Event Run()
|
||||||
{
|
{
|
||||||
if (alreadyUnselected)
|
if (doUnselect)
|
||||||
{
|
{
|
||||||
return Event.ConditionMet;
|
tankSelector.ResetBit(unselectBitMask);
|
||||||
}
|
doUnselect = false;
|
||||||
else if (time == 0)
|
unselectedWaitLevel = true;
|
||||||
{
|
|
||||||
tankSelector.QuidoRS.ResetBit(bitMask);
|
|
||||||
time++;
|
|
||||||
return Event.ConditionNotMet;
|
return Event.ConditionNotMet;
|
||||||
}
|
}
|
||||||
else if (time <= 60)
|
else if (unselectedWaitLevel)
|
||||||
{
|
{
|
||||||
time++;
|
if (tankSelector.CurrentActivity == Activity.Idle)
|
||||||
|
{
|
||||||
|
unselectedWaitLevel = false;
|
||||||
|
return Event.ConditionMet;
|
||||||
|
}
|
||||||
return Event.ConditionNotMet;
|
return Event.ConditionNotMet;
|
||||||
}
|
}
|
||||||
else
|
else
|
||||||
|
|||||||
@@ -1,5 +1,5 @@
|
|||||||
///
|
///
|
||||||
/// Copyright (c) 2013-2015 Sensus Metering Systems
|
/// Copyright (c) 2013-2017 Sensus Metering Systems
|
||||||
///
|
///
|
||||||
using System;
|
using System;
|
||||||
using System.Collections.Generic;
|
using System.Collections.Generic;
|
||||||
|
|||||||
@@ -29,5 +29,5 @@ using System.Runtime.InteropServices;
|
|||||||
// Build Number
|
// Build Number
|
||||||
// Revision
|
// Revision
|
||||||
//
|
//
|
||||||
[assembly: AssemblyVersion("2.12.490.1")]
|
[assembly: AssemblyVersion("2.12.491.1")]
|
||||||
[assembly: AssemblyFileVersion("2.12.490.1")]
|
[assembly: AssemblyFileVersion("2.12.491.1")]
|
||||||
|
|||||||
+3
-21
@@ -4447,29 +4447,11 @@ namespace TBF.Resources {
|
|||||||
}
|
}
|
||||||
|
|
||||||
/// <summary>
|
/// <summary>
|
||||||
/// Looks up a localized string similar to Unselect COLD water.
|
/// Looks up a localized string similar to Unselect current tank.
|
||||||
/// </summary>
|
/// </summary>
|
||||||
internal static string Unselect_COLD_tank {
|
internal static string Unselect_current_tank {
|
||||||
get {
|
get {
|
||||||
return ResourceManager.GetString("Unselect_COLD_tank", resourceCulture);
|
return ResourceManager.GetString("Unselect_current_tank", resourceCulture);
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
/// <summary>
|
|
||||||
/// Looks up a localized string similar to Unselect HOT water.
|
|
||||||
/// </summary>
|
|
||||||
internal static string Unselect_HOT_tank {
|
|
||||||
get {
|
|
||||||
return ResourceManager.GetString("Unselect_HOT_tank", resourceCulture);
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
/// <summary>
|
|
||||||
/// Looks up a localized string similar to Unselect WARM water.
|
|
||||||
/// </summary>
|
|
||||||
internal static string Unselect_WARM_tank {
|
|
||||||
get {
|
|
||||||
return ResourceManager.GetString("Unselect_WARM_tank", resourceCulture);
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|||||||
@@ -1642,14 +1642,8 @@
|
|||||||
<data name="Select_WARM_tank" xml:space="preserve">
|
<data name="Select_WARM_tank" xml:space="preserve">
|
||||||
<value>Select WARM water</value>
|
<value>Select WARM water</value>
|
||||||
</data>
|
</data>
|
||||||
<data name="Unselect_COLD_tank" xml:space="preserve">
|
<data name="Unselect_current_tank" xml:space="preserve">
|
||||||
<value>Unselect COLD water</value>
|
<value>Unselect current tank</value>
|
||||||
</data>
|
|
||||||
<data name="Unselect_HOT_tank" xml:space="preserve">
|
|
||||||
<value>Unselect HOT water</value>
|
|
||||||
</data>
|
|
||||||
<data name="Unselect_WARM_tank" xml:space="preserve">
|
|
||||||
<value>Unselect WARM water</value>
|
|
||||||
</data>
|
</data>
|
||||||
<data name="T_cold_cooling" xml:space="preserve">
|
<data name="T_cold_cooling" xml:space="preserve">
|
||||||
<value>T cold cooling</value>
|
<value>T cold cooling</value>
|
||||||
|
|||||||
Reference in New Issue