Bug fix for the case of combined WM test and odd total nr. of watermeters (Munich)
This commit is contained in:
@@ -261,7 +261,7 @@ namespace TBF.BenchControl.TestMethods.CombinedMeters
|
||||
|
||||
string logstr = string.Format("E={0} f={1} q={2}", cBrd.EtPulses(0), cBrd.ReferenceFreq,
|
||||
cBrd.ReferenceFlow * outPath.FlowMeter.NominalFlow);
|
||||
for (int i = 0; i < Program.WMsCount; i++)
|
||||
for (int i = 0; i < (Program.WMsCount / 2) * 2; i++)
|
||||
{
|
||||
logstr += string.Format(" M{0}=({1},{2})", i + 1, WMRefPulses[i], WMPulses[i]);
|
||||
}
|
||||
|
||||
Reference in New Issue