Bugs in sequences fixed: Missing CheckUiOp
This commit is contained in:
@@ -16,8 +16,9 @@ namespace TBF.BenchControl.TestMethods.CameraRoiDetection
|
|||||||
{
|
{
|
||||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||||
|
|
||||||
IList<Event> e; /// Events from currently running operations
|
IList<Event> e = new List<Event>(); /// Events from currently running operations
|
||||||
Event retVal = Event.Done;
|
Event retVal = Event.Done;
|
||||||
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
|
|
||||||
processDataLoggingOp = null;
|
processDataLoggingOp = null;
|
||||||
|
|
||||||
|
|||||||
@@ -30,8 +30,9 @@ namespace TBF.BenchControl.TestMethods.CombinedMeters
|
|||||||
/// Specific for combined meters
|
/// Specific for combined meters
|
||||||
int[] lastWMPulses = new int[Program.WMsCount];
|
int[] lastWMPulses = new int[Program.WMsCount];
|
||||||
|
|
||||||
IList<Event> e; /// Events from currently running operations
|
IList<Event> e = new List<Event>(); /// Events from currently running operations
|
||||||
Event retVal = Event.Done;
|
Event retVal = Event.Done;
|
||||||
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
|
|
||||||
ltrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
ltrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
||||||
|
|
||||||
|
|||||||
+3
-1
@@ -22,7 +22,9 @@ namespace TBF.BenchControl.TestMethods.CombinedWithDetection
|
|||||||
/// Specific for combined meters
|
/// Specific for combined meters
|
||||||
int[] lastWMPulses = new int[Program.WMsCount];
|
int[] lastWMPulses = new int[Program.WMsCount];
|
||||||
|
|
||||||
IList<Event> e; /// Events from currently running operations
|
IList<Event> e = new List<Event>(); /// Events from currently running operations
|
||||||
|
Event retVal = Event.Done;
|
||||||
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
|
|
||||||
//--------------------------------
|
//--------------------------------
|
||||||
State.Create("CombinedWithDetection : stop diverter gate etc")
|
State.Create("CombinedWithDetection : stop diverter gate etc")
|
||||||
|
|||||||
+3
-5
@@ -27,11 +27,9 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
{
|
{
|
||||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||||
|
|
||||||
/// Operations running in more then one state
|
IList<Event> e = new List<Event>(); /// Events from currently running operations
|
||||||
checkUiOp = new Operations.CheckUIOp(true);
|
Event retVal = Event.Done;
|
||||||
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
IList<Event> e; /// Events from currently running operations
|
|
||||||
Event retVal = Event.Done;
|
|
||||||
|
|
||||||
ltrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
ltrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
||||||
|
|
||||||
|
|||||||
@@ -27,11 +27,9 @@ namespace TBF.BenchControl.TestMethods.FlyingStart
|
|||||||
{
|
{
|
||||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||||
|
|
||||||
/// Operations running in more then one state
|
IList<Event> e = new List<Event>(); /// Events from currently running operations
|
||||||
checkUiOp = new Operations.CheckUIOp(true);
|
Event retVal = Event.Done;
|
||||||
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
IList<Event> e; /// Events from currently running operations
|
|
||||||
Event retVal = Event.Done;
|
|
||||||
|
|
||||||
ltrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
ltrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
||||||
|
|
||||||
|
|||||||
+3
-5
@@ -27,11 +27,9 @@ namespace TBF.BenchControl.TestMethods.FlyingStartCollectionMethod
|
|||||||
{
|
{
|
||||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||||
|
|
||||||
/// Operations running in more then one state
|
IList<Event> e = new List<Event>(); /// Events from currently running operations
|
||||||
checkUiOp = new Operations.CheckUIOp(true);
|
Event retVal = Event.Done;
|
||||||
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
IList<Event> e; /// Events from currently running operations
|
|
||||||
Event retVal = Event.Done;
|
|
||||||
|
|
||||||
ltrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
ltrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
||||||
|
|
||||||
|
|||||||
+3
-5
@@ -27,11 +27,9 @@ namespace TBF.BenchControl.TestMethods.ReferenceFlowmeterCalibration
|
|||||||
{
|
{
|
||||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||||
|
|
||||||
/// Operations running in more then one state
|
IList<Event> e = new List<Event>(); /// Events from currently running operations
|
||||||
checkUiOp = new Operations.CheckUIOp(true);
|
Event retVal = Event.Done;
|
||||||
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
IList<Event> e; /// Events from currently running operations
|
|
||||||
Event retVal = Event.Done;
|
|
||||||
|
|
||||||
ltrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
ltrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
||||||
|
|
||||||
|
|||||||
Reference in New Issue
Block a user