Heat meters path checked when a test with heat meters is started.

This commit is contained in:
Milan Hanajik
2016-07-07 09:52:54 +02:00
parent a1a0e319ce
commit 19dc994616
2 changed files with 34 additions and 28 deletions
@@ -487,10 +487,11 @@ namespace TBF.BenchControl.Sequences
/// Try to fetch all test paths and transitions
/// to detect configuration errors as early as possible.
string errorMsg;
if (!StateMachine.GetPaths(test, out inPath, out benchPath, out outPath, out sensPath,
out heatMetersPath,
out transitionBefore, out transitionAfter,
out errorMsg))
if (!StateMachine.GetPaths(test, (StateMachine.Procedure.MetersKind == MetersKind.HeatMeter),
out inPath, out benchPath, out outPath, out sensPath,
out heatMetersPath,
out transitionBefore, out transitionAfter,
out errorMsg))
{
UiBridge.Bridge.OnError(this, errorMsg);
goto select_cycle_or_test;
@@ -504,11 +505,12 @@ namespace TBF.BenchControl.Sequences
/// Fetch the test paths and transitions
string errorMsg;
if (!StateMachine.GetPaths(test, out inPath, out benchPath, out outPath, out sensPath,
out heatMetersPath,
out transitionBefore, out transitionAfter,
out errorMsg))
{
if (!StateMachine.GetPaths(test, (StateMachine.Procedure.MetersKind == MetersKind.HeatMeter),
out inPath, out benchPath, out outPath, out sensPath,
out heatMetersPath,
out transitionBefore, out transitionAfter,
out errorMsg))
{
UiBridge.Bridge.OnError(this, errorMsg);
goto select_cycle_or_test;
}
@@ -585,11 +587,12 @@ namespace TBF.BenchControl.Sequences
/// Try to fetch all test paths and transitions
/// to detect configuration errors as early as possible.
string errorMsg;
if (!StateMachine.GetPaths(test, out inPath, out benchPath, out outPath, out sensPath,
out heatMetersPath,
out transitionBefore, out transitionAfter,
out errorMsg))
{
if (!StateMachine.GetPaths(test, (StateMachine.Procedure.MetersKind == MetersKind.HeatMeter),
out inPath, out benchPath, out outPath, out sensPath,
out heatMetersPath,
out transitionBefore, out transitionAfter,
out errorMsg))
{
UiBridge.Bridge.OnError(this, errorMsg);
goto select_cycle_or_test;
}
@@ -602,11 +605,12 @@ namespace TBF.BenchControl.Sequences
/// Fetch the test paths and transitions
string errorMsg;
if (!StateMachine.GetPaths(test, out inPath, out benchPath, out outPath, out sensPath,
out heatMetersPath,
out transitionBefore, out transitionAfter,
out errorMsg))
{
if (!StateMachine.GetPaths(test, (StateMachine.Procedure.MetersKind == MetersKind.HeatMeter),
out inPath, out benchPath, out outPath, out sensPath,
out heatMetersPath,
out transitionBefore, out transitionAfter,
out errorMsg))
{
UiBridge.Bridge.OnError(this, errorMsg);
goto select_cycle_or_test;
}
@@ -659,10 +663,11 @@ namespace TBF.BenchControl.Sequences
/// Fetch the test paths and transitions
string errorMsg;
if (!StateMachine.GetPaths(test, out inPath, out benchPath, out outPath, out sensPath,
out heatMetersPath,
out transitionBefore, out transitionAfter,
out errorMsg))
if (!StateMachine.GetPaths(test, (StateMachine.Procedure.MetersKind == MetersKind.HeatMeter),
out inPath, out benchPath, out outPath, out sensPath,
out heatMetersPath,
out transitionBefore, out transitionAfter,
out errorMsg))
{
UiBridge.Bridge.OnError(this, errorMsg);
goto select_cycle_or_test;
@@ -418,6 +418,7 @@ namespace TBF.BenchControl
/// <param name="errorMsg">Error message in case of incorrect configuration</param>
/// <returns>true when loaded configuration is correct (all four paths are defined !=null, etc.)</returns>
public static bool GetPaths(Test test,
bool heatMetersPathRequired,
out FeedingPath pfeed,
out BenchPath pben,
out OutputPath pout,
@@ -462,12 +463,12 @@ namespace TBF.BenchControl
{
if (test.HeatMetersPath == path.Name) { phmtrs = new HeatMetersPath(path, components); break; }
}
if (phmtrs == null)
{
errorMsg = "Cannot load paths";
return false;
}
#endif
if (heatMetersPathRequired && phmtrs == null)
{
errorMsg = "Cannot load heat meters sensors";
return false;
}
foreach (var tr in TransitionSequences)
{