E1 error indicator modified, average flow calculated from CTV volume and test time verified, ver. 2.18.1019

This commit is contained in:
Milan Hanajik
2018-10-11 10:58:08 +02:00
parent 5a2d51db95
commit 1620758545
2 changed files with 4 additions and 4 deletions
@@ -42,8 +42,8 @@ namespace TBF.BenchControl.Various.ErrorFlags
/// Any E# is 'true' on error, 'false' when OK
/// Average flow
bool E1 = ProcessData.RefFlowStat.Average < testRslt.Qfrom()
|| ProcessData.RefFlowStat.Average > testRslt.Qto();
double aveFlow = 3.6 * testRslt.VolumeCTV / testRslt.TestTime;
bool E1 = (aveFlow < testRslt.Qfrom()) || (aveFlow > testRslt.Qto());
/// Max. and min. up and down water temperature
bool E2 = ProcessData.TempUpStat.Min < testRslt.TempLimLo()