Refactoring : TestBenchFramework --> TBF ver. 2.18.789
This commit is contained in:
@@ -0,0 +1,199 @@
|
||||
///
|
||||
/// Copyright (c) 2013-2017 Sensus Metering Systems
|
||||
///
|
||||
namespace TBF.BenchControl
|
||||
{
|
||||
/// <summary>
|
||||
/// Lower level measurement event provided by devices and polled by operations
|
||||
/// </summary>
|
||||
public enum MsrmntState
|
||||
{
|
||||
Valid,
|
||||
Overload,
|
||||
Failed,
|
||||
Busy,
|
||||
Busy1, ///
|
||||
Busy2, /// Used by Mettler-Toledo Multi to distinguish which scale was queried
|
||||
Busy3, ///
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Flags returned by each device configuration control Verify(...) function.
|
||||
/// </summary>
|
||||
public enum CfgUpdateFlags
|
||||
{
|
||||
None = 0,
|
||||
Error = 0x1, /// Some settings in the user control are invalid and cannot be set
|
||||
Warning = 0x02, /// Some settings in the user control are suspicious, can be set after user confirmation
|
||||
RestartRqrd = 0x04, /// TBF program restart is required to apply all changed parameters
|
||||
AnyChange = 0x08, /// At least one parameter have changed
|
||||
VolatileChange = 0x10,
|
||||
InvokeCfgChange = 0x20, /// Invoke CfgChange handler of the component
|
||||
}
|
||||
|
||||
public enum CfgChangeCmd
|
||||
{
|
||||
None,
|
||||
CfgChange, /// Configuation change
|
||||
ValveOpen, /// Open a valve
|
||||
ValveClose, /// Close a valve
|
||||
RVOpenStep, /// Open a regulation valve (RV only)
|
||||
RVCloseStep, /// Close a regulation valve *RV only)
|
||||
DivToTank, /// Diverter to tank (Div only)
|
||||
DivToSink, /// Diverter to sink (Div only)
|
||||
ReadDivTransition, /// Read diverter ADC value transition
|
||||
GetAdc, /// Get regul.valve or diverter ADC
|
||||
GetAdc1, /// Get regul.valve or diverter ADC feedback value #1
|
||||
GetAdc2, /// Get regul.valve or diverter ADC feedback value #2
|
||||
}
|
||||
|
||||
public enum ValveCategory
|
||||
{
|
||||
All = 0, /// Valve will be shown in all paths
|
||||
Feeding, /// Valve will be shown in Feeding paths
|
||||
Bench, /// Valve will be shown in Bench paths
|
||||
Output, /// Valve will be shown in Output paths
|
||||
None, /// Valve will not be shown in the paths
|
||||
}
|
||||
|
||||
public enum ValveExOperation
|
||||
{
|
||||
Or,
|
||||
And,
|
||||
}
|
||||
|
||||
public enum PumpProtocol
|
||||
{
|
||||
Modbus, /// Modbus protocol, default serial settings are 9600Bd, 8bits, NoP, 1stop
|
||||
FC, /// FC protocol with Siemens address (1..31), default serial settings are 9600Bd, 8bits, PE, 1stop
|
||||
}
|
||||
|
||||
public enum UIFlowControl
|
||||
{
|
||||
Continue,
|
||||
Stop,
|
||||
}
|
||||
|
||||
public enum CompoundTestType
|
||||
{
|
||||
Regular,
|
||||
DetectionRise,
|
||||
DetectionFall,
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// StateMachine events (issued by operations, IOperation derived classes)
|
||||
/// </summary>
|
||||
public enum Event
|
||||
{
|
||||
None = 0,
|
||||
Busy, /// Useful when waiting in state until at least one is busy (all are done)
|
||||
Done, /// Useful when waiting in state until the first is done, the rest miht still be busy
|
||||
MakeSecondPass, /// Test completed OK but 2nd pass (evaluation) is required
|
||||
///
|
||||
ModelessFormIsOpen,
|
||||
ModelessFormClosed,
|
||||
|
||||
ValvesBusy,
|
||||
ValvesSet,
|
||||
|
||||
AmbientDone,
|
||||
BalanceDone,
|
||||
BalanceOverload,
|
||||
PressureDone,
|
||||
PressureInDone,
|
||||
PressureOutDone,
|
||||
TempDone,
|
||||
TempInDone,
|
||||
TempOutDone,
|
||||
TempDivDone,
|
||||
FlowMeasurementDone,
|
||||
FlowReached,
|
||||
PositionReached,
|
||||
RegulValveTimeOut, /// Maximum allowed flow setting time has elapsed
|
||||
ReadRegisterDone,
|
||||
ReadReferenceDone,
|
||||
AllPositionsReached, /// Used in SetAllRegulValvesOp
|
||||
TurnPumpOnOffDone,
|
||||
|
||||
/// CheckUi events
|
||||
UiCmdReloadBatch,
|
||||
UiCmdStartTest,
|
||||
UiCmdStartQ1,
|
||||
UiCmdStartQ2,
|
||||
UiCmdStartQ3,
|
||||
UiCmdStartCycle,
|
||||
UiCmdStop,
|
||||
UiCmdPurgeBegin,
|
||||
UiCmdPurgeEnd,
|
||||
UiCmdDrainTank1,
|
||||
UiCmdDrainTank2,
|
||||
UiCmdDrainTank3,
|
||||
UiCmdStopDrainingTank1,
|
||||
UiCmdStopDrainingTank2,
|
||||
UiCmdStopDrainingTank3,
|
||||
UiCmdBreak,
|
||||
UiCmdResetResults,
|
||||
UiCmdAcceptResults,
|
||||
UiCmdCalibration,
|
||||
UiCmdCameraTest,
|
||||
UiCmdSensitivityTest,
|
||||
UiCmdCustom,
|
||||
UiCmdB1,
|
||||
UiCmdB2,
|
||||
UiCmdB3,
|
||||
|
||||
/// Process/Test oriented
|
||||
PreviousStopped,
|
||||
Wait,
|
||||
ProcedureLoaded,
|
||||
MeasurementStarted,
|
||||
ReadAllRegistersDone,
|
||||
MeasurementCompleted,
|
||||
CommandCompleted,
|
||||
|
||||
/// At the end of cycle when saving /printing resultss
|
||||
ResultsPrinted,
|
||||
ResultsWritten,
|
||||
ResultsNotWritten,
|
||||
|
||||
/// Timer events
|
||||
TimerExpired,
|
||||
|
||||
/// Process camera events
|
||||
CameraBusy,
|
||||
GrabPassed,
|
||||
GrabFailed,
|
||||
RoiDetectionPassed,
|
||||
RoiDetectionFailed,
|
||||
RoiDetectionPreviousFailed,
|
||||
|
||||
/// Generic
|
||||
Error, /// Many ops.: Fatal error occurred
|
||||
OpArgumentError,
|
||||
ConfigurationError,
|
||||
Yes,
|
||||
No,
|
||||
Next, /// To move to the next state when debugging
|
||||
OK,
|
||||
Retry,
|
||||
Abort,
|
||||
TimerBusy,
|
||||
SetOutputsDone,
|
||||
|
||||
/// Sequence conditions
|
||||
ConditionNotMet,
|
||||
ConditionMet,
|
||||
|
||||
/// Outer loop control
|
||||
OuterLoopStart,
|
||||
OuterLoopEnd,
|
||||
|
||||
/// Production monitoring
|
||||
CheckDone,
|
||||
CheckNotDone,
|
||||
|
||||
/// Error evaluation
|
||||
ErrorConditionsDone,
|
||||
}
|
||||
}
|
||||
Reference in New Issue
Block a user