UpdateTankWeightOp removed, ver. 2.18.1061

This commit is contained in:
Milan Hanajik
2018-11-13 15:29:18 +01:00
parent 76a08324b4
commit 05f6c8c75c
21 changed files with 17 additions and 192 deletions
@@ -180,7 +180,6 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
///
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
// .AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
.AddOperation(heatMetersPromptOp)
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
@@ -202,8 +201,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
.AddOperation(heatMetersPromptOp)
.AddOperation(heatMetersPromptOp)
.EnterState();
do
{
@@ -222,8 +220,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
.AddOperation(heatMetersPromptOp)
.AddOperation(heatMetersPromptOp)
.EnterState();
do
{
@@ -240,8 +237,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
.AddOperation(heatMetersPromptOp)
.AddOperation(heatMetersPromptOp)
.EnterState();
do
{
@@ -262,7 +258,6 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
//------------------------------------------------
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, 990)) /// timeout = 16.5 min.
.AddOperation(heatMetersPromptOp)
.EnterState();
@@ -461,7 +456,6 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
.AddOperation(cBrd.UpdateTankWeightOp())
.AddOperation(new Operations.TimerOp(test.TimeFlow2Mass))
.EnterState();
do
@@ -494,7 +488,6 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
.AddOperation((StateMachine.Ambient != null)
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
.AddOperation(scale.ReadStableMassOp(ref StartMass, test.MassRepeats, test.MassSpread, test.MassMethod))
.AddOperation(cBrd.UpdateTankWeightOp())
.AddOperation(processDataLoggingOp)
.EnterState();
do
@@ -530,7 +523,6 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
.AddOperation((StateMachine.Ambient != null)
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
.AddOperation(cBrd.UpdateTankWeightOp())
.AddOperation(processDataLoggingOp)
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Diverter | Elde.TestMethods.Synchro,
test.Qfrom, test.Qto, totalPulses, filters))
@@ -578,8 +570,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
.AddOperation(scale.ReadMassOp(ref Mass))
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
.AddOperation((StateMachine.Ambient != null)
.AddOperation((StateMachine.Ambient != null)
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi)
: null)
.AddOperation(cBrd.ReadDiverterTransitionOp(outPath.Diverter, 2, 4, switchTimeStart, DiverterStart, BatchRslts.Batch.BatchNr, test.Name, repetitionNr))
@@ -652,7 +643,6 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
State.Create("SequenceBase : Transition : TestEnd - Default action")
.AddOperation(checkUiOp)
.AddOperation(new MettlerToledo.KeepReadingMassesOp())
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
.AddOperation(StateMachine.ControlBoard.SetValvesOp(StateMachine.DefaultValvesOpen,
StateMachine.DefaultValvesClose))
.EnterState();
@@ -683,7 +673,6 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
.AddOperation((StateMachine.Ambient != null)
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
.AddOperation(scale.ReadMassOp(ref Mass))
.AddOperation(cBrd.UpdateTankWeightOp())
.AddOperation(cBrd.ReadDiverterTransitionOp(outPath.Diverter, 2, 4, switchTimeEnd, DiverterEnd, BatchRslts.Batch.BatchNr, test.Name, repetitionNr))
.AddOperation(processDataLoggingOp)
.AddOperation(new Operations.TimerOp(test.TimeStop2Mass))
@@ -715,7 +704,6 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
.AddOperation((StateMachine.Ambient != null)
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
.AddOperation(scale.ReadStableMassOp(ref EndMass, test.MassRepeats, test.MassSpread, test.MassMethod))
.AddOperation(cBrd.UpdateTankWeightOp())
.AddOperation(processDataLoggingOp)
.EnterState();
do