- RegulValve ADC Open/Close values calibration implemented
- 'More' button added to ComponentCfgCtrl-s - Dataflow from ComponentParametersDlg to components: CfgChangeHandler - Dataflow from components to ComponentParametersDlg: CmdResponseHandler - Detection of parameter changes and appropriate MesssageBox display: 1.warning message when component configuration change requires program restart 2.confirmation message box when any configuration changes would be lost
This commit is contained in:
@@ -29,6 +29,56 @@ namespace TBF.BenchControl.Elde.RegulValve
|
||||
get { return controlBoard.RValvePosition(Idx1); }
|
||||
}
|
||||
|
||||
|
||||
#region Configuration Change Handling
|
||||
|
||||
public static void OnCfgChange(object sender, CfgChangeArgs args)
|
||||
{
|
||||
if (CfgChangeHandler == null) return;
|
||||
try { CfgChangeHandler(sender, args); }
|
||||
catch (Exception e) { log.Error("CfgChangeHandler(...) failed", e); }
|
||||
}
|
||||
|
||||
public static event EventHandler<CfgChangeArgs> CfgChangeHandler;
|
||||
|
||||
public override void StartChangeHandler()
|
||||
{
|
||||
CfgChangeHandler += delegate(object sender, CfgChangeArgs args)
|
||||
{
|
||||
RegulValveCfg tmpcfg = args.Cfg as RegulValveCfg;
|
||||
if (tmpcfg != null && tmpcfg.Name.Equals(Name))
|
||||
{
|
||||
if (args.Command == CfgChangeCmd.CfgChange)
|
||||
{
|
||||
RegulValveCfg.PidCoef = tmpcfg.PidCoef;
|
||||
RegulValveCfg.StableTimeMs = tmpcfg.StableTimeMs;
|
||||
RegulValveCfg.FlowStableSec = tmpcfg.FlowStableSec;
|
||||
}
|
||||
else if (args.Command == CfgChangeCmd.RVOpenStep)
|
||||
{
|
||||
controlBoard.ValveMove(Idx1, RegulValveMode.PulseWidth, new float[2] { 0.05f, 0.05f }, StableTime);
|
||||
// TODO: avoid conflicts
|
||||
// TOTEST
|
||||
}
|
||||
else if (args.Command == CfgChangeCmd.RVCloseStep)
|
||||
{
|
||||
controlBoard.ValveMove(Idx1, RegulValveMode.PulseWidth, new float[2] { -0.05f, -0.05f }, StableTime);
|
||||
// TODO: avoid conflicts
|
||||
// TOTEST
|
||||
}
|
||||
else if (args.Command == CfgChangeCmd.GetRVAdc1 || args.Command == CfgChangeCmd.GetRVAdc2)
|
||||
{
|
||||
int adc = (int)controlBoard.AnalogInputRaw(Idx1, 0);
|
||||
// TOTEST
|
||||
RegulValveCfgCtrl.OnCmdResponse(this, new CmdResponseArgs(args.Command, adc));
|
||||
}
|
||||
}
|
||||
};
|
||||
}
|
||||
|
||||
#endregion Configuration Change Handling
|
||||
|
||||
|
||||
public RegulValve(RegulValveCfg cfg, IList<Generic.IComponent> components)
|
||||
: base(cfg)
|
||||
{
|
||||
|
||||
Reference in New Issue