laatzen/LaaProductionWeb/LaaProduction.Services/ReportService.cs
2024-09-18 16:08:46 +02:00

394 lines
20 KiB
C#

namespace LaaProduction.Services
{
using LaaPackages.SqlClient;
using LaaProduction.Services.Interfaces;
using LaaProduction.Services.Models.Reports;
using System;
using System.Collections.Generic;
using System.Linq;
using System.Text;
public partial class ReportService : IReportService
{
private readonly SqlConnection sqlConnection;
public ReportService(SqlConnection sqlConnection)
=> this.sqlConnection = sqlConnection;
public CordonelPressureSensorModel LoadCordonelPressureSensorReport(CordonelPressureSensorModel model = null)
{
if (model is null)
{
model = new CordonelPressureSensorModel();
}
var where = model.Filter.Where();
var orderBy = model.Filter.OrderBy();
model.Items = this.sqlConnection
.CreateCommand($@"
SELECT [APS].[AuftragNr] AS [AuftragNr]
, [APS].[PositionNr] AS [PosNr]
, [APS].[SerienNr] AS [SerialNr]
, [APS].[KundeneigeneSerienNr] AS [CustomerSerialNr]
, [ID].[IdentNr] AS [IdentNr]
, [CPSTR].[PcbId] AS [PcbId]
, [ID].[Typ] AS [TypeI]
, [ID].[Typzusatz] AS [TypeII]
, [ID].[Nennweite] AS [Nennweite]
, [ID].[Baulaenge] AS [Baulaenge]
, [CPSTR].[AvgPressureInBar] AS [AvgPressure]
, [CPSTR].[TestPassed] AS [TestPassed]
, [CPSTR].[TestDate] AS [TestDate]
FROM [Cordonel_PressureSensor_TestResults] AS [CPSTR]
LEFT JOIN [AuftragPositionSerienNr] AS [APS]
ON [APS].[FabNr] = [CPSTR].[PcbId]
LEFT JOIN [AuftragPosition_Gesamt] AS [APG]
ON [APG].[AuftragNr] = [APS].[AuftragNr]
AND [APG].[PositionNr] = [APS].[PositionNr]
LEFT JOIN [Identnr] AS [ID]
ON [ID].[IdentNr] = [APG].[Identnr]
WHERE {where.Query}
ORDER BY {orderBy.Query}")
.SetParameters(where.Parameters)
.SetParameters(orderBy.Parameters)
.ExecuteReader(reader => new CordonelPressureSensorItem
{
AuftragNr = reader.GetValue<Int32?>(0),
PosNr = reader.GetValue<Int16?>(1),
SerialNr = reader.GetValue<Int32?>(2),
CustomerSerialNr = reader.GetValue<String>(3),
IdentNr = reader.GetValue<Int32?>(4),
PcbId = reader.GetValue<Int32>(5),
TypeI = reader.GetValue<String>(6),
TypeII = reader.GetValue<String>(7),
Nennweite = reader.GetValue<Int32?>(8),
Baulaenge = reader.GetValue<Int32?>(9),
AVGPressure = reader.GetValue<Single>(10),
TestPassed = reader.GetValue<Boolean>(11),
TestDate = reader.GetValue<DateTime>(12),
});
return model;
}
public HeliumReportModel LoadHeliumPressureReport(HeliumReportModel model = null)
{
if (model is null)
{
model = new HeliumReportModel();
}
var where = model.Filter.Where();
var orderBy = model.Filter.OrderBy();
model.Items = this.sqlConnection
.CreateCommand($@"
SELECT DISTINCT
[PT].[CordonelPressureTest_FertigungsAuftragsNr] AS [FertigungNr] -- 0
, [POS].[AuftragNr] AS [AuftragNr] -- 1
, [POS].[PositionNr] AS [PositionNr] -- 2
, [PCB2SN].[MapPcbIdToSerialNumber_SerialNumber] AS [SerialNr] -- 3
, [ID].[IdentNr] AS [IdentNr] -- 4
, [PT_HE].[CordonelPressureTestHe_Id] AS [HeId] -- 5
, [PT_HE].[CordonelPressureTestHe_TestID] AS [HeTestId] -- 6
, [PT].[CordonelPressureTest_PcbId] AS [PcbId] -- 7
, [ID].[Nennweite] AS [Nennweite] -- 8
, [ID].[Baulaenge] AS [Baulaenge] -- 9
, [ID].[Typ] AS [Typ] -- 10
, [ID].[Druck] AS [Druck] -- 11
, [ID].[Temperatur] AS [Temperatur] -- 12
, [PT_HE].[CordonelPressureTestHe_LeakRate] AS [HeLakeRate] -- 13
, [PT_HE].[CordonelPressureTestHe_TestPressure] AS [HeTestPressure] -- 14
, [PT].[CordonelPressureTest_Valid] AS [IsValid] -- 15
, [PT].[CordonelPressureTest_Date] AS [TestDate] -- 16
, [PT].[CordonelPressureTest_Text] AS [Text] -- 17
, [PT_HE].[CordonelPressureTestHe_TesterName] AS [Tester] -- 18
FROM [Cordonel_PressureTest] AS [PT]
JOIN [Cordonel_PressureTest_He] AS [PT_HE] ON [PT_HE].[CordonelPressureTestHe_TestID] = [PT].[CordonelPressureTest_Id]
LEFT JOIN [Druckpruefung] AS [DP] ON [DP].[FabNr] = [PT].[CordonelPressureTest_PcbId]
JOIN [MapPcbIdToSerialNumber] AS [PCB2SN] ON [PCB2SN].[MapPcbIdToSerialNumber_PcbId] = [PT].[CordonelPressureTest_PcbId]
JOIN [AuftragPosition_Gesamt] AS [POS] ON [POS].[FertigungsauftragNr] = [PT].[CordonelPressureTest_FertigungsAuftragsNr]
JOIN [Identnr] AS [ID] ON [ID].[IdentNr] = [POS].[Identnr]
WHERE [CordonelPressureTest_IsDeleted] = 0
AND {where.Query}
ORDER BY {orderBy.Query}")
.SetParameters(where.Parameters)
.SetParameters(orderBy.Parameters)
.ExecuteReader(reader => new HeliumReportItem
{
FertigungNr = reader.GetValue<Int32>(0),
AuftragNr = reader.GetValue<Int32>(1),
PositionNr = reader.GetValue<Int16>(2),
SerialNr = reader.GetValue<Int32>(3),
IdentNr = reader.GetValue<Int32>(4),
HeId = reader.GetValue<Int32>(5),
HeTestId = reader.GetValue<Int32>(6),
PcbId = reader.GetValue<Int32>(7),
Nennweite = reader.GetValue<Int32?>(8),
Baulaenge = reader.GetValue<Int32?>(9),
Typ = reader.GetValue<String>(10),
Druck = reader.GetValue<Int32?>(11),
Temperatur = reader.GetValue<Int32?>(12),
HeLakeRate = reader.GetValue<String>(13),
HeTestPressure = reader.GetValue<String>(14),
IsValid = reader.GetValue<Boolean>(15),
TestDate = reader.GetValue<DateTimeOffset>(16),
Text = reader.GetValue<String>(17),
Tester = reader.GetValue<String>(18)
});
return model;
}
public Byte[] LoadHeliumPressureReportAsCSV(HeliumReportModel model)
{
if (model is null)
{
model = new HeliumReportModel();
}
var where = model.Filter.Where();
var orderBy = model.Filter.OrderBy();
var csvItems = new List<Object[]>
{
new Object[]
{
"[FertigungNr]",
"[AuftragNr]",
"[PositionNr]",
"[SerialNr]",
"[IdentNr]",
"[HeId]",
"[HeTestId]",
"[PcbId]",
"[Nennweite]",
"[Baulaenge]",
"[Typ]",
"[Druck]",
"[Temperatur]",
"[HeLakeRate]",
"[HeTestPressure]",
"[IsValid]",
"[TestDate]",
"[Text]",
"[Tester]",
}
};
var headers = Array.Empty<String>();
var items = this.sqlConnection
.CreateCommand($@"
SELECT DISTINCT
[PT].[CordonelPressureTest_FertigungsAuftragsNr] AS [FertigungNr] -- 0 Filter
, [POS].[AuftragNr] AS [AuftragNr] -- 1 Filter
, [POS].[PositionNr] AS [PositionNr] -- 2 Filter
, [PCB2SN].[MapPcbIdToSerialNumber_SerialNumber] AS [SerialNr] -- 3
, [ID].[IdentNr] AS [IdentNr] -- 4 Filter
, [PT_HE].[CordonelPressureTestHe_Id] AS [HeId] -- 5
, [PT_HE].[CordonelPressureTestHe_TestID] AS [HeTestId] -- 6
, [PT].[CordonelPressureTest_PcbId] AS [PcbId] -- 7 Filter
, [ID].[Nennweite] AS [Nennweite] -- 8 Filter
, [ID].[Baulaenge] AS [Baulaenge] -- 9 Filter
, [ID].[Typ] AS [Typ] -- 10 Filter
, [ID].[Druck] AS [Druck] -- 11 Filter
, [ID].[Temperatur] AS [Temperatur] -- 12 Filter
, [PT_HE].[CordonelPressureTestHe_LeakRate] AS [HeLakeRate] -- 13
, [PT_HE].[CordonelPressureTestHe_TestPressure] AS [HeTestPressure] -- 14
, [PT].[CordonelPressureTest_Valid] AS [IsValid] -- 15 Filter
, [PT].[CordonelPressureTest_Date] AS [TestDate] -- 16 Filter
, [PT].[CordonelPressureTest_Text] AS [Text] -- 17 Filter
, [PT_HE].[CordonelPressureTestHe_TesterName] AS [Tester] -- 18
FROM [Cordonel_PressureTest] AS [PT]
JOIN [Cordonel_PressureTest_He] AS [PT_HE] ON [PT_HE].[CordonelPressureTestHe_TestID] = [PT].[CordonelPressureTest_Id]
LEFT JOIN [Druckpruefung] AS [DP] ON [DP].[FabNr] = [PT].[CordonelPressureTest_PcbId]
JOIN [MapPcbIdToSerialNumber] AS [PCB2SN] ON [PCB2SN].[MapPcbIdToSerialNumber_PcbId] = [PT].[CordonelPressureTest_PcbId]
JOIN [AuftragPosition_Gesamt] AS [POS] ON [POS].[FertigungsauftragNr] = [PT].[CordonelPressureTest_FertigungsAuftragsNr]
JOIN [Identnr] AS [ID] ON [ID].[IdentNr] = [POS].[Identnr]
WHERE [CordonelPressureTest_IsDeleted] = 0
AND {where.Query}
ORDER BY {orderBy.Query}")
.SetParameters(where.Parameters)
.SetParameters(orderBy.Parameters)
.ExecuteReader(reader => new Object[]
{
reader.GetValue<Int32>(0),
reader.GetValue<Int32>(1),
reader.GetValue<Int16>(2),
reader.GetValue<Int32>(3),
reader.GetValue<Int32>(4),
reader.GetValue<Int32>(5),
reader.GetValue<Int32>(6),
reader.GetValue<Int32>(7),
reader.GetValue<Int32?>(8),
reader.GetValue<Int32?>(9),
reader.GetValue<String>(10).Replace(',', ' '),
reader.GetValue<Int32?>(11),
reader.GetValue<Int32?>(12),
reader.GetValue<String>(13).Replace(',', '.'),
reader.GetValue<String>(14).Replace(',', ' '),
reader.GetValue<Boolean>(15),
$"{reader.GetValue<DateTimeOffset>(16):yyyy-MM-dd}",
reader.GetValue<String>(17).Replace(',', ' '),
reader.GetValue<String>(18).Replace(',', ' ')
});
csvItems.AddRange(items);
var csvLines = csvItems.Select(x => String.Join(",", x));
var csvContent = String.Join(Environment.NewLine, csvLines);
return Encoding.UTF8.GetBytes(csvContent);
}
public IEnumerable<HeliumPressurePoint> LoadHeliumPressureResults(Int32 testId)
=> this.sqlConnection
.CreateCommand($@"
SELECT [CordonelPressureTestTestPoints_Id]
, [CordonelPressureTest_TestPointNr]
, CAST([CordonelPressureTest_TestPointResult] AS NUMERIC(9, 8))
FROM [Cordonel_PressureTest_TestPoints]
WHERE [CordonelPressureTest_Id] = @{nameof(testId)}")
.SetParameter(nameof(testId), testId)
.ExecuteReader(reader => new HeliumPressurePoint
{
TestId = reader.GetValue<Int32>(0),
PointNr = reader.GetValue<Int32>(1),
Result = reader.GetValue<Decimal>(2),
});
public KottmannReportModel LoadKottmannPressureReport(KottmannReportModel model = null)
{
if (model is null)
{
model = new KottmannReportModel();
}
var where = model.Filter.Where();
var orderBy = model.Filter.OrderBy();
model.Items = this.sqlConnection
.CreateCommand($@"
SELECT [DP].[FertigungsauftragNr] AS [FertigungNr]
, [PCB2SN].[MapPcbIdToSerialNumber_SerialNumber] AS [SerienNr]
, [DP].[FabNr] AS [PcbId]
, [ID].[Typ] AS [Typ]
, [ID].[Nennweite] AS [Nennweite]
, [ID].[Baulaenge] AS [Baulaenge]
, [DP].[StartDruck] AS [StartDruck]
, [DP].[EndDruck] AS [EndDruck]
, [DP].[Pruefzeit] AS [Pruefzeit]
, [DP].[Dicht] AS [Dicht]
, [DP].[Datum] AS [Datum]
, [DP].[Bemerkung] AS [Bemerkung]
FROM [Druckpruefung] AS [DP]
JOIN [AuftragPosition_Gesamt] AS [POS]
ON [POS].[FertigungsauftragNr] = [DP].[FertigungsauftragNr]
JOIN [Identnr] AS [ID]
ON [ID].[IdentNr] = [POS].[Identnr]
JOIN [MapPcbIdToSerialNumber] AS [PCB2SN]
ON [PCB2SN].[MapPcbIdToSerialNumber_PcbId] = [DP].[FabNr]
AND [PCB2SN].[MapPcbIdToSerialNumber_Deleted] = 0
AND {where.Query}
ORDER BY {orderBy.Query}")
.SetParameters(where.Parameters)
.SetParameters(orderBy.Parameters)
.ExecuteReader(reader => new KottmannReportItem
{
FertigungsNr = reader.GetValue<Int32?>(0),
SerialNr = reader.GetValue<Int32>(1),
PcbId = reader.GetValue<Int32>(2),
Typ = reader.GetValue<String>(3),
Nennweite = reader.GetValue<Int32?>(4),
Baulaenge = reader.GetValue<Int32?>(5),
StartDruck = reader.GetValue<Double>(6),
EndDruck = reader.GetValue<Double>(7),
DruckZeit = reader.GetValue<Int32>(8),
Dicht = reader.GetValue<Boolean>(9),
Datum = reader.GetValue<DateTime>(10),
Bemerkung = reader.GetValue<String>(11)
});
return model;
}
public Byte[] LoadKottmannPressureReportAsCSV(KottmannReportModel model)
{
if (model is null)
{
model = new KottmannReportModel();
}
var where = model.Filter.Where();
var orderBy = model.Filter.OrderBy();
var csvItems = new List<Object[]>
{
new Object[]
{
"[FertigungNr]",
"[SerienNr]",
"[PcbId]",
"[Typ]",
"[Nennweite]",
"[Baulaenge]",
"[StartDruck]",
"[EndDruck]",
"[Pruefzeit]",
"[Dicht]",
"[Datum]",
"[Bemerkung]"
}
};
var headers = Array.Empty<String>();
var items = this.sqlConnection
.CreateCommand($@"
SELECT [DP].[FertigungsauftragNr] AS [FertigungNr]
, [PCB2SN].[MapPcbIdToSerialNumber_SerialNumber] AS [SerienNr]
, [DP].[FabNr] AS [PcbId]
, [ID].[Typ] AS [Typ]
, [ID].[Nennweite] AS [Nennweite]
, [ID].[Baulaenge] AS [Baulaenge]
, [DP].[StartDruck] AS [StartDruck]
, [DP].[EndDruck] AS [EndDruck]
, [DP].[Pruefzeit] AS [Pruefzeit]
, [DP].[Dicht] AS [Dicht]
, [DP].[Datum] AS [Datum]
, [DP].[Bemerkung] AS [Bemerkung]
FROM [Druckpruefung] AS [DP]
JOIN [AuftragPosition_Gesamt] AS [POS]
ON [POS].[FertigungsauftragNr] = [DP].[FertigungsauftragNr]
JOIN [Identnr] AS [ID]
ON [ID].[IdentNr] = [POS].[Identnr]
JOIN [MapPcbIdToSerialNumber] AS [PCB2SN]
ON [PCB2SN].[MapPcbIdToSerialNumber_PcbId] = [DP].[FabNr]
AND [PCB2SN].[MapPcbIdToSerialNumber_Deleted] = 0
AND {where.Query}
ORDER BY {orderBy.Query}")
.SetParameters(where.Parameters)
.SetParameters(orderBy.Parameters)
.ExecuteReader(reader => new Object[]
{
reader.GetValue<Int32?>(0),
reader.GetValue<Int32>(1),
reader.GetValue<Int32>(2),
reader.GetValue<String>(3),
reader.GetValue<Int32?>(4),
reader.GetValue<Int32?>(5),
reader.GetValue<Double>(6),
reader.GetValue<Double>(7),
reader.GetValue<Int32>(8),
reader.GetValue<Boolean>(9),
$"{reader.GetValue<DateTime>(10):yyyy-MM-dd}",
reader.GetValue<String>(11).Replace(',', ' ')
});
csvItems.AddRange(items);
var csvLines = csvItems.Select(x => String.Join(",", x));
var csvContent = String.Join(Environment.NewLine, csvLines);
return Encoding.UTF8.GetBytes(csvContent);
}
}
}