Files
laatzen/LaaProductionWeb/LaaProductionWeb.Services/ReportService.cs
T

203 lines
11 KiB
C#

namespace LaaProductionWeb.Services
{
using LaaProductionWeb.Data.Interfaces;
using LaaProductionWeb.Services.Interfaces;
using LaaProductionWeb.Services.Models;
using System;
using System.Collections.Generic;
using System.Linq;
using System.Text;
public class ReportService : IReportService
{
private readonly ISqlClient sqlClient;
public ReportService(ISqlClient sqlClient)
=> this.sqlClient = sqlClient;
public HeliumReportModel LoadHeliumPressureReport(HeliumReportModel model = null)
{
if (model is null)
{
model = new HeliumReportModel();
}
var where = model.Filter.Where();
var orderBy = model.Filter.OrderBy();
model.Items = this.sqlClient.ExecuteReader($@"
SELECT [PT].[CordonelPressureTest_FertigungsAuftragsNr] AS [FertigungNr] -- 0 Filter
, [POS].[AuftragNr] AS [AuftragNr] -- 1 Filter
, [POS].[PositionNr] AS [PositionNr] -- 2 Filter
, [PCB2SN].[MapPcbIdToSerialNumber_SerialNumber] AS [SerialNr] -- 3
, [ID].[IdentNr] AS [IdentNr] -- 4 Filter
, [PT_HE].[CordonelPressureTestHe_Id] AS [HeId] -- 5
, [PT_HE].[CordonelPressureTestHe_TestID] AS [HeTestId] -- 6
, [PT].[CordonelPressureTest_PcbId] AS [PcbId] -- 7 Filter
, [ID].[Nennweite] AS [Nennweite] -- 8 Filter
, [ID].[Baulaenge] AS [Baulaenge] -- 9 Filter
, [ID].[Typ] AS [Typ] -- 10 Filter
, [ID].[Druck] AS [Druck] -- 11 Filter
, [ID].[Temperatur] AS [Temperatur] -- 12 Filter
, [PT_HE].[CordonelPressureTestHe_LeakRate] AS [HeLakeRate] -- 13
, [PT_HE].[CordonelPressureTestHe_TestPressure] AS [HeTestPressure] -- 14
, [PT].[CordonelPressureTest_Valid] AS [IsValid] -- 15 Filter
, [PT].[CordonelPressureTest_Date] AS [TestDate] -- 16 Filter
, [PT].[CordonelPressureTest_Text] AS [Text] -- 17 Filter
, [PT_HE].[CordonelPressureTestHe_TesterName] AS [Tester] -- 18
FROM [Cordonel_PressureTest] AS [PT]
JOIN [Cordonel_PressureTest_He] AS [PT_HE] ON [PT_HE].[CordonelPressureTestHe_TestID] = [PT].[CordonelPressureTest_Id]
LEFT JOIN [Druckpruefung] AS [DP] ON [DP].[FabNr] = [PT].[CordonelPressureTest_PcbId]
JOIN [MapPcbIdToSerialNumber] AS [PCB2SN] ON [PCB2SN].[MapPcbIdToSerialNumber_PcbId] = [PT].[CordonelPressureTest_PcbId]
JOIN [AuftragPosition_Gesamt] AS [POS] ON [POS].[FertigungsauftragNr] = [PT].[CordonelPressureTest_FertigungsAuftragsNr]
JOIN [Identnr] AS [ID] ON [ID].[IdentNr] = [POS].[Identnr]
WHERE [CordonelPressureTest_IsDeleted] = 0
AND {where.Query}
ORDER BY {orderBy.Query}",
parameters =>
{
foreach (var kvp in where.Parameters)
{
parameters.Add(kvp.Key, kvp.Value);
}
foreach (var kvp in orderBy.Parameters)
{
parameters.Add(kvp.Key, kvp.Value);
}
},
reader => new HeliumReportItem
{
FertigungNr = reader.GetValue<int>(0),
AuftragNr = reader.GetValue<int>(1),
PositionNr = reader.GetValue<short>(2),
SerialNr = reader.GetValue<int>(3),
IdentNr = reader.GetValue<int>(4),
HeId = reader.GetValue<int>(5),
HeTestId = reader.GetValue<int>(6),
PcbId = reader.GetValue<int>(7),
Nennweite = reader.GetValue<int?>(8),
Baulaenge = reader.GetValue<int?>(9),
Typ = reader.GetString(10),
Druck = reader.GetValue<int?>(11),
Temperatur = reader.GetValue<int?>(12),
HeLakeRate = reader.GetString(13),
HeTestPressure = reader.GetString(14),
IsValid = reader.GetValue<bool>(15),
TestDate = reader.GetValue<DateTimeOffset>(16),
Text = reader.GetString(17),
Tester = reader.GetString(18)
});
return model;
}
public byte[] LoadHeliumPressureReportAsCSV(HeliumReportModel model)
{
if (model is null)
{
model = new HeliumReportModel();
}
var where = model.Filter.Where();
var orderBy = model.Filter.OrderBy();
var csvItems = new List<object[]>();
var headers = Array.Empty<string>();
var items = this.sqlClient.ExecuteReader($@"
SELECT [PT].[CordonelPressureTest_FertigungsAuftragsNr] AS [FertigungNr] -- 0 Filter
, [POS].[AuftragNr] AS [AuftragNr] -- 1 Filter
, [POS].[PositionNr] AS [PositionNr] -- 2 Filter
, [PCB2SN].[MapPcbIdToSerialNumber_SerialNumber] AS [SerialNr] -- 3
, [ID].[IdentNr] AS [IdentNr] -- 4 Filter
, [PT_HE].[CordonelPressureTestHe_Id] AS [HeId] -- 5
, [PT_HE].[CordonelPressureTestHe_TestID] AS [HeTestId] -- 6
, [PT].[CordonelPressureTest_PcbId] AS [PcbId] -- 7 Filter
, [ID].[Nennweite] AS [Nennweite] -- 8 Filter
, [ID].[Baulaenge] AS [Baulaenge] -- 9 Filter
, [ID].[Typ] AS [Typ] -- 10 Filter
, [ID].[Druck] AS [Druck] -- 11 Filter
, [ID].[Temperatur] AS [Temperatur] -- 12 Filter
, [PT_HE].[CordonelPressureTestHe_LeakRate] AS [HeLakeRate] -- 13
, [PT_HE].[CordonelPressureTestHe_TestPressure] AS [HeTestPressure] -- 14
, [PT].[CordonelPressureTest_Valid] AS [IsValid] -- 15 Filter
, [PT].[CordonelPressureTest_Date] AS [TestDate] -- 16 Filter
, [PT].[CordonelPressureTest_Text] AS [Text] -- 17 Filter
, [PT_HE].[CordonelPressureTestHe_TesterName] AS [Tester] -- 18
, [CPT].[CordonelPressureTest_TestPointNr] AS [PointNr] -- 19
, CAST([CPT].[CordonelPressureTest_TestPointResult] AS NUMERIC(9, 8)) AS [PointResult] -- 20
FROM [Cordonel_PressureTest] AS [PT]
JOIN [Cordonel_PressureTest_He] AS [PT_HE] ON [PT_HE].[CordonelPressureTestHe_TestID] = [PT].[CordonelPressureTest_Id]
LEFT JOIN [Druckpruefung] AS [DP] ON [DP].[FabNr] = [PT].[CordonelPressureTest_PcbId]
JOIN [MapPcbIdToSerialNumber] AS [PCB2SN] ON [PCB2SN].[MapPcbIdToSerialNumber_PcbId] = [PT].[CordonelPressureTest_PcbId]
JOIN [AuftragPosition_Gesamt] AS [POS] ON [POS].[FertigungsauftragNr] = [PT].[CordonelPressureTest_FertigungsAuftragsNr]
JOIN [Identnr] AS [ID] ON [ID].[IdentNr] = [POS].[Identnr]
LEFT JOIN [Cordonel_PressureTest_TestPoints] AS [CPT] ON [CPT].[CordonelPressureTest_Id] = [PT].[CordonelPressureTest_Id]
WHERE [CordonelPressureTest_IsDeleted] = 0
AND {where.Query}
ORDER BY {orderBy.Query}",
parameters =>
{
foreach (var kvp in where.Parameters)
{
parameters.Add(kvp.Key, kvp.Value);
}
foreach (var kvp in orderBy.Parameters)
{
parameters.Add(kvp.Key, kvp.Value);
}
},
reader => new object[]
{
reader.GetValue<int>(0),
reader.GetValue<int>(1),
reader.GetValue<short>(2),
reader.GetValue<int>(3),
reader.GetValue<int>(4),
reader.GetValue<int>(5),
reader.GetValue<int>(6),
reader.GetValue<int>(7),
reader.GetValue<int?>(8),
reader.GetValue<int?>(9),
reader.GetString(10).Replace(',', ' '),
reader.GetValue<int?>(11),
reader.GetValue<int?>(12),
reader.GetString(13).Replace(',', '.'),
reader.GetString(14).Replace(',', ' '),
reader.GetValue<bool>(15),
$"{reader.GetValue<DateTimeOffset>(16):yyyy-MM-dd}",
reader.GetString(17).Replace(',', ' '),
reader.GetString(18).Replace(',', ' '),
reader.GetValue<int>(19),
$"{reader.GetValue<decimal>(20):0.000000000}",
},
columns => csvItems.Add(columns))
.ToList();
csvItems.AddRange(items);
var csvLines = csvItems.Select(x => string.Join(",", x));
var csvContent = string.Join(Environment.NewLine, csvLines);
return Encoding.UTF8.GetBytes(csvContent);
}
public IEnumerable<HeliumPressurePoint> LoadHeliumPressureResults(int testId)
=> this.sqlClient.ExecuteReader($@"
SELECT [CordonelPressureTestTestPoints_Id]
, [CordonelPressureTest_TestPointNr]
, CAST([CordonelPressureTest_TestPointResult] AS NUMERIC(9, 8))
FROM [Cordonel_PressureTest_TestPoints]
WHERE [CordonelPressureTest_Id] = @{nameof(testId)}",
parameters => parameters.Add(nameof(testId), testId),
reader => new HeliumPressurePoint
{
TestId = reader.GetValue<int>(0),
PointNr = reader.GetValue<int>(1),
Result = reader.GetValue<decimal>(2),
});
}
}