Roland Drabesch 0c3e28b8bd Mostly EOL and LUT Management 2022-08-10 17:06:09 +02:00
Thomas Wiedebusch bac97f8e57 BaseSerialPort:
- Flush buffer (DiscardInBuffer) removed as some bytes are missing from time to time.  The IrDA sniffer showed these on the communication line, but they are incompletely received.  Assuming the DiscardInBuffer may be delayed, so the incoming data will be scrapped.

IrdaTransmitProtocol:
- WakeUpMessage marked and debug output
2022-07-15 17:18:12 +02:00
Roland Drabesch 2f949f3f28 skelton key in pw file 2022-07-12 17:15:43 +02:00
Thomas Wiedebusch 8293dfc882 Extracted radio key from programming parameters for DEBUG 2022-06-17 08:30:24 +02:00
Thomas Wiedebusch f7e0f63125 FwUpdateBuilder: -Customer field can be changed manually to give the safe a different name and overcome the data base limitations of the naming field size and special characters,
FinalTest: - Layout slightly changed
PasswordController: - Debug varable introduced
2022-06-13 14:49:22 +02:00
Thomas Wiedebusch e45ddcfa5b FwUpdateBuilder:
- Improved speed for pre-build summary,
- only one FW-update package can be selected for one FW update safe,
- Pre-build summary fills the FW-package to all devices and validates it,
- Validation can be manually corrected / overwritten
2022-05-13 10:54:41 +02:00
Roland Drabesch b1adcd0d7f base classes and fake function created
wait for file format aproval
2022-04-29 09:58:45 +02:00
Thomas Wiedebusch 00cf24a93e MeterFile VerifyMeterFile return changed to false if file cannot be read 2022-04-21 17:37:50 +02:00
Roland Drabesch ad752435c1 release 2022-04-21 11:31:41 +02:00
Thomas Wiedebusch 9f8d315b8f MeterFile: VerifyMeterFile for binary compare of given file with file in Genesis Meter 2022-04-06 14:11:23 +02:00
Roland Drabesch 152e775310 merge done 2022-04-06 12:38:36 +02:00
Thomas Wiedebusch 56ef6731cd FwUpdateLoader: - Check order number, position and PcbId and parse report file to search for "Firmware up to date!" string to mark only successfully performed updates in the PcbId table on the main screen. This keeps the user informed of the status of the "Firmware Update Procedure", if the PcbId is check-marked, this has been successfully updated according to this update order number! 2021-10-15 08:01:23 +02:00