Thomas Wiedebusch
1076b608d5
MeterFwUpdate:
...
- Bugfix: Store config before display to "Idle" and "8888",
FwUpdateSw (CUST):
- Safe configurations on any connect to support this even if no update is required,
- Release display on any internal idle mode
2022-05-10 13:06:48 +02:00
Roland Drabesch
b1adcd0d7f
base classes and fake function created
...
wait for file format aproval
2022-04-29 09:58:45 +02:00
Thomas Wiedebusch
df68bf87d7
V 2.2.4
...
CUST:
FwUpdateSw:
- Released display changed
2022-04-28 10:24:05 +02:00
Thomas Wiedebusch
81635dc607
CUST 2.2.3 / GTB 2.2.3
...
GenesisMeter:
- Bugfix: access GENESISFLOW_LookupFileCrc for FW Versions below 1.2
2022-04-28 07:28:58 +02:00
Thomas Wiedebusch
62a07570ef
GTB 2.2.2.2
...
ReSharper run on GenesisMeter.cs
2022-04-26 21:21:14 +02:00
Thomas Wiedebusch
99e5550aed
GTB 2.2.2
...
Changed config file upload
2022-04-26 17:51:40 +02:00
Thomas Wiedebusch
e8ec68dee1
GTB 2.2.2:
...
FwUpdate can upload entire 0\\config file
2022-04-26 16:32:15 +02:00
Thomas Wiedebusch
63899401bb
MeterFwUpdate:
...
- renamed SetLoadedFiles to ValidateLoadedFiles,
- corrected return (was always true)
2022-04-22 07:30:00 +02:00
Thomas Wiedebusch
403f249e9b
GTB 2.2.1
...
- GenesisMeter: StoreAllConfigurations corrected, stores all calibrations and configurations, avoids read back of store-configuration on SENSUSRADIO as this returns NULL,
- FwUpdate: Executes StoreAllConfigurations before FwUpdate
2022-04-21 18:44:31 +02:00
Thomas Wiedebusch
00cf24a93e
MeterFile VerifyMeterFile return changed to false if file cannot be read
2022-04-21 17:37:50 +02:00
Roland Drabesch
ad752435c1
release
2022-04-21 11:31:41 +02:00
Thomas Wiedebusch
9f8d315b8f
MeterFile: VerifyMeterFile for binary compare of given file with file in Genesis Meter
2022-04-06 14:11:23 +02:00
Roland Drabesch
81e7e16653
revert merge and
2022-04-06 13:36:43 +02:00
Roland Drabesch
152e775310
merge done
2022-04-06 12:38:36 +02:00
Roland Drabesch
80c0b07305
Merge
...
Common\Hardware\WaterMeter\Genesis\GenesisFile\MeterFile.cs
2022-04-06 12:38:28 +02:00
Roland Drabesch
ec37bb9b9e
Long time no commit
2022-04-06 10:42:16 +02:00
Thomas Wiedebusch
1ff86d6f95
Improved LUT update process speed
2022-04-01 15:33:14 +02:00
Thomas Wiedebusch
8b9ccc17dd
MeterFile:
...
- Added '\0' string delimiter to file name, is essential for erase/write and read operation,
- Ignored return from file close write as it is often false and the following read returns a correct answer,
GenesisMeter:
- Removed doubled outputs
MeterRegisters:
- corrected parsing of registers
FrmLutUpdate:
- output of region and frequency,
MeterLutUpdate:
- For comparison of file content after reading back taking the different size of original and receive buffer, which is an integer division by 4, into account.
2022-04-01 14:22:54 +02:00
Thomas Wiedebusch
d95a85f0b7
Delays implemented between file access steps
2022-03-29 14:47:25 +02:00
Thomas Wiedebusch
50f15842aa
History window for additional information
2022-03-28 13:23:03 +02:00
Thomas Wiedebusch
c015b16f0a
changed sequencing of MeterLutUpdate - still not working: cannot set meter size or erase 1\\mettbl and 1\\mettbl_b
2022-03-04 11:15:00 +01:00
Thomas Wiedebusch
1ae56612ff
MeterFwUpdate and MeterLutUpdate:
...
- Introduced lock for repeated execution of state machine
2022-03-04 09:10:08 +01:00
Thomas Wiedebusch
63121d7c41
Verification of LUT files, upload and verify binary content
2022-03-04 08:16:14 +01:00
Thomas Wiedebusch
4d9186a322
LUT update improvements
2022-03-03 21:47:54 +01:00
Thomas Wiedebusch
a281e753c4
Initial version of LUT file write GTB2.2.0
2022-03-03 00:31:58 +01:00
Thomas Wiedebusch
14eda41bdd
Prepared for LUT downloading, IrDASerialPort changed
2022-03-02 14:24:47 +01:00
Thomas Wiedebusch
835f242d95
FwUpdateBuilder: -colored FW update safes: green are active, red are outdated, - colored FW update report output: - green if successful, else red
2021-10-30 12:24:10 +02:00
Thomas Wiedebusch
ae4dcf9fbc
FwUpdateBuilder: - Fw Update Sw taken from DB,- Configuration files taken from DB
2021-10-27 12:47:29 +02:00
Thomas Wiedebusch
56ef6731cd
FwUpdateLoader: - Check order number, position and PcbId and parse report file to search for "Firmware up to date!" string to mark only successfully performed updates in the PcbId table on the main screen. This keeps the user informed of the status of the "Firmware Update Procedure", if the PcbId is check-marked, this has been successfully updated according to this update order number!
2021-10-15 08:01:23 +02:00
Rowlander
d6c41b6b9f
now with better references
2021-10-04 09:36:33 +02:00
Rowlander
f0c8d0ecb1
clean commit
2021-10-04 09:19:09 +02:00
Thomas Wiedebusch
cfa3412996
First commit test
2021-10-01 12:58:11 +02:00
Rowlander
01e19098b4
5
2021-10-01 11:47:09 +02:00
Rowlander
ebf9fcd4a8
commit nr 3
2021-10-01 11:28:53 +02:00
Rowlander
9f4a54edc7
commit nr 2
2021-10-01 11:28:46 +02:00
Rowlander
fe54fceb1e
Initial commit
2021-10-01 11:09:20 +02:00