GenesisMeter: - support configuration check for 'B' labeled FW
This commit is contained in:
@@ -1,5 +1,6 @@
|
||||
using Logic.ProductionToProductMapper.Cordonel;
|
||||
using Newtonsoft.Json;
|
||||
using NLog;
|
||||
using System;
|
||||
using System.Collections.Concurrent;
|
||||
using System.Collections.Generic;
|
||||
@@ -14,7 +15,6 @@ using System.Text;
|
||||
using System.Text.RegularExpressions;
|
||||
using System.Threading;
|
||||
using System.Timers;
|
||||
using NLog;
|
||||
using Xylem.Common.CommonCore.Configuration;
|
||||
using Xylem.Common.CommonCore.Consts;
|
||||
using Xylem.Common.CommonCore.ThreadWatcher;
|
||||
@@ -49,6 +49,7 @@ using Xylem.Common.Metrology.Measurements;
|
||||
using Xylem.Common.Metrology.Measurements.Consts;
|
||||
using Xylem.Common.Utils.Logging;
|
||||
using Access = Xylem.Common.Hardware.WaterMeter.Genesis.Registers.Access;
|
||||
using Register = Xylem.Common.Hardware.WaterMeter.Genesis.Registers.Register;
|
||||
using Timer = System.Timers.Timer;
|
||||
|
||||
namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
@@ -1384,9 +1385,6 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
/// <remarks date="2023-Mar-08" author="Thomas Wiedebusch">
|
||||
/// - Removed the optional leading "B" or "R" on strVersion input to create the fwVersion.
|
||||
/// </remarks>
|
||||
/// <remarks date="2025-Sep-29" author="Thomas Wiedebusch">
|
||||
/// - Masked out the marker for "B" in msb input to create the fwVersion.
|
||||
/// </remarks>
|
||||
public static String BuildFlexnetFwVersion(out UInt32 fwVersion, String strVersion, Byte? msb = null,
|
||||
Byte? lsb = null)
|
||||
{
|
||||
@@ -1406,8 +1404,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
minor = (Int32)(msb & 0x0F);
|
||||
builtMajor = (Int32)((lsb & 0xF0) >> 4);
|
||||
builtMinor = (Int32)(lsb & 0x0F);
|
||||
// mask out the "B" marker 0111 1111
|
||||
fwVersion = (UInt32)(((msb & 0x7F) << 8) + lsb);
|
||||
fwVersion = (UInt32)(((msb & 0xFF) << 8) + lsb);
|
||||
}
|
||||
else if (!string.IsNullOrEmpty(strVersion))
|
||||
{
|
||||
@@ -1720,6 +1717,9 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
/// AppId 256, which exceeds the byte range as this isn't a real application, but will be used to identify
|
||||
/// the interface (configuration.json) version.
|
||||
/// </remarks>
|
||||
/// <remarks date="2025-Sep-30" author="Thomas Wiedebusch">
|
||||
/// - Mask out the 'B' marker (0x8000) as 'configuration.json' states only the 'R' version.
|
||||
/// </remarks>
|
||||
protected virtual void ReadMeterFirmwareAndAssignRegisters()
|
||||
{
|
||||
// Avoid overwriting of list if this already exits
|
||||
@@ -1749,11 +1749,15 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
InterfaceVersion = BuildFwVersionStringFromDec(meterApp.AppVersion);
|
||||
// Build the max supported versions for EMEA and NA to check the supported FW
|
||||
if (Region.Equals("EMEA"))
|
||||
InterfaceMaxFwVersion = BuildFlexnetFwVersion(out interfaceMaxEmeaVersion,
|
||||
{
|
||||
InterfaceMaxFwVersion = BuildFlexnetFwVersion(out interfaceMaxEmeaVersion,
|
||||
meterApp.InterfaceMaxEmeaVersion);
|
||||
}
|
||||
if (Region.Equals("NA"))
|
||||
InterfaceMaxFwVersion = BuildFlexnetFwVersion(out interfaceMaxNaVersion,
|
||||
{
|
||||
InterfaceMaxFwVersion = BuildFlexnetFwVersion(out interfaceMaxNaVersion,
|
||||
meterApp.InterfaceMaxNaVersion);
|
||||
}
|
||||
continue;
|
||||
}
|
||||
|
||||
@@ -1778,7 +1782,8 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
FwVersion = BuildFlexnetFwVersion(out readFwVersion, null, readFwVersionBytes[1],
|
||||
readFwVersionBytes[0]);
|
||||
versionString = FwVersion;
|
||||
InstalledFwVersion = readFwVersion;
|
||||
// Mask out the 'B' marker (0x8000) as 'configuration.json' states only the 'R' version
|
||||
InstalledFwVersion = readFwVersion & 0x7FFF;
|
||||
}
|
||||
else
|
||||
{
|
||||
|
||||