@@ -70,7 +70,7 @@ namespace XYLEM.Device
|
||||
/// <returns>true on okay or false on error</returns>
|
||||
Boolean SetSensorSerialNo(UInt32 new_serial_number);
|
||||
|
||||
/// <summary>out UInt16
|
||||
/// <summary>
|
||||
/// Unique-ID for the MagFlux electronics
|
||||
/// </summary>
|
||||
/// <param name="value_out">a hex decimal string 0x1234ABCDEF or NULL at error</param>
|
||||
|
||||
@@ -1,5 +1,5 @@
|
||||
/* @page Declaration for "Gluing" Metrology Modbus API in to Application
|
||||
* AUTO GENERATED DON'T EDIT, IS GENERATED WITH "MagFlux6200_metrology_reg_listvX.py @ 2023_08_11__08_35"
|
||||
* AUTO GENERATED DON'T EDIT, IS GENERATED WITH "MagFlux6200_metrology_reg_listvX.py @ 2023_10_19__08_34"
|
||||
* From: https://bitbucket.org/xyleminc/magflux_modbus_registers/src/main/Registers/
|
||||
*/
|
||||
|
||||
@@ -35,7 +35,7 @@ namespace MagFlux6200_metrology_reg_list
|
||||
/// @brief Version number of Metrology register list.
|
||||
/// The md_master_csharp_6200_reg_list.cs files were created from this version
|
||||
/// </summary>
|
||||
public int Version { get { return 43; } }
|
||||
public int Version { get { return 46; } }
|
||||
|
||||
/// <summary>
|
||||
/// Variable name
|
||||
@@ -135,6 +135,11 @@ namespace MagFlux6200_metrology_reg_list
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_U32MdbsRegsVer = new Device_value("Met_U32MdbsRegsVer", 19, ValueDataType.U32, ValueRW_Type.ReadWrite, "Programmed during JTAG with firmware. Const after production.");
|
||||
|
||||
/// <summary>
|
||||
/// @brief Tells you what calibration method was used. 0 is default, for calibration on flow rig for 5 min per point
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_U16CalibrationVersion = new Device_value("Met_U16CalibrationVersion", 21, ValueDataType.U16, ValueRW_Type.ReadWrite, "Tells you what calibration method was used. 0 is default, for calibration on flow rig for 5 min per point");
|
||||
|
||||
|
||||
/*------------------------------ block number 1 ------------------------------*/
|
||||
|
||||
@@ -847,7 +852,7 @@ namespace MagFlux6200_metrology_reg_list
|
||||
/// <summary>
|
||||
/// @brief Tick count, for ADC data sample
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_U32IntADCSample_battADC_scale = new Device_value("Met_U32IntADCSample_battADC_scale", 3302, ValueDataType.F32, ValueRW_Type.ReadWrite, "Tick count, for ADC data sample");
|
||||
internal static readonly Device_value Met_F32IntADCSample_battADC_scale = new Device_value("Met_F32IntADCSample_battADC_scale", 3302, ValueDataType.F32, ValueRW_Type.ReadWrite, "Tick count, for ADC data sample");
|
||||
|
||||
/// <summary>
|
||||
/// @brief Int. ADC value: diag_p_adc as Voltage
|
||||
@@ -857,7 +862,7 @@ namespace MagFlux6200_metrology_reg_list
|
||||
/// <summary>
|
||||
/// @brief Tick count, for ADC data sample
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_U32IntADCSample_diagP_adc_scale = new Device_value("Met_U32IntADCSample_diagP_adc_scale", 3306, ValueDataType.F32, ValueRW_Type.ReadWrite, "Tick count, for ADC data sample");
|
||||
internal static readonly Device_value Met_F32IntADCSample_diagP_adc_scale = new Device_value("Met_F32IntADCSample_diagP_adc_scale", 3306, ValueDataType.F32, ValueRW_Type.ReadWrite, "Tick count, for ADC data sample");
|
||||
|
||||
/// <summary>
|
||||
/// @brief Int. ADC value: diag_n_adc as Voltage
|
||||
@@ -867,7 +872,7 @@ namespace MagFlux6200_metrology_reg_list
|
||||
/// <summary>
|
||||
/// @brief Tick count, for ADC data sample
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_U32IntADCSample_diagN_adc_scale = new Device_value("Met_U32IntADCSample_diagN_adc_scale", 3310, ValueDataType.F32, ValueRW_Type.ReadWrite, "Tick count, for ADC data sample");
|
||||
internal static readonly Device_value Met_F32IntADCSample_diagN_adc_scale = new Device_value("Met_F32IntADCSample_diagN_adc_scale", 3310, ValueDataType.F32, ValueRW_Type.ReadWrite, "Tick count, for ADC data sample");
|
||||
|
||||
/// <summary>
|
||||
/// @brief Int. ADC value: diag_c_adc as Voltage
|
||||
@@ -877,7 +882,7 @@ namespace MagFlux6200_metrology_reg_list
|
||||
/// <summary>
|
||||
/// @brief Tick count, for ADC data sample
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_U32IntADCSample_diagC_adc_scale = new Device_value("Met_U32IntADCSample_diagC_adc_scale", 3314, ValueDataType.F32, ValueRW_Type.ReadWrite, "Tick count, for ADC data sample");
|
||||
internal static readonly Device_value Met_F32IntADCSample_diagC_adc_scale = new Device_value("Met_F32IntADCSample_diagC_adc_scale", 3314, ValueDataType.F32, ValueRW_Type.ReadWrite, "Tick count, for ADC data sample");
|
||||
|
||||
/// <summary>
|
||||
/// @brief Int. ADC value: vref_common_adc as Voltage
|
||||
@@ -887,7 +892,7 @@ namespace MagFlux6200_metrology_reg_list
|
||||
/// <summary>
|
||||
/// @brief Tick count, for ADC data sample
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_U32IntADCSample_vrefCommonADC_scale = new Device_value("Met_U32IntADCSample_vrefCommonADC_scale", 3318, ValueDataType.F32, ValueRW_Type.ReadWrite, "Tick count, for ADC data sample");
|
||||
internal static readonly Device_value Met_F32IntADCSample_vrefCommonADC_scale = new Device_value("Met_F32IntADCSample_vrefCommonADC_scale", 3318, ValueDataType.F32, ValueRW_Type.ReadWrite, "Tick count, for ADC data sample");
|
||||
|
||||
/// <summary>
|
||||
/// @brief Int. ADC value: vref_adc as Voltage
|
||||
@@ -897,7 +902,7 @@ namespace MagFlux6200_metrology_reg_list
|
||||
/// <summary>
|
||||
/// @brief Tick count, for ADC data sample
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_U32IntADCSample_vrefADC_scale = new Device_value("Met_U32IntADCSample_vrefADC_scale", 3322, ValueDataType.F32, ValueRW_Type.ReadWrite, "Tick count, for ADC data sample");
|
||||
internal static readonly Device_value Met_F32IntADCSample_vrefADC_scale = new Device_value("Met_F32IntADCSample_vrefADC_scale", 3322, ValueDataType.F32, ValueRW_Type.ReadWrite, "Tick count, for ADC data sample");
|
||||
|
||||
/// <summary>
|
||||
/// @brief Int. ADC value: temperature_Cdiv10_adc as Voltage
|
||||
@@ -907,7 +912,7 @@ namespace MagFlux6200_metrology_reg_list
|
||||
/// <summary>
|
||||
/// @brief Tick count, for ADC data sample
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_U32IntADCSample_temperature_C_scale = new Device_value("Met_U32IntADCSample_temperature_C_scale", 3326, ValueDataType.F32, ValueRW_Type.ReadWrite, "Tick count, for ADC data sample");
|
||||
internal static readonly Device_value Met_F32IntADCSample_temperature_C_scale = new Device_value("Met_F32IntADCSample_temperature_C_scale", 3326, ValueDataType.F32, ValueRW_Type.ReadWrite, "Tick count, for ADC data sample");
|
||||
|
||||
/// <summary>
|
||||
/// @brief Int. ADC value: int_batt_adc as Voltage
|
||||
@@ -917,7 +922,7 @@ namespace MagFlux6200_metrology_reg_list
|
||||
/// <summary>
|
||||
/// @brief Tick count, for ADC data sample
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_U32IntADCSample_intBattADC_scale = new Device_value("Met_U32IntADCSample_intBattADC_scale", 3330, ValueDataType.F32, ValueRW_Type.ReadWrite, "Tick count, for ADC data sample");
|
||||
internal static readonly Device_value Met_F32IntADCSample_intBattADC_scale = new Device_value("Met_F32IntADCSample_intBattADC_scale", 3330, ValueDataType.F32, ValueRW_Type.ReadWrite, "Tick count, for ADC data sample");
|
||||
|
||||
|
||||
/*------------------------------ block number 19 ------------------------------*/
|
||||
@@ -1118,6 +1123,89 @@ namespace MagFlux6200_metrology_reg_list
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_U16ExcessFlowTimeThresh_s = new Device_value("Met_U16ExcessFlowTimeThresh_s", 7206, ValueDataType.U16, ValueRW_Type.ReadWrite, "micro-litres per second below which we let it go.");
|
||||
|
||||
|
||||
/*------------------------------ block number 27 ------------------------------*/
|
||||
|
||||
/// <summary>
|
||||
/// @brief Only uneven number allowed Changes will dynamic change Met_U16_...OnOffAvr_Max and Met_U16_...OnOffAvr
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_U16_FlowMedian_NoTapsReq = new Device_value("Met_U16_FlowMedian_NoTapsReq", 7220, ValueDataType.U16, ValueRW_Type.ReadWrite, "Only uneven number allowed Changes will dynamic change Met_U16_...OnOffAvr_Max and Met_U16_...OnOffAvr");
|
||||
|
||||
/// <summary>
|
||||
/// @brief Minimum value limit for Met_U16...NoTapsReq
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_U16_FlowMedian_NoTapsReq_Min = new Device_value("Met_U16_FlowMedian_NoTapsReq_Min", 7221, ValueDataType.U16, ValueRW_Type.ReadWrite, "Minimum value limit for Met_U16...NoTapsReq");
|
||||
|
||||
/// <summary>
|
||||
/// @brief Maximum value limit for Met_U16...NoTapsReq
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_U16_FlowMedian_NoTapsReq_Max = new Device_value("Met_U16_FlowMedian_NoTapsReq_Max", 7222, ValueDataType.U16, ValueRW_Type.ReadWrite, "Maximum value limit for Met_U16...NoTapsReq");
|
||||
|
||||
/// <summary>
|
||||
/// @brief 0:Passthrough, n: No. Central values. (default: 1) Will dynamic change, if Met_U16...OnOffAvr_Max changes to lower value.
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_U16_FlowMedian_OnOffAvr = new Device_value("Met_U16_FlowMedian_OnOffAvr", 7223, ValueDataType.U16, ValueRW_Type.ReadWrite, "0:Passthrough, n: No. Central values. (default: 1) Will dynamic change, if Met_U16...OnOffAvr_Max changes to lower value.");
|
||||
|
||||
/// <summary>
|
||||
/// @brief Minimum value limit for Met_U16...OnOffAvr
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_U16_FlowMedian_OnOffAvr_Min = new Device_value("Met_U16_FlowMedian_OnOffAvr_Min", 7224, ValueDataType.U16, ValueRW_Type.ReadWrite, "Minimum value limit for Met_U16...OnOffAvr");
|
||||
|
||||
/// <summary>
|
||||
/// @brief Maximum value limit for Met_U16...OnOffAvr Max is Dynamic changed and defined as (Met_U16...NoTapsReq - 2)
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_U16_FlowMedian_OnOffAvr_Max = new Device_value("Met_U16_FlowMedian_OnOffAvr_Max", 7225, ValueDataType.U16, ValueRW_Type.ReadWrite, "Maximum value limit for Met_U16...OnOffAvr Max is Dynamic changed and defined as (Met_U16...NoTapsReq - 2)");
|
||||
|
||||
/// <summary>
|
||||
/// @brief 0:No options, 1:max-min based, 2:Running stdev based
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_U16_FlowMedian_Options = new Device_value("Met_U16_FlowMedian_Options", 7226, ValueDataType.U16, ValueRW_Type.ReadWrite, "0:No options, 1:max-min based, 2:Running stdev based");
|
||||
|
||||
/// <summary>
|
||||
/// @brief Minimum limit allowed for Met_U16...Options
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_U16_FlowMedian_Options_Min = new Device_value("Met_U16_FlowMedian_Options_Min", 7227, ValueDataType.U16, ValueRW_Type.ReadWrite, "Minimum limit allowed for Met_U16...Options");
|
||||
|
||||
/// <summary>
|
||||
/// @brief Maximum limit allowed for Met_U16...Options
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_U16_FlowMedian_Options_Max = new Device_value("Met_U16_FlowMedian_Options_Max", 7228, ValueDataType.U16, ValueRW_Type.ReadWrite, "Maximum limit allowed for Met_U16...Options");
|
||||
|
||||
/// <summary>
|
||||
/// @brief Version of the median filter implementation
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_U16_FlowMedian_Version = new Device_value("Met_U16_FlowMedian_Version", 7229, ValueDataType.U16, ValueRW_Type.ReadWrite, "Version of the median filter implementation");
|
||||
|
||||
/// <summary>
|
||||
/// @brief 0 is ok, 1 is interesting like starting up etc., 2 is interesting - like EPD blanking ... all TBD
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_U16_FlowMedian_Status = new Device_value("Met_U16_FlowMedian_Status", 7230, ValueDataType.U16, ValueRW_Type.ReadWrite, "0 is ok, 1 is interesting like starting up etc., 2 is interesting - like EPD blanking ... all TBD");
|
||||
|
||||
/// <summary>
|
||||
/// @brief Time in seconds in the filter. Easily calculated from the current flip rate * number of taps, but may be useful.
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_F32_FlowMedian_TimeInFilter_s = new Device_value("Met_F32_FlowMedian_TimeInFilter_s", 7231, ValueDataType.F32, ValueRW_Type.ReadWrite, "Time in seconds in the filter. Easily calculated from the current flip rate * number of taps, but may be useful.");
|
||||
|
||||
/// <summary>
|
||||
/// @brief Central Filter value
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_F32_FlowMedian_CentralValue = new Device_value("Met_F32_FlowMedian_CentralValue", 7233, ValueDataType.F32, ValueRW_Type.ReadWrite, "Central Filter value");
|
||||
|
||||
/// <summary>
|
||||
/// @brief Maximum Filter value
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_F32_FlowMedian_MaxValue = new Device_value("Met_F32_FlowMedian_MaxValue", 7235, ValueDataType.F32, ValueRW_Type.ReadWrite, "Maximum Filter value");
|
||||
|
||||
/// <summary>
|
||||
/// @brief Minimum Filter value
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_F32_FlowMedian_MinValue = new Device_value("Met_F32_FlowMedian_MinValue", 7237, ValueDataType.F32, ValueRW_Type.ReadWrite, "Minimum Filter value");
|
||||
|
||||
/// <summary>
|
||||
/// @brief Usually something like ((max-min)/(0.001*Q3)) but may be something else TBD.
|
||||
/// </summary>
|
||||
internal static readonly Device_value Met_F32_FlowMedian_NoiseMeasure = new Device_value("Met_F32_FlowMedian_NoiseMeasure", 7239, ValueDataType.F32, ValueRW_Type.ReadWrite, "Usually something like ((max-min)/(0.001*Q3)) but may be something else TBD.");
|
||||
|
||||
} // End of reg_list
|
||||
/*---------------------------------------------------------------------------*/
|
||||
} /* MagFlux6200_metrology_reg_list */
|
||||
|
||||