CUST:
FwUpdateSw:
- Released display changed
This commit is contained in:
Thomas Wiedebusch
2022-04-28 10:24:05 +02:00
parent 81635dc607
commit df68bf87d7
11 changed files with 160 additions and 133 deletions
@@ -90,6 +90,9 @@
<Reference Include="System.Xml" />
</ItemGroup>
<ItemGroup>
<Compile Include="..\..\..\Common\.shared\SharedAssemblyInfo.cs">
<Link>Properties\SharedAssemblyInfo.cs</Link>
</Compile>
<Compile Include="Const\ProcessState.cs" />
<Compile Include="FrmFwUpdateBuilder.cs">
<SubType>Form</SubType>
@@ -113,7 +116,6 @@
<Compile Include="CordonelFwPackageInfo.cs" />
<Compile Include="Program.cs" />
<Compile Include="Properties\AssemblyInfo.cs" />
<Compile Include="Properties\SharedAssemblyInfo.cs" />
<EmbeddedResource Include="FrmFwUpdateBuilder.de.resx">
<DependentUpon>FrmFwUpdateBuilder.cs</DependentUpon>
<SubType>Designer</SubType>
@@ -1,18 +0,0 @@
using System.Reflection;
//#if DEBUG
//[assembly: AssemblyConfiguration("DEBUG")]
//#else
//[assembly: AssemblyConfiguration("RELEASE")]
//#endif
//[assembly: AssemblyCompany("Sensus")]
//[assembly: AssemblyProduct("Sensus WaterMeter Genesis")]
//[assembly: AssemblyCopyright("Copyright © Sensus 2020")]
//[assembly: AssemblyTrademark("WaterMeter Genesis")]
//
//[assembly: AssemblyVersion("1.2.*.0")]
[assembly: AssemblyVersion("2.2.3.*")]
[assembly: AssemblyFileVersion("2.2.3.0")]
@@ -90,6 +90,9 @@
<Reference Include="System.Xml" />
</ItemGroup>
<ItemGroup>
<Compile Include="..\..\..\Common\.shared\SharedAssemblyInfo.cs">
<Link>Properties\SharedAssemblyInfo.cs</Link>
</Compile>
<Compile Include="Const\ProcessState.cs" />
<Compile Include="FrmFwUpdateLoader.cs">
<SubType>Form</SubType>
@@ -105,7 +108,6 @@
</Compile>
<Compile Include="Program.cs" />
<Compile Include="Properties\AssemblyInfo.cs" />
<Compile Include="Properties\SharedAssemblyInfo.cs" />
<EmbeddedResource Include="FrmFwUpdateLoader.de.resx">
<DependentUpon>FrmFwUpdateLoader.cs</DependentUpon>
</EmbeddedResource>
@@ -1,18 +0,0 @@
using System.Reflection;
//#if DEBUG
//[assembly: AssemblyConfiguration("DEBUG")]
//#else
//[assembly: AssemblyConfiguration("RELEASE")]
//#endif
//[assembly: AssemblyCompany("Sensus")]
//[assembly: AssemblyProduct("Sensus WaterMeter Genesis")]
//[assembly: AssemblyCopyright("Copyright © Sensus 2020")]
//[assembly: AssemblyTrademark("WaterMeter Genesis")]
//
//[assembly: AssemblyVersion("1.2.*.0")]
[assembly: AssemblyVersion("2.2.3.*")]
[assembly: AssemblyFileVersion("2.2.3.0")]
@@ -0,0 +1,13 @@
set REL_SRC_PATH=bin\Release
set ABS_DEST_PATH=c:\Users\%USERNAME%\Downloads\ServiceFwUpdateSw
mkdir "%ABS_DEST_PATH%"
mkdir "%ABS_DEST_PATH%\de"
copy "%REL_SRC_PATH%\de\*" "%ABS_DEST_PATH%\de\"
copy "%REL_SRC_PATH%\*.dll" "%ABS_DEST_PATH%\"
copy "%REL_SRC_PATH%\configuration.json" "%ABS_DEST_PATH%\"
copy "%REL_SRC_PATH%\MeterFilesEraseRestore.json" "%ABS_DEST_PATH%\"
copy "%REL_SRC_PATH%\NlogConfig.xml" "%ABS_DEST_PATH%\"
@@ -302,7 +302,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
// this step can be skipped.
if (_registerRestorer != null && _registerRestorer.RegisterRestoreExecuted())
_processState = ProcessState.ReadPostUpdateMeterFiles;
else RegisterRestore(ProcessState.ReadPostUpdateMeterFiles);
else
RegisterRestore(ProcessState.ReadPostUpdateMeterFiles);
break;
case ProcessState.PortScan:
@@ -316,7 +317,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
// skipped to avoid erasure of successfully downloaded upgXX - Files!
if (_registerRestorer != null && _registerRestorer.RegisterBackupExecuted())
_processState = ProcessState.ReadPreUpdateMeterFiles;
else RegisterBackup(ProcessState.ReadInitialMeterFiles);
else
RegisterBackup(ProcessState.ReadInitialMeterFiles);
break;
case ProcessState.ReadMeterFilesConfig:
@@ -451,7 +453,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
case ProcessState.PwdFileRestore:
case ProcessState.Connect:
// these routines do not have an event callback handler
if (_progressBarValueCounter++ > 100) _progressBarValueCounter = 0;
if (_progressBarValueCounter++ > 100)
_progressBarValueCounter = 0;
UiInvoker.ProgressBarInvoker(barOverallProgressUpdate, _progressBarValueCounter);
break;
@@ -479,7 +482,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
break;
}
if (_timerDisplayOn) UpdateTimeDisplay();
if (_timerDisplayOn)
UpdateTimeDisplay();
}
/// <summary>
@@ -614,9 +618,13 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
/// <remarks date="2020-Nov-30" author="Thomas Wiedebusch">
/// - Initial
/// </remarks>
/// <remarks date="2022-Apr-28" author="Thomas Wiedebusch">
/// - Release display to normal operation,
/// - switch measurement LED off.
/// </remarks>
private void DisposeGenesis()
{
_currentGenesis?.Logout();
ReleaseDisplay();
// Batch removal disposes the meter!
_meterBatch?.RemoveAllMeters();
_currentGenesis = null;
@@ -678,7 +686,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
{
_frmHistory.rtbHistory.Invoke(new Action(() => { _frmHistory.rtbHistory.Clear(); }));
}
else _frmHistory?.rtbHistory.Clear();
else
_frmHistory?.rtbHistory.Clear();
}
@@ -718,24 +727,20 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
}
/// <summary>
/// Finalize update and clean up.
/// Finalize update and clean up. Bring the display back to normal operation and switch the LED off.
/// </summary>
/// <remarks date="2020-Dec-17" author="Thomas Wiedebusch">
/// - Added LED off.
/// </remarks>
/// <remarks date="2022-Apr-28" author="Thomas Wiedebusch">
/// - Login before display back to normal operation.
/// </remarks>
private void FrmFwUpdate_FormClosing(Object sender, FormClosingEventArgs e)
{
// Set LCD DISPLAY from IdLE and 8888 back to operation, this may be necessary if the update has been
// interrupted by a program stop due to a power loss or any unpredictable event.
_currentGenesis?.SetLcdText(true, new Byte[] { 0, 0, 0, 0 });
// deactivate LED, not needed to get measurements during the update or on repeated start after system
// failure. This overwrites the settings in _meterFwUpdate.
_currentGenesis?.WriteRegister(Register.Genesisflow.LedMode, new[] { (Byte)LedMode.Off });
ReleaseDisplay();
_frmHistory?.Close();
_processToken?.Cancel();
_currentGenesis?.Logout();
// this additionally disposes all meters
_meterBatch?.RemoveAllMeters();
_meterBatch?.Dispose();
@@ -874,7 +879,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
Thread.CurrentThread.CurrentUICulture = _cultureInfo;
Thread.CurrentThread.CurrentCulture = _cultureInfo;
if (_meterFwUpdate == null) return;
if (_meterFwUpdate == null)
return;
foreach (DataGridViewRow dataGridRow in gridViewApplic.Rows)
{
var testString = dataGridRow.Cells[Resources.StrTableStatus].Value.ToString();
@@ -950,7 +956,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
Thread.CurrentThread.CurrentUICulture = _cultureInfo;
Thread.CurrentThread.CurrentCulture = _cultureInfo;
if (_meterFwUpdate == null) _meterFwUpdate = new MeterFwUpdate(_currentGenesis);
if (_meterFwUpdate == null)
_meterFwUpdate = new MeterFwUpdate(_currentGenesis);
_binaryPackageLoaded = false;
try
@@ -1302,7 +1309,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
// if the Genesis/Cordonel has been already detected, the port scan can be bypassed
if (_currentGenesis != null && !string.IsNullOrEmpty(_currentGenesis.PcbId))
_processState = ProcessState.Connect;
else _processState = ProcessState.PortScan;
else
_processState = ProcessState.PortScan;
}
/// <summary>
@@ -1347,7 +1355,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
private void BtnUpdateFw_Click(Object sender, EventArgs e)
{
if (_currentGenesis == null || _meterFwUpdate?.FileApps == null ||
_registerRestorer == null) return;
_registerRestorer == null)
return;
_startTime = DateTimeOffset.UtcNow;
_resetTimeMeasurement = false;
@@ -1364,7 +1373,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
{
var xPosition = Location.X + Size.Width;
var yPosition = Location.Y;
if (_frmHistory == null) return;
if (_frmHistory == null)
return;
if (_frmHistory.Visible)
{
_frmHistory.Hide();
@@ -1382,6 +1392,24 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
#endregion --------------------------------------- User Interaction -------------------------------------------
#region ------------------------------------------ Tools ------------------------------------------------------
/// <summary>
/// Release display and switch measurement LED off..
/// </summary>
/// <remarks date="2022-Apr-27" author="Thomas Wiedebusch">
/// - Initial.
/// </remarks>
private void ReleaseDisplay()
{
_currentGenesis?.ReLogin();
// Set LCD DISPLAY from IdLE and 9999 back to operation, this may be necessary if the update has been
// interrupted by a program stop due to a power loss or any unpredictable event.
_currentGenesis?.SetLcdText(true, new Byte[] { 0, 0, 0, 0 });
// deactivate LED, not needed to get measurements during the update or on repeated start after system
// failure. This overwrites the settings in _meterFwUpdate.
_currentGenesis?.WriteRegister(Register.Genesisflow.LedMode, new[] { (Byte)LedMode.Off });
_currentGenesis?.Logout();
}
/// <summary>
/// Logging of string lists.
/// </summary>
@@ -1407,7 +1435,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
/// </remarks>
private void LogInstalledMeterFw()
{
if (_currentGenesis == null) return;
if (_currentGenesis == null)
return;
LogText(StrSeparator);
LogText($"PCB ID: {_currentGenesis.PcbId}");
LogText($"{Resources.StrMessageSystemCoreRevision} {_currentGenesis.CoreRevision}");
@@ -1441,7 +1470,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
}
LogText(StrSeparator);
if (string.IsNullOrEmpty(_pathNameCordonelAppVersionFile)) return;
if (string.IsNullOrEmpty(_pathNameCordonelAppVersionFile))
return;
try
{
// Create new file as for report only one version is allowed
@@ -1517,7 +1547,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
/// </summary>
private void InfoWindowColoredText(String txtHistory, Color color)
{
if (_frmHistory?.rtbHistory == null) return;
if (_frmHistory?.rtbHistory == null)
return;
Invoke(new Action(() =>
{
_frmHistory.rtbHistory.SuspendLayout();
@@ -1539,7 +1570,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
/// </remarks>
private void ReportText(String txtHistory)
{
if (string.IsNullOrEmpty(_pathNameReportFile)) return;
if (string.IsNullOrEmpty(_pathNameReportFile))
return;
try
{
// Create new file or add to existing file
@@ -1566,7 +1598,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
/// </remarks>
private void InfoStatusUnknown(Control label, String msg, Boolean userTextOutput = false)
{
if (userTextOutput) LogText(msg);
if (userTextOutput)
LogText(msg);
UiInvoker.ControlInvoker(label, ColorUnknownStatus, msg);
}
@@ -1578,7 +1611,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
/// </remarks>
private void InfoProcessActive(Control label, String msg, Boolean log = true)
{
if (log) LogText(msg);
if (log)
LogText(msg);
UiInvoker.ControlInvoker(label, ColorOngoingProcess, msg);
}
@@ -1587,7 +1621,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
/// </summary>
private void InfoProcessSuccess(Control label, String msg, Boolean log = true)
{
if (log) LogSuccessText(msg);
if (log)
LogSuccessText(msg);
UiInvoker.ControlInvoker(label, ColorSuccess, $@"{SuccessSign} {msg}");
}
@@ -1772,11 +1807,15 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
errorState = ProcessState.Error;
breakState = ProcessState.Stop;
if (objects == null) return;
if (objects == null)
return;
if (objects.Count > 0 && objects[0] != null) successState = (ProcessState)objects[0];
if (objects.Count > 1 && objects[1] != null) errorState = (ProcessState)objects[1];
if (objects.Count > 2 && objects[2] != null) breakState = (ProcessState)objects[2];
if (objects.Count > 0 && objects[0] != null)
successState = (ProcessState)objects[0];
if (objects.Count > 1 && objects[1] != null)
errorState = (ProcessState)objects[1];
if (objects.Count > 2 && objects[2] != null)
breakState = (ProcessState)objects[2];
}
/// <summary>
@@ -1916,9 +1955,12 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
SetActualProgressDisplayOff();
SetDisableDownloadAndEnableConnect();
_resetTimeMeasurement = true;
if (_serialPortScanner != null) _serialPortScanner.StopPortScan = true;
if (_meterFwUpdate != null) _meterFwUpdate.StopUpdateProcess = true;
if (_registerRestorer != null) _registerRestorer.StopRegisterAccess = true;
if (_serialPortScanner != null)
_serialPortScanner.StopPortScan = true;
if (_meterFwUpdate != null)
_meterFwUpdate.StopUpdateProcess = true;
if (_registerRestorer != null)
_registerRestorer.StopRegisterAccess = true;
MessageBoxShow(Resources.StrUserStop, "Info", MessageBoxButtons.OK, MessageBoxIcon.Asterisk);
// take the invoker of the error state to generate the message and / or popup window
@@ -1975,7 +2017,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
}
OverallProcessUpdate(e);
if (e.ActualProcessPercent != null) ActualProcessUpdate(e);
if (e.ActualProcessPercent != null)
ActualProcessUpdate(e);
}
/// <summary>
@@ -1994,7 +2037,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
private void OverallProcessUpdate(ProcessExecEventArgs e)
{
UiInvoker.ControlInvoker(lblOverallProcess, ColorDefault, e.OverallProcessMessage);
if (e.OverallProcessPercent == null) return;
if (e.OverallProcessPercent == null)
return;
var progress = (Int32)e.OverallProcessPercent;
UiInvoker.ProgressBarInvoker(barOverallProgressUpdate, progress > 100 ? 100 : progress);
}
@@ -2015,7 +2059,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
private void ActualProcessUpdate(ProcessExecEventArgs e)
{
UiInvoker.ControlInvoker(lblActualProcess, ColorDefault, e.ActualProcessMessage);
if (e.ActualProcessPercent == null) return;
if (e.ActualProcessPercent == null)
return;
var progress = (Int32)e.ActualProcessPercent;
UiInvoker.ProgressBarInvoker(barActualProgressUpdate, progress > 100 ? 100 : progress);
}
@@ -2087,7 +2132,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
while (_bootDelayCtrMs < RebootTimeoutMs && string.IsNullOrEmpty(text))
{
if (!_timerIntervalExpired) continue;
if (!_timerIntervalExpired)
continue;
_timerIntervalExpired = false;
// internal communication delay to avoid overload of Cordonel
if (_bootDelayCtrMs % internalCommunicationDelayMs == 0)
@@ -2177,7 +2223,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
{
//initialize the port type if not read from file
_portType = "Xylem.Common.Hardware.Interfaces.Ports.SerialPorts.IrdaSerialPort";
if (_serialPortScanner == null) _serialPortScanner = new MeterPortScanner(_portType);
if (_serialPortScanner == null)
_serialPortScanner = new MeterPortScanner(_portType);
//set the process bars
SetOverallProgressDisplayOn();
SetControlsCommunicationActive();
@@ -2231,7 +2278,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
/// </remarks>
private void FinalizePortScanner(Boolean success, IReadOnlyList<Object> exitProcessStateObjects)
{
if (_serialPortScanner != null) _serialPortScanner.OnProcessUpdate -= ProcessUpdate_Event;
if (_serialPortScanner != null)
_serialPortScanner.OnProcessUpdate -= ProcessUpdate_Event;
ObjectsToProcessStates(exitProcessStateObjects, out var successExitState, out var errorExitState,
out var breakExitState);
@@ -2338,7 +2386,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
//assign register restorer or set new created Genesis to access the post update register restorer
if (_registerRestorer == null)
_registerRestorer = new RegisterRestorer(_currentGenesis);
else _registerRestorer.AssignGenesis(_currentGenesis);
else
_registerRestorer.AssignGenesis(_currentGenesis);
SetOverallProgressDisplayOn(Resources.StrConnecting);
}
@@ -2374,10 +2423,12 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
private Boolean ExecConnect()
{
// nothing to do if already logged in into meter
if (_currentGenesis.IsLoggedOn) return true;
if (_currentGenesis.IsLoggedOn)
return true;
//read out the PCB ID from water-meter to open the password container of this device
if (string.IsNullOrEmpty(_currentGenesis.PcbId)) _currentGenesis.GetPcbId();
if (string.IsNullOrEmpty(_currentGenesis.PcbId))
_currentGenesis.GetPcbId();
// search the PCB ID and extract password for login
String password = null;
@@ -2426,14 +2477,15 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
// wait that long, otherwise the Cordonel locks for 2s, 4s, 8s, 16s and so on on every retry!
Thread.Sleep(5000);
if (_currentGenesis.Login(skeletonKey)) return true;
if (_currentGenesis.Login(skeletonKey))
return true;
_processState = ProcessState.Error;
return false;
}
/// <summary>
/// Initialization of connect to water-meter.
/// Finalize of connection process to water-meter.
/// </summary>
/// <param name="success">successful execution</param>
/// <param name="exitProcessStateObjects">objects containing process states sorted success-, error-,
@@ -2510,14 +2562,7 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
InfoProcessFailed(null, Resources.StrPasswordFileNotInstalled);
}
// Set LCD DISPLAY from IdLE and 8888 back to operation, this may be necessary if the update has been
// interrupted by a program stop due to a power loss or any unpredictable event.
_currentGenesis.SetLcdText(true, new Byte[] { 0, 0, 0, 0 });
// deactivate LED, not needed to get measurements during the update or on repeated start after system
// failure. This overwrites the settings in _meterFwUpdate.
_currentGenesis.WriteRegister(Register.Genesisflow.LedMode, new[] { (Byte)LedMode.Off });
_currentGenesis.Logout();
ReleaseDisplay();
_meterFwUpdate?.AssignGenesis(_currentGenesis);
// if authentication succeeded, the cordonel port detection must have succeeded in advance,
@@ -2532,7 +2577,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
UiInvoker.ControlInvoker(lblCoreRevision, ColorDefault,
Resources.StrCoreRevision + @" " + _currentGenesis.CoreRevision);
// avoid report again on final login after update
if (!_finalLoginAfterUpdate && BuildReportFiles()) LogInstalledMeterFw();
if (!_finalLoginAfterUpdate && BuildReportFiles())
LogInstalledMeterFw();
_processState = successExitState;
// change first the process state, otherwise the timer may switch the bar on again
SetOverallProgressDisplayOff();
@@ -2624,7 +2670,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
/// </remarks>
private void FinalizeRegisterBackup(Boolean success, IReadOnlyList<Object> exitProcessStateObjects)
{
if (_registerRestorer != null) _registerRestorer.OnProcessUpdate -= ProcessUpdate_Event;
if (_registerRestorer != null)
_registerRestorer.OnProcessUpdate -= ProcessUpdate_Event;
ObjectsToProcessStates(exitProcessStateObjects, out var successExitState, out var errorExitState,
out var breakExitState);
@@ -2746,7 +2793,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
// read all meter files
var meterFile = new MeterFile(_currentGenesis);
if (_readMeterFiles == null) _readMeterFiles = new List<String>();
if (_readMeterFiles == null)
_readMeterFiles = new List<String>();
_readMeterFiles.Clear();
if (meterFile.ReadMeterFileCatalog(out var meterFilesDrive0, MeterFile.StrMeterDrive0,
@@ -2851,7 +2899,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
SetOverallProgressDisplayOn(Resources.StrFileErasing + eraseFile);
// here the real erase will be executed
if (!meterFile.UnlockEraseWriteMeterFile(eraseFile)) continue;
if (!meterFile.UnlockEraseWriteMeterFile(eraseFile))
continue;
if (meterFile.EraseMeterFile(eraseFile))
{
erasedMeterFiles.Add(eraseFile);
@@ -2926,7 +2975,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
SetOverallProgressDisplayOn(Resources.StrFileRestoring + restoreFile.Name);
// this is the restore execution
if (!meterFile.UnlockEraseWriteMeterFile(restoreFile.Name)) continue;
if (!meterFile.UnlockEraseWriteMeterFile(restoreFile.Name))
continue;
if (meterFile.CreateEmptyMeterFile(restoreFile.Name, restoreFile.ByteSize))
{
restoredMeterFiles.Add(restoreFile.Name);
@@ -2988,6 +3038,10 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
/// <remarks date="2021-Apr-26" author="Thomas Wiedebusch">
/// - Checked for password file not in update container.
/// </remarks>
/// <remarks date="2022-Apr-28" author="Thomas Wiedebusch">
/// - Release display to normal operation,
/// - switch measurement LED off.
/// </remarks>
private void PwdFileRestore(ProcessState successExitState, ProcessState errorExitState = ProcessState.Error)
{
// remind the invoker being able to generate error messages based on the last state
@@ -3028,31 +3082,32 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
_processState = ProcessState.Connect;
_passwordFileIsCorrupted = false;
InfoProcessSuccess(lblPasswordFileCheck, Resources.StrPasswordFileRestoreSucceeded);
_currentGenesis.Logout();
// change first the process state, otherwise the timer may switch the bar on again
SetOverallProgressDisplayOff();
return;
}
}
_currentGenesis?.Logout();
_currentGenesis.Logout();
}
// the password file is NOT in the password container
else
{
InfoProcessFailed(lblPasswordFileCheck, Resources.StrPasswordNotDelivered);
_processState = errorExitState;
// change first the process state, otherwise the timer may switch the bar on again
SetOverallProgressDisplayOff();
return;
}
ReleaseDisplay();
// change first the process state, otherwise the timer may switch the bar on again
SetOverallProgressDisplayOff();
return;
}
ReleaseDisplay();
InfoProcessFailed(lblPasswordFileCheck, Resources.StrPasswordFileRestoreFailed);
_processState = errorExitState;
// change first the process state, otherwise the timer may switch the bar on again
SetOverallProgressDisplayOff();
}
#endregion --------------------------------------- File Access ------------------------------------------------
#endregion --------------------------------------- File Access ------------------------------------------------
#region ------------------------------------------ Register Restorer ------------------------------------------
/// <summary>
@@ -3111,7 +3166,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
private Boolean ExecRegisterRestore()
{
var success = _registerRestorer.PostUpdateReadRegisters();
if (success) success = _registerRestorer.CompareRegisters();
if (success)
success = _registerRestorer.CompareRegisters();
return success;
}
@@ -3138,7 +3194,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
/// </remarks>
private void FinalizeRegisterRestore(Boolean success, IReadOnlyList<Object> exitProcessStateObjects)
{
if (_registerRestorer != null) _registerRestorer.OnProcessUpdate -= ProcessUpdate_Event;
if (_registerRestorer != null)
_registerRestorer.OnProcessUpdate -= ProcessUpdate_Event;
ObjectsToProcessStates(exitProcessStateObjects, out var successExitState, out var errorExitState,
out var breakExitState);
@@ -3256,7 +3313,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
/// </remarks>
private void FinalizeFwUpdate(Boolean success, IReadOnlyList<Object> exitProcessStateObjects)
{
if (_meterFwUpdate != null) _meterFwUpdate.OnProcessUpdate -= ProcessUpdate_Event;
if (_meterFwUpdate != null)
_meterFwUpdate.OnProcessUpdate -= ProcessUpdate_Event;
ObjectsToProcessStates(exitProcessStateObjects, out var successExitState, out var errorExitState,
out var breakExitState);
@@ -3364,7 +3422,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
/// </remarks>
private void RadioBtnEnglishLanguage_Click(Object sender, EventArgs e)
{
if (Thread.CurrentThread.CurrentCulture.Name == "en-GB") return;
if (Thread.CurrentThread.CurrentCulture.Name == "en-GB")
return;
_cultureInfo = new CultureInfo("en-GB");
ChangeLanguageControls();
}
@@ -3383,7 +3442,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
/// </remarks>
private void RadioBtnGermanLanguage_Click(Object sender, EventArgs e)
{
if (Thread.CurrentThread.CurrentCulture.Name == "de-DE") return;
if (Thread.CurrentThread.CurrentCulture.Name == "de-DE")
return;
_cultureInfo = new CultureInfo("de-DE");
ChangeLanguageControls();
}
@@ -1,18 +0,0 @@
using System.Reflection;
//#if DEBUG
//[assembly: AssemblyConfiguration("DEBUG")]
//#else
//[assembly: AssemblyConfiguration("RELEASE")]
//#endif
//[assembly: AssemblyCompany("Sensus")]
//[assembly: AssemblyProduct("Sensus WaterMeter Genesis")]
//[assembly: AssemblyCopyright("Copyright © Sensus 2020")]
//[assembly: AssemblyTrademark("WaterMeter Genesis")]
//
//[assembly: AssemblyVersion("1.2.*.0")]
[assembly: AssemblyVersion("2.2.3.*")]
[assembly: AssemblyFileVersion("2.2.3.0")]
@@ -101,6 +101,9 @@
<Reference Include="System.Xml" />
</ItemGroup>
<ItemGroup>
<Compile Include="..\..\..\Common\.shared\SharedAssemblyInfo.cs">
<Link>Properties\SharedAssemblyInfo.cs</Link>
</Compile>
<Compile Include="Const\ProcessState.cs" />
<Compile Include="FrmHistory.cs">
<SubType>Form</SubType>
@@ -115,7 +118,6 @@
<DependentUpon>FrmServiceFwUpdateSw.cs</DependentUpon>
</Compile>
<Compile Include="Properties\AssemblyInfo.cs" />
<Compile Include="Properties\SharedAssemblyInfo.cs" />
<EmbeddedResource Include="FrmHistory.de.resx">
<DependentUpon>FrmHistory.cs</DependentUpon>
</EmbeddedResource>
@@ -302,6 +304,9 @@
<ItemGroup>
<Folder Include="EventArguments\" />
</ItemGroup>
<ItemGroup>
<WCFMetadata Include="Connected Services\" />
</ItemGroup>
<Import Project="..\..\..\Common\Utils\UiInvokerShared\UiInvokerShared.projitems" Label="Shared" />
<Import Project="..\..\..\Common\Utils\UiLanguageControlShared\UiLanguageControlShared.projitems" Label="Shared" />
<Import Project="$(MSBuildToolsPath)\Microsoft.CSharp.targets" />