CUST - Register restorer removed unnecessary RadioAlarmMask resets

This commit is contained in:
Thomas Wiedebusch
2023-10-09 17:06:25 +02:00
parent 598099ae44
commit d38031a94e
3 changed files with 88 additions and 17 deletions
@@ -75,10 +75,9 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
{
new ProgrammingParameters("LOGGER_TriggerLogFlush", new Byte[] { 0x01 }),
new ProgrammingParameters("PERIODICLOG_ResetCounter", new Byte[] { 0x00 }),
new ProgrammingParameters("SENSUSRADIO_MainAlarmMask", new Byte[] { 0x00 }),
new ProgrammingParameters("SENSUSRADIO_ExtendedAlarmMask", new Byte[] { 0x00 }),
// System state 0xFF will force a storage of all parameters and reset, followed by system state 0x02
// for customer mode, the reset needs only a few milliseconds
// Attention logout-delay-login required after this step!
new ProgrammingParameters("SENSUSRADIO_SystemState", new Byte[] { 0xFF })
};
@@ -146,8 +145,10 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// </remarks>
public Boolean RegisterRestoreExecuted()
{
if (_currentGenesis == null) return false;
if (_currentGenesis.PcbId != _pcbIdPostUpdate) return false;
if (_currentGenesis == null)
return false;
if (_currentGenesis.PcbId != _pcbIdPostUpdate)
return false;
return _registersPostUpdate.MeterRegisterDic.Count > 0;
}
@@ -163,8 +164,10 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// </remarks>
public Boolean RegisterBackupExecuted()
{
if (_currentGenesis == null) return false;
if (_currentGenesis.PcbId != _pcbIdPreUpdate) return false;
if (_currentGenesis == null)
return false;
if (_currentGenesis.PcbId != _pcbIdPreUpdate)
return false;
return _registersPreUpdate.MeterRegisterDic.Count > 0;
}
@@ -177,7 +180,8 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// </remarks>
public Boolean RestoreRegisters()
{
if (_currentGenesis == null && _pcbIdPostUpdate != _pcbIdPreUpdate) return false;
if (_currentGenesis == null && _pcbIdPostUpdate != _pcbIdPreUpdate)
return false;
// write store configuration to all applications
_currentGenesis?.StoreAllConfigurations();
@@ -193,7 +197,8 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// </remarks>
public Boolean CompareRegisters()
{
if (_currentGenesis == null && _pcbIdPostUpdate != _pcbIdPreUpdate) return false;
if (_currentGenesis == null && _pcbIdPostUpdate != _pcbIdPreUpdate)
return false;
return true;
}
@@ -215,9 +220,11 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// </remarks>
public Boolean PostUpdateReadRegisters()
{
if (_currentGenesis == null) return false;
if (_currentGenesis == null)
return false;
// deny update of registers if already done
if (_pcbIdPostUpdate == _currentGenesis.PcbId) return false;
if (_pcbIdPostUpdate == _currentGenesis.PcbId)
return false;
_pcbIdPostUpdate = _currentGenesis.PcbId;
// clear the contents of the restore registers if the water meter backed up was not identical
if (_pcbIdPreUpdate != _pcbIdPostUpdate)
@@ -228,7 +235,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
// get the pre-defined dictionary
var meterRegisters = _currentGenesis.GetConfigRegistersDefinitions();
// logging registers amy have changed during update!
// logging registers may have changed during update!
_logRegNames.Clear();
// extract all registers which can be read and create two dictionary for before update to safe program
@@ -280,9 +287,11 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// </remarks>
public Boolean PreUpdateReadRegisters()
{
if (_currentGenesis == null) return false;
if (_currentGenesis == null)
return false;
// deny update of registers if already done
if (_pcbIdPreUpdate == _currentGenesis.PcbId) return false;
if (_pcbIdPreUpdate == _currentGenesis.PcbId)
return false;
// remind the PCB ID before update for comparison
_pcbIdPreUpdate = _currentGenesis.PcbId;
// get the pre-defined dictionary
@@ -348,13 +357,15 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// </remarks>
private Boolean ReadRegistersSet(MeterRegisters registers, ICollection<String> registerNames)
{
if (_currentGenesis == null) return false;
if (_currentGenesis == null)
return false;
StopRegisterAccess = false;
ActualRegisterCtr = 0;
// read values from Genesis
_currentGenesis.ReLogin();
if (!_currentGenesis.IsLoggedOn) return false;
if (!_currentGenesis.IsLoggedOn)
return false;
foreach (var regName in registerNames)
{
@@ -391,7 +402,8 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
overallProcessCtrPercent, actualProcessMsg));
}
if (StopRegisterAccess) break;
if (StopRegisterAccess)
break;
}
catch (Exception)
{
@@ -81,6 +81,7 @@
<Compile Include="FwUpdateCrypt.cs" />
<Compile Include="FwUpdateSafe.cs" />
<Compile Include="MeterRecovery\RecoveryRegisterItem.cs" />
<Compile Include="MeterRecovery\RecoverySettings.cs" />
<Compile Include="MeterRecovery\RegisterRecoveryAccess.cs" />
<Compile Include="PasswordContainer.cs" />
<Compile Include="Properties\AssemblyInfo.cs" />
@@ -0,0 +1,58 @@
using System;
using System.Collections.Generic;
namespace Xylem.ServiceFwUpdate.Common.FwUpdateSafe.MeterRecovery
{
/// <summary>
///
/// </summary>
[Serializable]
public class RecoverySettings
{
/// <summary>
/// Null if check in not necessary if is an number check it against the pcbid from meter
/// </summary>
public String PcbId;
/// <summary>
/// Radio frequency in MHz referenced a SENSUSRADIO AppId 0x10, Register FrequencyIndicator Id 0x05
/// values: default 433, minimum 433, maximum 868 or null if region is "NA" or if for all frequencies
/// </summary>
public Int32? RadioFrequencyMhz;
/// <summary>
/// Null till meter handles regions
/// </summary>
public String Region;
/// <summary>
/// Release string which is the FLEXNETVERSION
/// </summary>
public String Release;
/// <summary>
/// User name
/// </summary>
public String ApproverName;
/// <summary>
/// Null means not approved
/// </summary>
public DateTimeOffset? ApprovalDate;
/// <summary>
/// List of registers to recover
/// </summary>
public List<RecoveryRegisterItem> RecoveryRegisters;
/// <summary>
/// File name for this recovery register set
/// </summary>
/// <returns></returns>
public String GenerateFileName()
{
return $"{PcbId}_{Region}_{Release}.recovery";
}
}
}