CUST - Register restorer removed unnecessary RadioAlarmMask resets
This commit is contained in:
@@ -75,10 +75,9 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
{
|
||||
new ProgrammingParameters("LOGGER_TriggerLogFlush", new Byte[] { 0x01 }),
|
||||
new ProgrammingParameters("PERIODICLOG_ResetCounter", new Byte[] { 0x00 }),
|
||||
new ProgrammingParameters("SENSUSRADIO_MainAlarmMask", new Byte[] { 0x00 }),
|
||||
new ProgrammingParameters("SENSUSRADIO_ExtendedAlarmMask", new Byte[] { 0x00 }),
|
||||
// System state 0xFF will force a storage of all parameters and reset, followed by system state 0x02
|
||||
// for customer mode, the reset needs only a few milliseconds
|
||||
// Attention logout-delay-login required after this step!
|
||||
new ProgrammingParameters("SENSUSRADIO_SystemState", new Byte[] { 0xFF })
|
||||
};
|
||||
|
||||
@@ -146,8 +145,10 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
/// </remarks>
|
||||
public Boolean RegisterRestoreExecuted()
|
||||
{
|
||||
if (_currentGenesis == null) return false;
|
||||
if (_currentGenesis.PcbId != _pcbIdPostUpdate) return false;
|
||||
if (_currentGenesis == null)
|
||||
return false;
|
||||
if (_currentGenesis.PcbId != _pcbIdPostUpdate)
|
||||
return false;
|
||||
return _registersPostUpdate.MeterRegisterDic.Count > 0;
|
||||
}
|
||||
|
||||
@@ -163,8 +164,10 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
/// </remarks>
|
||||
public Boolean RegisterBackupExecuted()
|
||||
{
|
||||
if (_currentGenesis == null) return false;
|
||||
if (_currentGenesis.PcbId != _pcbIdPreUpdate) return false;
|
||||
if (_currentGenesis == null)
|
||||
return false;
|
||||
if (_currentGenesis.PcbId != _pcbIdPreUpdate)
|
||||
return false;
|
||||
return _registersPreUpdate.MeterRegisterDic.Count > 0;
|
||||
}
|
||||
|
||||
@@ -177,7 +180,8 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
/// </remarks>
|
||||
public Boolean RestoreRegisters()
|
||||
{
|
||||
if (_currentGenesis == null && _pcbIdPostUpdate != _pcbIdPreUpdate) return false;
|
||||
if (_currentGenesis == null && _pcbIdPostUpdate != _pcbIdPreUpdate)
|
||||
return false;
|
||||
|
||||
// write store configuration to all applications
|
||||
_currentGenesis?.StoreAllConfigurations();
|
||||
@@ -193,7 +197,8 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
/// </remarks>
|
||||
public Boolean CompareRegisters()
|
||||
{
|
||||
if (_currentGenesis == null && _pcbIdPostUpdate != _pcbIdPreUpdate) return false;
|
||||
if (_currentGenesis == null && _pcbIdPostUpdate != _pcbIdPreUpdate)
|
||||
return false;
|
||||
|
||||
return true;
|
||||
}
|
||||
@@ -215,9 +220,11 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
/// </remarks>
|
||||
public Boolean PostUpdateReadRegisters()
|
||||
{
|
||||
if (_currentGenesis == null) return false;
|
||||
if (_currentGenesis == null)
|
||||
return false;
|
||||
// deny update of registers if already done
|
||||
if (_pcbIdPostUpdate == _currentGenesis.PcbId) return false;
|
||||
if (_pcbIdPostUpdate == _currentGenesis.PcbId)
|
||||
return false;
|
||||
_pcbIdPostUpdate = _currentGenesis.PcbId;
|
||||
// clear the contents of the restore registers if the water meter backed up was not identical
|
||||
if (_pcbIdPreUpdate != _pcbIdPostUpdate)
|
||||
@@ -228,7 +235,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
|
||||
// get the pre-defined dictionary
|
||||
var meterRegisters = _currentGenesis.GetConfigRegistersDefinitions();
|
||||
// logging registers amy have changed during update!
|
||||
// logging registers may have changed during update!
|
||||
_logRegNames.Clear();
|
||||
|
||||
// extract all registers which can be read and create two dictionary for before update to safe program
|
||||
@@ -280,9 +287,11 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
/// </remarks>
|
||||
public Boolean PreUpdateReadRegisters()
|
||||
{
|
||||
if (_currentGenesis == null) return false;
|
||||
if (_currentGenesis == null)
|
||||
return false;
|
||||
// deny update of registers if already done
|
||||
if (_pcbIdPreUpdate == _currentGenesis.PcbId) return false;
|
||||
if (_pcbIdPreUpdate == _currentGenesis.PcbId)
|
||||
return false;
|
||||
// remind the PCB ID before update for comparison
|
||||
_pcbIdPreUpdate = _currentGenesis.PcbId;
|
||||
// get the pre-defined dictionary
|
||||
@@ -348,13 +357,15 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
/// </remarks>
|
||||
private Boolean ReadRegistersSet(MeterRegisters registers, ICollection<String> registerNames)
|
||||
{
|
||||
if (_currentGenesis == null) return false;
|
||||
if (_currentGenesis == null)
|
||||
return false;
|
||||
StopRegisterAccess = false;
|
||||
ActualRegisterCtr = 0;
|
||||
|
||||
// read values from Genesis
|
||||
_currentGenesis.ReLogin();
|
||||
if (!_currentGenesis.IsLoggedOn) return false;
|
||||
if (!_currentGenesis.IsLoggedOn)
|
||||
return false;
|
||||
|
||||
foreach (var regName in registerNames)
|
||||
{
|
||||
@@ -391,7 +402,8 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
overallProcessCtrPercent, actualProcessMsg));
|
||||
}
|
||||
|
||||
if (StopRegisterAccess) break;
|
||||
if (StopRegisterAccess)
|
||||
break;
|
||||
}
|
||||
catch (Exception)
|
||||
{
|
||||
|
||||
@@ -81,6 +81,7 @@
|
||||
<Compile Include="FwUpdateCrypt.cs" />
|
||||
<Compile Include="FwUpdateSafe.cs" />
|
||||
<Compile Include="MeterRecovery\RecoveryRegisterItem.cs" />
|
||||
<Compile Include="MeterRecovery\RecoverySettings.cs" />
|
||||
<Compile Include="MeterRecovery\RegisterRecoveryAccess.cs" />
|
||||
<Compile Include="PasswordContainer.cs" />
|
||||
<Compile Include="Properties\AssemblyInfo.cs" />
|
||||
|
||||
@@ -0,0 +1,58 @@
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
|
||||
namespace Xylem.ServiceFwUpdate.Common.FwUpdateSafe.MeterRecovery
|
||||
{
|
||||
/// <summary>
|
||||
///
|
||||
/// </summary>
|
||||
[Serializable]
|
||||
public class RecoverySettings
|
||||
{
|
||||
|
||||
/// <summary>
|
||||
/// Null if check in not necessary if is an number check it against the pcbid from meter
|
||||
/// </summary>
|
||||
public String PcbId;
|
||||
|
||||
/// <summary>
|
||||
/// Radio frequency in MHz referenced a SENSUSRADIO AppId 0x10, Register FrequencyIndicator Id 0x05
|
||||
/// values: default 433, minimum 433, maximum 868 or null if region is "NA" or if for all frequencies
|
||||
/// </summary>
|
||||
public Int32? RadioFrequencyMhz;
|
||||
|
||||
/// <summary>
|
||||
/// Null till meter handles regions
|
||||
/// </summary>
|
||||
public String Region;
|
||||
|
||||
/// <summary>
|
||||
/// Release string which is the FLEXNETVERSION
|
||||
/// </summary>
|
||||
public String Release;
|
||||
|
||||
/// <summary>
|
||||
/// User name
|
||||
/// </summary>
|
||||
public String ApproverName;
|
||||
|
||||
/// <summary>
|
||||
/// Null means not approved
|
||||
/// </summary>
|
||||
public DateTimeOffset? ApprovalDate;
|
||||
|
||||
/// <summary>
|
||||
/// List of registers to recover
|
||||
/// </summary>
|
||||
public List<RecoveryRegisterItem> RecoveryRegisters;
|
||||
|
||||
/// <summary>
|
||||
/// File name for this recovery register set
|
||||
/// </summary>
|
||||
/// <returns></returns>
|
||||
public String GenerateFileName()
|
||||
{
|
||||
return $"{PcbId}_{Region}_{Release}.recovery";
|
||||
}
|
||||
}
|
||||
}
|
||||
Reference in New Issue
Block a user