Logging extended with slot, prepared for hiding of sensible data in log-file (e.g. needed for encryption key)

This commit is contained in:
Thomas Wiedebusch
2023-09-01 15:07:37 +02:00
parent 863354cc9f
commit ca7f28b6e7
10 changed files with 128 additions and 89 deletions
@@ -20,11 +20,11 @@ namespace Xylem.Common.Hardware.Interfaces.Protocols.TransmitProtocol
public abstract void SetDefaultResponseTimeout(); public abstract void SetDefaultResponseTimeout();
public abstract List<Byte> DecodeDataForPhysicalLayer(Byte command, Byte[] payload, Boolean hideDateInLog = false); public abstract List<Byte> DecodeDataForPhysicalLayer(String ident, Byte command, Byte[] payload, Boolean hideDataInLog = false);
public abstract List<Byte> DecodeDataForLogicLayer(List<Byte> rawData); public abstract List<Byte> DecodeDataForLogicLayer(String ident, List<Byte> rawData, Boolean hideDataInLog = false);
public abstract List<Byte> DecodeDataForPhysicalLayerUI1236(Byte[] payload); public abstract List<Byte> DecodeDataForPhysicalLayerUI1236(String ident, Byte[] payload, Boolean hideDataInLog = false);
} }
@@ -23,16 +23,16 @@ namespace Xylem.Common.Hardware.Interfaces.Protocols.TransmitProtocol
void SetDefaultResponseTimeout(); void SetDefaultResponseTimeout();
// ReSharper disable once InconsistentNaming UI1236 is a naming forced by the caller // ReSharper disable once InconsistentNaming UI1236 is a naming forced by the caller
List<Byte> DecodeDataForPhysicalLayerUI1236(Byte[] payload); List<Byte> DecodeDataForPhysicalLayerUI1236(String ident, Byte[] payload, Boolean hideDataInLog = false);
/// <summary> /// <summary>
/// Send out data (including transport protocol specific data like CRC) to physical port (like UART or IrDA) /// Send out data (including transport protocol specific data like CRC) to physical port (like UART or IrDA)
/// </summary> /// </summary>
List<Byte> DecodeDataForPhysicalLayer(Byte command , Byte[] payload, Boolean hideDateInLog = false); List<Byte> DecodeDataForPhysicalLayer(String ident, Byte command , Byte[] payload, Boolean hideDataInLog = false);
/// <summary> /// <summary>
/// Received data have to be checked and converted to request protocol /// Received data have to be checked and converted to request protocol
/// </summary> /// </summary>
List<Byte> DecodeDataForLogicLayer(List<Byte> rawData); List<Byte> DecodeDataForLogicLayer(String ident, List<Byte> rawData, Boolean hideDateInLog = false);
} }
} }
@@ -90,9 +90,15 @@ namespace Xylem.Common.Hardware.Interfaces.Protocols.TransmitProtocol
/// - Wakeup message detection reported to log-file, /// - Wakeup message detection reported to log-file,
/// - Message error text changed. /// - Message error text changed.
/// </remarks> /// </remarks>
public override List<Byte> DecodeDataForLogicLayer(List<Byte> irdaRecord) /// <remarks date="2023-Sep-01" author="T.Wiedebusch">
/// - Hide data in log introduced.
/// </remarks>
public override List<Byte> DecodeDataForLogicLayer(String ident, List<Byte> irdaRecord, Boolean hideDataInLog = false)
{ {
Logger.Info($"DecodeDataForPhysicalLayer Cordonel->PC({BitConverter.ToString(irdaRecord.ToArray())})"); // avoid logging of passwords or other sensitive data
Logger.Info(hideDataInLog
? $"{ident} DecodeDataForLogicalLayer Cordonel->PC(*****)"
: $"{ident} DecodeDataForLogicalLayer Cordonel->PC({BitConverter.ToString(irdaRecord.ToArray())})");
// check the record length and start of frame information // check the record length and start of frame information
if (irdaRecord.Count < IrdaProtocolFrameLength + irdaRecord[IrdaPayLoadLengthIndex] if (irdaRecord.Count < IrdaProtocolFrameLength + irdaRecord[IrdaPayLoadLengthIndex]
@@ -102,7 +108,7 @@ namespace Xylem.Common.Hardware.Interfaces.Protocols.TransmitProtocol
|| ((irdaRecord[IrdaMessageIndex] != IrdaMessageId) || ((irdaRecord[IrdaMessageIndex] != IrdaMessageId)
&& irdaRecord[IrdaMessageIndex] != IrdaWakeupId))) && irdaRecord[IrdaMessageIndex] != IrdaWakeupId)))
{ {
var error = new ApplicationException("Reply from IrDA is invalid."); var error = new ApplicationException($"{ident} Reply from IrDA is invalid.");
Logger.Error(error.Message, error); Logger.Error(error.Message, error);
return new List<Byte>(); return new List<Byte>();
@@ -123,7 +129,7 @@ namespace Xylem.Common.Hardware.Interfaces.Protocols.TransmitProtocol
if (receivedCrc != calculatedCrc) if (receivedCrc != calculatedCrc)
{ {
var error = new ApplicationException("Reply CRC failure. Decoding of transmit layer failed."); var error = new ApplicationException($"{ident} Reply CRC failure. Decoding of transmit layer failed.");
Logger.Error(error.Message, error); Logger.Error(error.Message, error);
return new List<Byte>(); return new List<Byte>();
} }
@@ -142,8 +148,8 @@ namespace Xylem.Common.Hardware.Interfaces.Protocols.TransmitProtocol
/// <remarks date="2023-Mai-16" author="T.Wiedebusch"> /// <remarks date="2023-Mai-16" author="T.Wiedebusch">
/// - Hide data in log forwarded to DecodeDateForPhysicalLayer to hide passwords in log files. /// - Hide data in log forwarded to DecodeDateForPhysicalLayer to hide passwords in log files.
/// </remarks> /// </remarks>
public override List<Byte> DecodeDataForPhysicalLayer(Byte requestProtocolCommand, Byte[] requestProtocolPayload, public override List<Byte> DecodeDataForPhysicalLayer(String ident, Byte requestProtocolCommand, Byte[] requestProtocolPayload,
Boolean hideDateInLog = false) Boolean hideDataInLog = false)
{ {
var irdaCrcInputBuffer = new List<Byte> var irdaCrcInputBuffer = new List<Byte>
{ {
@@ -170,9 +176,9 @@ namespace Xylem.Common.Hardware.Interfaces.Protocols.TransmitProtocol
irdaRecord.Add((Byte)(crcResult >> 8)); irdaRecord.Add((Byte)(crcResult >> 8));
// avoid logging of passwords or other sensitive data // avoid logging of passwords or other sensitive data
Logger.Info(hideDateInLog Logger.Info(hideDataInLog
? "DecodeDataForPhysicalLayer PC->Cordonel(*******************)" ? $"{ident} DecodeDataForPhysicalLayer PC->Cordonel(*****)"
: $"DecodeDataForPhysicalLayer PC->Cordonel({BitConverter.ToString(irdaRecord.ToArray())})"); : $"{ident} DecodeDataForPhysicalLayer PC->Cordonel({BitConverter.ToString(irdaRecord.ToArray())})");
return irdaRecord; return irdaRecord;
} }
@@ -181,7 +187,8 @@ namespace Xylem.Common.Hardware.Interfaces.Protocols.TransmitProtocol
/// <remarks date="2022-Aug-24" author="R.Drabesch"> /// <remarks date="2022-Aug-24" author="R.Drabesch">
/// - Initial /// - Initial
/// </remarks> /// </remarks>
public override List<Byte> DecodeDataForPhysicalLayerUI1236(Byte[] requestProtocolPayload) public override List<Byte> DecodeDataForPhysicalLayerUI1236(String ident, Byte[] requestProtocolPayload,
Boolean hideDataInLog = false)
{ {
var collection = new List<Byte> var collection = new List<Byte>
{ {
@@ -197,7 +204,10 @@ namespace Xylem.Common.Hardware.Interfaces.Protocols.TransmitProtocol
byteList.AddRange(collection); byteList.AddRange(collection);
byteList.Add((Byte)(crcResult & 0xFF)); byteList.Add((Byte)(crcResult & 0xFF));
byteList.Add((Byte)(crcResult >> 8)); byteList.Add((Byte)(crcResult >> 8));
Logger.Info("DecodeDataForPhysicalLayerUI1236 PC->Cordonel(" + BitConverter.ToString(byteList.ToArray()) + ")"); // avoid logging of passwords or other sensitive data
Logger.Info(hideDataInLog
? $"{ident} DecodeDataForPhysicalLayerUI1236 PC->Cordonel(*****)"
: $"{ident} DecodeDataForPhysicalLayerUI1236 PC->Cordonel({BitConverter.ToString(byteList.ToArray())})");
return byteList; return byteList;
} }
} }
@@ -37,17 +37,18 @@ namespace Xylem.Common.Hardware.Interfaces.Protocols.TransmitProtocol
} }
/// <inheritdoc /> /// <inheritdoc />
public override List<Byte> DecodeDataForPhysicalLayer(Byte command, Byte[] payload, Boolean hideDateInLog = false) public override List<Byte> DecodeDataForPhysicalLayer(String ident, Byte command, Byte[] payload, Boolean hideDataInLog = false)
{ {
throw new ApplicationException("Streaming port cannot send data"); throw new ApplicationException("Streaming port cannot send data");
} }
/// <inheritdoc /> /// <inheritdoc />
public override List<Byte> DecodeDataForLogicLayer(List<Byte> rawData) public override List<Byte> DecodeDataForLogicLayer(String ident, List<Byte> rawData, Boolean hideDataInLog = false)
{ {
return rawData; return rawData;
} }
public override List<Byte> DecodeDataForPhysicalLayerUI1236(Byte[] payload) => throw new ApplicationException("Streaming port cannot send data"); public override List<Byte> DecodeDataForPhysicalLayerUI1236(String ident, Byte[] payload, Boolean hideDataInLog = false)
=> throw new ApplicationException("Streaming port cannot send data");
} }
} }
@@ -55,13 +55,13 @@ namespace Xylem.Common.Hardware.Interfaces.Protocols.TransmitProtocol
_responseTimeoutMs, BaudRate, _receiveBufferFlushThreshold, UartDoubleSyncByte); _responseTimeoutMs, BaudRate, _receiveBufferFlushThreshold, UartDoubleSyncByte);
} }
public override List<Byte> DecodeDataForLogicLayer(List<Byte> uartRecord) public override List<Byte> DecodeDataForLogicLayer(String ident, List<Byte> uartRecord, Boolean hideDataInLog = false)
{ {
// check the record length and start of frame information // check the record length and start of frame information
if (uartRecord.Count < uartRecord[UartLengthIndex] + UartSyncByteLength if (uartRecord.Count < uartRecord[UartLengthIndex] + UartSyncByteLength
|| UartSyncByte != uartRecord[UartSyncByteIndex]) || UartSyncByte != uartRecord[UartSyncByteIndex])
{ {
var error = new ApplicationException("Reply from UART is invalid. Decoding of transmit layer failed."); var error = new ApplicationException($"{ident} Reply from UART is invalid. Decoding of transmit layer failed.");
Logger.Error(error.Message, error); Logger.Error(error.Message, error);
return new List<Byte>(); return new List<Byte>();
} }
@@ -77,7 +77,7 @@ namespace Xylem.Common.Hardware.Interfaces.Protocols.TransmitProtocol
if(receivedCrc != calculatedCrc) if(receivedCrc != calculatedCrc)
{ {
var error = new ApplicationException("Reply CRC failure. Decoding of transmit layer failed."); var error = new ApplicationException($"{ident} Reply CRC failure. Decoding of transmit layer failed.");
Logger.Error(error.Message, error); Logger.Error(error.Message, error);
return new List<Byte>(); return new List<Byte>();
} }
@@ -111,7 +111,7 @@ namespace Xylem.Common.Hardware.Interfaces.Protocols.TransmitProtocol
} }
/// <inheritdoc /> /// <inheritdoc />
public override List<Byte> DecodeDataForPhysicalLayer(Byte requestProtocolCommand, public override List<Byte> DecodeDataForPhysicalLayer(String ident, Byte requestProtocolCommand,
Byte[] requestProtocolPayload, Boolean hideDataInLog = false) Byte[] requestProtocolPayload, Boolean hideDataInLog = false)
{ {
var uartHeader = new List<Byte>(); var uartHeader = new List<Byte>();
@@ -148,7 +148,8 @@ namespace Xylem.Common.Hardware.Interfaces.Protocols.TransmitProtocol
/// <remarks date="2022-Aug-24" author="R.Drabesch"> /// <remarks date="2022-Aug-24" author="R.Drabesch">
/// - Initial /// - Initial
/// </remarks> /// </remarks>
public override List<Byte> DecodeDataForPhysicalLayerUI1236(Byte[] requestProtocolPayload) public override List<Byte> DecodeDataForPhysicalLayerUI1236(String ident, Byte[] requestProtocolPayload,
Boolean hideDataInLog = false)
{ {
var uartHeader = new List<Byte>(); var uartHeader = new List<Byte>();
var uartPayload = requestProtocolPayload.ToList(); var uartPayload = requestProtocolPayload.ToList();
@@ -169,7 +169,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
actualRegister.DataType = typeof(UInt96); actualRegister.DataType = typeof(UInt96);
break; break;
case "int8_t": case "int8_t":
actualRegister.DataType = typeof(sbyte); actualRegister.DataType = typeof(SByte);
break; break;
case "int32_t": case "int32_t":
actualRegister.DataType = typeof(Int32); actualRegister.DataType = typeof(Int32);
@@ -1313,7 +1313,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
//avoid overwriting of list if this already exits //avoid overwriting of list if this already exits
if (MeterAppListVersion.Any()) if (MeterAppListVersion.Any())
{ {
_logger.Warn("Trying to override meter dictionary. Skip read out FW"); _logger.Warn($"Slot:{Slot} - Trying to override meter dictionary. Skip read out FW");
return; return;
} }
@@ -1393,29 +1393,29 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
} }
//log application information to file //log application information to file
_logger.Info($"PCB ID: {PcbId}"); _logger.Info($"Slot:{Slot} - PCB ID: {PcbId}");
_logger.Info($"Date time (UTC): {DateTimeOffset.UtcNow}"); _logger.Info($"Slot:{Slot} - Date time (UTC): {DateTimeOffset.UtcNow}");
if (CoreRevision != null) if (CoreRevision != null)
{ {
_logger.Info("System Core Revision: " + BuildFwVersionString(CoreRevision)); _logger.Info($"Slot:{Slot} - System Core Revision: {BuildFwVersionString(CoreRevision)}");
} }
_logger.Info("Region: " + Region); _logger.Info($"Slot:{Slot} - Region: {Region}");
if (RadioFrequencyMhz != null) if (RadioFrequencyMhz != null)
{ {
_logger.Info($"Radio frequency [MHz]: {RadioFrequencyMhz}"); _logger.Info($"Slot:{Slot} - Radio frequency [MHz]: {RadioFrequencyMhz}");
} }
foreach (var fm in MeterAppListVersion.OrderBy(o => o.AppId)) foreach (var fm in MeterAppListVersion.OrderBy(o => o.AppId))
{ {
var versionString = fm.IsInstalled var versionString = fm.IsInstalled
? $"V: {fm.StrVersion} - CRC: 0x{fm.Crc:X4}" : "Not installed"; ? $"V: {fm.StrVersion} - CRC: 0x{fm.Crc:X4}" : "Not installed";
_logger.Info($"AppId: 0x{fm.AppId:X2} - {versionString} - AppName: {fm.AppName}"); _logger.Info($"Slot:{Slot} - AppId: 0x{fm.AppId:X2} - {versionString} - AppName: {fm.AppName}");
} }
_logger.Info($"Meter size: {MeterSize}"); _logger.Info($"Slot:{Slot} - Meter size: {MeterSize}");
_logger.Info($"Upgrade permission: {MetrologyUpgradePermission:X2}"); _logger.Info($"Slot:{Slot} - Upgrade permission: {MetrologyUpgradePermission:X2}");
//remove unused registers with invalid version //remove unused registers with invalid version
var tempConfigRegisters = _configRegister.MeterRegisterDic.ToList(); var tempConfigRegisters = _configRegister.MeterRegisterDic.ToList();
@@ -1460,7 +1460,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
catch (Exception ex) catch (Exception ex)
{ {
_logger.Warn(ex, $"Not able to set minimum list of registers. check json file for {checkMinRegister} "); _logger.Warn(ex, $"Slot:{Slot} - Not able to set minimum list of registers. check json file for {checkMinRegister} ");
} }
} }
} }
@@ -1871,7 +1871,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
} }
catch (Exception e) catch (Exception e)
{ {
_logger.Error(e); _logger.Error($"Slot:{Slot} - {e}");
} }
return false; return false;
@@ -1912,7 +1912,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
} }
catch (Exception e) catch (Exception e)
{ {
_logger.Error(e); _logger.Error($"Slot:{Slot} - {e}");
} }
return null; return null;
@@ -1962,10 +1962,12 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// - Initial /// - Initial
/// </remarks> /// </remarks>
// ReSharper disable once InconsistentNaming UI1236 is a naming forced by the caller // ReSharper disable once InconsistentNaming UI1236 is a naming forced by the caller
public Byte[] SendUI1236Command(Byte[] ui1236Frame, Boolean waitForResult = true, Boolean checkRegister = false, UInt16 skipRetryErrorCode = 4) public Byte[] SendUI1236Command(Byte[] ui1236Frame, Boolean waitForResult = true, Boolean checkRegister = false,
UInt16 skipRetryErrorCode = 4)
{ {
_logger.Info($"Slot:{Slot} - Sending Ui-1236 frame: {ui1236Frame} "); var requestIdent = $"Slot:{Slot} - Sending Ui-1236 frame";
var sendFifoUi1236 = RequestProtocol.AddRecordToSendFifoUI1236(ui1236Frame); _logger.Info(requestIdent);
var sendFifoUi1236 = RequestProtocol.AddRecordToSendFifoUI1236(requestIdent, ui1236Frame);
RequestProtocolProcess(); RequestProtocolProcess();
return sendFifoUi1236.ResponsePayload.ToArray(); return sendFifoUi1236.ResponsePayload.ToArray();
} }
@@ -2051,16 +2053,6 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
public void WriteLog(String text) public void WriteLog(String text)
{ {
_logger.Info($"Slot:{Slot} - {text}"); _logger.Info($"Slot:{Slot} - {text}");
//if (_enableRawDataLogging)
//{
// if (_loggerRawData == null)
// {
// _loggerRawData = NLogHelper.CreateOrGetMultiLogger(
// StreamingPort.GetPortName(), "", "LedRawData", "TargetLedRawDataBase", "LedRawDataBase");
// }
// _loggerRawData.Info($"{text}");
//}
} }
/// <inheritdoc /> /// <inheritdoc />
@@ -2307,7 +2299,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
} }
catch (Exception ex) catch (Exception ex)
{ {
_logger.Error(ex, "Can't store at RegisterWatchService"); _logger.Error($"Slot:{Slot} - {ex} - Can't store at RegisterWatchService");
} }
} }
@@ -2337,13 +2329,13 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
if (!result) if (!result)
{ {
_logger.Error(new Exception($"HTTP status not OK"), _logger.Error(new Exception($"Slot:{Slot} - HTTP status not OK"),
"Can't store at RegisterWatchService"); "Can't store at RegisterWatchService");
} }
} }
catch (Exception ex) catch (Exception ex)
{ {
_logger.Error(ex, "Can't store at RegisterWatchService"); _logger.Error($"Slot:{Slot} - {ex} - Can't store at RegisterWatchService");
} }
} }
} }
@@ -2384,12 +2376,12 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
if (response.StatusCode != HttpStatusCode.OK && response.StatusCode != HttpStatusCode.Accepted) if (response.StatusCode != HttpStatusCode.OK && response.StatusCode != HttpStatusCode.Accepted)
{ {
_logger.Error(new Exception($"HTTP status not OK({response.StatusCode})"), "can not store at RegisterWatchService"); _logger.Error(new Exception($"Slot:{Slot} - HTTP status not OK({response.StatusCode})"), "can not store at RegisterWatchService");
} }
} }
catch (Exception ex) catch (Exception ex)
{ {
_logger.Error(ex, "can not store at RegisterWatchService"); _logger.Error($"Slot:{Slot} - {ex} - can not store at RegisterWatchService");
} }
} }
} }
@@ -175,7 +175,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.Protocols.RequestProtocol
/// </remarks> /// </remarks>
public RequestAcknowledgeState ProcessRecordList() public RequestAcknowledgeState ProcessRecordList()
{ {
_logger.Trace($" Enry to ProcessRecordList, FIFO contains ({_recordsSendFifo.Count}) records"); _logger.Trace($"{_ident} Entry to ProcessRecordList, FIFO contains ({_recordsSendFifo.Count}) records");
//The inter record send delay has to be hold before trying to communicate again //The inter record send delay has to be hold before trying to communicate again
const Int32 interRecordSendDelayMs = CommunicationConfig.InterRecordSendDelayMs; const Int32 interRecordSendDelayMs = CommunicationConfig.InterRecordSendDelayMs;
@@ -188,27 +188,28 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.Protocols.RequestProtocol
{ {
// Starting with record number 1 // Starting with record number 1
loopCounter++; loopCounter++;
_logger.Trace($"Record({loopCounter}) - Dequeued from FIFO"); _logger.Trace($"{_ident} Record({loopCounter}) - Dequeued from FIFO");
//pointer to new record //pointer to new record
_recordInProcess = internalRecord; _recordInProcess = internalRecord;
if (_recordInProcess == null) return RequestAcknowledgeState.CommandNotAssigned; if (_recordInProcess == null)
return RequestAcknowledgeState.CommandNotAssigned;
//mark record as answer outstanding //mark record as answer outstanding
_recordInProcess.Acknowledge = RequestAcknowledgeState.NotDecoded; _recordInProcess.Acknowledge = RequestAcknowledgeState.NotDecoded;
do do
{ {
_logger.Trace($"Record({loopCounter}) - Processing"); _logger.Trace($"{_ident} Record({loopCounter}) - Processing");
//log retries //log retries
if (_recordInProcess.RetryCtr > 0) if (_recordInProcess.RetryCtr > 0)
{ {
_logger.Debug($"{_ident} Retry({_recordInProcess.RetryCtr})"); _logger.Debug($"{_ident} Retry({_recordInProcess.RetryCtr})");
_logger.Trace($"Record({loopCounter}) - Retry({_recordInProcess.RetryCtr})"); _logger.Trace($"{_ident} Record({loopCounter}) - Retry({_recordInProcess.RetryCtr})");
} }
//log request protocol content //log request protocol content
_logger.Debug(_recordInProcess.HideDataInLog _logger.Debug(_recordInProcess.HideDataInLog
? $"{_ident} SentData(*********************************)" ? $"{_ident} SentData(*****)"
: $"{_ident} SentData({BitConverter.ToString(_recordInProcess.RequestProtocolData.ToArray())})"); : $"{_ident} SentData({BitConverter.ToString(_recordInProcess.RequestProtocolData.ToArray())})");
//remind time for keep-session-active test to deny automatic logout of meter //remind time for keep-session-active test to deny automatic logout of meter
@@ -220,7 +221,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.Protocols.RequestProtocol
CommunicationConfig.ResponseTimeoutMs * (_recordInProcess.RetryCtr + 1); CommunicationConfig.ResponseTimeoutMs * (_recordInProcess.RetryCtr + 1);
//start initial communication or retry //start initial communication or retry
OnRecordReadyToSend?.Invoke(this, new ListBytePortDataEventArgs(_recordInProcess.EncodedRequestData)); OnRecordReadyToSend?.Invoke(this, new ListBytePortDataEventArgs(_recordInProcess.EncodedRequestData));
//time reminder of request record //time reminder of request record
var requestTimeUtc = DateTimeOffset.UtcNow; var requestTimeUtc = DateTimeOffset.UtcNow;
Int32 actualResponseWaitTimeMs; Int32 actualResponseWaitTimeMs;
@@ -319,7 +320,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.Protocols.RequestProtocol
//encode request protocol data with transmit protocol //encode request protocol data with transmit protocol
var transmit = GetTransmitProtocol(); var transmit = GetTransmitProtocol();
var dataEncodedWithTransmitProtocol = transmit.DecodeDataForPhysicalLayer(cmd, payload, hideDataInLog); var dataEncodedWithTransmitProtocol = transmit.DecodeDataForPhysicalLayer(_ident, cmd, payload, hideDataInLog);
//remind port specific response timeout //remind port specific response timeout
var transmitPortSettings = transmit.GetTransmitPortSettings(); var transmitPortSettings = transmit.GetTransmitPortSettings();
@@ -339,13 +340,14 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.Protocols.RequestProtocol
/// <remarks date="2022-Aug-24" author="R.Drabesch"> /// <remarks date="2022-Aug-24" author="R.Drabesch">
/// - Initial /// - Initial
/// </remarks> /// </remarks>
/// <param name="ident">string for logging of slot</param>
/// <param name="payload">Data package with all details like CRC, etc</param> /// <param name="payload">Data package with all details like CRC, etc</param>
/// <param name="register"><see cref="RegisterDefinition" /> which is intend</param> /// <param name="register"><see cref="RegisterDefinition" /> which is intend</param>
/// <param name="hideDataInLog">hiding data in log file to avoid spying of passwords</param> /// <param name="hideDataInLog">hiding data in log file to avoid spying of passwords</param>
/// <param name="skipRetryErrorCode">error mask to skip retries</param> /// <param name="skipRetryErrorCode">error mask to skip retries</param>
/// <returns>the assembled record for the send FIFO</returns> /// <returns>the assembled record for the send FIFO</returns>
// ReSharper disable once InconsistentNaming UI1236 is a naming forced by the caller // ReSharper disable once InconsistentNaming UI1236 is a naming forced by the caller
public RequestRecord AddRecordToSendFifoUI1236(Byte[] payload, RegisterDefinition register = null, public RequestRecord AddRecordToSendFifoUI1236(String ident, Byte[] payload, RegisterDefinition register = null,
Boolean hideDataInLog = false, UInt16 skipRetryErrorCode = CommunicationConfig.SkipRetryErrorCode) Boolean hideDataInLog = false, UInt16 skipRetryErrorCode = CommunicationConfig.SkipRetryErrorCode)
{ {
const Byte maxValue = byte.MaxValue; const Byte maxValue = byte.MaxValue;
@@ -355,9 +357,9 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.Protocols.RequestProtocol
}; };
requestProtocolData.AddRange(payload); requestProtocolData.AddRange(payload);
var transmitProtocol = GetTransmitProtocol(); var transmitProtocol = GetTransmitProtocol();
var encodedRequestData = transmitProtocol.DecodeDataForPhysicalLayerUI1236(payload); var encodedRequestData = transmitProtocol.DecodeDataForPhysicalLayerUI1236(ident, payload, hideDataInLog);
var transmitPortSettings = transmitProtocol.GetTransmitPortSettings(); var transmitPortSettings = transmitProtocol.GetTransmitPortSettings();
var sendFifoUi1236 = new RequestRecord(maxValue, requestProtocolData, encodedRequestData, var sendFifoUi1236 = new RequestRecord(maxValue, requestProtocolData, encodedRequestData,
transmitPortSettings.ResponseTimeoutMs, register, hideDataInLog, skipRetryErrorCode); transmitPortSettings.ResponseTimeoutMs, register, hideDataInLog, skipRetryErrorCode);
_recordsSendFifo.Enqueue(sendFifoUi1236); _recordsSendFifo.Enqueue(sendFifoUi1236);
return sendFifoUi1236; return sendFifoUi1236;
@@ -407,13 +409,18 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.Protocols.RequestProtocol
/// - Wakeup message retries from 5 to 2, /// - Wakeup message retries from 5 to 2,
/// - Removed error base from error code decision as error base is only the AppId /// - Removed error base from error code decision as error base is only the AppId
/// </remarks> /// </remarks>
/// <remarks date="2023-Sep-01" author="T.Wiedebusch">
/// - HideDataInLog.
/// </remarks>
protected override void DecodeRecord(IPortDataEventArgs data) protected override void DecodeRecord(IPortDataEventArgs data)
{ {
if (_recordInProcess == null) return; if (_recordInProcess == null)
return;
//new request has to be analyzed //new request has to be analyzed
_recordInProcess.Acknowledge = RequestAcknowledgeState.NotDecoded; _recordInProcess.Acknowledge = RequestAcknowledgeState.NotDecoded;
//the request response record covers the entire request protocol //the request response record covers the entire request protocol
var responseRecord = GetTransmitProtocol().DecodeDataForLogicLayer((List<Byte>)data.GetData()); var responseRecord = GetTransmitProtocol().DecodeDataForLogicLayer(_ident, (List<Byte>)data.GetData(),
_recordInProcess.HideDataInLog);
//on protocol decoding failure //on protocol decoding failure
if (responseRecord.Count == 0) if (responseRecord.Count == 0)
@@ -442,7 +449,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.Protocols.RequestProtocol
{ {
_recordInProcess.Acknowledge = RequestAcknowledgeState.WakeupMessage; _recordInProcess.Acknowledge = RequestAcknowledgeState.WakeupMessage;
//initiate a single retry on wakeup message response //initiate a single retry on wakeup message response
if ( _recordInProcess.WakeupMessageRetryCtr < 2) if (_recordInProcess.WakeupMessageRetryCtr < 2)
{ {
_recordInProcess.WakeupMessageRetryCtr++; _recordInProcess.WakeupMessageRetryCtr++;
_logger.Debug($"{_ident} Wakeup message({_recordInProcess.WakeupMessageRetryCtr}) received"); _logger.Debug($"{_ident} Wakeup message({_recordInProcess.WakeupMessageRetryCtr}) received");
@@ -465,7 +472,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.Protocols.RequestProtocol
//log request protocol content //log request protocol content
_logger.Debug(_recordInProcess.HideDataInLog _logger.Debug(_recordInProcess.HideDataInLog
? $"{_ident} DecodedRecord(*********************************)" ? $"{_ident} DecodedRecord(*****)"
: $"{_ident} DecodedRecord({BitConverter.ToString(responseRecord.ToArray())})"); : $"{_ident} DecodedRecord({BitConverter.ToString(responseRecord.ToArray())})");
//extract information command //extract information command
@@ -605,17 +612,20 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.Protocols.RequestProtocol
if (cRecord.ResponsePayload.Contains(0)) if (cRecord.ResponsePayload.Contains(0))
{ {
cRecord.ResponsePayload = completeResponse; cRecord.ResponsePayload = completeResponse;
OnMeterRegisterUpdated?.Invoke(this, new RegisterUpdatedEventArgs(meterRegister, completeResponse.ToArray())); OnMeterRegisterUpdated?.Invoke(this,
new RegisterUpdatedEventArgs(meterRegister, completeResponse.ToArray()));
if (expectedLength.HasValue && completeResponse.Count < expectedLength.Value) if (expectedLength.HasValue && completeResponse.Count < expectedLength.Value)
{ {
_logger.Debug("Too Short. Payload contains zero"); _logger.Debug("Too Short. Payload contains zero");
} }
return cRecord; return cRecord;
} }
} }
else else
{ {
if (expectedLength.HasValue && completeResponse.Any() && completeResponse.Count < expectedLength.Value) if (expectedLength.HasValue && completeResponse.Any() &&
completeResponse.Count < expectedLength.Value)
{ {
if (rest != RequestAcknowledgeState.Ok) if (rest != RequestAcknowledgeState.Ok)
{ {
@@ -635,6 +645,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.Protocols.RequestProtocol
} }
} }
return cRecord; return cRecord;
} }
} }
@@ -753,7 +764,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.Protocols.RequestProtocol
/// <returns></returns> /// <returns></returns>
public Boolean ContainsRegisterIdent(String registerName) public Boolean ContainsRegisterIdent(String registerName)
{ {
return _recordsSendFifo.Any(a => string.Equals(a.Register.GetIdent(), return _recordsSendFifo.Any(a => string.Equals(a.Register.GetIdent(),
registerName, StringComparison.CurrentCultureIgnoreCase)); registerName, StringComparison.CurrentCultureIgnoreCase));
} }
} }
+38 -14
View File
@@ -41,7 +41,10 @@ namespace Xylem.Common.Ui.GenesisToolBox
private MeterBatch _meterBatch = new MeterBatch(); private MeterBatch _meterBatch = new MeterBatch();
private readonly ILogger logger = NLogHelper.CreateOrGetLogger("GenesisFwLogger"); private readonly ILogger logger = NLogHelper.CreateOrGetLogger("GenesisFwLogger");
public Boolean IsBusy { get; private set; } public Boolean IsBusy
{
get; private set;
}
public FrmRegisterStore() public FrmRegisterStore()
{ {
@@ -270,14 +273,20 @@ namespace Xylem.Common.Ui.GenesisToolBox
Console.WriteLine(value); Console.WriteLine(value);
Task.Factory.StartNew(() => { read(); }).ContinueWith(delegate { SetBusy(false); }); Task.Factory.StartNew(() => { read(); }).ContinueWith(delegate
{
SetBusy(false);
});
} }
private void btnStore_Click(Object sender, EventArgs e) private void btnStore_Click(Object sender, EventArgs e)
{ {
SetBusy(true, "Store to file"); SetBusy(true, "Store to file");
Task.Factory.StartNew(() => { store(); }).ContinueWith(delegate { SetBusy(false); }); Task.Factory.StartNew(() => { store(); }).ContinueWith(delegate
{
SetBusy(false);
});
} }
private void btnFileToMeter_Click(Object sender, EventArgs e) private void btnFileToMeter_Click(Object sender, EventArgs e)
@@ -293,7 +302,10 @@ namespace Xylem.Common.Ui.GenesisToolBox
var filename = openFileDialog.FileName; var filename = openFileDialog.FileName;
Task.Factory.StartNew(() => { load(filename); }).ContinueWith(delegate { SetBusy(false); }); Task.Factory.StartNew(() => { load(filename); }).ContinueWith(delegate
{
SetBusy(false);
});
} }
} }
@@ -304,7 +316,10 @@ namespace Xylem.Common.Ui.GenesisToolBox
{ {
SetBusy(true, "writing register to meter"); SetBusy(true, "writing register to meter");
Task.Factory.StartNew(() => { WriteRegister(e); }).ContinueWith(delegate { SetBusy(false); }); Task.Factory.StartNew(() => { WriteRegister(e); }).ContinueWith(delegate
{
SetBusy(false);
});
} }
} }
@@ -329,11 +344,14 @@ namespace Xylem.Common.Ui.GenesisToolBox
array[i] = Convert.ToByte(arr[i], 16); array[i] = Convert.ToByte(arr[i], 16);
} }
array = array.Reverse().ToArray();
// currentGenesis.WriteRegister(Register.Genesisflow.LedMode, (Byte)Ledmode.FlowTestAndCalibData, checkRegister: true); // currentGenesis.WriteRegister(Register.Genesisflow.LedMode, (Byte)Ledmode.FlowTestAndCalibData, checkRegister: true);
var regdef = var reg = (String)registerGridView.Rows[e.RowIndex].Cells[0].Value;
(String)registerGridView.Rows[e.RowIndex].Cells[0].Value; var meterRegisters = _currentGenesis.GetConfigRegistersDefinitions();
_currentGenesis.WriteRegister(regdef, array, checkRegister: true); var regDef = meterRegisters.GetRegisterDefinitionByName(reg);
if (regDef.DataType != typeof(String))
array = array.Reverse().ToArray();
_currentGenesis.WriteRegister(reg, array, checkRegister: true);
//_currentGenesis.Logout(); //_currentGenesis.Logout();
//var funkadresse = new List<byte>(); //var funkadresse = new List<byte>();
@@ -432,7 +450,7 @@ namespace Xylem.Common.Ui.GenesisToolBox
{ {
Logger.Value.Error(ex, $"Slot #{slotNR} failed: {ex.Message}"); Logger.Value.Error(ex, $"Slot #{slotNR} failed: {ex.Message}");
} }
_currentGenesis.Login("B507CC0978D6"); _currentGenesis.Login();
_currentPcbId = _currentGenesis.PcbId; _currentPcbId = _currentGenesis.PcbId;
@@ -633,7 +651,9 @@ namespace Xylem.Common.Ui.GenesisToolBox
private void read() private void read()
{ {
regsToStore = new regStore() regsToStore = new regStore()
{ PcbId = _currentPcbId, created = DateTimeOffset.Now, keyValues = new List<regDefValue>() }; {
PcbId = _currentPcbId, created = DateTimeOffset.Now, keyValues = new List<regDefValue>()
};
var total = 0; var total = 0;
foreach (var rowItem in _dataTable.Rows) foreach (var rowItem in _dataTable.Rows)
{ {
@@ -678,12 +698,15 @@ namespace Xylem.Common.Ui.GenesisToolBox
} }
var tmpList = rawRegister.ToList(); var tmpList = rawRegister.ToList();
tmpList.Reverse(); if (regDef.DataType != typeof(String))
tmpList.Reverse();
if (rawRegister != null) if (rawRegister != null)
{ {
((DataRow)rowItem)["RawValue"] = BitConverter.ToString(tmpList.ToArray()); ((DataRow)rowItem)["RawValue"] = BitConverter.ToString(tmpList.ToArray());
regsToStore.keyValues.Add(new regDefValue() regsToStore.keyValues.Add(new regDefValue()
{ def = regDef, value = BitConverter.ToString(rawRegister) }); {
def = regDef, value = BitConverter.ToString(rawRegister)
});
} }
@@ -770,7 +793,8 @@ namespace Xylem.Common.Ui.GenesisToolBox
} }
var tmpList = rawRegister.ToList(); var tmpList = rawRegister.ToList();
tmpList.Reverse(); if (regDef.DataType != typeof(String))
tmpList.Reverse();
if (rawRegister != null) if (rawRegister != null)
{ {
+1 -1
View File
@@ -43,7 +43,7 @@ namespace Xylem.Common.Ui.IrdaFunctionalTestApp
Byte command = 0x09; Byte command = 0x09;
Byte []payload = {0x0D, 0x0F, 0x00, 0x00, 0x00, 0x00 }; Byte []payload = {0x0D, 0x0F, 0x00, 0x00, 0x00, 0x00 };
var txBuffer = transmit.DecodeDataForPhysicalLayer(command, payload); var txBuffer = transmit.DecodeDataForPhysicalLayer(Ident, command, payload);
_irdaComPort.Open(); _irdaComPort.Open();