FwUpdateBuilder:
- special characters from FwUpdateSafe removed, - customer name limited to 45 characters for FwUpdateFile. FwUpdateSw: - Release display soon FW-update succeeded, - new IrDA, BaseSerialPort and TransmittProtocol from common 2.2.8. FwUpdateLoader: - Registration repaired if UserInformation.register does not exists. Common: - ReLogin skipped if already logged in, - NA2WALARMS removed from read back of store configuration to support NA versions below 1.2.x.
This commit is contained in:
@@ -941,8 +941,12 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
/// <remarks date="2019-Jun-23" author="Thomas Wiedebusch">
|
||||
/// - Initial
|
||||
/// </remarks>
|
||||
/// <remarks date="2022-Jul-22" author="Thomas Wiedebusch">
|
||||
/// - Immediately returns if already logged in.
|
||||
/// </remarks>
|
||||
public Boolean ReLogin()
|
||||
{
|
||||
if (IsLoggedOn) return true;
|
||||
return string.IsNullOrEmpty(_password) ? Login() : Login(_password);
|
||||
}
|
||||
|
||||
@@ -970,7 +974,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
}
|
||||
}
|
||||
|
||||
url = url + PcbId;
|
||||
url += PcbId;
|
||||
try
|
||||
{
|
||||
//use
|
||||
@@ -2134,6 +2138,9 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
/// - Removed comparison of allConfigRegisters less than 8 because the NA version has less registers and new
|
||||
/// apps will have a new register.
|
||||
/// </remarks>
|
||||
/// <remarks date="2022-Jul-22" author="Thomas Wiedebusch">
|
||||
/// - Removed temporary NA2ALARMS readback as this has no handler in the FW.
|
||||
/// </remarks>
|
||||
public Boolean StoreAllConfigurations()
|
||||
{
|
||||
|
||||
@@ -2141,11 +2148,6 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
a.Key.RegisterName.ToLower() == "storeconfiguration" ||
|
||||
a.Key.RegisterName.ToLower() == "storecalibration");
|
||||
|
||||
//if (allConfigRegisters < 8)
|
||||
//{
|
||||
// return false;
|
||||
//}
|
||||
|
||||
try
|
||||
{
|
||||
foreach (var a in _configRegister.MeterRegisterDic.Where(a =>
|
||||
@@ -2174,7 +2176,8 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
|
||||
// Wait for storing
|
||||
Thread.Sleep(400);
|
||||
if (a.Key.AppName == "SENSUSRADIO")
|
||||
//TODO enable this for R1.2.x
|
||||
if (a.Key.AppName == "SENSUSRADIO" || a.Key.AppName == "NA2WALARMS")
|
||||
{
|
||||
done = true;
|
||||
allConfigRegisters -= 1;
|
||||
@@ -2201,6 +2204,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
|
||||
catch (Exception)
|
||||
{
|
||||
// ignored
|
||||
}
|
||||
|
||||
return allConfigRegisters == 0;
|
||||
|
||||
Reference in New Issue