still fixing fai bugs
This commit is contained in:
+2
@@ -151,6 +151,8 @@ namespace ProductionUiCordonel.ProductionProcesses.Actions
|
||||
var a = JsonConvert.DeserializeObject<string[]>(responseJson);
|
||||
SerialNumber = Convert.ToInt32(a[0]);
|
||||
Ordernumber = Convert.ToInt32(a[1]);
|
||||
|
||||
Meter.SerialNumber = SerialNumber.ToString();
|
||||
}
|
||||
}
|
||||
else
|
||||
|
||||
+1
-1
@@ -82,7 +82,7 @@ namespace ProductionUiCordonel.ProductionProcesses.Actions
|
||||
private void UserControl_KeyDown(object sender, string input)
|
||||
{
|
||||
var a = input;
|
||||
|
||||
PcbSerialNumber = Meter.SerialNumber;
|
||||
UserControl.txtHiddenInput.Text = "";
|
||||
if (a.Trim().Contains(PcbSerialNumber.Trim()))
|
||||
{
|
||||
|
||||
+8
-1
@@ -124,7 +124,11 @@ namespace ProductionUiCordonel.ProductionProcesses.Actions
|
||||
}
|
||||
//todo: find a better sln for SENSUSRADIO_EncryptionKey
|
||||
//SENSUSRADIO_EncryptionKey dont reserve SENSUSRADIO_EncryptionKey!
|
||||
if (item.RegisterName.ToLower().Contains("SENSUSRADIO_EncryptionKey".ToLower()))
|
||||
if (item.RegisterName.ToLower().Contains("displaypow".ToLower()) || item.RegisterName.ToLower().Contains("METROLOGYASST_FlowPoint".ToLower()) )
|
||||
{
|
||||
overAllResult.Add(_currentGenesis_WriteRegister(item.RegisterName, new byte[] { item.RegisterValue.ToArray()[0] }, true, true));
|
||||
}
|
||||
else if (item.RegisterName.ToLower().Contains("SENSUSRADIO_EncryptionKey".ToLower()))
|
||||
{
|
||||
overAllResult.Add(_currentGenesis_WriteRegister(item.RegisterName, item.RegisterValue.ToArray(), true, true));
|
||||
}
|
||||
@@ -133,6 +137,9 @@ namespace ProductionUiCordonel.ProductionProcesses.Actions
|
||||
overAllResult.Add(_currentGenesis_WriteRegister(item.RegisterName, item.RegisterValue.Reverse().ToArray(), true, true));
|
||||
|
||||
}
|
||||
|
||||
|
||||
|
||||
//else if (!item.RegisterName.ToLower().Contains("apparrangement"))
|
||||
//{
|
||||
// overAllResult.Add(_currentGenesis_WriteRegister(item.RegisterName, item.RegisterValue.Reverse().ToArray(), true, true));
|
||||
|
||||
+2
@@ -58,6 +58,8 @@ namespace ProductionUiCordonel.ProductionProcesses.Actions
|
||||
|
||||
public override void StartProcess()
|
||||
{
|
||||
base.currentProcessState = ProductionProcessState.Done;
|
||||
return;
|
||||
bool ret = RequestPassword();
|
||||
updateImage(UserControl.RequestPassword, ret);
|
||||
base.Progress = base.Progress + 16;
|
||||
|
||||
+43
-31
@@ -13,10 +13,12 @@ namespace ProductionUiCordonel.ProductionProcesses.Actions
|
||||
public class ProductionProcessShippingMode : BaseProductionProcess
|
||||
{
|
||||
private UcPlain UserControl;
|
||||
public ProductionProcessShippingMode()
|
||||
private bool doRestart = false;
|
||||
public ProductionProcessShippingMode(bool restart = false)
|
||||
{
|
||||
name = "Versandbereitschaft herstellen";
|
||||
currentProcessState = ProductionProcessState.Waiting;
|
||||
doRestart = restart;
|
||||
}
|
||||
public override void InitUserControl()
|
||||
{
|
||||
@@ -51,7 +53,7 @@ namespace ProductionUiCordonel.ProductionProcesses.Actions
|
||||
var useRadio = true;
|
||||
if (useRadio)
|
||||
{
|
||||
if (Meter.StoreAllConfigurations())
|
||||
if (Meter.StoreAllConfigurations())
|
||||
{
|
||||
|
||||
var writeList = new List<bool>();
|
||||
@@ -72,45 +74,55 @@ namespace ProductionUiCordonel.ProductionProcesses.Actions
|
||||
var SENSUSRADIO_ExtendedAlarmMask = Meter.ReadRegister("SENSUSRADIO_ExtendedAlarmMask");
|
||||
if (radioResetSuccess[0] == 0x02 && writeList.All(a => a == true) && SENSUSRADIO_MainAlarmMask[0] != 0)
|
||||
{
|
||||
var _meterResetPsu = new MeterResetPsu(Meter)
|
||||
if (doRestart)
|
||||
{
|
||||
StoreConfigEnable = true
|
||||
};
|
||||
var rebootSucceeded = _meterResetPsu.MeterResetPsuExecute();
|
||||
var CheckValuesAufterBoot = new List<Tuple<string, byte[]>>();
|
||||
CheckValuesAufterBoot.Add(new Tuple<string, byte[]>("METROLOGYASST_PulseLength", Meter.ReadRegister("METROLOGYASST_PulseLength")));
|
||||
CheckValuesAufterBoot.Add(new Tuple<string, byte[]>("POWERMON_BatteryQuantity", Meter.ReadRegister("POWERMON_BatteryQuantity")));
|
||||
CheckValuesAufterBoot.Add(new Tuple<string, byte[]>("GENESISFLOW_MeterSize", Meter.ReadRegister("GENESISFLOW_MeterSize")));
|
||||
CheckValuesAufterBoot.Add(new Tuple<string, byte[]>("GENESISFLOW_CalFactor1", Meter.ReadRegister("GENESISFLOW_CalFactor1")));
|
||||
CheckValuesAufterBoot.Add(new Tuple<string, byte[]>("SENSUSRADIO_RadioAddress", Meter.ReadRegister("SENSUSRADIO_RadioAddress")));
|
||||
|
||||
bool? hasDiffrences = null;
|
||||
foreach (var item in CheckValuesAufterBoot)
|
||||
{
|
||||
if (!item.Item2.SequenceEqual(Meter.ReadRegister(item.Item1)))
|
||||
|
||||
var _meterResetPsu = new MeterResetPsu(Meter)
|
||||
{
|
||||
hasDiffrences = true;
|
||||
StoreConfigEnable = true
|
||||
};
|
||||
var rebootSucceeded = _meterResetPsu.MeterResetPsuExecute();
|
||||
var CheckValuesAufterBoot = new List<Tuple<string, byte[]>>();
|
||||
Thread.Sleep(10000);
|
||||
Meter.Login();
|
||||
CheckValuesAufterBoot.Add(new Tuple<string, byte[]>("METROLOGYASST_PulseLength", Meter.ReadRegister("METROLOGYASST_PulseLength")));
|
||||
CheckValuesAufterBoot.Add(new Tuple<string, byte[]>("POWERMON_BatteryQuantity", Meter.ReadRegister("POWERMON_BatteryQuantity")));
|
||||
CheckValuesAufterBoot.Add(new Tuple<string, byte[]>("GENESISFLOW_MeterSize", Meter.ReadRegister("GENESISFLOW_MeterSize")));
|
||||
CheckValuesAufterBoot.Add(new Tuple<string, byte[]>("GENESISFLOW_CalFactor1", Meter.ReadRegister("GENESISFLOW_CalFactor1")));
|
||||
CheckValuesAufterBoot.Add(new Tuple<string, byte[]>("SENSUSRADIO_RadioAddress", Meter.ReadRegister("SENSUSRADIO_RadioAddress")));
|
||||
|
||||
bool? hasDiffrences = null;
|
||||
foreach (var item in CheckValuesAufterBoot)
|
||||
{
|
||||
if (!item.Item2.SequenceEqual(Meter.ReadRegister(item.Item1)))
|
||||
{
|
||||
hasDiffrences = true;
|
||||
}
|
||||
else
|
||||
{
|
||||
if (!hasDiffrences.HasValue)
|
||||
{
|
||||
hasDiffrences = false;
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
if (rebootSucceeded && hasDiffrences.HasValue && !hasDiffrences.Value)
|
||||
{
|
||||
base.currentProcessState = ProductionProcessState.Done;
|
||||
}
|
||||
else
|
||||
{
|
||||
if (!hasDiffrences.HasValue)
|
||||
{
|
||||
hasDiffrences = false;
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
if (rebootSucceeded && hasDiffrences.HasValue && !hasDiffrences.Value)
|
||||
{
|
||||
base.currentProcessState = ProductionProcessState.Done;
|
||||
Meter.WriteLog("reboot compare failed");
|
||||
base.currentProcessState = ProductionProcessState.Error;
|
||||
}
|
||||
}
|
||||
else
|
||||
{
|
||||
Meter.WriteLog("reboot compare failed");
|
||||
base.currentProcessState = ProductionProcessState.Error;
|
||||
}
|
||||
base.currentProcessState = ProductionProcessState.Done;
|
||||
}
|
||||
|
||||
|
||||
}
|
||||
else
|
||||
{
|
||||
|
||||
Reference in New Issue