ReSharper: -CLR types introduced on GTB
This commit is contained in:
@@ -41,8 +41,8 @@ namespace CordonelAssemblyLine.Model
|
||||
NotifyPropertyChanged(nameof(Result));
|
||||
}
|
||||
}
|
||||
private string testerName;
|
||||
public string TesterName
|
||||
private String testerName;
|
||||
public String TesterName
|
||||
{
|
||||
get { return testerName; }
|
||||
set
|
||||
@@ -52,8 +52,8 @@ namespace CordonelAssemblyLine.Model
|
||||
}
|
||||
}
|
||||
|
||||
private bool inputIsEnabled = false;
|
||||
public bool InputIsEnabled
|
||||
private Boolean inputIsEnabled = false;
|
||||
public Boolean InputIsEnabled
|
||||
{
|
||||
get { return inputIsEnabled; }
|
||||
set
|
||||
@@ -63,16 +63,16 @@ namespace CordonelAssemblyLine.Model
|
||||
}
|
||||
}
|
||||
|
||||
private int intervalWithoutDetect = 1000;
|
||||
private int intervalWithDetect = 10000;
|
||||
private string _currentPcbID;
|
||||
private Int32 intervalWithoutDetect = 1000;
|
||||
private Int32 intervalWithDetect = 10000;
|
||||
private String _currentPcbID;
|
||||
private MeterBatch Batch = new MeterBatch();
|
||||
public GenesisMeter CurrentMeter { get; private set; }
|
||||
|
||||
public bool Locked { get; set; } = false;
|
||||
public int? StationID { get; set; } = null;
|
||||
private string toolTip;
|
||||
public string ToolTipInput
|
||||
public Boolean Locked { get; set; } = false;
|
||||
public Int32? StationID { get; set; } = null;
|
||||
private String toolTip;
|
||||
public String ToolTipInput
|
||||
{
|
||||
get
|
||||
{
|
||||
@@ -86,7 +86,7 @@ namespace CordonelAssemblyLine.Model
|
||||
}
|
||||
}
|
||||
|
||||
public string CurrentPcbID
|
||||
public String CurrentPcbID
|
||||
{
|
||||
get
|
||||
{
|
||||
@@ -99,8 +99,8 @@ namespace CordonelAssemblyLine.Model
|
||||
NotifyPropertyChanged(nameof(CurrentPcbID));
|
||||
}
|
||||
}
|
||||
private bool _currentPcbHasPressure;
|
||||
public bool CurrentPcbHasPressure
|
||||
private Boolean _currentPcbHasPressure;
|
||||
public Boolean CurrentPcbHasPressure
|
||||
{
|
||||
get
|
||||
{
|
||||
@@ -115,7 +115,7 @@ namespace CordonelAssemblyLine.Model
|
||||
}
|
||||
private Timer tmrAutoDetect;
|
||||
|
||||
public LeakViewModel(int slotNR, int? stationID = null)
|
||||
public LeakViewModel(Int32 slotNR, Int32? stationID = null)
|
||||
{
|
||||
_logger = NLogHelper.CreateOrGetLogger("ProductionUI");
|
||||
StationID = stationID;
|
||||
@@ -134,7 +134,7 @@ namespace CordonelAssemblyLine.Model
|
||||
|
||||
}
|
||||
|
||||
public bool isHydraulicStaion()
|
||||
public Boolean isHydraulicStaion()
|
||||
{
|
||||
|
||||
if (!StationID.HasValue || StationID.Value == 1)
|
||||
@@ -144,17 +144,17 @@ namespace CordonelAssemblyLine.Model
|
||||
return true;
|
||||
}
|
||||
private readonly ILogger _logger;
|
||||
private readonly int SlotNr;
|
||||
private readonly Int32 SlotNr;
|
||||
|
||||
public void Log(string txt)
|
||||
public void Log(String txt)
|
||||
{
|
||||
_logger?.Info(txt);
|
||||
}
|
||||
private bool Detect()
|
||||
private Boolean Detect()
|
||||
{
|
||||
|
||||
Log("Start Detect");
|
||||
bool hasDetect = false;
|
||||
Boolean hasDetect = false;
|
||||
if (string.IsNullOrEmpty(CurrentPcbID) || CurrentMeter == null)
|
||||
{
|
||||
Batch = new MeterBatch();
|
||||
@@ -170,7 +170,7 @@ namespace CordonelAssemblyLine.Model
|
||||
try
|
||||
{
|
||||
tryMeter.Login();
|
||||
var hasPresure = RegisterConverter.ConvertTo<bool>(tryMeter.ReadRegister("METROLOGYASST_PressurePresent"));
|
||||
var hasPresure = RegisterConverter.ConvertTo<Boolean>(tryMeter.ReadRegister("METROLOGYASST_PressurePresent"));
|
||||
CurrentPcbHasPressure = hasPresure;
|
||||
}
|
||||
catch (Exception ex)
|
||||
@@ -243,7 +243,7 @@ namespace CordonelAssemblyLine.Model
|
||||
DisposeAllConnections();
|
||||
}
|
||||
|
||||
public void TmrAutoDetect_Elapsed(object sender, EventArgs e)
|
||||
public void TmrAutoDetect_Elapsed(Object sender, EventArgs e)
|
||||
{
|
||||
tmrAutoDetect.Enabled = false;
|
||||
var hasDetect = Detect();
|
||||
@@ -257,13 +257,13 @@ namespace CordonelAssemblyLine.Model
|
||||
}
|
||||
tmrAutoDetect.Enabled = true;
|
||||
}
|
||||
internal void ReloadData(bool reset)
|
||||
internal void ReloadData(Boolean reset)
|
||||
{
|
||||
|
||||
if (Result != null && Result.PcbId != CurrentPcbID)
|
||||
{
|
||||
InputIsEnabled = false;
|
||||
Result = new PressureResultDataNotifyable() { Remark = "loading", Testpoints = new ObservableCollection<PressureTestPoints>(), PcbId = "" };
|
||||
Result = new PressureResultDataNotifyable() { Remark = "loading", TestPoints = new ObservableCollection<PressureTestPoints>(), PcbId = "" };
|
||||
Task<PressureResultDataNotifyable>.Run(() =>
|
||||
{
|
||||
try
|
||||
@@ -290,7 +290,7 @@ namespace CordonelAssemblyLine.Model
|
||||
PressureResultData = new PressureResultDataNotifyable();
|
||||
if (!CurrentPcbHasPressure)
|
||||
{
|
||||
PressureResultData.Testpoints.Remove(PressureResultData.Testpoints.First(r => r.Ident == 10));
|
||||
PressureResultData.TestPoints.Remove(PressureResultData.TestPoints.First(r => r.Ident == 10));
|
||||
}
|
||||
|
||||
|
||||
@@ -326,7 +326,7 @@ namespace CordonelAssemblyLine.Model
|
||||
}
|
||||
|
||||
|
||||
internal void StoreData(bool successfull)
|
||||
internal void StoreData(Boolean successfull)
|
||||
{
|
||||
|
||||
if (Result != null && Result.PcbId == CurrentPcbID)
|
||||
|
||||
@@ -21,154 +21,131 @@ using Xylem.Common.Utils.Logging;
|
||||
|
||||
namespace CordonelAssemblyLine.Model
|
||||
{
|
||||
internal class MarriageViewModel : INotifyPropertyChanged
|
||||
internal sealed class MarriageViewModel : INotifyPropertyChanged
|
||||
{
|
||||
public event EventHandler<string> OnMsgRaise;
|
||||
public MarriageViewModel(string scannerPort, int slotNr)
|
||||
public event EventHandler<String> OnMsgRaise;
|
||||
public MarriageViewModel(String scannerPort, Int32 slotNr)
|
||||
{
|
||||
_logger = NLogHelper.CreateOrGetLogger("ProductionUI");
|
||||
ScannerPort = scannerPort;
|
||||
SlotNr = slotNr;
|
||||
_scannerPort = scannerPort;
|
||||
_slotNr = slotNr;
|
||||
}
|
||||
|
||||
private readonly ILogger _logger;
|
||||
|
||||
private string state = "Warte auf Scanner";
|
||||
private string scanner = "keine Verbindung";
|
||||
private string slot = "-";
|
||||
private string result = "-";
|
||||
private String _stateMsg = "Warte auf Scanner";
|
||||
private String _scanner = "Keine Verbindung";
|
||||
private String _slot = "-";
|
||||
private String _result = "-";
|
||||
|
||||
private System.Windows.Media.Brush resultColor;
|
||||
private System.Windows.Media.Brush _resultColor;
|
||||
public System.Windows.Media.Brush ResultColor
|
||||
{
|
||||
get
|
||||
{
|
||||
return resultColor;
|
||||
}
|
||||
get => _resultColor;
|
||||
set
|
||||
{
|
||||
resultColor = value;
|
||||
NotifyPropertyChanged(nameof(ResultColor));
|
||||
_resultColor = value;
|
||||
NotifyPropertyChanged();
|
||||
}
|
||||
}
|
||||
public string State
|
||||
public String State
|
||||
{
|
||||
get
|
||||
{
|
||||
return state;
|
||||
}
|
||||
get => _stateMsg;
|
||||
set
|
||||
{
|
||||
state = value;
|
||||
NotifyPropertyChanged(nameof(State));
|
||||
_stateMsg = value;
|
||||
NotifyPropertyChanged();
|
||||
}
|
||||
}
|
||||
public string Scanner
|
||||
public String Scanner
|
||||
{
|
||||
get
|
||||
{
|
||||
return scanner;
|
||||
}
|
||||
get => _scanner;
|
||||
set
|
||||
{
|
||||
scanner = value;
|
||||
NotifyPropertyChanged(nameof(Scanner));
|
||||
_scanner = value;
|
||||
NotifyPropertyChanged();
|
||||
}
|
||||
}
|
||||
public string Slot
|
||||
public String Slot
|
||||
{
|
||||
get
|
||||
{
|
||||
return slot;
|
||||
}
|
||||
get => _slot;
|
||||
set
|
||||
{
|
||||
slot = value;
|
||||
NotifyPropertyChanged(nameof(Slot));
|
||||
_slot = value;
|
||||
NotifyPropertyChanged();
|
||||
}
|
||||
}
|
||||
public string SerialNr
|
||||
public String SerialNr
|
||||
{
|
||||
get
|
||||
{
|
||||
return serialNr;
|
||||
}
|
||||
get => _serialNr;
|
||||
set
|
||||
{
|
||||
serialNr = value;
|
||||
NotifyPropertyChanged(nameof(SerialNr));
|
||||
_serialNr = value;
|
||||
NotifyPropertyChanged();
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
public string Result
|
||||
public String Result
|
||||
{
|
||||
get
|
||||
{
|
||||
return result;
|
||||
}
|
||||
get => _result;
|
||||
set
|
||||
{
|
||||
result = value;
|
||||
NotifyPropertyChanged(nameof(Result));
|
||||
_result = value;
|
||||
NotifyPropertyChanged();
|
||||
}
|
||||
}
|
||||
|
||||
public bool CanMarry
|
||||
public Boolean CanMarry
|
||||
{
|
||||
get
|
||||
{
|
||||
return canMarry;
|
||||
}
|
||||
get => _canMarry;
|
||||
set
|
||||
{
|
||||
canMarry = value;
|
||||
NotifyPropertyChanged(nameof(CanMarry));
|
||||
_canMarry = value;
|
||||
NotifyPropertyChanged();
|
||||
}
|
||||
}
|
||||
|
||||
public string PcbId
|
||||
public String PcbId
|
||||
{
|
||||
get
|
||||
{
|
||||
return pcbId;
|
||||
}
|
||||
get => _pcbId;
|
||||
set
|
||||
{
|
||||
pcbId = value;
|
||||
NotifyPropertyChanged(nameof(PcbId));
|
||||
_pcbId = value;
|
||||
NotifyPropertyChanged();
|
||||
}
|
||||
}
|
||||
|
||||
private string pcbId;
|
||||
private bool canMarry = false;
|
||||
private String _pcbId;
|
||||
private Boolean _canMarry;
|
||||
|
||||
public event PropertyChangedEventHandler PropertyChanged;
|
||||
protected virtual void NotifyPropertyChanged([CallerMemberName] String propertyName = "")
|
||||
|
||||
private void NotifyPropertyChanged([CallerMemberName] String propertyName = "")
|
||||
{
|
||||
|
||||
PropertyChanged?.Invoke(this, new PropertyChangedEventArgs(propertyName));
|
||||
}
|
||||
Task s;
|
||||
private bool CloseTask = false;
|
||||
Task _s;
|
||||
private Boolean _closeTask;
|
||||
public void Dispose()
|
||||
{
|
||||
|
||||
while (!s.IsCompleted)
|
||||
while (!_s.IsCompleted)
|
||||
{
|
||||
CloseTask = true;
|
||||
_closeTask = true;
|
||||
}
|
||||
|
||||
|
||||
}
|
||||
public void StartStore()
|
||||
{
|
||||
sm = PickingStateMachine.Store;
|
||||
_state = PickingStateMachine.Store;
|
||||
}
|
||||
public void StartPicking(CancellationToken cancle)
|
||||
{
|
||||
s = new Task(() => { PickingLoop(cancle); }, cancle);
|
||||
s.Start();
|
||||
_s = new Task(() => { PickingLoop(cancle); }, cancle);
|
||||
_s.Start();
|
||||
}
|
||||
public enum PickingStateMachine
|
||||
{
|
||||
@@ -183,101 +160,98 @@ namespace CordonelAssemblyLine.Model
|
||||
Done,
|
||||
GetMappingMSG
|
||||
}
|
||||
private PickingStateMachine sm = PickingStateMachine.Init;
|
||||
private PickingStateMachine _state = PickingStateMachine.Init;
|
||||
|
||||
private class BarScanner : IDisposable
|
||||
{
|
||||
public bool? IsRuning = null;
|
||||
public Boolean? IsRuning;
|
||||
public String Input = "";
|
||||
private String Port;
|
||||
private CancellationToken Cancellation;
|
||||
private Task WaitForScannerTask;
|
||||
public BarScanner(string port, CancellationToken cancellation)
|
||||
private String _port;
|
||||
private CancellationToken _cancellation;
|
||||
private Task _waitForScannerTask;
|
||||
public BarScanner(String port, CancellationToken cancellation)
|
||||
{
|
||||
Port = port;
|
||||
Cancellation = cancellation;
|
||||
_port = port;
|
||||
_cancellation = cancellation;
|
||||
}
|
||||
public void Start()
|
||||
{
|
||||
if (!IsRuning.HasValue || !IsRuning.Value)
|
||||
{
|
||||
if (Port == null)
|
||||
if (_port == null)
|
||||
{
|
||||
return;
|
||||
}
|
||||
WaitForScannerTask = new Task(() =>
|
||||
_waitForScannerTask = new Task(() =>
|
||||
{
|
||||
try
|
||||
{
|
||||
using (var a = new SerialPort(Port))
|
||||
using (var a = new SerialPort(_port))
|
||||
{
|
||||
a.Open();
|
||||
a.NewLine = "\r";
|
||||
while (true)
|
||||
{
|
||||
if (Cancellation.IsCancellationRequested)
|
||||
if (_cancellation.IsCancellationRequested)
|
||||
{
|
||||
IsRuning = false;
|
||||
break;
|
||||
}
|
||||
else
|
||||
{
|
||||
IsRuning = true;
|
||||
Input = a.ReadLine();
|
||||
a.Close();
|
||||
IsRuning = false;
|
||||
break;
|
||||
}
|
||||
|
||||
IsRuning = true;
|
||||
Input = a.ReadLine();
|
||||
a.Close();
|
||||
IsRuning = false;
|
||||
break;
|
||||
}
|
||||
}
|
||||
}
|
||||
catch (Exception ex)
|
||||
catch (Exception)
|
||||
{
|
||||
IsRuning = false;
|
||||
|
||||
}
|
||||
|
||||
|
||||
}, Cancellation);
|
||||
WaitForScannerTask.Start();
|
||||
}, _cancellation);
|
||||
_waitForScannerTask.Start();
|
||||
}
|
||||
}
|
||||
|
||||
public void Dispose()
|
||||
{
|
||||
if (WaitForScannerTask.Status != TaskStatus.Faulted && WaitForScannerTask.Status != TaskStatus.RanToCompletion && WaitForScannerTask.Status != TaskStatus.Canceled)
|
||||
if (_waitForScannerTask.Status != TaskStatus.Faulted && _waitForScannerTask.Status != TaskStatus.RanToCompletion && _waitForScannerTask.Status != TaskStatus.Canceled)
|
||||
{
|
||||
WaitForScannerTask.Dispose();
|
||||
_waitForScannerTask.Dispose();
|
||||
}
|
||||
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
public bool Compare(Dictionary<UInt32, UInt32> checkAppsIdVersion, uint Frequency, uint MeterSize, bool PressurePresent)
|
||||
public Boolean Compare(Dictionary<UInt32, UInt32> checkAppsIdVersion, UInt32 frequency, UInt32 meterSize, Boolean pressurePresent)
|
||||
{
|
||||
using (var Batch = new MeterBatch())
|
||||
using (var batch = new MeterBatch())
|
||||
{
|
||||
|
||||
using (var meter = new GenesisMeter())
|
||||
{
|
||||
|
||||
meter.SetupFromConfigFile(SlotNr);
|
||||
Batch.AddMeter(meter);
|
||||
meter.SetupFromConfigFile(_slotNr);
|
||||
batch.AddMeter(meter);
|
||||
State = "Am Zähler anmelden";
|
||||
if ((bool)meter.Login())
|
||||
if (meter.Login())
|
||||
{
|
||||
meter.SetProcessState(Xylem.Common.Hardware.WaterMeter.WaterMeterCore.Consts.DisplayCodes.PickingStarted);
|
||||
var ret = RunCheck(checkAppsIdVersion, Frequency, MeterSize, PressurePresent, meter);
|
||||
meter.SetProcessState(DisplayCodes.PickingStarted);
|
||||
var ret = RunCheck(checkAppsIdVersion, frequency, meterSize, pressurePresent, meter);
|
||||
|
||||
if (ret)
|
||||
{
|
||||
meter.SetProcessState(Xylem.Common.Hardware.WaterMeter.WaterMeterCore.Consts.DisplayCodes.PickingTested);
|
||||
var url = $"{ServiceUrls.MeterProcessStateUrl()}SetPickingState?PcbID={meter.PcbId}&FertigungsauftragsNr={serialNr}";
|
||||
var RetString = LocalWebRequest.PostRequestAsyncAndGetContent(url);
|
||||
meter.SetProcessState(DisplayCodes.PickingTested);
|
||||
var url = $"{ServiceUrls.MeterProcessStateUrl()}SetPickingState?PcbID={meter.PcbId}&FertigungsauftragsNr={_serialNr}";
|
||||
var retString = LocalWebRequest.PostRequestAsyncAndGetContent(url);
|
||||
|
||||
var result = false;
|
||||
if (bool.TryParse(RetString, out result))
|
||||
if (bool.TryParse(retString, out var result))
|
||||
{
|
||||
return result;
|
||||
|
||||
@@ -285,7 +259,7 @@ namespace CordonelAssemblyLine.Model
|
||||
}
|
||||
else
|
||||
{
|
||||
meter.SetProcessState(Xylem.Common.Hardware.WaterMeter.WaterMeterCore.Consts.DisplayCodes.PickingFailed);
|
||||
meter.SetProcessState(DisplayCodes.PickingFailed);
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -293,34 +267,34 @@ namespace CordonelAssemblyLine.Model
|
||||
return false;
|
||||
}
|
||||
|
||||
private bool RunCheck(Dictionary<uint, uint> checkAppsIdVersion, uint Frequency, uint MeterSize, bool PressurePresent, GenesisMeter meter)
|
||||
private Boolean RunCheck(Dictionary<UInt32, UInt32> checkAppsIdVersion, UInt32 frequency, UInt32 meterSize, Boolean pressurePresent, GenesisMeter meter)
|
||||
{
|
||||
State = $"Üperprüfe Parameter";
|
||||
var FrequencyReadOut = RegisterConverter.ConvertTo<UInt32>(meter.ReadRegister("SENSUSRADIO_FrequencyIndicator"));
|
||||
if (FrequencyReadOut != Frequency)
|
||||
var frequencyReadOut = RegisterConverter.ConvertTo<UInt32>(meter.ReadRegister("SENSUSRADIO_FrequencyIndicator"));
|
||||
if (frequencyReadOut != frequency)
|
||||
{
|
||||
State = $"Falsche Frequenz! soll {Frequency}MHz ist {FrequencyReadOut}MHz";
|
||||
State = $"Falsche Frequenz! soll {frequency}MHz ist {frequencyReadOut}MHz";
|
||||
return false;
|
||||
}
|
||||
|
||||
var MeterSizeReadOut = RegisterConverter.ConvertTo<UInt32>(meter.ReadRegister("GENESISFLOW_MeterSize"));
|
||||
if (MeterSizeReadOut != MeterSize)
|
||||
var meterSizeReadOut = RegisterConverter.ConvertTo<UInt32>(meter.ReadRegister("GENESISFLOW_MeterSize"));
|
||||
if (meterSizeReadOut != meterSize)
|
||||
{
|
||||
State = $"Meter Dn falsch! soll {MeterSize}DN ist {MeterSizeReadOut}DN";
|
||||
State = $"Meter Dn falsch! soll {meterSize}DN ist {meterSizeReadOut}DN";
|
||||
return false;
|
||||
}
|
||||
|
||||
|
||||
var PressureReadOut = RegisterConverter.ConvertTo<bool>(meter.ReadRegister("METROLOGYASST_PressurePresent"));
|
||||
if (PressureReadOut != PressurePresent)
|
||||
var pressureReadOut = RegisterConverter.ConvertTo<Boolean>(meter.ReadRegister("METROLOGYASST_PressurePresent"));
|
||||
if (pressureReadOut != pressurePresent)
|
||||
{
|
||||
if (PressurePresent)
|
||||
if (pressurePresent)
|
||||
{
|
||||
State = $"Pcb mit Drucksensor. Laut Auftrag keine verbaut";
|
||||
State = "Pcb mit Drucksensor. Laut Auftrag ist keiner verbaut";
|
||||
}
|
||||
else
|
||||
{
|
||||
State = $"Pcb ohne Drucksensor. Laut Auftrag soll eine verbaut werden";
|
||||
State = "Pcb ohne Drucksensor. Laut Auftrag soll einer verbaut werden";
|
||||
}
|
||||
//todo raus
|
||||
return false;
|
||||
@@ -331,17 +305,17 @@ namespace CordonelAssemblyLine.Model
|
||||
|
||||
try
|
||||
{
|
||||
var MeterFWApp = meter.MeterAppListVersion.First(a => item.Key == a.AppId);
|
||||
if (MeterFWApp == null || MeterFWApp.Version != item.Value)
|
||||
var meterFWApp = meter.MeterAppListVersion.First(a => item.Key == a.AppId);
|
||||
if (meterFWApp.Version != item.Value)
|
||||
{
|
||||
State = $"Falsche FW, bitte Updaten";
|
||||
State = "Falsche FW, bitte Updaten";
|
||||
return false;
|
||||
}
|
||||
|
||||
}
|
||||
catch (Exception)
|
||||
{
|
||||
State = $"Fehler beim auslesen der FW";
|
||||
State = "Fehler beim auslesen der FW";
|
||||
return false;
|
||||
}
|
||||
|
||||
@@ -356,93 +330,91 @@ namespace CordonelAssemblyLine.Model
|
||||
var storeRet = meter.ReadRegister("METROLOGYASST_StoreConfiguration");
|
||||
if (!storeRet.All(a => a.Equals(0)))
|
||||
{
|
||||
State = $"Filesystem corrupt";
|
||||
State = "Filesystem corrupt";
|
||||
return false;
|
||||
}
|
||||
|
||||
}
|
||||
catch (Exception)
|
||||
{
|
||||
State = $"Fehler beim überprüfen des Filesystems";
|
||||
State = "Fehler beim überprüfen des Filesystems";
|
||||
return false;
|
||||
}
|
||||
|
||||
return true;
|
||||
}
|
||||
|
||||
private PickingCompareItem OrderDetails;
|
||||
private BarScanner barScanner;
|
||||
private string serialNr;
|
||||
//private PickingCompareItem _orderDetails;
|
||||
private BarScanner _barScanner;
|
||||
private String _serialNr;
|
||||
|
||||
|
||||
private bool RequestDetails = false;
|
||||
private readonly string ScannerPort;
|
||||
private readonly int SlotNr;
|
||||
private Boolean _requestDetails;
|
||||
private readonly String _scannerPort;
|
||||
private readonly Int32 _slotNr;
|
||||
//PickingState,PickingScanner,PickingSlot,PickingResult
|
||||
private void PickingLoop(CancellationToken token)
|
||||
{
|
||||
|
||||
|
||||
while (!token.IsCancellationRequested && !CloseTask)
|
||||
while (!token.IsCancellationRequested && !_closeTask)
|
||||
{
|
||||
switch (sm)
|
||||
switch (_state)
|
||||
{
|
||||
case PickingStateMachine.Init:
|
||||
CanMarry = false;
|
||||
State = "Initialisierung";
|
||||
Slot = $"Inaktiv EP {SlotNr}";
|
||||
Scanner = $"Geschlossen {ScannerPort}";
|
||||
Slot = $"Inaktiv EP {_slotNr}";
|
||||
Scanner = $"Geschlossen {_scannerPort}";
|
||||
//CheckAllPorts?
|
||||
Scanner = $"Öfffne {ScannerPort}";
|
||||
Scanner = $"Öfffne {_scannerPort}";
|
||||
//CheckAllPorts?
|
||||
barScanner = new BarScanner(ScannerPort, token);
|
||||
barScanner.Start();
|
||||
_barScanner = new BarScanner(_scannerPort, token);
|
||||
_barScanner.Start();
|
||||
|
||||
while (!barScanner.IsRuning.HasValue)
|
||||
while (!_barScanner.IsRuning.HasValue)
|
||||
{
|
||||
Thread.Sleep(50);
|
||||
}
|
||||
if (barScanner.IsRuning.HasValue && barScanner.IsRuning.Value)
|
||||
if (_barScanner.IsRuning.HasValue && _barScanner.IsRuning.Value)
|
||||
{
|
||||
Scanner = $"Offen {ScannerPort}";
|
||||
sm = PickingStateMachine.WaitForScanning;
|
||||
Scanner = $"Offen {_scannerPort}";
|
||||
_state = PickingStateMachine.WaitForScanning;
|
||||
}
|
||||
else
|
||||
{
|
||||
Scanner = $"Nicht geöffnet {ScannerPort}";
|
||||
sm = PickingStateMachine.Init;
|
||||
Scanner = $"Nicht geöffnet {_scannerPort}";
|
||||
_state = PickingStateMachine.Init;
|
||||
Thread.Sleep(5000);
|
||||
}
|
||||
|
||||
|
||||
break;
|
||||
case PickingStateMachine.WaitForScanning:
|
||||
OrderDetails = null;
|
||||
State = $"Warte auf Scannereingabe({ScannerPort})";
|
||||
if (barScanner != null && !String.IsNullOrEmpty(barScanner.Input))
|
||||
//_orderDetails = null;
|
||||
State = $"Warte auf Scannereingabe({_scannerPort})";
|
||||
if (_barScanner != null && !string.IsNullOrEmpty(_barScanner.Input))
|
||||
{
|
||||
if (RequestDetails)
|
||||
if (_requestDetails)
|
||||
{
|
||||
State = $"Abfrage ";
|
||||
PcbId = barScanner.Input;
|
||||
barScanner.Input = "";
|
||||
sm = PickingStateMachine.GetMappingMSG;
|
||||
PcbId = _barScanner.Input;
|
||||
_barScanner.Input = "";
|
||||
_state = PickingStateMachine.GetMappingMSG;
|
||||
}
|
||||
else
|
||||
{
|
||||
if (barScanner.Input.Contains("%RequestMapping%"))
|
||||
if (_barScanner.Input.Contains("%RequestMapping%"))
|
||||
{
|
||||
RequestDetails = true;
|
||||
_requestDetails = true;
|
||||
State = $"PCB ID scannen!";
|
||||
barScanner = new BarScanner(ScannerPort, token);
|
||||
barScanner.Start();
|
||||
_barScanner = new BarScanner(_scannerPort, token);
|
||||
_barScanner.Start();
|
||||
}
|
||||
else
|
||||
{
|
||||
SerialNr = barScanner.Input;
|
||||
Scanner = $"Geschlossen {ScannerPort}";
|
||||
barScanner = null;
|
||||
sm = PickingStateMachine.WaitForDetect;
|
||||
SerialNr = _barScanner.Input;
|
||||
Scanner = $"Geschlossen {_scannerPort}";
|
||||
_barScanner = null;
|
||||
_state = PickingStateMachine.WaitForDetect;
|
||||
}
|
||||
}
|
||||
|
||||
@@ -452,7 +424,7 @@ namespace CordonelAssemblyLine.Model
|
||||
|
||||
break;
|
||||
case PickingStateMachine.WaitForDetect:
|
||||
using (var Batch = new MeterBatch())
|
||||
using (var batch = new MeterBatch())
|
||||
{
|
||||
|
||||
using (var tryMeter = new GenesisMeter())
|
||||
@@ -460,9 +432,9 @@ namespace CordonelAssemblyLine.Model
|
||||
try
|
||||
{
|
||||
State = $"Warte auf Pcb";
|
||||
Slot = $"Öffne EP {SlotNr}";
|
||||
tryMeter.SetupFromConfigFile(SlotNr);
|
||||
Batch.AddMeter(tryMeter);
|
||||
Slot = $"Öffne EP {_slotNr}";
|
||||
tryMeter.SetupFromConfigFile(_slotNr);
|
||||
batch.AddMeter(tryMeter);
|
||||
tryMeter.Logout();
|
||||
Log("Try to get PcbID");
|
||||
PcbId = tryMeter.GetPcbId();
|
||||
@@ -473,11 +445,11 @@ namespace CordonelAssemblyLine.Model
|
||||
{
|
||||
State = $"Pcb gefunden {PcbId}";
|
||||
Log($"New PcbID detected {PcbId}");
|
||||
sm = PickingStateMachine.GetMapping;
|
||||
_state = PickingStateMachine.GetMapping;
|
||||
}
|
||||
else
|
||||
{
|
||||
Slot = $"Keine Konnektivität EP {SlotNr}";
|
||||
Slot = $"Keine Konnektivität EP {_slotNr}";
|
||||
Log($"No Meter found");
|
||||
}
|
||||
}
|
||||
@@ -492,95 +464,96 @@ namespace CordonelAssemblyLine.Model
|
||||
|
||||
case PickingStateMachine.GetMappingMSG:
|
||||
|
||||
State = $"Lade Auftragsdaten {serialNr}";
|
||||
var msgRetCode = 0;
|
||||
var msgStr = LocalWebRequest.GetRequestWithError($"{ServiceUrls.MarriageServiceUrl()}GetPreMarriageStateMSG?PcbId={PcbId}", out msgRetCode, 15000);
|
||||
State = $"Lade Auftragsdaten {_serialNr}";
|
||||
var msgStr = LocalWebRequest.GetRequestWithError($"{ServiceUrls.MarriageServiceUrl()}" +
|
||||
$"GetPreMarriageStateMSG?PcbId={PcbId}", out var msgRetCode, 15000);
|
||||
var msgRetInt = MarriagePossibleEnum.None;
|
||||
var sbMSG = new StringBuilder();
|
||||
var sbMsg = new StringBuilder();
|
||||
|
||||
|
||||
var myJsonResponse = Newtonsoft.Json.JsonConvert.DeserializeObject<object[]>(msgStr);
|
||||
string retOrder = myJsonResponse[1]?.ToString();
|
||||
string retSerial = myJsonResponse[2]?.ToString();
|
||||
string retFreeSrn = myJsonResponse[3]?.ToString();
|
||||
var myJsonResponse = Newtonsoft.Json.JsonConvert.DeserializeObject<Object[]>(msgStr);
|
||||
String retOrder = myJsonResponse[1]?.ToString();
|
||||
String retSerial = myJsonResponse[2]?.ToString();
|
||||
String retFreeSrn = myJsonResponse[3]?.ToString();
|
||||
|
||||
sbMSG.AppendLine($"Abfrage");
|
||||
sbMSG.AppendLine($"PCB Id: \t \t \t \t {PcbId}");
|
||||
sbMSG.AppendLine($"Aufrag: \t \t \t \t {retOrder}");
|
||||
sbMSG.AppendLine($"Seriennummer: \t \t \t \t {retSerial}");
|
||||
sbMSG.AppendLine($"Noch Verfügbare Seriennummern des Auftrages: \t {retFreeSrn}");
|
||||
sbMSG.AppendLine($"Zusätzliche Infos:");
|
||||
sbMsg.AppendLine($"Abfrage");
|
||||
sbMsg.AppendLine($"PCB Id: \t \t \t \t {PcbId}");
|
||||
sbMsg.AppendLine($"Aufrag: \t \t \t \t {retOrder}");
|
||||
sbMsg.AppendLine($"Seriennummer: \t \t \t \t {retSerial}");
|
||||
sbMsg.AppendLine($"Noch Verfügbare Seriennummern des Auftrages: \t {retFreeSrn}");
|
||||
sbMsg.AppendLine($"Zusätzliche Infos:");
|
||||
|
||||
if (msgRetCode != 200 || !MarriagePossibleEnum.TryParse(myJsonResponse[0].ToString(), out msgRetInt))
|
||||
if (msgRetCode != 200 || !Enum.TryParse(myJsonResponse[0].ToString(), out msgRetInt))
|
||||
{
|
||||
sbMSG.AppendLine($"Technisches Problem beim abfragen der Verfügbarkeit. Code ({msgRetCode})");
|
||||
sbMsg.AppendLine($"Technisches Problem beim abfragen der Verfügbarkeit. Code ({msgRetCode})");
|
||||
}
|
||||
|
||||
if (msgRetInt.HasFlag(MarriagePossibleEnum.NotPossibleDueToAlreadyMarried))
|
||||
{
|
||||
sbMSG.AppendLine($"Pcb ist schon mit der Seriennummer {retSerial} verbunden");
|
||||
sbMsg.AppendLine($"Pcb ist schon mit der Seriennummer {retSerial} verbunden");
|
||||
}
|
||||
if (msgRetInt.HasFlag(MarriagePossibleEnum.NotPossibleDuePcbLocked))
|
||||
{
|
||||
sbMSG.AppendLine("Pcb ist schon mit einer anderen Seriennummer verbunden.");
|
||||
sbMsg.AppendLine("Pcb ist schon mit einer anderen Seriennummer verbunden.");
|
||||
}
|
||||
if (msgRetInt.HasFlag(MarriagePossibleEnum.NotPossibleDueSerialNumberBlocked))
|
||||
{
|
||||
sbMSG.AppendLine("Seriennummer ist schon mit einer anderen Pcb verbunden.");
|
||||
sbMsg.AppendLine("Seriennummer ist schon mit einer anderen Pcb verbunden.");
|
||||
}
|
||||
if (msgRetInt.HasFlag(MarriagePossibleEnum.PcbNotMatchingOrder))
|
||||
{
|
||||
sbMSG.AppendLine("Die Pcb ist noch keinem Auftrag zugeordnet.");
|
||||
sbMsg.AppendLine("Die Pcb ist noch keinem Auftrag zugeordnet.");
|
||||
}
|
||||
if (msgRetInt.HasFlag(MarriagePossibleEnum.Error))
|
||||
{
|
||||
sbMSG.AppendLine("Ein unbestimmter Fehler ist aufgetreten.");
|
||||
sbMsg.AppendLine("Ein unbestimmter Fehler ist aufgetreten.");
|
||||
}
|
||||
if (msgRetInt.HasFlag(MarriagePossibleEnum.NotPossibleDueNoPressureTestFound))
|
||||
{
|
||||
sbMSG.AppendLine("Druck Test fehlt");
|
||||
sbMsg.AppendLine("Druck Test fehlt");
|
||||
}
|
||||
if (msgRetInt.HasFlag(MarriagePossibleEnum.NotPossibleDueNoHeTestFound))
|
||||
{
|
||||
sbMSG.AppendLine("Heliumtest fehlt");
|
||||
sbMsg.AppendLine("Heliumtest fehlt");
|
||||
}
|
||||
if (msgRetInt.HasFlag(MarriagePossibleEnum.Possible))
|
||||
{
|
||||
sbMSG.AppendLine("Verheiraten möglich");
|
||||
sbMsg.AppendLine("Verheiraten möglich");
|
||||
}
|
||||
|
||||
|
||||
|
||||
OnMsgRaise?.Invoke(this, sbMSG.ToString());
|
||||
sm = PickingStateMachine.WaitForScanning;
|
||||
OnMsgRaise?.Invoke(this, sbMsg.ToString());
|
||||
_state = PickingStateMachine.WaitForScanning;
|
||||
Log($"No Meter found");
|
||||
|
||||
break;
|
||||
case PickingStateMachine.GetMapping:
|
||||
|
||||
State = $"Lade Auftragsdaten {serialNr}";
|
||||
var retCode = 0;
|
||||
var str = LocalWebRequest.GetRequestWithError($"{ServiceUrls.MarriageServiceUrl()}GetPreMarriageState?SerialNumber={serialNr}&PcbId={PcbId}", out retCode, 15000);
|
||||
State = $"Lade Auftragsdaten {_serialNr}";
|
||||
var str = LocalWebRequest.GetRequestWithError(
|
||||
$"{ServiceUrls.MarriageServiceUrl()}GetPreMarriageState?SerialNumber=" +
|
||||
$"{_serialNr}&PcbId={PcbId}", out var retCode, 15000);
|
||||
var retInt = MarriagePossibleEnum.None;
|
||||
if (retCode != 200 || !MarriagePossibleEnum.TryParse(str, out retInt))
|
||||
if (retCode != 200 || !Enum.TryParse(str, out retInt))
|
||||
{
|
||||
OnMsgRaise?.Invoke(this, $"Technisches Problem beim abfragen der Verfügbarkeit. Code ({retCode})");
|
||||
sm = PickingStateMachine.MappingError;
|
||||
_state = PickingStateMachine.MappingError;
|
||||
}
|
||||
List<string> MappingText = new List<string>();
|
||||
List<String> mappingText = new List<String>();
|
||||
if (retInt.HasFlag(MarriagePossibleEnum.NotPossibleDueToAlreadyMarried))
|
||||
{
|
||||
MappingText.Add("Pcb ist schon mit dieser Seriennummer verbunden.Display aktualisiert");
|
||||
using (var Batch = new MeterBatch())
|
||||
mappingText.Add("Pcb ist schon mit dieser Seriennummer verbunden.Display aktualisiert");
|
||||
using (var batch = new MeterBatch())
|
||||
{
|
||||
using (var tryMeter = new GenesisMeter())
|
||||
{
|
||||
try
|
||||
{
|
||||
State = $"Warte auf Pcb";
|
||||
Slot = $"Öffne EP {SlotNr}";
|
||||
tryMeter.SetupFromConfigFile(SlotNr);
|
||||
Batch.AddMeter(tryMeter);
|
||||
Slot = $"Öffne EP {_slotNr}";
|
||||
tryMeter.SetupFromConfigFile(_slotNr);
|
||||
batch.AddMeter(tryMeter);
|
||||
tryMeter.Logout();
|
||||
Log("Try to get PcbID");
|
||||
PcbId = tryMeter.GetPcbId();
|
||||
@@ -595,11 +568,11 @@ namespace CordonelAssemblyLine.Model
|
||||
tryMeter.SetProcessState(DisplayCodes.Mounted);
|
||||
tryMeter.PushProgress("AssemblyLine", Assembly.GetExecutingAssembly().GetName().Version.ToString());
|
||||
|
||||
sm = PickingStateMachine.Done;
|
||||
_state = PickingStateMachine.Done;
|
||||
}
|
||||
else
|
||||
{
|
||||
Slot = $"Keine Konnektivität EP {SlotNr}";
|
||||
Slot = $"Keine Konnektivität EP {_slotNr}";
|
||||
Log($"No Meter found");
|
||||
}
|
||||
// OnMsgRaise?.Invoke(this, $"Zähler verheiratet. Kann zur Prüfstation");
|
||||
@@ -613,45 +586,45 @@ namespace CordonelAssemblyLine.Model
|
||||
}
|
||||
if (retInt.HasFlag(MarriagePossibleEnum.NotPossibleDuePcbLocked))
|
||||
{
|
||||
MappingText.Add("Pcb ist schon mit einer anderen Seriennummer verbunden.");
|
||||
mappingText.Add("Pcb ist schon mit einer anderen Seriennummer verbunden.");
|
||||
}
|
||||
if (retInt.HasFlag(MarriagePossibleEnum.NotPossibleDueSerialNumberBlocked))
|
||||
{
|
||||
MappingText.Add("Seriennummer ist schon mit einer anderen Pcb verbunden.");
|
||||
mappingText.Add("Seriennummer ist schon mit einer anderen Pcb verbunden.");
|
||||
}
|
||||
if (retInt.HasFlag(MarriagePossibleEnum.PcbNotMatchingOrder))
|
||||
{
|
||||
MappingText.Add("Die Pcb ist noch keinem Auftrag zugeordnet.");
|
||||
mappingText.Add("Die Pcb ist noch keinem Auftrag zugeordnet.");
|
||||
}
|
||||
if (retInt.HasFlag(MarriagePossibleEnum.Error))
|
||||
{
|
||||
MappingText.Add("Ein unbestimmter Fehler ist aufgetreten.");
|
||||
mappingText.Add("Ein unbestimmter Fehler ist aufgetreten.");
|
||||
}
|
||||
if (retInt.HasFlag(MarriagePossibleEnum.NotPossibleDueNoPressureTestFound))
|
||||
{
|
||||
MappingText.Add("Druck Test fehlt");
|
||||
mappingText.Add("Druck Test fehlt");
|
||||
}
|
||||
if (retInt.HasFlag(MarriagePossibleEnum.NotPossibleDueNoHeTestFound))
|
||||
{
|
||||
MappingText.Add("Heliumtest fehlt");
|
||||
mappingText.Add("Heliumtest fehlt");
|
||||
}
|
||||
|
||||
|
||||
|
||||
if (MappingText.Any())
|
||||
if (mappingText.Any())
|
||||
{
|
||||
var MsgText = "";
|
||||
foreach (var item in MappingText)
|
||||
var msgText = "";
|
||||
foreach (var item in mappingText)
|
||||
{
|
||||
MsgText = MsgText + Environment.NewLine + item;
|
||||
msgText = msgText + Environment.NewLine + item;
|
||||
}
|
||||
OnMsgRaise?.Invoke(this, $"Diese Kombination ist nicht möglich.{MsgText}");
|
||||
sm = PickingStateMachine.MappingError;
|
||||
OnMsgRaise?.Invoke(this, $"Diese Kombination ist nicht möglich.{msgText}");
|
||||
_state = PickingStateMachine.MappingError;
|
||||
Log($"No Meter found");
|
||||
}
|
||||
else
|
||||
{
|
||||
sm = PickingStateMachine.WaitForBuildingMeterReady;
|
||||
_state = PickingStateMachine.WaitForBuildingMeterReady;
|
||||
}
|
||||
|
||||
break;
|
||||
@@ -662,19 +635,18 @@ namespace CordonelAssemblyLine.Model
|
||||
State = $"Mapping nicht möglich, bitte erneut scannen";
|
||||
Log($"Mapping nicht möglich, bitte erneut scannen");
|
||||
Thread.Sleep(10000);
|
||||
sm = PickingStateMachine.Init;
|
||||
_state = PickingStateMachine.Init;
|
||||
break;
|
||||
case PickingStateMachine.Store:
|
||||
CanMarry = false;
|
||||
var url = $"{ServiceUrls.MarriageServiceUrl()}SetPcbToSerial?PcbId={PcbId}&Scan={serialNr}&returnMetroData=0";
|
||||
var url = $"{ServiceUrls.MarriageServiceUrl()}SetPcbToSerial?PcbId={PcbId}" +
|
||||
$"&Scan={_serialNr}&returnMetroData=0";
|
||||
try
|
||||
{
|
||||
string resp = "";
|
||||
String resp;
|
||||
try
|
||||
{
|
||||
resp = LocalWebRequest.GetRequest(url, 18000);
|
||||
|
||||
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
@@ -682,26 +654,21 @@ namespace CordonelAssemblyLine.Model
|
||||
{
|
||||
throw;
|
||||
}
|
||||
else
|
||||
{
|
||||
resp = "already store";
|
||||
}
|
||||
|
||||
resp = "already store";
|
||||
}
|
||||
|
||||
|
||||
if (resp.Trim().ToLower().Contains("store"))
|
||||
{
|
||||
using (var Batch = new MeterBatch())
|
||||
using (var batch = new MeterBatch())
|
||||
{
|
||||
using (var tryMeter = new GenesisMeter())
|
||||
{
|
||||
try
|
||||
{
|
||||
State = $"Warte auf Pcb";
|
||||
Slot = $"Öffne EP {SlotNr}";
|
||||
tryMeter.SetupFromConfigFile(SlotNr);
|
||||
Batch.AddMeter(tryMeter);
|
||||
Slot = $"Öffne EP {_slotNr}";
|
||||
tryMeter.SetupFromConfigFile(_slotNr);
|
||||
batch.AddMeter(tryMeter);
|
||||
tryMeter.Logout();
|
||||
Log("Try to get PcbID");
|
||||
PcbId = tryMeter.GetPcbId();
|
||||
@@ -716,11 +683,11 @@ namespace CordonelAssemblyLine.Model
|
||||
tryMeter.SetProcessState(DisplayCodes.Mounted);
|
||||
tryMeter.PushProgress("AssemblyLine", Assembly.GetExecutingAssembly().GetName().Version.ToString());
|
||||
|
||||
sm = PickingStateMachine.Done;
|
||||
_state = PickingStateMachine.Done;
|
||||
}
|
||||
else
|
||||
{
|
||||
Slot = $"Keine Konnektivität EP {SlotNr}";
|
||||
Slot = $"Keine Konnektivität EP {_slotNr}";
|
||||
Log($"No Meter found");
|
||||
}
|
||||
OnMsgRaise?.Invoke(this, $"Zähler verheiratet. Kann zur Prüfstation");
|
||||
@@ -736,7 +703,7 @@ namespace CordonelAssemblyLine.Model
|
||||
{
|
||||
OnMsgRaise?.Invoke(this, $"Fehler beim Speichern, bitte Support Kontaktieren.Response{resp}");
|
||||
}
|
||||
sm = PickingStateMachine.Init;
|
||||
_state = PickingStateMachine.Init;
|
||||
|
||||
}
|
||||
catch (Exception ex)
|
||||
@@ -754,9 +721,7 @@ namespace CordonelAssemblyLine.Model
|
||||
break;
|
||||
case PickingStateMachine.Done:
|
||||
OnMsgRaise?.Invoke(this, $"Bitte Display überprüfen. {Environment.NewLine}Sollte etwas anderes als {DisplayCodes.Mounted} im Display erscheinen ist der Zähler nicht erfolgreich bearbeitet.");
|
||||
sm = PickingStateMachine.Init;
|
||||
break;
|
||||
default:
|
||||
_state = PickingStateMachine.Init;
|
||||
break;
|
||||
}
|
||||
Thread.Sleep(1000);
|
||||
@@ -765,7 +730,7 @@ namespace CordonelAssemblyLine.Model
|
||||
|
||||
}
|
||||
|
||||
public void Log(string txt)
|
||||
public void Log(String txt)
|
||||
{
|
||||
_logger?.Info(txt);
|
||||
}
|
||||
|
||||
@@ -844,8 +844,7 @@ namespace CordonelAssemblyLine.Model
|
||||
|
||||
var storeRet = meter.ReadRegister("METROLOGYASST_StoreConfiguration");
|
||||
|
||||
//TODO THW what to hell is this exclusion ?
|
||||
if (meter.PcbId != "18440026" && meter.PcbId != "193300058" && meter.PcbId != "194800276" && meter.PcbId != "201420255" && !storeRet.All(a => a.Equals(0)))
|
||||
if (!storeRet.All(a => a.Equals(0)))
|
||||
{
|
||||
lblS07Text = "Filesystem corrupt";
|
||||
SetState("Filesystem corrupt");
|
||||
@@ -1113,9 +1112,14 @@ namespace CordonelAssemblyLine.Model
|
||||
|
||||
lblS09Color = _progressCurrent;
|
||||
|
||||
//TODO THW check why -9 months at 5 devices and else -3 months
|
||||
minDate = minDate.AddMonths(_orderOverview.OrderOverViewCordonel.Count < 5 ? -9 : -3);
|
||||
SetState($"Register wurde am {_orderOverview.KitronProductionDate } hergestellt, für diesen Auftrag muss das Register nach dem {minDate} hergestellt worden sein");
|
||||
|
||||
//Rule from J.Schulz, 9 months for customers with immediately usage here temporary decided on order volume
|
||||
//minDate = minDate.AddMonths(_orderOverview.OrderOverViewCordonel.Count < 5 ? -9 : -3);
|
||||
|
||||
// The production date has to be at least within the last 3 months from now backwards
|
||||
minDate = minDate.AddMonths(-3);
|
||||
SetState($"Register wurde am {_orderOverview.KitronProductionDate } hergestellt, für diesen Auftrag " +
|
||||
$"muss das Register nach dem {minDate} hergestellt worden sein");
|
||||
lblS09Text = $"{_orderOverview.KitronProductionDate}";
|
||||
|
||||
//TODO may be useful to introduce SkipRegisterOldness instead of SkipBatteyCheck will be used for oldness of register
|
||||
|
||||
Reference in New Issue
Block a user