ReSharper: -CLR types introduced on GTB

This commit is contained in:
Thomas Wiedebusch
2022-10-19 12:58:08 +02:00
parent 561b46a580
commit b4d5330d1d
120 changed files with 1908 additions and 1897 deletions
@@ -41,8 +41,8 @@ namespace CordonelAssemblyLine.Model
NotifyPropertyChanged(nameof(Result));
}
}
private string testerName;
public string TesterName
private String testerName;
public String TesterName
{
get { return testerName; }
set
@@ -52,8 +52,8 @@ namespace CordonelAssemblyLine.Model
}
}
private bool inputIsEnabled = false;
public bool InputIsEnabled
private Boolean inputIsEnabled = false;
public Boolean InputIsEnabled
{
get { return inputIsEnabled; }
set
@@ -63,16 +63,16 @@ namespace CordonelAssemblyLine.Model
}
}
private int intervalWithoutDetect = 1000;
private int intervalWithDetect = 10000;
private string _currentPcbID;
private Int32 intervalWithoutDetect = 1000;
private Int32 intervalWithDetect = 10000;
private String _currentPcbID;
private MeterBatch Batch = new MeterBatch();
public GenesisMeter CurrentMeter { get; private set; }
public bool Locked { get; set; } = false;
public int? StationID { get; set; } = null;
private string toolTip;
public string ToolTipInput
public Boolean Locked { get; set; } = false;
public Int32? StationID { get; set; } = null;
private String toolTip;
public String ToolTipInput
{
get
{
@@ -86,7 +86,7 @@ namespace CordonelAssemblyLine.Model
}
}
public string CurrentPcbID
public String CurrentPcbID
{
get
{
@@ -99,8 +99,8 @@ namespace CordonelAssemblyLine.Model
NotifyPropertyChanged(nameof(CurrentPcbID));
}
}
private bool _currentPcbHasPressure;
public bool CurrentPcbHasPressure
private Boolean _currentPcbHasPressure;
public Boolean CurrentPcbHasPressure
{
get
{
@@ -115,7 +115,7 @@ namespace CordonelAssemblyLine.Model
}
private Timer tmrAutoDetect;
public LeakViewModel(int slotNR, int? stationID = null)
public LeakViewModel(Int32 slotNR, Int32? stationID = null)
{
_logger = NLogHelper.CreateOrGetLogger("ProductionUI");
StationID = stationID;
@@ -134,7 +134,7 @@ namespace CordonelAssemblyLine.Model
}
public bool isHydraulicStaion()
public Boolean isHydraulicStaion()
{
if (!StationID.HasValue || StationID.Value == 1)
@@ -144,17 +144,17 @@ namespace CordonelAssemblyLine.Model
return true;
}
private readonly ILogger _logger;
private readonly int SlotNr;
private readonly Int32 SlotNr;
public void Log(string txt)
public void Log(String txt)
{
_logger?.Info(txt);
}
private bool Detect()
private Boolean Detect()
{
Log("Start Detect");
bool hasDetect = false;
Boolean hasDetect = false;
if (string.IsNullOrEmpty(CurrentPcbID) || CurrentMeter == null)
{
Batch = new MeterBatch();
@@ -170,7 +170,7 @@ namespace CordonelAssemblyLine.Model
try
{
tryMeter.Login();
var hasPresure = RegisterConverter.ConvertTo<bool>(tryMeter.ReadRegister("METROLOGYASST_PressurePresent"));
var hasPresure = RegisterConverter.ConvertTo<Boolean>(tryMeter.ReadRegister("METROLOGYASST_PressurePresent"));
CurrentPcbHasPressure = hasPresure;
}
catch (Exception ex)
@@ -243,7 +243,7 @@ namespace CordonelAssemblyLine.Model
DisposeAllConnections();
}
public void TmrAutoDetect_Elapsed(object sender, EventArgs e)
public void TmrAutoDetect_Elapsed(Object sender, EventArgs e)
{
tmrAutoDetect.Enabled = false;
var hasDetect = Detect();
@@ -257,13 +257,13 @@ namespace CordonelAssemblyLine.Model
}
tmrAutoDetect.Enabled = true;
}
internal void ReloadData(bool reset)
internal void ReloadData(Boolean reset)
{
if (Result != null && Result.PcbId != CurrentPcbID)
{
InputIsEnabled = false;
Result = new PressureResultDataNotifyable() { Remark = "loading", Testpoints = new ObservableCollection<PressureTestPoints>(), PcbId = "" };
Result = new PressureResultDataNotifyable() { Remark = "loading", TestPoints = new ObservableCollection<PressureTestPoints>(), PcbId = "" };
Task<PressureResultDataNotifyable>.Run(() =>
{
try
@@ -290,7 +290,7 @@ namespace CordonelAssemblyLine.Model
PressureResultData = new PressureResultDataNotifyable();
if (!CurrentPcbHasPressure)
{
PressureResultData.Testpoints.Remove(PressureResultData.Testpoints.First(r => r.Ident == 10));
PressureResultData.TestPoints.Remove(PressureResultData.TestPoints.First(r => r.Ident == 10));
}
@@ -326,7 +326,7 @@ namespace CordonelAssemblyLine.Model
}
internal void StoreData(bool successfull)
internal void StoreData(Boolean successfull)
{
if (Result != null && Result.PcbId == CurrentPcbID)
@@ -21,154 +21,131 @@ using Xylem.Common.Utils.Logging;
namespace CordonelAssemblyLine.Model
{
internal class MarriageViewModel : INotifyPropertyChanged
internal sealed class MarriageViewModel : INotifyPropertyChanged
{
public event EventHandler<string> OnMsgRaise;
public MarriageViewModel(string scannerPort, int slotNr)
public event EventHandler<String> OnMsgRaise;
public MarriageViewModel(String scannerPort, Int32 slotNr)
{
_logger = NLogHelper.CreateOrGetLogger("ProductionUI");
ScannerPort = scannerPort;
SlotNr = slotNr;
_scannerPort = scannerPort;
_slotNr = slotNr;
}
private readonly ILogger _logger;
private string state = "Warte auf Scanner";
private string scanner = "keine Verbindung";
private string slot = "-";
private string result = "-";
private String _stateMsg = "Warte auf Scanner";
private String _scanner = "Keine Verbindung";
private String _slot = "-";
private String _result = "-";
private System.Windows.Media.Brush resultColor;
private System.Windows.Media.Brush _resultColor;
public System.Windows.Media.Brush ResultColor
{
get
{
return resultColor;
}
get => _resultColor;
set
{
resultColor = value;
NotifyPropertyChanged(nameof(ResultColor));
_resultColor = value;
NotifyPropertyChanged();
}
}
public string State
public String State
{
get
{
return state;
}
get => _stateMsg;
set
{
state = value;
NotifyPropertyChanged(nameof(State));
_stateMsg = value;
NotifyPropertyChanged();
}
}
public string Scanner
public String Scanner
{
get
{
return scanner;
}
get => _scanner;
set
{
scanner = value;
NotifyPropertyChanged(nameof(Scanner));
_scanner = value;
NotifyPropertyChanged();
}
}
public string Slot
public String Slot
{
get
{
return slot;
}
get => _slot;
set
{
slot = value;
NotifyPropertyChanged(nameof(Slot));
_slot = value;
NotifyPropertyChanged();
}
}
public string SerialNr
public String SerialNr
{
get
{
return serialNr;
}
get => _serialNr;
set
{
serialNr = value;
NotifyPropertyChanged(nameof(SerialNr));
_serialNr = value;
NotifyPropertyChanged();
}
}
public string Result
public String Result
{
get
{
return result;
}
get => _result;
set
{
result = value;
NotifyPropertyChanged(nameof(Result));
_result = value;
NotifyPropertyChanged();
}
}
public bool CanMarry
public Boolean CanMarry
{
get
{
return canMarry;
}
get => _canMarry;
set
{
canMarry = value;
NotifyPropertyChanged(nameof(CanMarry));
_canMarry = value;
NotifyPropertyChanged();
}
}
public string PcbId
public String PcbId
{
get
{
return pcbId;
}
get => _pcbId;
set
{
pcbId = value;
NotifyPropertyChanged(nameof(PcbId));
_pcbId = value;
NotifyPropertyChanged();
}
}
private string pcbId;
private bool canMarry = false;
private String _pcbId;
private Boolean _canMarry;
public event PropertyChangedEventHandler PropertyChanged;
protected virtual void NotifyPropertyChanged([CallerMemberName] String propertyName = "")
private void NotifyPropertyChanged([CallerMemberName] String propertyName = "")
{
PropertyChanged?.Invoke(this, new PropertyChangedEventArgs(propertyName));
}
Task s;
private bool CloseTask = false;
Task _s;
private Boolean _closeTask;
public void Dispose()
{
while (!s.IsCompleted)
while (!_s.IsCompleted)
{
CloseTask = true;
_closeTask = true;
}
}
public void StartStore()
{
sm = PickingStateMachine.Store;
_state = PickingStateMachine.Store;
}
public void StartPicking(CancellationToken cancle)
{
s = new Task(() => { PickingLoop(cancle); }, cancle);
s.Start();
_s = new Task(() => { PickingLoop(cancle); }, cancle);
_s.Start();
}
public enum PickingStateMachine
{
@@ -183,101 +160,98 @@ namespace CordonelAssemblyLine.Model
Done,
GetMappingMSG
}
private PickingStateMachine sm = PickingStateMachine.Init;
private PickingStateMachine _state = PickingStateMachine.Init;
private class BarScanner : IDisposable
{
public bool? IsRuning = null;
public Boolean? IsRuning;
public String Input = "";
private String Port;
private CancellationToken Cancellation;
private Task WaitForScannerTask;
public BarScanner(string port, CancellationToken cancellation)
private String _port;
private CancellationToken _cancellation;
private Task _waitForScannerTask;
public BarScanner(String port, CancellationToken cancellation)
{
Port = port;
Cancellation = cancellation;
_port = port;
_cancellation = cancellation;
}
public void Start()
{
if (!IsRuning.HasValue || !IsRuning.Value)
{
if (Port == null)
if (_port == null)
{
return;
}
WaitForScannerTask = new Task(() =>
_waitForScannerTask = new Task(() =>
{
try
{
using (var a = new SerialPort(Port))
using (var a = new SerialPort(_port))
{
a.Open();
a.NewLine = "\r";
while (true)
{
if (Cancellation.IsCancellationRequested)
if (_cancellation.IsCancellationRequested)
{
IsRuning = false;
break;
}
else
{
IsRuning = true;
Input = a.ReadLine();
a.Close();
IsRuning = false;
break;
}
IsRuning = true;
Input = a.ReadLine();
a.Close();
IsRuning = false;
break;
}
}
}
catch (Exception ex)
catch (Exception)
{
IsRuning = false;
}
}, Cancellation);
WaitForScannerTask.Start();
}, _cancellation);
_waitForScannerTask.Start();
}
}
public void Dispose()
{
if (WaitForScannerTask.Status != TaskStatus.Faulted && WaitForScannerTask.Status != TaskStatus.RanToCompletion && WaitForScannerTask.Status != TaskStatus.Canceled)
if (_waitForScannerTask.Status != TaskStatus.Faulted && _waitForScannerTask.Status != TaskStatus.RanToCompletion && _waitForScannerTask.Status != TaskStatus.Canceled)
{
WaitForScannerTask.Dispose();
_waitForScannerTask.Dispose();
}
}
}
public bool Compare(Dictionary<UInt32, UInt32> checkAppsIdVersion, uint Frequency, uint MeterSize, bool PressurePresent)
public Boolean Compare(Dictionary<UInt32, UInt32> checkAppsIdVersion, UInt32 frequency, UInt32 meterSize, Boolean pressurePresent)
{
using (var Batch = new MeterBatch())
using (var batch = new MeterBatch())
{
using (var meter = new GenesisMeter())
{
meter.SetupFromConfigFile(SlotNr);
Batch.AddMeter(meter);
meter.SetupFromConfigFile(_slotNr);
batch.AddMeter(meter);
State = "Am Zähler anmelden";
if ((bool)meter.Login())
if (meter.Login())
{
meter.SetProcessState(Xylem.Common.Hardware.WaterMeter.WaterMeterCore.Consts.DisplayCodes.PickingStarted);
var ret = RunCheck(checkAppsIdVersion, Frequency, MeterSize, PressurePresent, meter);
meter.SetProcessState(DisplayCodes.PickingStarted);
var ret = RunCheck(checkAppsIdVersion, frequency, meterSize, pressurePresent, meter);
if (ret)
{
meter.SetProcessState(Xylem.Common.Hardware.WaterMeter.WaterMeterCore.Consts.DisplayCodes.PickingTested);
var url = $"{ServiceUrls.MeterProcessStateUrl()}SetPickingState?PcbID={meter.PcbId}&FertigungsauftragsNr={serialNr}";
var RetString = LocalWebRequest.PostRequestAsyncAndGetContent(url);
meter.SetProcessState(DisplayCodes.PickingTested);
var url = $"{ServiceUrls.MeterProcessStateUrl()}SetPickingState?PcbID={meter.PcbId}&FertigungsauftragsNr={_serialNr}";
var retString = LocalWebRequest.PostRequestAsyncAndGetContent(url);
var result = false;
if (bool.TryParse(RetString, out result))
if (bool.TryParse(retString, out var result))
{
return result;
@@ -285,7 +259,7 @@ namespace CordonelAssemblyLine.Model
}
else
{
meter.SetProcessState(Xylem.Common.Hardware.WaterMeter.WaterMeterCore.Consts.DisplayCodes.PickingFailed);
meter.SetProcessState(DisplayCodes.PickingFailed);
}
}
}
@@ -293,34 +267,34 @@ namespace CordonelAssemblyLine.Model
return false;
}
private bool RunCheck(Dictionary<uint, uint> checkAppsIdVersion, uint Frequency, uint MeterSize, bool PressurePresent, GenesisMeter meter)
private Boolean RunCheck(Dictionary<UInt32, UInt32> checkAppsIdVersion, UInt32 frequency, UInt32 meterSize, Boolean pressurePresent, GenesisMeter meter)
{
State = $"Üperprüfe Parameter";
var FrequencyReadOut = RegisterConverter.ConvertTo<UInt32>(meter.ReadRegister("SENSUSRADIO_FrequencyIndicator"));
if (FrequencyReadOut != Frequency)
var frequencyReadOut = RegisterConverter.ConvertTo<UInt32>(meter.ReadRegister("SENSUSRADIO_FrequencyIndicator"));
if (frequencyReadOut != frequency)
{
State = $"Falsche Frequenz! soll {Frequency}MHz ist {FrequencyReadOut}MHz";
State = $"Falsche Frequenz! soll {frequency}MHz ist {frequencyReadOut}MHz";
return false;
}
var MeterSizeReadOut = RegisterConverter.ConvertTo<UInt32>(meter.ReadRegister("GENESISFLOW_MeterSize"));
if (MeterSizeReadOut != MeterSize)
var meterSizeReadOut = RegisterConverter.ConvertTo<UInt32>(meter.ReadRegister("GENESISFLOW_MeterSize"));
if (meterSizeReadOut != meterSize)
{
State = $"Meter Dn falsch! soll {MeterSize}DN ist {MeterSizeReadOut}DN";
State = $"Meter Dn falsch! soll {meterSize}DN ist {meterSizeReadOut}DN";
return false;
}
var PressureReadOut = RegisterConverter.ConvertTo<bool>(meter.ReadRegister("METROLOGYASST_PressurePresent"));
if (PressureReadOut != PressurePresent)
var pressureReadOut = RegisterConverter.ConvertTo<Boolean>(meter.ReadRegister("METROLOGYASST_PressurePresent"));
if (pressureReadOut != pressurePresent)
{
if (PressurePresent)
if (pressurePresent)
{
State = $"Pcb mit Drucksensor. Laut Auftrag keine verbaut";
State = "Pcb mit Drucksensor. Laut Auftrag ist keiner verbaut";
}
else
{
State = $"Pcb ohne Drucksensor. Laut Auftrag soll eine verbaut werden";
State = "Pcb ohne Drucksensor. Laut Auftrag soll einer verbaut werden";
}
//todo raus
return false;
@@ -331,17 +305,17 @@ namespace CordonelAssemblyLine.Model
try
{
var MeterFWApp = meter.MeterAppListVersion.First(a => item.Key == a.AppId);
if (MeterFWApp == null || MeterFWApp.Version != item.Value)
var meterFWApp = meter.MeterAppListVersion.First(a => item.Key == a.AppId);
if (meterFWApp.Version != item.Value)
{
State = $"Falsche FW, bitte Updaten";
State = "Falsche FW, bitte Updaten";
return false;
}
}
catch (Exception)
{
State = $"Fehler beim auslesen der FW";
State = "Fehler beim auslesen der FW";
return false;
}
@@ -356,93 +330,91 @@ namespace CordonelAssemblyLine.Model
var storeRet = meter.ReadRegister("METROLOGYASST_StoreConfiguration");
if (!storeRet.All(a => a.Equals(0)))
{
State = $"Filesystem corrupt";
State = "Filesystem corrupt";
return false;
}
}
catch (Exception)
{
State = $"Fehler beim überprüfen des Filesystems";
State = "Fehler beim überprüfen des Filesystems";
return false;
}
return true;
}
private PickingCompareItem OrderDetails;
private BarScanner barScanner;
private string serialNr;
//private PickingCompareItem _orderDetails;
private BarScanner _barScanner;
private String _serialNr;
private bool RequestDetails = false;
private readonly string ScannerPort;
private readonly int SlotNr;
private Boolean _requestDetails;
private readonly String _scannerPort;
private readonly Int32 _slotNr;
//PickingState,PickingScanner,PickingSlot,PickingResult
private void PickingLoop(CancellationToken token)
{
while (!token.IsCancellationRequested && !CloseTask)
while (!token.IsCancellationRequested && !_closeTask)
{
switch (sm)
switch (_state)
{
case PickingStateMachine.Init:
CanMarry = false;
State = "Initialisierung";
Slot = $"Inaktiv EP {SlotNr}";
Scanner = $"Geschlossen {ScannerPort}";
Slot = $"Inaktiv EP {_slotNr}";
Scanner = $"Geschlossen {_scannerPort}";
//CheckAllPorts?
Scanner = $"Öfffne {ScannerPort}";
Scanner = $"Öfffne {_scannerPort}";
//CheckAllPorts?
barScanner = new BarScanner(ScannerPort, token);
barScanner.Start();
_barScanner = new BarScanner(_scannerPort, token);
_barScanner.Start();
while (!barScanner.IsRuning.HasValue)
while (!_barScanner.IsRuning.HasValue)
{
Thread.Sleep(50);
}
if (barScanner.IsRuning.HasValue && barScanner.IsRuning.Value)
if (_barScanner.IsRuning.HasValue && _barScanner.IsRuning.Value)
{
Scanner = $"Offen {ScannerPort}";
sm = PickingStateMachine.WaitForScanning;
Scanner = $"Offen {_scannerPort}";
_state = PickingStateMachine.WaitForScanning;
}
else
{
Scanner = $"Nicht geöffnet {ScannerPort}";
sm = PickingStateMachine.Init;
Scanner = $"Nicht geöffnet {_scannerPort}";
_state = PickingStateMachine.Init;
Thread.Sleep(5000);
}
break;
case PickingStateMachine.WaitForScanning:
OrderDetails = null;
State = $"Warte auf Scannereingabe({ScannerPort})";
if (barScanner != null && !String.IsNullOrEmpty(barScanner.Input))
//_orderDetails = null;
State = $"Warte auf Scannereingabe({_scannerPort})";
if (_barScanner != null && !string.IsNullOrEmpty(_barScanner.Input))
{
if (RequestDetails)
if (_requestDetails)
{
State = $"Abfrage ";
PcbId = barScanner.Input;
barScanner.Input = "";
sm = PickingStateMachine.GetMappingMSG;
PcbId = _barScanner.Input;
_barScanner.Input = "";
_state = PickingStateMachine.GetMappingMSG;
}
else
{
if (barScanner.Input.Contains("%RequestMapping%"))
if (_barScanner.Input.Contains("%RequestMapping%"))
{
RequestDetails = true;
_requestDetails = true;
State = $"PCB ID scannen!";
barScanner = new BarScanner(ScannerPort, token);
barScanner.Start();
_barScanner = new BarScanner(_scannerPort, token);
_barScanner.Start();
}
else
{
SerialNr = barScanner.Input;
Scanner = $"Geschlossen {ScannerPort}";
barScanner = null;
sm = PickingStateMachine.WaitForDetect;
SerialNr = _barScanner.Input;
Scanner = $"Geschlossen {_scannerPort}";
_barScanner = null;
_state = PickingStateMachine.WaitForDetect;
}
}
@@ -452,7 +424,7 @@ namespace CordonelAssemblyLine.Model
break;
case PickingStateMachine.WaitForDetect:
using (var Batch = new MeterBatch())
using (var batch = new MeterBatch())
{
using (var tryMeter = new GenesisMeter())
@@ -460,9 +432,9 @@ namespace CordonelAssemblyLine.Model
try
{
State = $"Warte auf Pcb";
Slot = $"Öffne EP {SlotNr}";
tryMeter.SetupFromConfigFile(SlotNr);
Batch.AddMeter(tryMeter);
Slot = $"Öffne EP {_slotNr}";
tryMeter.SetupFromConfigFile(_slotNr);
batch.AddMeter(tryMeter);
tryMeter.Logout();
Log("Try to get PcbID");
PcbId = tryMeter.GetPcbId();
@@ -473,11 +445,11 @@ namespace CordonelAssemblyLine.Model
{
State = $"Pcb gefunden {PcbId}";
Log($"New PcbID detected {PcbId}");
sm = PickingStateMachine.GetMapping;
_state = PickingStateMachine.GetMapping;
}
else
{
Slot = $"Keine Konnektivität EP {SlotNr}";
Slot = $"Keine Konnektivität EP {_slotNr}";
Log($"No Meter found");
}
}
@@ -492,95 +464,96 @@ namespace CordonelAssemblyLine.Model
case PickingStateMachine.GetMappingMSG:
State = $"Lade Auftragsdaten {serialNr}";
var msgRetCode = 0;
var msgStr = LocalWebRequest.GetRequestWithError($"{ServiceUrls.MarriageServiceUrl()}GetPreMarriageStateMSG?PcbId={PcbId}", out msgRetCode, 15000);
State = $"Lade Auftragsdaten {_serialNr}";
var msgStr = LocalWebRequest.GetRequestWithError($"{ServiceUrls.MarriageServiceUrl()}" +
$"GetPreMarriageStateMSG?PcbId={PcbId}", out var msgRetCode, 15000);
var msgRetInt = MarriagePossibleEnum.None;
var sbMSG = new StringBuilder();
var sbMsg = new StringBuilder();
var myJsonResponse = Newtonsoft.Json.JsonConvert.DeserializeObject<object[]>(msgStr);
string retOrder = myJsonResponse[1]?.ToString();
string retSerial = myJsonResponse[2]?.ToString();
string retFreeSrn = myJsonResponse[3]?.ToString();
var myJsonResponse = Newtonsoft.Json.JsonConvert.DeserializeObject<Object[]>(msgStr);
String retOrder = myJsonResponse[1]?.ToString();
String retSerial = myJsonResponse[2]?.ToString();
String retFreeSrn = myJsonResponse[3]?.ToString();
sbMSG.AppendLine($"Abfrage");
sbMSG.AppendLine($"PCB Id: \t \t \t \t {PcbId}");
sbMSG.AppendLine($"Aufrag: \t \t \t \t {retOrder}");
sbMSG.AppendLine($"Seriennummer: \t \t \t \t {retSerial}");
sbMSG.AppendLine($"Noch Verfügbare Seriennummern des Auftrages: \t {retFreeSrn}");
sbMSG.AppendLine($"Zusätzliche Infos:");
sbMsg.AppendLine($"Abfrage");
sbMsg.AppendLine($"PCB Id: \t \t \t \t {PcbId}");
sbMsg.AppendLine($"Aufrag: \t \t \t \t {retOrder}");
sbMsg.AppendLine($"Seriennummer: \t \t \t \t {retSerial}");
sbMsg.AppendLine($"Noch Verfügbare Seriennummern des Auftrages: \t {retFreeSrn}");
sbMsg.AppendLine($"Zusätzliche Infos:");
if (msgRetCode != 200 || !MarriagePossibleEnum.TryParse(myJsonResponse[0].ToString(), out msgRetInt))
if (msgRetCode != 200 || !Enum.TryParse(myJsonResponse[0].ToString(), out msgRetInt))
{
sbMSG.AppendLine($"Technisches Problem beim abfragen der Verfügbarkeit. Code ({msgRetCode})");
sbMsg.AppendLine($"Technisches Problem beim abfragen der Verfügbarkeit. Code ({msgRetCode})");
}
if (msgRetInt.HasFlag(MarriagePossibleEnum.NotPossibleDueToAlreadyMarried))
{
sbMSG.AppendLine($"Pcb ist schon mit der Seriennummer {retSerial} verbunden");
sbMsg.AppendLine($"Pcb ist schon mit der Seriennummer {retSerial} verbunden");
}
if (msgRetInt.HasFlag(MarriagePossibleEnum.NotPossibleDuePcbLocked))
{
sbMSG.AppendLine("Pcb ist schon mit einer anderen Seriennummer verbunden.");
sbMsg.AppendLine("Pcb ist schon mit einer anderen Seriennummer verbunden.");
}
if (msgRetInt.HasFlag(MarriagePossibleEnum.NotPossibleDueSerialNumberBlocked))
{
sbMSG.AppendLine("Seriennummer ist schon mit einer anderen Pcb verbunden.");
sbMsg.AppendLine("Seriennummer ist schon mit einer anderen Pcb verbunden.");
}
if (msgRetInt.HasFlag(MarriagePossibleEnum.PcbNotMatchingOrder))
{
sbMSG.AppendLine("Die Pcb ist noch keinem Auftrag zugeordnet.");
sbMsg.AppendLine("Die Pcb ist noch keinem Auftrag zugeordnet.");
}
if (msgRetInt.HasFlag(MarriagePossibleEnum.Error))
{
sbMSG.AppendLine("Ein unbestimmter Fehler ist aufgetreten.");
sbMsg.AppendLine("Ein unbestimmter Fehler ist aufgetreten.");
}
if (msgRetInt.HasFlag(MarriagePossibleEnum.NotPossibleDueNoPressureTestFound))
{
sbMSG.AppendLine("Druck Test fehlt");
sbMsg.AppendLine("Druck Test fehlt");
}
if (msgRetInt.HasFlag(MarriagePossibleEnum.NotPossibleDueNoHeTestFound))
{
sbMSG.AppendLine("Heliumtest fehlt");
sbMsg.AppendLine("Heliumtest fehlt");
}
if (msgRetInt.HasFlag(MarriagePossibleEnum.Possible))
{
sbMSG.AppendLine("Verheiraten möglich");
sbMsg.AppendLine("Verheiraten möglich");
}
OnMsgRaise?.Invoke(this, sbMSG.ToString());
sm = PickingStateMachine.WaitForScanning;
OnMsgRaise?.Invoke(this, sbMsg.ToString());
_state = PickingStateMachine.WaitForScanning;
Log($"No Meter found");
break;
case PickingStateMachine.GetMapping:
State = $"Lade Auftragsdaten {serialNr}";
var retCode = 0;
var str = LocalWebRequest.GetRequestWithError($"{ServiceUrls.MarriageServiceUrl()}GetPreMarriageState?SerialNumber={serialNr}&PcbId={PcbId}", out retCode, 15000);
State = $"Lade Auftragsdaten {_serialNr}";
var str = LocalWebRequest.GetRequestWithError(
$"{ServiceUrls.MarriageServiceUrl()}GetPreMarriageState?SerialNumber=" +
$"{_serialNr}&PcbId={PcbId}", out var retCode, 15000);
var retInt = MarriagePossibleEnum.None;
if (retCode != 200 || !MarriagePossibleEnum.TryParse(str, out retInt))
if (retCode != 200 || !Enum.TryParse(str, out retInt))
{
OnMsgRaise?.Invoke(this, $"Technisches Problem beim abfragen der Verfügbarkeit. Code ({retCode})");
sm = PickingStateMachine.MappingError;
_state = PickingStateMachine.MappingError;
}
List<string> MappingText = new List<string>();
List<String> mappingText = new List<String>();
if (retInt.HasFlag(MarriagePossibleEnum.NotPossibleDueToAlreadyMarried))
{
MappingText.Add("Pcb ist schon mit dieser Seriennummer verbunden.Display aktualisiert");
using (var Batch = new MeterBatch())
mappingText.Add("Pcb ist schon mit dieser Seriennummer verbunden.Display aktualisiert");
using (var batch = new MeterBatch())
{
using (var tryMeter = new GenesisMeter())
{
try
{
State = $"Warte auf Pcb";
Slot = $"Öffne EP {SlotNr}";
tryMeter.SetupFromConfigFile(SlotNr);
Batch.AddMeter(tryMeter);
Slot = $"Öffne EP {_slotNr}";
tryMeter.SetupFromConfigFile(_slotNr);
batch.AddMeter(tryMeter);
tryMeter.Logout();
Log("Try to get PcbID");
PcbId = tryMeter.GetPcbId();
@@ -595,11 +568,11 @@ namespace CordonelAssemblyLine.Model
tryMeter.SetProcessState(DisplayCodes.Mounted);
tryMeter.PushProgress("AssemblyLine", Assembly.GetExecutingAssembly().GetName().Version.ToString());
sm = PickingStateMachine.Done;
_state = PickingStateMachine.Done;
}
else
{
Slot = $"Keine Konnektivität EP {SlotNr}";
Slot = $"Keine Konnektivität EP {_slotNr}";
Log($"No Meter found");
}
// OnMsgRaise?.Invoke(this, $"Zähler verheiratet. Kann zur Prüfstation");
@@ -613,45 +586,45 @@ namespace CordonelAssemblyLine.Model
}
if (retInt.HasFlag(MarriagePossibleEnum.NotPossibleDuePcbLocked))
{
MappingText.Add("Pcb ist schon mit einer anderen Seriennummer verbunden.");
mappingText.Add("Pcb ist schon mit einer anderen Seriennummer verbunden.");
}
if (retInt.HasFlag(MarriagePossibleEnum.NotPossibleDueSerialNumberBlocked))
{
MappingText.Add("Seriennummer ist schon mit einer anderen Pcb verbunden.");
mappingText.Add("Seriennummer ist schon mit einer anderen Pcb verbunden.");
}
if (retInt.HasFlag(MarriagePossibleEnum.PcbNotMatchingOrder))
{
MappingText.Add("Die Pcb ist noch keinem Auftrag zugeordnet.");
mappingText.Add("Die Pcb ist noch keinem Auftrag zugeordnet.");
}
if (retInt.HasFlag(MarriagePossibleEnum.Error))
{
MappingText.Add("Ein unbestimmter Fehler ist aufgetreten.");
mappingText.Add("Ein unbestimmter Fehler ist aufgetreten.");
}
if (retInt.HasFlag(MarriagePossibleEnum.NotPossibleDueNoPressureTestFound))
{
MappingText.Add("Druck Test fehlt");
mappingText.Add("Druck Test fehlt");
}
if (retInt.HasFlag(MarriagePossibleEnum.NotPossibleDueNoHeTestFound))
{
MappingText.Add("Heliumtest fehlt");
mappingText.Add("Heliumtest fehlt");
}
if (MappingText.Any())
if (mappingText.Any())
{
var MsgText = "";
foreach (var item in MappingText)
var msgText = "";
foreach (var item in mappingText)
{
MsgText = MsgText + Environment.NewLine + item;
msgText = msgText + Environment.NewLine + item;
}
OnMsgRaise?.Invoke(this, $"Diese Kombination ist nicht möglich.{MsgText}");
sm = PickingStateMachine.MappingError;
OnMsgRaise?.Invoke(this, $"Diese Kombination ist nicht möglich.{msgText}");
_state = PickingStateMachine.MappingError;
Log($"No Meter found");
}
else
{
sm = PickingStateMachine.WaitForBuildingMeterReady;
_state = PickingStateMachine.WaitForBuildingMeterReady;
}
break;
@@ -662,19 +635,18 @@ namespace CordonelAssemblyLine.Model
State = $"Mapping nicht möglich, bitte erneut scannen";
Log($"Mapping nicht möglich, bitte erneut scannen");
Thread.Sleep(10000);
sm = PickingStateMachine.Init;
_state = PickingStateMachine.Init;
break;
case PickingStateMachine.Store:
CanMarry = false;
var url = $"{ServiceUrls.MarriageServiceUrl()}SetPcbToSerial?PcbId={PcbId}&Scan={serialNr}&returnMetroData=0";
var url = $"{ServiceUrls.MarriageServiceUrl()}SetPcbToSerial?PcbId={PcbId}" +
$"&Scan={_serialNr}&returnMetroData=0";
try
{
string resp = "";
String resp;
try
{
resp = LocalWebRequest.GetRequest(url, 18000);
}
catch (Exception ex)
{
@@ -682,26 +654,21 @@ namespace CordonelAssemblyLine.Model
{
throw;
}
else
{
resp = "already store";
}
resp = "already store";
}
if (resp.Trim().ToLower().Contains("store"))
{
using (var Batch = new MeterBatch())
using (var batch = new MeterBatch())
{
using (var tryMeter = new GenesisMeter())
{
try
{
State = $"Warte auf Pcb";
Slot = $"Öffne EP {SlotNr}";
tryMeter.SetupFromConfigFile(SlotNr);
Batch.AddMeter(tryMeter);
Slot = $"Öffne EP {_slotNr}";
tryMeter.SetupFromConfigFile(_slotNr);
batch.AddMeter(tryMeter);
tryMeter.Logout();
Log("Try to get PcbID");
PcbId = tryMeter.GetPcbId();
@@ -716,11 +683,11 @@ namespace CordonelAssemblyLine.Model
tryMeter.SetProcessState(DisplayCodes.Mounted);
tryMeter.PushProgress("AssemblyLine", Assembly.GetExecutingAssembly().GetName().Version.ToString());
sm = PickingStateMachine.Done;
_state = PickingStateMachine.Done;
}
else
{
Slot = $"Keine Konnektivität EP {SlotNr}";
Slot = $"Keine Konnektivität EP {_slotNr}";
Log($"No Meter found");
}
OnMsgRaise?.Invoke(this, $"Zähler verheiratet. Kann zur Prüfstation");
@@ -736,7 +703,7 @@ namespace CordonelAssemblyLine.Model
{
OnMsgRaise?.Invoke(this, $"Fehler beim Speichern, bitte Support Kontaktieren.Response{resp}");
}
sm = PickingStateMachine.Init;
_state = PickingStateMachine.Init;
}
catch (Exception ex)
@@ -754,9 +721,7 @@ namespace CordonelAssemblyLine.Model
break;
case PickingStateMachine.Done:
OnMsgRaise?.Invoke(this, $"Bitte Display überprüfen. {Environment.NewLine}Sollte etwas anderes als {DisplayCodes.Mounted} im Display erscheinen ist der Zähler nicht erfolgreich bearbeitet.");
sm = PickingStateMachine.Init;
break;
default:
_state = PickingStateMachine.Init;
break;
}
Thread.Sleep(1000);
@@ -765,7 +730,7 @@ namespace CordonelAssemblyLine.Model
}
public void Log(string txt)
public void Log(String txt)
{
_logger?.Info(txt);
}
@@ -844,8 +844,7 @@ namespace CordonelAssemblyLine.Model
var storeRet = meter.ReadRegister("METROLOGYASST_StoreConfiguration");
//TODO THW what to hell is this exclusion ?
if (meter.PcbId != "18440026" && meter.PcbId != "193300058" && meter.PcbId != "194800276" && meter.PcbId != "201420255" && !storeRet.All(a => a.Equals(0)))
if (!storeRet.All(a => a.Equals(0)))
{
lblS07Text = "Filesystem corrupt";
SetState("Filesystem corrupt");
@@ -1113,9 +1112,14 @@ namespace CordonelAssemblyLine.Model
lblS09Color = _progressCurrent;
//TODO THW check why -9 months at 5 devices and else -3 months
minDate = minDate.AddMonths(_orderOverview.OrderOverViewCordonel.Count < 5 ? -9 : -3);
SetState($"Register wurde am {_orderOverview.KitronProductionDate } hergestellt, für diesen Auftrag muss das Register nach dem {minDate} hergestellt worden sein");
//Rule from J.Schulz, 9 months for customers with immediately usage here temporary decided on order volume
//minDate = minDate.AddMonths(_orderOverview.OrderOverViewCordonel.Count < 5 ? -9 : -3);
// The production date has to be at least within the last 3 months from now backwards
minDate = minDate.AddMonths(-3);
SetState($"Register wurde am {_orderOverview.KitronProductionDate } hergestellt, für diesen Auftrag " +
$"muss das Register nach dem {minDate} hergestellt worden sein");
lblS09Text = $"{_orderOverview.KitronProductionDate}";
//TODO may be useful to introduce SkipRegisterOldness instead of SkipBatteyCheck will be used for oldness of register