ProductionUiCordonel: - manually merged some modules from main EOL_2.6.20

This commit is contained in:
Thomas Wiedebusch
2025-05-15 15:43:07 +02:00
parent 66f457dc0b
commit a5eabc2322
13 changed files with 3496 additions and 80 deletions
@@ -27,7 +27,7 @@ namespace Xylem.Common.Hardware.Interfaces.Ports.SerialPorts
/// <summary>
/// The port is not assigned.
/// </summary>
public const String PortNotAssigned = "NA";
public const String PortNotAssigned = "NA";
/// <inheritdoc />
public virtual event EventHandler<BasePortDataEventArgs> OnRawRecordSendOut;
@@ -193,6 +193,9 @@ namespace Xylem.Common.Hardware.Interfaces.Ports.SerialPorts
/// <summary>
/// Dispose serial port
/// </summary>
/// <remarks date="2025-Mai-12..14" author="T.Wiedebusch">
/// - Dispose procedure changed.
/// </remarks>
public void Dispose()
{
try
@@ -206,6 +209,9 @@ namespace Xylem.Common.Hardware.Interfaces.Ports.SerialPorts
//Run thread again to notice CancellationToken has changed
_onSyncReceiveThread.Set();
// dispose directly called from here to overcome glitches caused by USB to serial interface
_serialPort.Dispose();
}
catch (Exception ex)
@@ -419,6 +425,9 @@ namespace Xylem.Common.Hardware.Interfaces.Ports.SerialPorts
/// The IrDA sniffer showed these on the communication line, but they are incompletely received.
/// Assuming the DiscardInBuffer may be delayed, so the incoming data will be scrapped.
/// </remarks>
/// <remarks date="2025-Mai-12..14" author="T.Wiedebusch">
/// - Dispose procedure changed.
/// </remarks>
private void ReadingThreadLoop()
{
//put the receive thread to JoinWaitSleep to avoid reading and logger output for timeout on
@@ -448,8 +457,9 @@ namespace Xylem.Common.Hardware.Interfaces.Ports.SerialPorts
if (SyncMarkRecord.SkipDecoding != dataSyncMarkThisRun)
{
OnRawRecordReceived?.Invoke(this, new StringPortDataEventArgs(rxStringRecord,
_receiveTimeStampPc, dataSyncMarkThisRun));
_receiveTimeStampPc, dataSyncMarkThisRun));
}
if (RecordStreamingRawData)
{
AsciiDataLogger.Trace($"{rxStringRecord}");
@@ -503,12 +513,14 @@ namespace Xylem.Common.Hardware.Interfaces.Ports.SerialPorts
if (PortSettingsForTransmitProtocol.DoubleSyncByte)
{
if (rxByte.Equals(PortSettingsForTransmitProtocol.ProtSyncByte) &&
rxByteRecord[rxByteRecord.Count - 1].Equals(PortSettingsForTransmitProtocol.ProtSyncByte))
rxByteRecord[rxByteRecord.Count - 1]
.Equals(PortSettingsForTransmitProtocol.ProtSyncByte))
{
//skips this byte and read the next one
rxByte = (Byte)_serialPort.ReadByte();
}
}
//add byte to receive result buffer
rxByteRecord.Add(rxByte);
@@ -552,7 +564,9 @@ namespace Xylem.Common.Hardware.Interfaces.Ports.SerialPorts
}
}
catch (ThreadAbortException)
{ throw; }
{
_byteDataLogger.Info($"{Ident} Thread abort exception fired!");
}
catch (TimeoutException)
{
//ATTENTION: This "_serialPort.DiscardInBuffer()" caused a lot of trouble as it flushes a few incoming
@@ -575,12 +589,12 @@ namespace Xylem.Common.Hardware.Interfaces.Ports.SerialPorts
if (_receiveThread.ThreadState == ThreadState.Aborted
|| _receiveThread.ThreadState == ThreadState.AbortRequested)
{
_byteDataLogger.Warn(ex, $"{ Ident} ThreadState is Aborted or AbortRequested but an " +
"error occurred while reading records from serial port");
_byteDataLogger.Warn(ex, $"{Ident} ThreadState is Aborted or AbortRequested but an " +
"error occurred while reading records from serial port");
}
else
{
_byteDataLogger.Error(ex, $"{ Ident} Error while reading records from serial port");
_byteDataLogger.Error(ex, $"{Ident} Error while reading records from serial port");
}
}
finally
@@ -598,31 +612,33 @@ namespace Xylem.Common.Hardware.Interfaces.Ports.SerialPorts
}
}
}
}//while (!_tokenReadData.IsCancellationRequested)
}// over hole reading thread loop
} //while (!_tokenReadData.IsCancellationRequested)
} // over hole reading thread loop
catch (ThreadAbortException)
{ }
{
_byteDataLogger.Info($"{Ident} Thread abort exception fired!");
}
catch (Exception ex)
{
_byteDataLogger.Error($"{Ident} {ex.Message}");
}
finally
{
if (_serialPort.IsOpen)
{
_serialPort.Close();
if (_serialPort.IsOpen)
{
_byteDataLogger.Info($"{Ident} Port close delay!");
Thread.Sleep(50);
_serialPort.Close();
}
_serialPort.Dispose();
_byteDataLogger.Info($"{Ident} Port is closed");
}
}
//finally
//{
// //var retries = 5;
// //while (_serialPort != null && _serialPort.IsOpen && retries-- > 0)
// //{
// // _serialPort.Close();
// // if (_serialPort.IsOpen)
// // {
// // _byteDataLogger.Info($"{Ident} Port closing delay!");
// // Thread.Sleep(500);
// // }
// //}
// //if (_serialPort != null && _serialPort.IsOpen)
// // _byteDataLogger.Info($"{Ident} Port unable to close");
// //else
// // _byteDataLogger.Info($"{Ident} Port is closed");
//}
}
/// <inheritdoc />
@@ -0,0 +1,693 @@
using NLog;
using System;
using System.Collections.Generic;
using System.IO.Ports;
using System.Threading;
using Xylem.Common.CommonCore.Consts;
using Xylem.Common.CommonCore.ThreadWatcher;
using Xylem.Common.Hardware.Interfaces.Ports.PortCore;
using Xylem.Common.Hardware.Interfaces.Ports.PortCore.EventArguments;
using Xylem.Common.Utils.Logging;
namespace Xylem.Common.Hardware.Interfaces.Ports.SerialPorts
{
/// <summary>
/// All Ports must use BasePort as an base class
/// its support some wrapping event/function handling
/// </summary>
public abstract class BaseSerialPort : IPort, IDisposable
{
private ILogger _byteDataLogger;
internal ILogger AsciiDataLogger;
/// <inheritdoc />
public virtual event EventHandler<BasePortDataEventArgs> OnRawRecordReceived;
/// <summary>
/// The port is not assigned.
/// </summary>
public const String PortNotAssigned = "NA";
/// <inheritdoc />
public virtual event EventHandler<BasePortDataEventArgs> OnRawRecordSendOut;
//initially do not signal event
private readonly AutoResetEvent _onSyncReceiveThread = new AutoResetEvent(false);
private readonly Thread _receiveThread;
private readonly CancellationTokenSource _receiveToken = new CancellationTokenSource();
/// <summary>
/// Delay between bytes if receiving has started in milliseconds
/// </summary>
private const Int32 InterByteReadDelayMs = 50;
/// <summary>
/// internal SerialPort class
/// </summary>
private readonly SerialPort _serialPort;
/// <summary>
/// Activate raw record recording
/// </summary>
public Boolean RecordStreamingRawData = false;
//public Boolean RecordStreamingRawData
//{
// get => _recordStreamingRawData;
// set => _recordStreamingRawData = value;
//}
/// <summary>
/// date and time of incoming first date interrupt on serial IO to set the
/// PC time-stamp to the record
/// </summary>
private DateTimeOffset _receiveTimeStampPc;
/// <summary>
/// Individual port settings depending on transmit protocol
/// </summary>
protected TransmitPortSettings PortSettingsForTransmitProtocol;
/// <inheritdoc />
public String GetPortName()
{
return _serialPort.PortName;
}
/// <summary>
/// store a identification of a port, this contains the Slot, Port, Protocol and Type
/// e.g. "Slot:1, Port:COM4, Protocol:Request, Type:IrDA -"
/// </summary>
public String Ident;
/// <summary>
/// ctor for SerialComPort with and full constructed <see cref="T:System.IO.Ports.SerialPort" /> properties
/// </summary>
/// <param name="ident">set port as unique</param>
/// <param name="serialPort">Class for communication, all parameters for serial communication needs to be set</param>
/// <param name="setting">Class for store all parameters for serial communication needs to be set came from transmit protocol</param>
protected BaseSerialPort(String ident, SerialPort serialPort, TransmitPortSettings setting)
{
Ident = ident;
//communication port settings
_serialPort = serialPort;
_serialPort.BaudRate = (Int32)setting.BaudRate;
PortSettingsForTransmitProtocol = setting;
//assign thread to loop
_receiveThread = new Thread(ReadingThreadLoop) { Name = $"{Ident} Reading thread" };
AsciiDataLogger = NLogHelper.CreateOrGetMultiLogger(Ident, "", "LedRawData", "TargetLedRawDataBase", "LedRawDataBase");
_byteDataLogger = NLogHelper.CreateOrGetMultiLogger(Ident, "", "UartSerialPort", "COMBase", "BaseSerialPort");
}
public void RefreshLogger()
{
AsciiDataLogger = NLogHelper.CreateOrGetMultiLogger(Ident, "", "LedRawData", "TargetLedRawDataBase", "LedRawDataBase");
_byteDataLogger = NLogHelper.CreateOrGetMultiLogger(Ident, "", "UartSerialPort", "COMBase", "BaseSerialPort");
}
/// <summary>
/// received bytes in buffer of SerialComPort, calls base function
/// </summary>
/// <returns>number of bytes in Rx buffer</returns>
protected Int32 BytesToRead()
{
try
{
return _serialPort.BytesToRead;
}
catch (Exception ex)
{
_byteDataLogger.Error(ex);
return 0;
}
}
/// <summary>
/// read single byte from Rx buffer of SerialComPort, calls base function
/// </summary>
/// <returns></returns>
protected Int32 ReadByte()
{
try
{
return _serialPort.ReadByte();
}
catch (Exception ex)
{
_byteDataLogger.Error(ex);
return 0;
}
}
/// <inheritdoc />
public void PortWrite(Byte[] record)
{
try
{
SpecificPortWrite(record);
}
catch (Exception ex)
{
throw new SystemException($"{Ident} Communication error while sending data to port", ex);
}
}
/// <inheritdoc />
/// <summary>
/// flush Rx and Tx buffer of SerialComPort, calls base functions
/// </summary>
public void Clear()
{
try
{
if (!_serialPort.IsOpen)
{
return;
}
_serialPort.DiscardInBuffer();
_serialPort.DiscardOutBuffer();
}
catch (Exception ex)
{
_byteDataLogger.Error(ex);
}
}
/// <summary>
/// Dispose serial port
/// </summary>
public void Dispose()
{
try
{
//remove registration for receive delegate
_serialPort.DataReceived -= PhysicalDataReceived;
//Cancel send and receive tokens
_receiveToken.Cancel();
//Run thread again to notice CancellationToken has changed
_onSyncReceiveThread.Set();
}
catch (Exception ex)
{
_byteDataLogger.Error(ex);
}
}
/// <inheritdoc />
public void Open()
{
try
{
//set receive interrupt threshold for immediate execution
_serialPort.ReceivedBytesThreshold = 1;
_serialPort.DataReceived += PhysicalDataReceived;
//start reading thread, will be immediately put to waitSleepJoin in ReadingThreadLoop
//to avoid side effects with RFID communication
ThreadWatcher.Instance.Start(_receiveThread);
if (!_serialPort.IsOpen)
{
_serialPort.Open();
if (!_serialPort.IsOpen)
{
_byteDataLogger.Error($"{Ident} Port cannot be opened");
throw new ApplicationException($"{Ident} Port cannot be opened");
}
_byteDataLogger.Info($"{Ident} Port is opened");
}
else
{
_byteDataLogger.Warn($"{Ident} Port was already opened");
}
}
catch (Exception ex)
{
_byteDataLogger.Error($"{Ident} {ex.Message}");
throw new ApplicationException($"{Ident} {ex.Message}");
}
}
/// <summary>
/// Getting the base port
/// </summary>
protected SerialPort GetBaseComport()
{
return _serialPort;
}
/// <summary>
/// Fill FIFO with received data
/// </summary>
/// <remarks date="2018-Feb-16" author="T.Wiedebusch">
/// - Initial
/// </remarks>
/// <remarks date="2018-Feb-21" author="T.Wiedebusch">
/// - Time stamp added
/// </remarks>
/// <remarks date="2018-Dec-14" author="T.Wiedebusch">
/// - Timeout moved from <see cref="ReadingThreadLoop"/> to PhysicalDataReceived to avoid
/// <see cref="TimeoutException"/> of serial port while waiting on first incoming
/// data.
/// </remarks>
/// <remarks date="2019-Dec-12" author="T.Wiedebusch">
/// - Inter byte read delay used instead of response delay!!!
/// </remarks>
/// <param name="sender"></param>
/// <param name="e"></param>
public virtual void PhysicalDataReceived(Object sender, SerialDataReceivedEventArgs e)
{
if (!_receiveToken.IsCancellationRequested)
{
//remove event delegate to avoid repeated execution during one record
_serialPort.DataReceived -= PhysicalDataReceived;
//put the actual time stamp to this record being able to assign it correctly
//even if the decoding is delayed. This time stamp will be used to do the first
//synchronization at start and stop of the measurement. Therefore the serial buffer
//has to be flushed in advance to avoid wrong time stamp to "old" records
_receiveTimeStampPc = DateTimeOffset.UtcNow;
//start timeout for hanging read communication called inter byte delay
_serialPort.ReadTimeout = InterByteReadDelayMs;
// _serialPort.ReadTimeout = PortSettingsForTransmitProtocol.ResponseTimeoutMs;
//wake up the reading threat from JoinWaitSleep
_onSyncReceiveThread.Set();
}
}
/// <summary>
/// <see cref="SyncMarkRecord" />
/// </summary>
private SyncMarkRecord _syncMarkRecord;
/// <inheritdoc />
public void SynchronizeReceiveBuffer(SyncMarkRecord syncMarkRecord)
{
try
{
//not in test bench situation only for temp logging
if (syncMarkRecord == SyncMarkRecord.FlushBuffer)
{
FlushBuffer();
return;
}
//DecodeEveryPackage is ongoing and SkipDecoding is requested = do nothing
if (_syncMarkRecord == SyncMarkRecord.DecodeEveryPackage &&
syncMarkRecord == SyncMarkRecord.SkipDecoding)
{
return;
}
//deny intermediate record when a start or end record is requested
if (syncMarkRecord == SyncMarkRecord.DecodeIntermediate &&
(_syncMarkRecord == SyncMarkRecord.SyncEnd ||
_syncMarkRecord == SyncMarkRecord.SyncStart))
{
return;
}
//being able to detect the first incoming record after a sync is requested, the buffer is going to be flushed
//if the measurement will be started or stopped
if (syncMarkRecord == SyncMarkRecord.SyncEnd ||
syncMarkRecord == SyncMarkRecord.SyncStart ||
syncMarkRecord == SyncMarkRecord.DecodeIntermediate)
{
FlushBuffer();
}
_byteDataLogger.Info($"{Ident} Mark next incoming record as {syncMarkRecord} (was {_syncMarkRecord})");
_syncMarkRecord = syncMarkRecord;
}
catch (Exception ex)
{
_byteDataLogger.Error($"{Ident} {ex.Message}");
}
}
private void FlushBuffer()
{
//check if flushing is allowed
if (null != PortSettingsForTransmitProtocol.ReceiveBufferFlushThreshold)
{
//flush buffer above threshold to get an accurate actual record with next record coming in
if (_serialPort.IsOpen && _serialPort.BytesToRead > PortSettingsForTransmitProtocol.ReceiveBufferFlushThreshold)
{
_byteDataLogger.Warn($"{Ident} Flushed receive buffer({_serialPort.BytesToRead}Byte)");
_serialPort.DiscardInBuffer();
}
}
}
/// <summary>
/// Reading thread loop getting data from serial port
/// </summary>
/// <remarks date="2018-Feb-16" author="T.Wiedebusch">
/// - Initial
/// </remarks>
/// <remarks date="2018-Mar-08" author="T.Wiedebusch">
/// - Reading will be executed and repeated until buffer is empty or timeout
/// </remarks>
/// <remarks date="2018-Mar-09" author="T.Wiedebusch">
/// - Receive byte protocol more dynamically on position of length information in record
/// and additional length,
/// - decoding of data controlled by dataSyncMarker!= SyncMarkRecord.SkipDecoding to speed up recording
/// </remarks>
/// <remarks date="2018-Oct-23" author="T.Wiedebusch">
/// - Directly invoked onRawRecord Received event,
/// - Doubling of sync byte implemented
/// </remarks>
/// <remarks date="2018-Dec-14" author="T.Wiedebusch">
/// - Timeout moved from ReadingThreadLoop to <see cref="PhysicalDataReceived"/> to avoid
/// <see cref="TimeoutException"/> of serial port while waiting on first incoming
/// data and flush receive buffer at timeout to force task to enter JoinWaitSleep state.
/// </remarks>
/// <remarks date="2019-Apr-11" author="T.Wiedebusch">
/// - Hide data in logging for e.g. passwords
/// </remarks>
/// <remarks date="2019-Dec-03" author="T.Wiedebusch">
/// - Raw record recording for missing sync-byte issues.
/// </remarks>
/// <remarks date="2019-Dec-04" author="T.Wiedebusch">
/// - Try to recover raw record on missing SYNC byte by adding the SYNC upfront and sending
/// the record to the decoding thread which will detect if just the SYNC byte had been
/// missed, then the CRC will match and the record can be decoded.
/// </remarks>
/// <remarks date="2019-Dec-05" author="T.Wiedebusch">
/// - Improved recovering of data sets at byte records with preceding SYNC byte:
/// - used payload length == 0 to skip decoding, it makes no sense to decode something where
/// the payload is empty,
/// - wait a certain time to complete incoming data.
/// </remarks>
/// <remarks date="2019-Dec-12" author="T.Wiedebusch">
/// - Inter byte read delay used instead of response delay.
/// </remarks>
/// <remarks date="2019-Dec-14" author="T.Wiedebusch">
/// - Flush buffer if received length is 0.
/// </remarks>
/// <remarks date="2022-Jul-15" author="T.Wiedebusch">
/// - Flush buffer (DiscardInBuffer) removed as some bytes are missing from time to time.
/// The IrDA sniffer showed these on the communication line, but they are incompletely received.
/// Assuming the DiscardInBuffer may be delayed, so the incoming data will be scrapped.
/// </remarks>
private void ReadingThreadLoop()
{
//put the receive thread to JoinWaitSleep to avoid reading and logger output for timeout on
//RFID communication, because RFID will handle the physical receive by itself
//here the assignment of the _synReadingThreadEvent to the reading thread is being done
_onSyncReceiveThread.WaitOne();
try
{
while (!_receiveToken.IsCancellationRequested)
{
try
{
//remind data marker for this Thread execution time slice
var dataSyncMarkThisRun = _syncMarkRecord;
//read line of ASCII indicated by syncByte == null
if (null == PortSettingsForTransmitProtocol.ProtSyncByte)
{
//exit is timeout from serialPort or received line
var rxStringRecord = _serialPort.ReadLine();
if (!string.IsNullOrEmpty(rxStringRecord))
{
//decode optional at synchronized data SyncStart, SyncEnd or DecodeIntermediate
//todo remove after air problem
if (SyncMarkRecord.SkipDecoding != dataSyncMarkThisRun)
{
OnRawRecordReceived?.Invoke(this, new StringPortDataEventArgs(rxStringRecord,
_receiveTimeStampPc, dataSyncMarkThisRun));
}
if (RecordStreamingRawData)
{
AsciiDataLogger.Trace($"{rxStringRecord}");
}
}
}
//byte record with preceding SYNC byte
else
{
//normally decoding is required
dataSyncMarkThisRun = SyncMarkRecord.DecodeEveryPackage;
//this is the record for decoding
var rxByteRecord = new List<Byte>();
//this is the informational record for logging on undetected SYNC byte
var rxRawRecord = new List<Byte>();
//each byte protocol has to start with a syncByte, this has to be detected first
Byte rxByte;
do
{
rxByte = (Byte)_serialPort.ReadByte();
//record raw data stream for output on missing sync-byte to investigate this issue
rxRawRecord.Add(rxByte);
} while (_serialPort.BytesToRead > 0 && PortSettingsForTransmitProtocol.ProtSyncByte != rxByte);
// if syncByte has not been detected skip read loop and wait for next incoming record
if (PortSettingsForTransmitProtocol.ProtSyncByte == rxByte)
{
//save received SYNC byte
rxByteRecord.Add(rxByte);
//to assemble the length it has to be extracted first from the record at given index,
//the payload length index cannot be 0 because at this position is always the SYNC byte,
//the overall length includes the SYNC byte!
var length = PortSettingsForTransmitProtocol.ProtLengthIndex + 1;
//if the protLengthIndex is null the protAddLength equals the entire record length
if (null == PortSettingsForTransmitProtocol.ProtLengthIndex)
{
length = PortSettingsForTransmitProtocol.ProtAddLength;
}
//read until length index to extract the length from the record
//the length index cannot be at position 0, because this is always the syncByte
do
{
rxByte = (Byte)_serialPort.ReadByte();
//read the next byte if doubled sync byte detected and required by transmit protocol settings
if (PortSettingsForTransmitProtocol.DoubleSyncByte)
{
if (rxByte.Equals(PortSettingsForTransmitProtocol.ProtSyncByte) &&
rxByteRecord[rxByteRecord.Count - 1].Equals(PortSettingsForTransmitProtocol.ProtSyncByte))
{
//skips this byte and read the next one
rxByte = (Byte)_serialPort.ReadByte();
}
}
//add byte to receive result buffer
rxByteRecord.Add(rxByte);
//capture the length at given index and readjust the record length
if (null != PortSettingsForTransmitProtocol.ProtLengthIndex
&& rxByteRecord.Count - 1 == PortSettingsForTransmitProtocol.ProtLengthIndex)
{
//if the received length indicates empty payload, then nothing is to decode
if (rxByte == 0)
{
//exit this loop
dataSyncMarkThisRun = SyncMarkRecord.SkipDecoding;
FlushBuffer();
}
else
{
//build the new length to continue this receive loop
length = (UInt16)(PortSettingsForTransmitProtocol.ProtAddLength + rxByte);
}
}
//wait a certain time to let the data stream coming in
if (length - rxByteRecord.Count - 1 > _serialPort.BytesToRead)
{
Thread.Sleep(2);
}
} while (rxByteRecord.Count < length && dataSyncMarkThisRun != SyncMarkRecord.SkipDecoding);
//all data received or skip decoding marked, skip decoding will clear the response timeout
//these protocols have always to be decoded because the base is a request protocol
OnRawRecordReceived?.Invoke(this, new ListBytePortDataEventArgs(rxByteRecord,
_receiveTimeStampPc, dataSyncMarkThisRun));
}
else
{
//output actual byte and recorded raw data stream to investigate missed sync-byte
_byteDataLogger.Warn($"{Ident} Response SYNC Byte missing. Raw Byte Received: " +
$"{BitConverter.ToString(rxRawRecord.ToArray())}");
}
}
}
catch (ThreadAbortException)
{ throw; }
catch (TimeoutException)
{
//ATTENTION: This "_serialPort.DiscardInBuffer()" caused a lot of trouble as it flushes a few incoming
//bytes and therefore destroys the already started data stream. Here it had been left in to indicate
//this critical issue!
/*-------------------------------DO NOT ACTIVATE-----------------------------------------------------*/
//flush receive buffer at timeout to force task to enter JoinWaitSleep state in finally
//if (_serialPort.IsOpen)
//{
// _serialPort.DiscardInBuffer();
//}
/*---------------------------------------------------------------------------------------------------*/
_byteDataLogger.Trace($"{Ident} Read timeout({InterByteReadDelayMs}ms)");
//_byteDataLogger.Trace($"{Ident} Read timeout({PortSettingsForTransmitProtocol.ResponseTimeoutMs}ms)");
}
catch (Exception ex)
{
if (_receiveThread.ThreadState == ThreadState.Aborted
|| _receiveThread.ThreadState == ThreadState.AbortRequested)
{
_byteDataLogger.Warn(ex, $"{ Ident} ThreadState is Aborted or AbortRequested but an " +
"error occurred while reading records from serial port");
}
else
{
_byteDataLogger.Error(ex, $"{ Ident} Error while reading records from serial port");
}
}
finally
{
if (_serialPort.IsOpen && !_receiveToken.IsCancellationRequested)
{
//it makes no sense to put the thread to sleep if there is something to read
if (0 == _serialPort.BytesToRead)
{
//restore event delegate to activate handle for incoming records
_serialPort.DataReceived += PhysicalDataReceived;
//put this thread (receive thread) to JainWaitSleep
_onSyncReceiveThread.WaitOne();
}
}
}
}//while (!_tokenReadData.IsCancellationRequested)
}// over hole reading thread loop
catch (ThreadAbortException)
{ }
catch (Exception ex)
{
_byteDataLogger.Error($"{Ident} {ex.Message}");
}
finally
{
if (_serialPort.IsOpen)
{
_serialPort.Close();
if (_serialPort.IsOpen)
{
_byteDataLogger.Info($"{Ident} Port close delay!");
Thread.Sleep(50);
_serialPort.Close();
}
_serialPort.Dispose();
_byteDataLogger.Info($"{Ident} Port is closed");
}
}
}
/// <inheritdoc />
public Boolean IsOpen()
{
return _serialPort != null && _serialPort.IsOpen;
}
/// <summary>
/// Serial port specific write routine
/// </summary>
/// <param name="txBuffer"></param>
/// <remarks date="2019-Apr-11" author="T.Wiedebusch">
/// - Hide data in logging for e.g. passwords
/// </remarks>
protected virtual void SpecificPortWrite(Byte[] txBuffer)
{
PhysicalWrite(txBuffer);
}
/// <summary>
/// Physically sending to the serial port
/// </summary>
/// <remarks date="2017" author="R.Drabesch">
/// - Initial
/// </remarks>
/// <remarks date="2018-Oct-23" author="T.Wiedebusch">
/// - Doubling of sync byte in protocol behind sync byte itself implemented
/// </remarks>
/// <remarks date="2022-Feb-25" author="T.Wiedebusch, R.Drabesch">
/// - Flush buffer as MOXA sometimes takes two messages and combines these to one!
/// As the Genesis needs a separated wake-up message with a following delay before the
/// real payload message, this causes a lot of trouble.
/// </remarks>
protected void PhysicalWrite(Byte[] txBuffer)
{
try
{
//don't double the sync byte itself
var txByteList = new List<Byte> { txBuffer[0] };
for (var byteCtr = 1; byteCtr < txBuffer.Length; byteCtr++)
{
txByteList.Add(txBuffer[byteCtr]);
//write the doubled sync byte again if required by transmit protocol settings
if (PortSettingsForTransmitProtocol.DoubleSyncByte)
{
if (txBuffer[byteCtr].Equals(PortSettingsForTransmitProtocol.ProtSyncByte))
{
txByteList.Add(txBuffer[byteCtr]);
}
}
}
_serialPort.Write(txByteList.ToArray(), 0, txByteList.Count);
// flush the buffer for MOXA, to avoid two subsequent communications assembled to one communication!
_serialPort.BaseStream.Flush();
OnRawRecordSendOut?.Invoke(this, new ListBytePortDataEventArgs(txByteList, DateTimeOffset.UtcNow));
}
catch (Exception ex)
{
_byteDataLogger.Error($"{Ident} {ex.Message}");
}
}
}
}
@@ -857,11 +857,20 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// <remarks date="2025-Apr-07" author="Thomas Wiedebusch">
/// - CancellationToken.
/// </remarks>
/// <remarks date="2025-Mai-07" author="Thomas Wiedebusch">
/// - Temporary excluded un-comparable registers from write as this make no sense to write them blind being
/// unable to read the correct value back.
/// </remarks>
private StatusReturn WriteRegisterParameterSet(List<RecoveryRegisterItem> recoveryRegistersDb, Int32 recRegistersCount,
MeterRegisters meterRegisters, CancellationToken cancellationToken)
{
foreach (var recReg in recoveryRegistersDb)
{
//TODO THW Check
// Temporary excluded un-comparable registers from write as this make no sense to write them blind being
// unable to read the correct value back.
if (_excludedFromCompareParameters.Any( regName => recReg.RegisterIdent.Equals(regName)))
continue;
_actualRegisterCtr++;
var overallProcessCtrPercent = 100.0 * _actualRegisterCtr / recRegistersCount;
@@ -146,10 +146,9 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// </summary>
private static readonly List<RecoveryRegisterItem> _finalizeProgrammingAll = new List<RecoveryRegisterItem>
{
// Writing 1 will force a log flush
new RecoveryRegisterItem("LOGGER_TriggerLogFlush", new Byte[] { 0x01 }),
// set counter to 0 as this is a value how often the radio detected a reset
new RecoveryRegisterItem("PERIODICLOG_ResetCounter", new Byte[] { 0x00 }),
// trigger idle 0 releases the display to normal operation
// Trigger idle 0 releases the display to normal operation
new RecoveryRegisterItem("GENESISFLOW_TriggerIdle", new Byte[] { 0x00 })
};
@@ -159,12 +158,16 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// </summary>
private static readonly List<RecoveryRegisterItem> _finalizeProgrammingEmea = new List<RecoveryRegisterItem>
{
// Set counter to 0 as this is a value how often the radio detected a reset
new RecoveryRegisterItem("SENSUSRADIO_ResetCounter", new Byte[] { 0x00 }),
// System state 0xFF will force a storage of all parameters and reset, followed by system state 0x02
// for customer mode, the reset needs only a few milliseconds
// Attention logout-delay-login required after this step!
new RecoveryRegisterItem("SENSUSRADIO_SystemState", new Byte[] { 0xFF }),
// seal the display to lock against changes
// Seal the display to lock against changes
new RecoveryRegisterItem("GENESISFLOW_SealDisplay", new Byte[] { 0x01 }),
// Set counter to 0 as this is a value how often the radio detected a reset
new RecoveryRegisterItem("PERIODICLOG_ResetCounter", new Byte[] { 0x00 }),
};
/// <summary>
@@ -172,8 +175,11 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// </summary>
private static readonly List<RecoveryRegisterItem> _finalizeProgrammingEol = new List<RecoveryRegisterItem>
{
// Writing 1 to this register clears the volume accumulator
new RecoveryRegisterItem("GENESISFLOW_ResetAccumulators", new Byte[] { 0x01 }),
// Writing 1 to this register erases the RMA area
new RecoveryRegisterItem("NFC_EraseRMA", new Byte[] { 0x01 }),
// Set counter to 0 as this is a value how often the customer app detected a reset
new RecoveryRegisterItem("CUSTOMER_RebootCount", new Byte[] { 0x00 })
};
@@ -182,11 +188,6 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// </summary>
private Int32 _actualRegisterCtr;
/// <summary>
/// Stop register access
/// </summary>
public Boolean StopRegisterAccess;
/// <summary>
/// Genesis meter object
/// </summary>
@@ -573,6 +574,8 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
List<RecoveryRegisterItem> recoveryRegistersDb, out String errorMsg)
{
errorMsg = "";
if (string.IsNullOrEmpty(pcbId))
return StatusReturn.Failed;
try
{
var url = $"{ServiceUrls.GenesisFinalCheckServiceUrl()}GetProgrammingParameters?PcbID={pcbId}";
@@ -620,14 +623,18 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// </summary>
/// <param name="recoveryRegistersDb">list of registers to update from database without special sequence
/// </param>
/// <param name="cancellationToken"></param>
/// <returns>true if setup succeeded</returns>
/// <remarks date="2024-Jan-17" author="Thomas Wiedebusch">
/// - Initial.
/// </remarks>
public StatusReturn EolProgrammingRegisters(List<RecoveryRegisterItem> recoveryRegistersDb)
/// <remarks date="2025-Apr-07" author="Thomas Wiedebusch">
/// - CancellationToken.
/// </remarks>
public StatusReturn EolProgrammingRegisters(List<RecoveryRegisterItem> recoveryRegistersDb, CancellationToken cancellationToken)
{
// mark EOL as true to force accu reset
return WriteRegisters(recoveryRegistersDb, true);
return WriteRegisters(recoveryRegistersDb, cancellationToken, true);
}
/// <summary>
@@ -668,6 +675,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// </summary>
/// <param name="recoveryRegistersDb">list of registers to update from database without special sequence
/// </param>
/// <param name="cancellationToken"></param>
/// <param name="eolProgramming">EOL (end of line) programming with accu reset</param>
/// <returns>true if restoring succeeded</returns>
/// <remarks date="2023-Oct-09" author="Thomas Wiedebusch">
@@ -722,7 +730,11 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// <remarks date="2025-Feb-14" author="Thomas Wiedebusch">
/// - Exported write routines to <see cref="WriteRegisterParameterSet"/>.
/// </remarks>
public StatusReturn WriteRegisters(List<RecoveryRegisterItem> recoveryRegistersDb, Boolean eolProgramming = false)
/// <remarks date="2025-Apr-07" author="Thomas Wiedebusch">
/// - CancellationToken.
/// </remarks>
public StatusReturn WriteRegisters(List<RecoveryRegisterItem> recoveryRegistersDb, CancellationToken cancellationToken,
Boolean eolProgramming = false)
{
if (_currentGenesis == null ||
string.IsNullOrEmpty(_currentGenesis.PcbId) ||
@@ -740,7 +752,6 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
RecoveryRegisters = recoveryRegistersDb;
}
StopRegisterAccess = false;
_actualRegisterCtr = 0;
// Build string list for debug
@@ -787,7 +798,8 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
OnProcessUpdate?.Invoke(this, new ProcessExecEventArgs(Resources.StrRegisterRecoveryPreparation,
actualProcessMessage: Resources.StrRegisterRecoveryPreparation));
if (StatusReturn.Failed == WriteRegisterParameterSet(_prepareProgramming, recRegistersCount, meterRegisters))
if (StatusReturn.Failed == WriteRegisterParameterSet(_prepareProgramming, recRegistersCount, meterRegisters,
cancellationToken))
{
// the logout will force the radio app to activate the settings
_currentGenesis?.Logout();
@@ -798,7 +810,8 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
OnProcessUpdate?.Invoke(this, new ProcessExecEventArgs(Resources.StrRegisterRecoveryExec,
actualProcessMessage: Resources.StrRegisterRecoveryExec));
if (StatusReturn.Failed == WriteRegisterParameterSet(recoveryRegistersDb, recRegistersCount, meterRegisters))
if (StatusReturn.Failed == WriteRegisterParameterSet(recoveryRegistersDb, recRegistersCount, meterRegisters,
cancellationToken))
{
// the logout will force the radio app to activate the settings
_currentGenesis?.Logout();
@@ -809,7 +822,8 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
OnProcessUpdate?.Invoke(this, new ProcessExecEventArgs(Resources.StrRegisterRecoveryFinalization,
actualProcessMessage: Resources.StrRegisterRecoveryFinalization));
if (StatusReturn.Failed == WriteRegisterParameterSet(finalizeProgrammingAll, recRegistersCount, meterRegisters))
if (StatusReturn.Failed == WriteRegisterParameterSet(finalizeProgrammingAll, recRegistersCount, meterRegisters,
cancellationToken))
{
// the logout will force the radio app to activate the settings
_currentGenesis?.Logout();
@@ -835,12 +849,16 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// <param name="recoveryRegistersDb"></param>
/// <param name="recRegistersCount"></param>
/// <param name="meterRegisters"></param>
/// <param name="cancellationToken"></param>
/// <returns></returns>
/// <remarks date="2025-Feb-14" author="Thomas Wiedebusch">
/// - Initial imported from <see cref="WriteRegisters"/>.
/// </remarks>
/// <remarks date="2025-Apr-07" author="Thomas Wiedebusch">
/// - CancellationToken.
/// </remarks>
private StatusReturn WriteRegisterParameterSet(List<RecoveryRegisterItem> recoveryRegistersDb, Int32 recRegistersCount,
MeterRegisters meterRegisters)
MeterRegisters meterRegisters, CancellationToken cancellationToken)
{
foreach (var recReg in recoveryRegistersDb)
{
@@ -913,7 +931,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
overallProcessCtrPercent, actualProcessMsg));
}
if (StopRegisterAccess)
if (cancellationToken.IsCancellationRequested)
break;
}
@@ -926,6 +944,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// - The _restoreRegisters has to be filled with all registers being able to restore (RW),
/// - The _finalReadRegisters has to be filled.
/// </summary>
/// <param name="cancellationToken"></param>
/// <returns>true if equal</returns>
/// <remarks date="2023-Nov-20" author="Thomas Wiedebusch">
/// - Initial.
@@ -963,13 +982,15 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// <remarks date="2024-Mar-20" author="Thomas Wiedebusch">
/// - Hash password and encryption key with SHA256.
/// </remarks>
public Boolean CompareRegisters()
/// <remarks date="2025-Apr-07" author="Thomas Wiedebusch">
/// - CancellationToken.
/// </remarks>
public Boolean CompareRegisters(CancellationToken cancellationToken)
{
if (_pcbIdFinalRegisterRead != _pcbIdWriteRegisters ||
RecoveryRegisters == null)
return false;
StopRegisterAccess = false;
_actualRegisterCtr = 0;
var retVal = true;
@@ -1130,7 +1151,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
}
}
if (StopRegisterAccess)
if (cancellationToken.IsCancellationRequested)
break;
}
catch (Exception ex)
@@ -1145,6 +1166,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// Read the registers after the update for comparision. Build the post update registers here,
/// because an update may have changed the registers (new or removed registers).
/// </summary>
/// <param name="cancellationToken"></param>
/// <returns>true if registers could be read</returns>
/// <remarks date="2020-Dec-08" author="Thomas Wiedebusch">
/// - Initial.
@@ -1174,7 +1196,10 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// <remarks date="2024-Dec-12" author="Thomas Wiedebusch">
/// - Check readBack value for null.
/// </remarks>
public Boolean FinalReadRegisters()
/// <remarks date="2025-Apr-07" author="Thomas Wiedebusch">
/// - CancellationToken.
/// </remarks>
public Boolean FinalReadRegisters(CancellationToken cancellationToken)
{
if (_currentGenesis == null)
return false;
@@ -1197,7 +1222,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
_finalRegisterList.Sort();
// executes login read logout
retVal = ReadRegistersSet(ref _finalRegisters);
retVal = ReadRegistersSet(ref _finalRegisters, cancellationToken);
// backup read data to RecoveryRegisters
if (RecoveryRegisters != null && _finalRegisters != null)
@@ -1239,6 +1264,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// The defined registers are based on the "configuration.json" and the installed application with
/// a specific version.
/// </summary>
/// <param name="cancellationToken"></param>
/// <returns>true if registers could be read</returns>
/// <remarks date="2020-Dec-08" author="Thomas Wiedebusch">
/// - Initial.
@@ -1263,7 +1289,10 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// <remarks date="2024-Feb-19" author="Thomas Wiedebusch">
/// - Register list changed from RegisterDefinition to RecoveryRegisterItem list.
/// </remarks>
public Boolean InitialReadRegisters()
/// <remarks date="2025-Apr-07" author="Thomas Wiedebusch">
/// - CancellationToken.
/// </remarks>
public Boolean InitialReadRegisters(CancellationToken cancellationToken)
{
if (_currentGenesis == null)
return false;
@@ -1289,7 +1318,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
_initialRegisterList = _initialRegisters.Select(register => register.RegisterIdent).ToList();
_initialRegisterList.Sort();
return ReadRegistersSet(ref _initialRegisters);
return ReadRegistersSet(ref _initialRegisters, cancellationToken);
}
/// <summary>
@@ -1344,6 +1373,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// The defined registers are based on the "configuration.json" and the installed application with a specific
/// version.
/// </summary>
/// <param name="cancellationToken"></param>
/// <returns>true if registers could be read</returns>
/// <remarks date="2023-Oct-16" author="Thomas Wiedebusch">
/// - Initial.
@@ -1351,7 +1381,10 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// <remarks date="2024-Feb-19" author="Thomas Wiedebusch">
/// - Register list changed from RegisterDefinition to RecoveryRegisterItem list.
/// </remarks>
public Boolean ReadRegisters()
/// <remarks date="2025-Apr-07" author="Thomas Wiedebusch">
/// - CancellationToken.
/// </remarks>
public Boolean ReadRegisters(CancellationToken cancellationToken)
{
if (_currentGenesis == null)
return false;
@@ -1366,17 +1399,21 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
OnProcessUpdate?.Invoke(this, new ProcessExecEventArgs($@"{Resources.StrReadRegister}", 0,
Resources.StrReadRegistersBeforeUpdate));
return ReadRegistersSet(ref registers);
return ReadRegistersSet(ref registers, cancellationToken);
}
/// <summary>
/// Read predefined registers from RecoveryRegisters.
/// </summary>
/// <param name="cancellationToken"></param>
/// <returns>true if registers could be read</returns>
/// <remarks date="2024-Sep-25" author="Thomas Wiedebusch">
/// - Initial.
/// </remarks>
public Boolean ReadPresetRegisters()
/// <remarks date="2025-Apr-07" author="Thomas Wiedebusch">
/// - CancellationToken.
/// </remarks>
public Boolean ReadPresetRegisters(CancellationToken cancellationToken)
{
if (_currentGenesis == null || RecoveryRegisters == null || RecoveryRegisters.Count == 0)
return false;
@@ -1387,7 +1424,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
_pcbIdWriteRegisters = _currentGenesis.PcbId;
_pcbIdFinalRegisterRead = _currentGenesis.PcbId;
return ReadRegistersSet(ref RecoveryRegisters);
return ReadRegistersSet(ref RecoveryRegisters, cancellationToken);
}
/// <summary>
@@ -1399,6 +1436,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// Executes login, read cycle and logout.
/// </summary>
/// <param name="registers">registers to read</param>
/// <param name="cancellationToken"></param>
/// <returns>true if registers could be read</returns>
/// <remarks date="2020-Dec-17" author="Thomas Wiedebusch">
/// - Initial.
@@ -1428,11 +1466,13 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// <remarks date="2024-Feb-19" author="Thomas Wiedebusch">
/// - Register list changed from RegisterDefinition to RecoveryRegisterItem list.
/// </remarks>
private Boolean ReadRegistersSet(ref List<RecoveryRegisterItem> registers)
/// <remarks date="2025-Apr-07" author="Thomas Wiedebusch">
/// - CancellationToken.
/// </remarks>
private Boolean ReadRegistersSet(ref List<RecoveryRegisterItem> registers, CancellationToken cancellationToken)
{
if (_currentGenesis == null)
return false;
StopRegisterAccess = false;
_actualRegisterCtr = 0;
// read values from Genesis
@@ -1501,7 +1541,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
overallProcessCtrPercent, actualProcessMsg));
}
if (StopRegisterAccess)
if (cancellationToken.IsCancellationRequested)
break;
}
catch (Exception ex)
@@ -1 +1 @@
8cb55c312de586b683d72cf58c13e2801d10e14b767777d98338d3e1473a1213
7df2ad6be70922b931820861acc675522243ee78