MagFlux: - api 1.0.2.49
This commit is contained in:
@@ -56,12 +56,6 @@ namespace XYLEM
|
||||
/// <param name="baudRate">Like 9600 (default on RS485)</param>
|
||||
/// <param name="parity">Like Parity.Even (default on RS485)</param>
|
||||
/// <returns></returns>
|
||||
Boolean Connect(string comport, UInt16 id, UInt32 baudRate, Parity parity);
|
||||
|
||||
/// <summary>
|
||||
/// Close communication connection to Meter
|
||||
/// </summary>
|
||||
/// <returns>true on okay or false on error</returns>
|
||||
Boolean CloseConnection();
|
||||
Boolean Connect(string comport, UInt16 id, UInt32 baudRate, Parity parity);
|
||||
}
|
||||
}
|
||||
|
||||
@@ -1,11 +1,11 @@
|
||||
using System.IO.Ports;
|
||||
using System;
|
||||
using System.IO.Ports;
|
||||
using XYLEM.Device;
|
||||
|
||||
namespace XYLEM
|
||||
{
|
||||
public interface IMagFluxAPI
|
||||
{
|
||||
|
||||
/// <summary>
|
||||
/// Make communication connection to Meter
|
||||
///
|
||||
@@ -36,5 +36,12 @@ namespace XYLEM
|
||||
/// <returns>Return a MagFlux device or "null" if failing connect</returns>
|
||||
/// <exception cref="InvalidDataException"> if the configuration is not valid</exception>
|
||||
IMagFluxRequestProtocol Connect(string comport, ushort id, uint baudRate, Parity parity, string log_path = null, RUN_TYPE runAs = RUN_TYPE.Normal);
|
||||
|
||||
/// <summary>
|
||||
/// Close communication connection to all Meters and clean up for a fresh connection of all devices.
|
||||
/// Note to continue, all devices needs initialized to be reconnected with Connect(...)
|
||||
/// </summary>
|
||||
/// <returns>true on okay or false on error</returns>
|
||||
Boolean CloseConnections();
|
||||
}
|
||||
}
|
||||
@@ -16,6 +16,20 @@ namespace XYLEM
|
||||
/// <returns>true if yes</returns>
|
||||
Boolean IsConnected();
|
||||
|
||||
/// <summary>
|
||||
/// Close communication connection to Meter
|
||||
/// </summary>
|
||||
/// <returns>true on okay or false on error</returns>
|
||||
Boolean CloseConnection();
|
||||
|
||||
/// <summary>
|
||||
/// Try reconnect communication to a Meter that already had a communication connection
|
||||
/// Note: will reuse already used communication settings and CloseConnection() is not already closed before call.
|
||||
/// Used for reestablished communication to Meter when fail to respond during normal operation
|
||||
/// </summary>
|
||||
/// <returns>true on okay or false on error</returns>
|
||||
Boolean Reconnect();
|
||||
|
||||
/// <summary>
|
||||
/// Get current device Modbus ID / Device Address
|
||||
/// </summary>
|
||||
@@ -147,6 +161,22 @@ namespace XYLEM
|
||||
/// <returns>true on okay or false on error</returns>
|
||||
Boolean GetFlowRate_lps(out Single value_out);
|
||||
|
||||
|
||||
/// <summary>
|
||||
/// Average Electrode measurement used for Device calibration verification
|
||||
/// </summary>
|
||||
/// <param name="value_out"> Average Electrode [mV] </param>
|
||||
/// <returns>true on okay or false on error</returns>
|
||||
Boolean GetAverage_Electrode_mV(out Single value_out);
|
||||
|
||||
/// <summary>
|
||||
/// Standard deviation electrode measurement used for Device calibration verification
|
||||
/// Note: update will only happen after x seconds, depending on filter config in device
|
||||
/// </summary>
|
||||
/// <param name="value_out"> Average Electrode [mV] </param>
|
||||
/// <returns>true on okay or false on error</returns>
|
||||
Boolean GetStdDev_Electrode_mV(out Single value_out);
|
||||
|
||||
/// <summary>
|
||||
/// !!! Warning make sure to turn off simulation, when calibration off sensor is done !!!
|
||||
/// ----
|
||||
|
||||
Binary file not shown.
Binary file not shown.
@@ -37,6 +37,14 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
|
||||
{
|
||||
#region Variables and Properties
|
||||
|
||||
///// <summary>
|
||||
///// Reminder for ignore empty pipe detection
|
||||
///// </summary>
|
||||
//private Boolean _lastIgnoreEmptyPipeDetection;
|
||||
///// <summary>
|
||||
///// Reminder for simulated flow
|
||||
///// </summary>
|
||||
//private Boolean _lastSimulatedFlowActive;
|
||||
/// <summary>
|
||||
/// Reminder for status bits
|
||||
/// </summary>
|
||||
@@ -51,6 +59,20 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
|
||||
/// </summary>
|
||||
private Boolean _enableRawDataLogging;
|
||||
|
||||
/// <summary>
|
||||
/// Simulated flow activity
|
||||
/// </summary>
|
||||
public Boolean SimulatedFlowIsActive
|
||||
{
|
||||
get; set;
|
||||
}
|
||||
/// <summary>
|
||||
/// Empty pipe ignore
|
||||
/// </summary>
|
||||
public Boolean IgnoreEmptyPipeDetection
|
||||
{
|
||||
get; set;
|
||||
}
|
||||
/// <summary>
|
||||
/// to reduce the IrdA communication in test bench, preparation will be done once (when SkipPreparationForTestBench is true)
|
||||
/// </summary>
|
||||
@@ -123,6 +145,22 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
|
||||
get; private set;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Average of the electrode in milli Volts
|
||||
/// </summary>
|
||||
public Single AverageElectrode_mV
|
||||
{
|
||||
get; private set;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Standard deviation of the electrode in milli Volts
|
||||
/// </summary>
|
||||
public Single StandardDeviationElectrode_mV
|
||||
{
|
||||
get; private set;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Represents Empty Pipe Detection control bits
|
||||
/// Bit0="EPD disabled", 1="Enabled w. Flags only", 2="EPD enabled full"
|
||||
@@ -300,6 +338,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
|
||||
private readonly CancellationTokenSource _keepSessionToken = new CancellationTokenSource();
|
||||
|
||||
private ILogger _logger;
|
||||
//private ILogger _loggerRawData;
|
||||
|
||||
#endregion
|
||||
|
||||
@@ -859,9 +898,21 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
|
||||
{
|
||||
EpdControlBits = epd_cntl_bits;
|
||||
}
|
||||
|
||||
RequestProtocol?.GetCalibrationPoints(out _);
|
||||
StreamingProtocol?.SetDecodingMask(SensorSerialNo, uniqueId);
|
||||
if (RequestProtocol.GetStdDev_Electrode_mV(out var u_mV))
|
||||
{
|
||||
StandardDeviationElectrode_mV = u_mV;
|
||||
}
|
||||
if (RequestProtocol.GetAverage_Electrode_mV(out u_mV))
|
||||
{
|
||||
AverageElectrode_mV = u_mV;
|
||||
}
|
||||
|
||||
SimulatedFlowIsActive = RequestProtocol.IsSimulatedFlowActive();
|
||||
IgnoreEmptyPipeDetection = RequestProtocol.GetIgnoreFailOnEmptyPipeOnHealthy();
|
||||
|
||||
RequestProtocol.GetCalibrationPoints(out _);
|
||||
StreamingProtocol.SetDecodingMask(SensorSerialNo, uniqueId);
|
||||
|
||||
return IsLoggedOn;
|
||||
}
|
||||
|
||||
@@ -886,7 +937,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
|
||||
}
|
||||
else
|
||||
{
|
||||
WriteLog("Wait on measurement start");
|
||||
WriteLog($"Slot:{Slot} - Wait on measurement start");
|
||||
}
|
||||
ProcessStatus = ProcessState.WaitForMeasurement;
|
||||
}
|
||||
@@ -937,7 +988,6 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
|
||||
}
|
||||
|
||||
/// <inheritdoc />
|
||||
///
|
||||
public List<MeasurementResults> GetAllMeasurementResults(Double? refVolume, Double? refTimeS, Boolean intermediateMeasurement = false,
|
||||
Int32? channel = null, MeasurementDirection dir = MeasurementDirection.TakeBoth)
|
||||
{
|
||||
@@ -1052,7 +1102,6 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
|
||||
/// </summary>
|
||||
public void WriteCalibration(List<Calibration> calibrationsCmPerH)
|
||||
{
|
||||
_logger.Info($"Slot:{Slot} - Write calibration values to MagFlux");
|
||||
RequestProtocol?.SetCalibrationPoints(calibrationsCmPerH);
|
||||
RequestProtocol?.CloseConnection();
|
||||
}
|
||||
@@ -1062,40 +1111,58 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
|
||||
public void ReadCalibration(out List<Calibration> calibrationsCmPerH)
|
||||
{
|
||||
calibrationsCmPerH = null;
|
||||
_logger.Info($"Slot:{Slot} - Read calibration values from MagFlux");
|
||||
RequestProtocol?.GetCalibrationPoints(out calibrationsCmPerH);
|
||||
RequestProtocol?.CloseConnection();
|
||||
}
|
||||
|
||||
///// <summary>
|
||||
///// Turn on/off fixed test flow output from MagFlux
|
||||
///// Used for getting a fixed simulated flow from MagFlux
|
||||
///// </summary>
|
||||
///// <param name="testFlowOn"></param>
|
||||
///// <returns>true on okay or false on error</returns>
|
||||
//public Boolean SetSimulatedFlowActive(Boolean testFlowOn)
|
||||
//{
|
||||
// _logger.Info($"Slot:{Slot} - Set test flow");
|
||||
// return RequestProtocol.SetSimulatedFlowActive(on);
|
||||
//}
|
||||
/// <summary>
|
||||
/// Average Electrode measurement used for Device calibration verification
|
||||
/// </summary>
|
||||
/// <param name="u_mV"> Average Electrode [mV] </param>
|
||||
/// <returns>true on okay or false on error</returns>
|
||||
public Boolean GetAverage_Electrode_mV(out Single u_mV)
|
||||
{
|
||||
u_mV = 0;
|
||||
var retVal = RequestProtocol.GetAverage_Electrode_mV(out u_mV);
|
||||
AverageElectrode_mV = u_mV;
|
||||
return retVal;
|
||||
}
|
||||
|
||||
///// <summary>
|
||||
///// Is the fixed test flow active
|
||||
///// Used for getting a fixed simulated flow from MagFlux
|
||||
///// </summary>
|
||||
///// <returns>true if ON</returns>
|
||||
//public Boolean IsSimulatedFlowActive()
|
||||
//{
|
||||
// _logger.Info($"Slot:{Slot} - Get test flow setting");
|
||||
// return RequestProtocol.IsSimulatedFlowActive();
|
||||
//};
|
||||
/// <summary>
|
||||
/// Standard deviation electrode measurement used for Device calibration verification
|
||||
/// Note: update will only happen after x seconds, depending on filter config in device
|
||||
/// </summary>
|
||||
/// <param name="u_mV"> Average Electrode [mV] </param>
|
||||
/// <returns>true on okay or false on error</returns>
|
||||
public Boolean GetStdDev_Electrode_mV(out Single u_mV)
|
||||
{
|
||||
u_mV = 0;
|
||||
//_logger.Info($"Slot:{Slot} - Read standard deviation of electrode voltage");
|
||||
var retVal = RequestProtocol.GetStdDev_Electrode_mV(out u_mV);
|
||||
StandardDeviationElectrode_mV = u_mV;
|
||||
return retVal;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Ignore Empty pipe flag on Healthy, because it is not yet working correct
|
||||
/// Note: Not 100% secure all test is working during empty pipe, metrology board firmware may not allow running during detection of empty pipe
|
||||
/// </summary>
|
||||
/// <param name="ignoreEmptyPipeStatus"></param>
|
||||
/// <returns>true on okay or false on error</returns>
|
||||
public Boolean SetIgnoreFailOnEmptyPipeOnHealthy(Boolean ignoreEmptyPipeStatus)
|
||||
{
|
||||
//_logger.Info($"Slot:{Slot} - Set ignore empty pipe status");
|
||||
var retVal = RequestProtocol.SetIgnoreFailOnEmptyPipeOnHealthy(ignoreEmptyPipeStatus);
|
||||
if (retVal)
|
||||
IgnoreEmptyPipeDetection = ignoreEmptyPipeStatus;
|
||||
return retVal;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Set PCB settings and PCB calibrations to default.
|
||||
/// </summary>
|
||||
public Boolean SetPCBToDemoDefaults()
|
||||
{
|
||||
_logger.Info($"Slot:{Slot} - Set PCB settings and PCB calibrations to default");
|
||||
if (RequestProtocol == null)
|
||||
return false;
|
||||
var retVal = RequestProtocol.SetPCBToDemoDefaults();
|
||||
@@ -1108,7 +1175,6 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
|
||||
/// </summary>
|
||||
public Boolean SetMeterSizeMm(UInt16 meterSize_mm)
|
||||
{
|
||||
_logger.Info($"Slot:{Slot} - Set meter size in mm");
|
||||
if (RequestProtocol == null)
|
||||
return false;
|
||||
var retVal = RequestProtocol.SetMeterSizeMm(meterSize_mm);
|
||||
@@ -1121,7 +1187,6 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
|
||||
/// </summary>
|
||||
public Boolean SetSensorSerialNo(UInt32 sensorSerialNo)
|
||||
{
|
||||
_logger.Info($"Slot:{Slot} - Set sensor serial no.");
|
||||
if (RequestProtocol == null)
|
||||
return false;
|
||||
var retVal = RequestProtocol.SetSensorSerialNo(sensorSerialNo);
|
||||
@@ -1132,7 +1197,6 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
|
||||
/// <inheritdoc />
|
||||
public void InitCalibration()
|
||||
{
|
||||
_logger.Info($"Slot:{Slot} - Init calibration and set calibration values of all channels to default");
|
||||
if (RequestProtocol == null)
|
||||
return;
|
||||
if (RequestProtocol.PrepareDeviceForCalibration())
|
||||
@@ -1194,6 +1258,12 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
|
||||
public void WriteLog(String text)
|
||||
{
|
||||
_logger.Info($"Slot:{Slot} - {text}");
|
||||
}
|
||||
|
||||
/// <inheritdoc />
|
||||
public void LogRawData(Boolean on)
|
||||
{
|
||||
_enableRawDataLogging = on;
|
||||
//if (_enableRawDataLogging)
|
||||
//{
|
||||
// if (_loggerRawData == null)
|
||||
@@ -1202,14 +1272,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
|
||||
// StreamingPort.GetPortName(), "", "LedRawData", "TargetLedRawDataBase", "LedRawDataBase");
|
||||
|
||||
// }
|
||||
// _loggerRawData.Info($"{text}");
|
||||
//}
|
||||
}
|
||||
|
||||
/// <inheritdoc />
|
||||
public void LogRawData(Boolean on)
|
||||
{
|
||||
_enableRawDataLogging = on;
|
||||
if (StreamingPort is LedSerialPort port)
|
||||
{
|
||||
port.RecordStreamingRawData = _enableRawDataLogging;
|
||||
|
||||
@@ -137,21 +137,21 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
|
||||
return retVal;
|
||||
}
|
||||
|
||||
///// <summary>
|
||||
///// Wrapper to get the simulated flow setting
|
||||
///// </summary>
|
||||
///// <returns></returns>
|
||||
///// <remarks date="2024-Aug-23" author="T.Wiedebusch">
|
||||
///// - Initial
|
||||
///// </remarks>
|
||||
//public Boolean GetSimulatedFlowOn()
|
||||
//{
|
||||
// if (_magFluxRequestProtocol == null) return false;
|
||||
// var retVal = _magFluxRequestProtocol.IsSimulatedFlowActive();
|
||||
// _logger.Debug(retVal ? $"{_ident} Simulated flow active read back returns: true" :
|
||||
// $"{_ident} Read back simulated flow status failed!");
|
||||
// return retVal;
|
||||
//}
|
||||
/// <summary>
|
||||
/// Wrapper to get the simulated flow setting
|
||||
/// </summary>
|
||||
/// <returns></returns>
|
||||
/// <remarks date="2024-Aug-23" author="T.Wiedebusch">
|
||||
/// - Initial
|
||||
/// </remarks>
|
||||
public Boolean IsSimulatedFlowActive()
|
||||
{
|
||||
if (_magFluxRequestProtocol == null)
|
||||
return false;
|
||||
var retVal = _magFluxRequestProtocol.IsSimulatedFlowActive();
|
||||
_logger.Debug($"{_ident} Simulated flow active read back returns: {retVal}");
|
||||
return retVal;
|
||||
}
|
||||
|
||||
///// <summary>
|
||||
///// Wrapper to set the simulated flow setting
|
||||
@@ -163,45 +163,48 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
|
||||
///// </remarks>
|
||||
//public Boolean SetSimulatedFlowActive(Boolean on)
|
||||
//{
|
||||
// if (_magFluxRequestProtocol == null) return false;
|
||||
// if (_magFluxRequestProtocol == null)
|
||||
// return false;
|
||||
// var retVal = _magFluxRequestProtocol.SetSimulatedFlowActive(on);
|
||||
// _logger.Debug(retVal ? $"{_ident} Simulated flow active set to: {on}" :
|
||||
// _logger.Debug(retVal ? $"{_ident} Simulated flow active set to: {on}" :
|
||||
// $"{_ident} Simulated flow active setup failed!");
|
||||
// return retVal;
|
||||
//}
|
||||
|
||||
///// <summary>
|
||||
///// Wrapper to get the ignore empty pipe mode status
|
||||
///// </summary>
|
||||
///// <returns></returns>
|
||||
///// <remarks date="2024-Aug-23" author="T.Wiedebusch">
|
||||
///// - Initial
|
||||
///// </remarks>
|
||||
//public Boolean GetIgnoreEmptyPipeStatus()
|
||||
//{
|
||||
// if (_magFluxRequestProtocol == null) return false;
|
||||
// var retVal = _magFluxRequestProtocol.IgnoreFailOnEmptyPipeOnHealthy();
|
||||
// _logger.Debug(retVal ? $"{_ident} Ignore empty pipe status read back returns: {retVal}" :
|
||||
// $"{_ident} Read back empty pipe status failed!");
|
||||
// return retVal;
|
||||
//}
|
||||
/// <summary>
|
||||
/// Wrapper to get the ignore empty pipe mode status
|
||||
/// </summary>
|
||||
/// <returns></returns>
|
||||
/// <remarks date="2024-Aug-23" author="T.Wiedebusch">
|
||||
/// - Initial
|
||||
/// </remarks>
|
||||
public Boolean GetIgnoreFailOnEmptyPipeOnHealthy()
|
||||
{
|
||||
if (_magFluxRequestProtocol == null)
|
||||
return false;
|
||||
var retVal = _magFluxRequestProtocol.GetIgnoreFailOnEmptyPipeOnHealthy();
|
||||
_logger.Debug($"{_ident} Ignore empty pipe status read back returns: {retVal}");
|
||||
return retVal;
|
||||
}
|
||||
|
||||
///// <summary>
|
||||
///// Wrapper to set the ignore empty pipe mode
|
||||
///// </summary>
|
||||
///// <param name="on">true to ignore state</param>
|
||||
///// <returns></returns>
|
||||
///// <remarks date="2024-Aug-23" author="T.Wiedebusch">
|
||||
///// - Initial
|
||||
///// </remarks>
|
||||
//public Boolean SetIgnoreEmptyPipeStatus(Boolean on)
|
||||
//{
|
||||
// if (_magFluxRequestProtocol == null) return false;
|
||||
// var retVal = _magFluxRequestProtocol.IgnoreFailOnEmptyPipeOnHealthy(on);
|
||||
// _logger.Debug(retVal ? $"{_ident} Ignore empty pipe status adjusted to: {on}" :
|
||||
// $"{_ident} Setup empty pipe status request failed!");
|
||||
// return retVal;
|
||||
//}
|
||||
/// <summary>
|
||||
/// Wrapper to set the ignore empty pipe mode
|
||||
/// </summary>
|
||||
/// <param name="on">true to ignore state</param>
|
||||
/// <returns></returns>
|
||||
/// <remarks date="2024-Aug-23" author="T.Wiedebusch">
|
||||
/// - Initial
|
||||
/// </remarks>
|
||||
public Boolean SetIgnoreFailOnEmptyPipeOnHealthy(Boolean on)
|
||||
{
|
||||
if (_magFluxRequestProtocol == null)
|
||||
return false;
|
||||
_magFluxRequestProtocol.SetIgnoreFailOnEmptyPipeOnHealthy(on);
|
||||
var retVal = _magFluxRequestProtocol.GetIgnoreFailOnEmptyPipeOnHealthy();
|
||||
_logger.Debug(retVal == on ? $"{_ident} Ignore empty pipe status adjusted to: {on}" :
|
||||
$"{_ident} Ignore empty pipe status setup failed!");
|
||||
return retVal == on;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Wrapper to get the empty pipe bits
|
||||
@@ -221,6 +224,41 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
|
||||
return retVal;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Wrapper to get the standard deviation value of the electrode in milli Volts
|
||||
/// </summary>
|
||||
/// <param name="u_mV"></param>
|
||||
/// <returns></returns>
|
||||
/// <remarks date="2024-Sep-19" author="T.Wiedebusch">
|
||||
/// - Initial
|
||||
/// </remarks>
|
||||
public Boolean GetStdDev_Electrode_mV(out Single u_mV)
|
||||
{
|
||||
u_mV = 0;
|
||||
if (_magFluxRequestProtocol == null) return false;
|
||||
var retVal = _magFluxRequestProtocol.GetStdDev_Electrode_mV(out u_mV);
|
||||
_logger.Debug(retVal ? $"{_ident} Standard deviation of electrode: {u_mV:F6} mV" :
|
||||
$"{_ident} Standard deviation of electrode request failed!");
|
||||
return retVal;
|
||||
}
|
||||
/// <summary>
|
||||
/// Wrapper to get the standard deviation value of the electrode in milli Volts
|
||||
/// </summary>
|
||||
/// <param name="u_mV"></param>
|
||||
/// <returns></returns>
|
||||
/// <remarks date="2024-Sep-19" author="T.Wiedebusch">
|
||||
/// - Initial
|
||||
/// </remarks>
|
||||
public Boolean GetAverage_Electrode_mV(out Single u_mV)
|
||||
{
|
||||
u_mV = 0;
|
||||
if (_magFluxRequestProtocol == null) return false;
|
||||
var retVal = _magFluxRequestProtocol.GetAverage_Electrode_mV(out u_mV);
|
||||
_logger.Debug(retVal ? $"{_ident} Average of electrode: {u_mV:F6} mV" :
|
||||
$"{_ident} Average of electrode request failed!");
|
||||
return retVal;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Wrapper to get the board calibration value
|
||||
/// </summary>
|
||||
|
||||
+1
-1
@@ -1 +1 @@
|
||||
89102b0142e574de38a9f47d370f3334e5e6c268
|
||||
8fbe991b217e7692af4817ad205b768685aa5a72
|
||||
|
||||
Reference in New Issue