CUST: - Moved recovery sequencing from FwUpdateBuilder to FwUpdateSw to inform in report about ongoing sequence (preparation, execution and finalization of recovery)

This commit is contained in:
Thomas Wiedebusch
2023-10-25 06:25:45 +02:00
parent d7bcdc22a5
commit 97a6ed93c6
11 changed files with 201 additions and 55 deletions
@@ -56,30 +56,42 @@ namespace Xylem.Common.Hardware.Interfaces.Protocols.ProtocolCore
/// <remarks date="2018-Feb-14" author="T.Wiedebusch"> /// <remarks date="2018-Feb-14" author="T.Wiedebusch">
/// - Initial /// - Initial
/// </remarks> /// </remarks>
public virtual void Dispose() /// <remarks date="2023-Oct-25" author="T.Wiedebusch">
/// - try catch block.
/// </remarks>
public void Dispose()
{ {
//Cancel receive tokens try
_decodingToken.Cancel();
//Run thread again to notice CancellationToken has changed
_onSyncDecodingThread.Set();
//this timeout counter is being used for dispose only
var timeoutCounter = 100;
while (_decodingThread.ThreadState != ThreadState.Stopped && timeoutCounter > 0)
{ {
Thread.Sleep(1); //Cancel receive tokens
timeoutCounter -= 1; _decodingToken.Cancel();
}
if (_decodingThread.ThreadState != ThreadState.Stopped) //Run thread again to notice CancellationToken has changed
{ _onSyncDecodingThread.Set();
//if thread still running, he stuck so try to abort
// try to avoid abort (takes age to run and is not safe) //this timeout counter is being used for dispose only
_decodingThread.Abort(); var timeoutCounter = 100;
while (_decodingThread.ThreadState != ThreadState.Stopped && timeoutCounter > 0)
{
Thread.Sleep(1);
timeoutCounter -= 1;
//Run thread again to notice CancellationToken has changed
_onSyncDecodingThread.Set();
}
if (_decodingThread.ThreadState != ThreadState.Stopped)
{
//if thread still running, he stuck so try to abort
// try to avoid abort (takes age to run and is not safe)
_decodingThread.Abort();
}
} }
} catch (Exception ex)
{
throw new ApplicationException(ex.Message);
}
}
/// <summary> /// <summary>
/// Fill FIFO with received data /// Fill FIFO with received data
@@ -61,7 +61,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Properties {
} }
/// <summary> /// <summary>
/// Looks up a localized string similar to Compare register. /// Looks up a localized string similar to Compare registers.....
/// </summary> /// </summary>
internal static string StrCompareRegister { internal static string StrCompareRegister {
get { get {
@@ -141,6 +141,33 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Properties {
} }
} }
/// <summary>
/// Looks up a localized string similar to Recovery configuration.....
/// </summary>
internal static string StrRegisterRecoveryExec {
get {
return ResourceManager.GetString("StrRegisterRecoveryExec", resourceCulture);
}
}
/// <summary>
/// Looks up a localized string similar to Finalize configuration recovery sequence.....
/// </summary>
internal static string StrRegisterRecoveryFinalization {
get {
return ResourceManager.GetString("StrRegisterRecoveryFinalization", resourceCulture);
}
}
/// <summary>
/// Looks up a localized string similar to Prepare configuration recovery sequence.....
/// </summary>
internal static string StrRegisterRecoveryPreparation {
get {
return ResourceManager.GetString("StrRegisterRecoveryPreparation", resourceCulture);
}
}
/// <summary> /// <summary>
/// Looks up a localized string similar to Cordonel not detected!. /// Looks up a localized string similar to Cordonel not detected!.
/// </summary> /// </summary>
@@ -139,7 +139,7 @@
<value>Suche Anschluß....</value> <value>Suche Anschluß....</value>
</data> </data>
<data name="StrCompareRegister" xml:space="preserve"> <data name="StrCompareRegister" xml:space="preserve">
<value>Vergleiche Register</value> <value>Vergleiche Register...</value>
</data> </data>
<data name="StrReadRegister" xml:space="preserve"> <data name="StrReadRegister" xml:space="preserve">
<value>Lese Register</value> <value>Lese Register</value>
@@ -153,4 +153,13 @@
<data name="StrReadRegistersAfterUpdate" xml:space="preserve"> <data name="StrReadRegistersAfterUpdate" xml:space="preserve">
<value>Lese Register nach dem Firmware Update</value> <value>Lese Register nach dem Firmware Update</value>
</data> </data>
<data name="StrRegisterRecoveryExec" xml:space="preserve">
<value>Ausführung Konfigurationswiederherstellungssequenz....</value>
</data>
<data name="StrRegisterRecoveryFinalization" xml:space="preserve">
<value>Abschließen Konfigurationswiederherstellungssequenz....</value>
</data>
<data name="StrRegisterRecoveryPreparation" xml:space="preserve">
<value>Vorbereitung Konfigurationswiederherstellungssequenz....</value>
</data>
</root> </root>
@@ -145,7 +145,7 @@
<value>Reading registers before update</value> <value>Reading registers before update</value>
</data> </data>
<data name="StrCompareRegister" xml:space="preserve"> <data name="StrCompareRegister" xml:space="preserve">
<value>Compare register</value> <value>Compare registers....</value>
</data> </data>
<data name="StrReadRegister" xml:space="preserve"> <data name="StrReadRegister" xml:space="preserve">
<value>Read register</value> <value>Read register</value>
@@ -153,4 +153,13 @@
<data name="StrWriteRegister" xml:space="preserve"> <data name="StrWriteRegister" xml:space="preserve">
<value>Write register</value> <value>Write register</value>
</data> </data>
<data name="StrRegisterRecoveryExec" xml:space="preserve">
<value>Recovery configuration....</value>
</data>
<data name="StrRegisterRecoveryFinalization" xml:space="preserve">
<value>Finalize configuration recovery sequence....</value>
</data>
<data name="StrRegisterRecoveryPreparation" xml:space="preserve">
<value>Prepare configuration recovery sequence....</value>
</data>
</root> </root>
@@ -195,6 +195,9 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// - Return true if already recovered, /// - Return true if already recovered,
/// - replace _restoreRegisters with new value. /// - replace _restoreRegisters with new value.
/// </remarks> /// </remarks>
/// <remarks date="2023-10-25" author="Thomas Wiedebusch">
/// - Added preparation and finalization of register recovery giving the ability to log this in the report.
/// </remarks>
public Boolean RecoverRegisters(List<RecoveryRegisterItem> recoveryRegisters) public Boolean RecoverRegisters(List<RecoveryRegisterItem> recoveryRegisters)
{ {
if (_currentGenesis == null || if (_currentGenesis == null ||
@@ -220,21 +223,76 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
// get the pre-defined dictionary // get the pre-defined dictionary
var meterRegisters = _currentGenesis.GetConfigRegistersDefinitions(); var meterRegisters = _currentGenesis.GetConfigRegistersDefinitions();
var recRegistersCount = recoveryRegisters.Count > 0 ? recoveryRegisters.Count : 1;
// prepare list for finalization depending on SENSUSRADIO installation
var finalizeProgrammingAll = new List<ProgrammingParameters>();
finalizeProgrammingAll.AddRange(FinalizeProgramming);
if (recoveryRegisters.Any(x => x.RegisterIdent.Contains("SENSUSRADIO")))
{
finalizeProgrammingAll.AddRange(FinalizeProgrammingRadioOnly);
}
// set the process counter
var recRegistersCount = recoveryRegisters.Count > 0 ? recoveryRegisters.Count : 1;
recRegistersCount += PrepareProgramming.Count;
recRegistersCount += finalizeProgrammingAll.Count;
// prepare recovery
OnProcessUpdate?.Invoke(this, new ProcessExecEventArgs(Resources.StrRegisterRecoveryPreparation,
actualProcessMessage: Resources.StrRegisterRecoveryPreparation));
foreach (var prepRecReg in PrepareProgramming)
{
ActualRegisterCtr++;
var overallProcessCtrPercent = 100.0 * ActualRegisterCtr / recRegistersCount;
try
{
_currentGenesis.WriteRegister(prepRecReg.RegisterName, prepRecReg.RegisterValue);
// if this call does not throw an exception, the register is present
var regDef = meterRegisters.GetRegisterDefinitionByName(prepRecReg.RegisterName);
var strRawAndConvertedValue = "";
try
{
strRawAndConvertedValue = RegisterConverter.GetRegisterContentText(regDef, prepRecReg.RegisterValue);
}
catch (Exception)
{
// nothing to do
}
finally
{
var actualProcessMsg = $"{Resources.StrWriteRegister}: {strRawAndConvertedValue} ";
OnProcessUpdate?.Invoke(this, new ProcessExecEventArgs($@"{Resources.StrWriteRegister}" +
$@" {ActualRegisterCtr} / {recRegistersCount}",
overallProcessCtrPercent, actualProcessMsg));
}
if (StopRegisterAccess)
break;
}
catch (Exception)
{
// nothing to do
}
}// prepare recovery
// register recovery
OnProcessUpdate?.Invoke(this, new ProcessExecEventArgs(Resources.StrRegisterRecoveryExec,
actualProcessMessage: Resources.StrRegisterRecoveryExec));
foreach (var recReg in recoveryRegisters) foreach (var recReg in recoveryRegisters)
{ {
ActualRegisterCtr++; ActualRegisterCtr++;
var overallProcessCtrPercent = 100.0 * ActualRegisterCtr / recRegistersCount; var overallProcessCtrPercent = 100.0 * ActualRegisterCtr / recRegistersCount;
try try
{ {
_currentGenesis.WriteRegister(recReg.RegisterIdent, recReg.WriteValue); _currentGenesis.WriteRegister(recReg.RegisterIdent, recReg.WriteValue);
// if this call doe not throw an exception, the register is present // if this call does not throw an exception, the register is present
var regDef = meterRegisters.GetRegisterDefinitionByName(recReg.RegisterIdent); var regDef = meterRegisters.GetRegisterDefinitionByName(recReg.RegisterIdent);
// replace value in _restoreRegister with the required recovery value // replace value in _restoreRegister with the required recovery value
_restoreRegisters?.Set(regDef, recReg.WriteValue); _restoreRegisters?.Set(regDef, recReg.WriteValue);
@@ -251,6 +309,48 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
{ {
var actualProcessMsg = $"{Resources.StrWriteRegister}: {strRawAndConvertedValue} "; var actualProcessMsg = $"{Resources.StrWriteRegister}: {strRawAndConvertedValue} ";
OnProcessUpdate?.Invoke(this, new ProcessExecEventArgs($@"{Resources.StrWriteRegister}" +
$@" {ActualRegisterCtr} / {recRegistersCount}",
overallProcessCtrPercent, actualProcessMsg));
}
if (StopRegisterAccess)
break;
}
catch (Exception)
{
// nothing to do
}
}// recovery registers
// finalize recovery
OnProcessUpdate?.Invoke(this, new ProcessExecEventArgs(Resources.StrRegisterRecoveryFinalization,
actualProcessMessage: Resources.StrRegisterRecoveryFinalization));
foreach (var finalRecReg in finalizeProgrammingAll)
{
ActualRegisterCtr++;
var overallProcessCtrPercent = 100.0 * ActualRegisterCtr / recRegistersCount;
try
{
_currentGenesis.WriteRegister(finalRecReg.RegisterName, finalRecReg.RegisterValue);
// if this call does not throw an exception, the register is present
var regDef = meterRegisters.GetRegisterDefinitionByName(finalRecReg.RegisterName);
var strRawAndConvertedValue = "";
try
{
strRawAndConvertedValue = RegisterConverter.GetRegisterContentText(regDef, finalRecReg.RegisterValue);
}
catch (Exception)
{
// nothing to do
}
finally
{
var actualProcessMsg = $"{Resources.StrWriteRegister}: {strRawAndConvertedValue} ";
OnProcessUpdate?.Invoke(this, new ProcessExecEventArgs($@"{Resources.StrWriteRegister}" + OnProcessUpdate?.Invoke(this, new ProcessExecEventArgs($@"{Resources.StrWriteRegister}" +
$@" {ActualRegisterCtr} / {recRegistersCount}", $@" {ActualRegisterCtr} / {recRegistersCount}",
overallProcessCtrPercent, actualProcessMsg)); overallProcessCtrPercent, actualProcessMsg));
@@ -263,11 +363,9 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
{ {
// nothing to do // nothing to do
} }
}// finalize recovery
}
_currentGenesis?.Logout(); _currentGenesis?.Logout();
return true; return true;
} }
@@ -25,9 +25,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisFile
{ {
#region Variables #region Variables
/// <summary> // process update feedback
/// Port scan result event for message dispatcher to caller
/// </summary>
public event EventHandler<ProcessExecEventArgs> OnProcessUpdate; public event EventHandler<ProcessExecEventArgs> OnProcessUpdate;
//disk and name of config file //disk and name of config file
@@ -267,6 +267,10 @@ namespace Xylem.ServiceFwUpdate.Common.FwUpdateDb
/// <remarks date="2023-10-19" author="Thomas Wiedebusch"> /// <remarks date="2023-10-19" author="Thomas Wiedebusch">
/// - Sort the registers from DB but keep the PrepareProgramming and FinalizeProgramming in the required sequence. /// - Sort the registers from DB but keep the PrepareProgramming and FinalizeProgramming in the required sequence.
/// </remarks> /// </remarks>
/// <remarks date="2023-10-25" author="Thomas Wiedebusch">
/// - Removed preparation and finalization of register recovery to remove sequencing as this will be done in the
/// RegisterRestorer by the FwUpdateSw worker giving the ability to log this in the report.
/// </remarks>
public Boolean DownloadCordonelRecoveryRegistersFromDb(String pcbId, out List<RecoveryRegisterItem> recoveryRegisters) public Boolean DownloadCordonelRecoveryRegistersFromDb(String pcbId, out List<RecoveryRegisterItem> recoveryRegisters)
{ {
recoveryRegisters = new List<RecoveryRegisterItem>(); recoveryRegisters = new List<RecoveryRegisterItem>();
@@ -293,7 +297,6 @@ namespace Xylem.ServiceFwUpdate.Common.FwUpdateDb
// finalization of programming and therefore building a sequence // finalization of programming and therefore building a sequence
var sortableProgrammingParameters = new List<ProgrammingParameters>(); var sortableProgrammingParameters = new List<ProgrammingParameters>();
foreach (var proPar in programmingParameters) foreach (var proPar in programmingParameters)
{ {
// reverse byte order for all parameters except those listed below // reverse byte order for all parameters except those listed below
@@ -337,22 +340,9 @@ namespace Xylem.ServiceFwUpdate.Common.FwUpdateDb
if (DbProgrammingParameters == null) if (DbProgrammingParameters == null)
DbProgrammingParameters = new List<ProgrammingParameters>(); DbProgrammingParameters = new List<ProgrammingParameters>();
// ATTENTION:
// Here the logical programming sequence will be built. Keep this sequence and do
// sort afterwards!
//
// Prepare meter for programming
DbProgrammingParameters.AddRange(RegisterRestorer.PrepareProgramming);
// Add the settings which should be dispatched to the meter to reconfigure it // Add the settings which should be dispatched to the meter to reconfigure it
DbProgrammingParameters.AddRange(sortableProgrammingParameters); DbProgrammingParameters.AddRange(sortableProgrammingParameters);
// Set all for parameters needed to finalize programming
DbProgrammingParameters.AddRange(RegisterRestorer.FinalizeProgramming);
// Add radio parameters if any radio setting can be detected
if (DbProgrammingParameters.Any(x => x.RegisterName.Contains("SENSUSRADIO")))
{
DbProgrammingParameters.AddRange(RegisterRestorer.FinalizeProgrammingRadioOnly);
}
// convert to RecoveryRegisterItem // convert to RecoveryRegisterItem
if (DbProgrammingParameters.Count > 0) if (DbProgrammingParameters.Count > 0)
{ {
@@ -48,6 +48,9 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
{ {
#region ------------------------------------------ Variables -------------------------------------------------- #region ------------------------------------------ Variables --------------------------------------------------
// process update feedback
public event EventHandler<ProcessExecEventArgs> OnProcessUpdate;
// Genesis (legacy and program internal name for Cordonel) // Genesis (legacy and program internal name for Cordonel)
private GenesisMeter _currentGenesis; private GenesisMeter _currentGenesis;
private readonly MeterBatch _meterBatch; private readonly MeterBatch _meterBatch;
@@ -2431,7 +2434,6 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
break; break;
case ProcessState.PortScan: case ProcessState.PortScan:
SetDisableDownloadAndEnableConnect(); SetDisableDownloadAndEnableConnect();
_meterBatch?.RemoveAllMeters();
MessageBoxShow(Resources.StrRequestPortFailed, Resources.StrMessageWindowFailed, MessageBoxShow(Resources.StrRequestPortFailed, Resources.StrMessageWindowFailed,
MessageBoxButtons.OK, MessageBoxIcon.Error); MessageBoxButtons.OK, MessageBoxIcon.Error);
break; break;
@@ -2493,12 +2495,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
_meterBatch?.RemoveAllMeters(); _meterBatch?.RemoveAllMeters();
_processState = ProcessState.Idle; _processState = ProcessState.Idle;
break; break;
case ProcessState.RestorePasswordFile:
_processState = ProcessState.Idle;
break;
default: default:
// to enable the "FW-Update" button again. _processState = ProcessState.Idle;
_processState = ProcessState.CheckUpdateCapability;
break; break;
} }
} }
@@ -134,8 +134,8 @@
</EmbeddedResource> </EmbeddedResource>
<EmbeddedResource Include="Properties\Resources.de.resx"> <EmbeddedResource Include="Properties\Resources.de.resx">
<Generator>ResXFileCodeGenerator</Generator> <Generator>ResXFileCodeGenerator</Generator>
<LastGenOutput>Resources.de.Designer.cs</LastGenOutput>
<SubType>Designer</SubType> <SubType>Designer</SubType>
<LastGenOutput>Resources.de1.Designer.cs</LastGenOutput>
</EmbeddedResource> </EmbeddedResource>
<EmbeddedResource Include="Properties\Resources.resx"> <EmbeddedResource Include="Properties\Resources.resx">
<Generator>ResXFileCodeGenerator</Generator> <Generator>ResXFileCodeGenerator</Generator>
@@ -159,6 +159,11 @@
<AutoGen>True</AutoGen> <AutoGen>True</AutoGen>
<DesignTime>True</DesignTime> <DesignTime>True</DesignTime>
</Compile> </Compile>
<Compile Include="Properties\Resources.de1.Designer.cs">
<AutoGen>True</AutoGen>
<DesignTime>True</DesignTime>
<DependentUpon>Resources.de.resx</DependentUpon>
</Compile>
<Compile Include="Properties\Resources.Designer.cs"> <Compile Include="Properties\Resources.Designer.cs">
<AutoGen>True</AutoGen> <AutoGen>True</AutoGen>
<DesignTime>True</DesignTime> <DesignTime>True</DesignTime>