VSFM omni+ 02-07-2024

This commit is contained in:
Stoyan Zlatev
2024-07-03 10:35:45 +02:00
parent dc0c0cacc7
commit 926676931e
130 changed files with 1327 additions and 4257 deletions
@@ -1,4 +1,4 @@
using Common.SqlExtensions;
using Common.Logic.Extensions.SQL;
using Newtonsoft.Json;
using System;
using System.Collections.Generic;
@@ -8,7 +8,6 @@ using System.Linq;
using System.Net;
using System.Net.Http;
using System.Text;
using System.Text.RegularExpressions;
using System.Threading.Tasks;
using System.Web;
using System.Web.Http;
@@ -1,6 +1,6 @@
namespace Xylem.Common.Service.MeterProcessState.Controllers
{
using global::Common.SqlExtensions;
using global::Common.Logic.Extensions.SQL;
using System;
using System.Collections.Generic;
@@ -9,6 +9,7 @@
using System.Net;
using System.Text;
using System.Web.Http;
using Xylem.Common.Logic.ProductionOrderCore.TestResults;
using Xylem.Common.Logic.ServiceCore;
@@ -17,19 +18,20 @@
{
public static class GlobalConfig
{
public static Lazy<String> connectionString = new Lazy<String>(()
=>
System.Configuration.ConfigurationManager.ConnectionStrings["default"].ConnectionString
);
public static Lazy<String> connectionString = new Lazy<String>(() => ConfigurationManager.ConnectionStrings["default"].ConnectionString);
}
public static readonly Lazy<String> ConnectionString = new Lazy<String>(()
=> ConfigurationManager.ConnectionStrings["default"].ConnectionString);
public static readonly Lazy<String> ConnectionString = new Lazy<String>(() => ConfigurationManager.ConnectionStrings["default"].ConnectionString);
/// <summary>
/// SetMeterLogPathInfo
/// </summary>
/// <param name="SerialNumber">PcbID from Meter</param>
///
/// <param name="TestRunId"> </param>
/// <param name="CalibrationRunId"> </param>
/// <param name="BasePath"> </param>
/// <param name="MainLogName"> </param>
/// <param name="LEDName"> </param>
/// <returns></returns>
[Route("SetMeterLogPathInfo"), HttpGet]
public IHttpActionResult SetMeterLogPathInfo(Int32 SerialNumber, Int32? TestRunId = null, Int32? CalibrationRunId = null, String BasePath = "", String MainLogName = "", String LEDName = "")
@@ -76,46 +78,6 @@
[Route("GetMeterInfoForTestBench"), HttpGet]
public IHttpActionResult GetMeterInfoForTestBench(String PcbID)
{
var str = $@"
SELECT DISTINCT
[MapPcbIdToSerialNumber_SerialNumber] AS [SerialNr]
, [MapOrder].[CordonelAssignedPicking_FertigungsAuftragsNr] AS [FertigungsNr]
, [Meter].[Adresse] AS [RadioAddress]
, [KundeneigeneSerienNr] AS [CustomerSerialNr]
, (SELECT TOP 1 [ID]
FROM [CordonelMeterCalibrationResults]
WHERE [PcbId] = @{nameof(PcbID)}
ORDER BY [Date] DESC) AS [CalibrationRunID]
, (SELECT TOP 1 [StatusFertigung]
FROM [AuftragPositionSerienNr]
WHERE [SerienNr] = [MapPcbIdToSerialNumber_SerialNumber]
ORDER BY [AnlageDatum] DESC) AS [LastProcessState]
, [Nennweite] AS [Dn]
, (SELECT TOP 1 [Dn_InternalId]
FROM [CordonelMeterSizes]
WHERE [Dn_VakoID] = SUBSTRING([Identnr].[VakoCode], 4, 2)) AS [NewNennweiteID]
, [lut].[FileCrc] AS [LutCrc]
FROM [Cordonel_AssignedPicking] AS [MapOrder]
LEFT OUTER JOIN [MapPcbIdToSerialNumber] AS [map]
ON [MapOrder].[CordonelAssignedPicking_PcbId] = [map].[MapPcbIdToSerialNumber_PcbId]
AND [map].[MapPcbIdToSerialNumber_Deleted] = 0
LEFT OUTER JOIN [AuftragPositionSerienNr] AS [mapSrn]
ON [map].[MapPcbIdToSerialNumber_SerialNumber] = [mapSrn].[SerienNr]
AND [mapSrn].[Pruefgangnr] = 0
LEFT OUTER JOIN [AuftragPosition_gesamt] AS [auftraginfo]
ON [auftraginfo].[AuftragNr] = [mapSrn].[AuftragNr]
AND [auftraginfo].[PositionNr] = [mapSrn].[PositionNr]
LEFT OUTER JOIN [Genesis_Meter] AS [Meter]
ON [Meter].[Seriennummer] = [map].[MapPcbIdToSerialNumber_SerialNumber]
LEFT OUTER JOIN [Identnr]
ON [auftraginfo].[Identnr] = [Identnr].[IdentNr]
LEFT OUTER JOIN [Cordonel_Lut] AS [lut]
ON [lut].[MeterSize] = (SELECT TOP 1 [Dn_InternalId]
FROM [CordonelMeterSizes]
WHERE [Dn_VakoID] = SUBSTRING([Identnr].[VakoCode], 4, 2))
AND [lut].[CurrentVersionForProd] = 1
WHERE [MapOrder].[CordonelAssignedPicking_IsDeleted] = 0
AND [MapOrder].[CordonelAssignedPicking_PcbId] = @{nameof(PcbID)} ";
var results = SQLConnection
.CreateSQLConnection(ConnectionString.Value)
.CreateCommand($@"
@@ -168,16 +130,16 @@
.SetParameter(nameof(PcbID), PcbID)
.ExecuteReader(x => new string[]
{
$"{x.GetInt()}", // SerialNr,
$"{x.GetInt()}", // FertigungsNr,
$"{x.GetLong()}", // RadioAddress,
$"{x.GetValue<int?>()}", // CustomerSerialNr,
$"{x.GetString()}", // CalibrationRunID,
$"{x.GetValue<byte>()}", // LastProcessState,
$"{x.GetInt()}", // Dn,
$"{x.GetInt()}", // NewNennweiteID,
$"{x.GetValue<int?>()}", // LutCrc
$"{x.GetValue<int?>()}", // Fwversion
$"{x.GetValue<Int32>(0)}", // SerialNr,
$"{x.GetValue<Int32>(1)}", // FertigungsNr,
$"{x.GetValue<Int64>(2)}", // RadioAddress,
$"{x.GetValue<Int32?>(3)}", // CustomerSerialNr,
$"{x.GetValue<String>(4)}", // CalibrationRunID,
$"{x.GetValue<Byte>(5)}", // LastProcessState,
$"{x.GetValue<Int32>(6)}", // Dn,
$"{x.GetValue<Int32>(7)}", // NewNennweiteID,
$"{x.GetValue<Int32?>(8)}", // LutCrc
$"{x.GetValue<Int32?>(9)}", // Fwversion
});
if (results.Count() == 1)
@@ -203,9 +165,9 @@
.SetParameter(nameof(pcbId), pcbId)
.FirstOrDefault(x => new CordonelCalibration
{
PcbId = x.GetInt(),
TestRunNr = x.GetInt(),
Offset = x.GetValue<double>()
PcbId = x.GetValue<Int32>(0),
TestRunNr = x.GetValue<Int32>(1),
Offset = x.GetValue<Double>(2)
});
return this.Ok();