MeasurementRecord: - NegativeReverseVolumeCm, ForwardVolumeCm and FLowRateCmPerH added,

MagFlux: - Streaming decoder multiplies reverse volume with -1.0 to create the negative reverse volume
This commit is contained in:
Thomas Wiedebusch
2023-06-07 12:41:48 +02:00
parent d9738efc46
commit 887fec808f
11 changed files with 30 additions and 27 deletions
+2 -2
View File
@@ -14,5 +14,5 @@ using System.Reflection;
//[assembly: AssemblyVersion("1.2.*.0")] //[assembly: AssemblyVersion("1.2.*.0")]
[assembly: AssemblyVersion("2.5.0.*")] [assembly: AssemblyVersion("2.6.0.*")]
[assembly: AssemblyFileVersion("2.5.0.0")] [assembly: AssemblyFileVersion("2.6.0.0")]
@@ -11,21 +11,6 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.DataPackages.MeasurementRecor
public class MagFluxRecord : MeasurementRecord public class MagFluxRecord : MeasurementRecord
{ {
/// <summary>
/// Reverse volume in cubic meters
/// </summary>
public Double ForwardVolumeCm;
/// <summary>
/// Reverse volume in cubic meters
/// </summary>
public Double ReverseVolumeCm;
/// <summary>
/// Flow rate in cubic meters per hour
/// </summary>
public Double FlowRateCmPh;
/// <summary> /// <summary>
/// Sensor Id of MagFlux /// Sensor Id of MagFlux
/// </summary> /// </summary>
@@ -54,7 +39,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.DataPackages.MeasurementRecor
{ {
var sb = new StringBuilder(); var sb = new StringBuilder();
sb = sb.Append($"Volume [m³]: {VolumeCm}").Append(StringDelimiter) sb = sb.Append($"Volume [m³]: {VolumeCm}").Append(StringDelimiter)
.Append($"Reverse Volume [m³]: {ReverseVolumeCm}").Append(StringDelimiter) .Append($"Negative Reverse Volume [m³]: {NegativeReverseVolumeCm}").Append(StringDelimiter)
.Append($"CPU Time [s]: {TimeS}").Append(StringDelimiter) .Append($"CPU Time [s]: {TimeS}").Append(StringDelimiter)
.Append($"FlowRate [m³/h]: {FlowRateCmPh}").Append(StringDelimiter) .Append($"FlowRate [m³/h]: {FlowRateCmPh}").Append(StringDelimiter)
.Append($"Status: 0x{StatusBits:X8}").Append(StringDelimiter) .Append($"Status: 0x{StatusBits:X8}").Append(StringDelimiter)
@@ -36,7 +36,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.StreamingProtocol
{ {
VolumeCm = 0.0, VolumeCm = 0.0,
ForwardVolumeCm = 0.0, ForwardVolumeCm = 0.0,
ReverseVolumeCm = 0.0, NegativeReverseVolumeCm = 0.0,
TimeS = 0.0, TimeS = 0.0,
FlowRateCmPh = 0.0, FlowRateCmPh = 0.0,
StatusBits = 0, StatusBits = 0,
@@ -178,6 +178,9 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.StreamingProtocol
/// <remarks date="2023-Jun-06" author="T.Wiedebusch"> /// <remarks date="2023-Jun-06" author="T.Wiedebusch">
/// - Calculated sum volume from forward- minus reverse-volume. /// - Calculated sum volume from forward- minus reverse-volume.
/// </remarks> /// </remarks>
/// <remarks date="2023-Jun-07" author="T.Wiedebusch">
/// - Reverse volume multiplied with -1.0 as the test bench expects a negative value for reverse volume.
/// </remarks>
private static void DecodeProtocolL(ref MagFluxRecord dataMagFluxRec, IList<String> fields) private static void DecodeProtocolL(ref MagFluxRecord dataMagFluxRec, IList<String> fields)
{ {
// time stamp attachment // time stamp attachment
@@ -189,11 +192,11 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.StreamingProtocol
// build result values // build result values
dataMagFluxRec.ForwardVolumeCm = UInt64.Parse(fields[(Int32)ProtLsubString.FwdVolume], dataMagFluxRec.ForwardVolumeCm = UInt64.Parse(fields[(Int32)ProtLsubString.FwdVolume],
NumberStyles.AllowHexSpecifier) * MilliLitersToCmFactor; NumberStyles.AllowHexSpecifier) * MilliLitersToCmFactor;
dataMagFluxRec.ReverseVolumeCm = UInt64.Parse(fields[(Int32)ProtLsubString.RevVolume], dataMagFluxRec.NegativeReverseVolumeCm = UInt64.Parse(fields[(Int32)ProtLsubString.RevVolume],
NumberStyles.AllowHexSpecifier) * MilliLitersToCmFactor; NumberStyles.AllowHexSpecifier) * MilliLitersToCmFactor * -1.0;
dataMagFluxRec.TimeS = UInt32.Parse(fields[(Int32)ProtLsubString.CpuTime], dataMagFluxRec.TimeS = UInt32.Parse(fields[(Int32)ProtLsubString.CpuTime],
NumberStyles.AllowHexSpecifier) * CpuTimeToSecondsFactor; NumberStyles.AllowHexSpecifier) * CpuTimeToSecondsFactor;
dataMagFluxRec.VolumeCm = dataMagFluxRec.ForwardVolumeCm - dataMagFluxRec.ReverseVolumeCm; dataMagFluxRec.VolumeCm = dataMagFluxRec.ForwardVolumeCm + dataMagFluxRec.NegativeReverseVolumeCm;
// parse the floating point value of the flow rate which is a string containing the hex value as 32 bit // parse the floating point value of the flow rate which is a string containing the hex value as 32 bit
var hex = UInt32.Parse(fields[(Int32)ProtLsubString.FlowRate], NumberStyles.AllowHexSpecifier); var hex = UInt32.Parse(fields[(Int32)ProtLsubString.FlowRate], NumberStyles.AllowHexSpecifier);
@@ -1 +1 @@
5ed75d99ee45ff67821090f1b3dbb001dd9e4fe3 1a3d4919c9c702245832d925951f2b7cb72fc333
@@ -19,6 +19,21 @@ namespace Xylem.Common.Metrology.Measurements
/// </summary> /// </summary>
public Double VolumeCm; public Double VolumeCm;
/// <summary>
/// Reverse volume in cubic meters
/// </summary>
public Double ForwardVolumeCm;
/// <summary>
/// Reverse volume in cubic meters as negative value
/// </summary>
public Double NegativeReverseVolumeCm;
/// <summary>
/// Flow rate in cubic meters per hour
/// </summary>
public Double FlowRateCmPh;
/// <summary> /// <summary>
/// Overflow volume /// Overflow volume
/// </summary> /// </summary>
@@ -1 +1 @@
0d85a5b3a7561b41163c20e5dc7713bcd0d65555 f64d563def603c89cafafa61a3219ba97e1e344c
+1 -1
View File
@@ -285,7 +285,7 @@ namespace Xylem.Common.Ui.MagFluxToolBox
{ {
tbxVolume.Text = $@"{e.NewData.VolumeCm:F3}"; tbxVolume.Text = $@"{e.NewData.VolumeCm:F3}";
tbxFwdVolume.Text = $@"{e.NewData.ForwardVolumeCm:F3}"; tbxFwdVolume.Text = $@"{e.NewData.ForwardVolumeCm:F3}";
tbxRevVolume.Text = $@"{e.NewData.ReverseVolumeCm:F3}"; tbxRevVolume.Text = $@"{e.NewData.NegativeReverseVolumeCm:F3}";
tbxFlowRate.Text = $@"{e.NewData.FlowRateCmPh:F3}"; tbxFlowRate.Text = $@"{e.NewData.FlowRateCmPh:F3}";
tbxStatus.Text = $@"0x{e.NewData.StatusBits:X8}"; tbxStatus.Text = $@"0x{e.NewData.StatusBits:X8}";
tbxTime.Text = $@"{e.NewData.TimeS:F3}"; tbxTime.Text = $@"{e.NewData.TimeS:F3}";
@@ -31,5 +31,5 @@ using System.Runtime.InteropServices;
// You can specify all the values or you can default the Build and Revision Numbers // You can specify all the values or you can default the Build and Revision Numbers
// by using the '*' as shown below: // by using the '*' as shown below:
// [assembly: AssemblyVersion("1.0.*")] // [assembly: AssemblyVersion("1.0.*")]
[assembly: AssemblyVersion("1.7.0.0")] [assembly: AssemblyVersion("1.8.0.0")]