Merge branch 'main' of https://slm.sms-esaap.com/la_operations/laa_production
Merge
This commit is contained in:
@@ -14,5 +14,5 @@ using System.Reflection;
|
|||||||
//[assembly: AssemblyVersion("1.2.*.0")]
|
//[assembly: AssemblyVersion("1.2.*.0")]
|
||||||
|
|
||||||
|
|
||||||
[assembly: AssemblyVersion("2.3.8.*")]
|
[assembly: AssemblyVersion("2.4.2.*")]
|
||||||
[assembly: AssemblyFileVersion("2.3.8.0")]
|
[assembly: AssemblyFileVersion("2.4.2.0")]
|
||||||
@@ -155,7 +155,7 @@
|
|||||||
</site>
|
</site>
|
||||||
<site name="MeterProcessState" id="2">
|
<site name="MeterProcessState" id="2">
|
||||||
<application path="/" applicationPool="Clr4IntegratedAppPool">
|
<application path="/" applicationPool="Clr4IntegratedAppPool">
|
||||||
<virtualDirectory path="/" physicalPath="C:\Users\drabesch_ro\Repo\lab\la_operations\laa_production\Common\Service\MeterProcessState" />
|
<virtualDirectory path="/" physicalPath="D:\Projekte\SENSUS_GitLab\laa_production\Common\Service\MeterProcessState" />
|
||||||
</application>
|
</application>
|
||||||
<bindings>
|
<bindings>
|
||||||
<binding protocol="http" bindingInformation="*:56011:localhost" />
|
<binding protocol="http" bindingInformation="*:56011:localhost" />
|
||||||
|
|||||||
@@ -594,7 +594,7 @@ namespace CordonelAssemblyLine.Model
|
|||||||
sbMSG.AppendLine($"Pcb = {meter.PcbId}");
|
sbMSG.AppendLine($"Pcb = {meter.PcbId}");
|
||||||
|
|
||||||
sbMSG.AppendLine($"POWERMON_TotalUsedSeconds = {genesisStatus.ExceededLifeTime_s}");
|
sbMSG.AppendLine($"POWERMON_TotalUsedSeconds = {genesisStatus.ExceededLifeTime_s}");
|
||||||
sbMSG.AppendLine($"POWERMON_TotalUsedCharge = {genesisStatus.DrainedBatteryPower_uAs}");
|
sbMSG.AppendLine($"POWERMON_TotalUsedCharge = {genesisStatus.DrainedBatteryLoad_uAs}");
|
||||||
sbMSG.AppendLine($"POWERMON_BatteryQuantity = {genesisStatus.BatteryQuantity}");
|
sbMSG.AppendLine($"POWERMON_BatteryQuantity = {genesisStatus.BatteryQuantity}");
|
||||||
sbMSG.AppendLine($"POWERMON_BatteryMilliAHrRating = {genesisStatus.InitialBatteryLoad_mAh}");
|
sbMSG.AppendLine($"POWERMON_BatteryMilliAHrRating = {genesisStatus.InitialBatteryLoad_mAh}");
|
||||||
sbMSG.AppendLine("");
|
sbMSG.AppendLine("");
|
||||||
|
|||||||
@@ -904,35 +904,44 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
|||||||
/// </returns>
|
/// </returns>
|
||||||
private RequestRecord LoginCommandToMeter(String password, Boolean runImmediately = true)
|
private RequestRecord LoginCommandToMeter(String password, Boolean runImmediately = true)
|
||||||
{
|
{
|
||||||
var regDef = _configRegister.GetRegisterDefinitionByName(Register.Configexchange.Password);
|
try
|
||||||
|
|
||||||
StopKeepSession();
|
|
||||||
//restore password if new password is zero
|
|
||||||
if (string.IsNullOrEmpty(password))
|
|
||||||
{
|
{
|
||||||
password = _password;
|
var regDef = _configRegister.GetRegisterDefinitionByName(Register.Configexchange.Password);
|
||||||
|
|
||||||
|
StopKeepSession();
|
||||||
|
//restore password if new password is zero
|
||||||
|
if (string.IsNullOrEmpty(password))
|
||||||
|
{
|
||||||
|
password = _password;
|
||||||
|
}
|
||||||
|
|
||||||
|
if (string.IsNullOrEmpty(password))
|
||||||
|
{
|
||||||
|
throw new AuthenticationException("Password is empty");
|
||||||
|
}
|
||||||
|
|
||||||
|
//set new password
|
||||||
|
_password = password;
|
||||||
|
_logger.Debug($"Slot:{Slot} - Login with password");
|
||||||
|
|
||||||
|
//Due to password is defined as uint96_t this direct communication will be used instead of
|
||||||
|
//WriteRegister. The data shouldn't be resorted MSB<->LSB like other unit data types!
|
||||||
|
var responseRecord = RequestProtocol.CommandToMeter(Commands.MultipleWriteData, regDef,
|
||||||
|
Encoding.ASCII.GetBytes(password), hideDataInLog: true);
|
||||||
|
if (runImmediately)
|
||||||
|
{
|
||||||
|
RequestProtocolProcess();
|
||||||
|
}
|
||||||
|
|
||||||
|
StartKeepSession();
|
||||||
|
return responseRecord;
|
||||||
|
}
|
||||||
|
catch (Exception e)
|
||||||
|
{
|
||||||
|
_logger.Error(e);
|
||||||
}
|
}
|
||||||
|
|
||||||
if (string.IsNullOrEmpty(password))
|
return null;
|
||||||
{
|
|
||||||
throw new AuthenticationException("Password is empty");
|
|
||||||
}
|
|
||||||
|
|
||||||
//set new password
|
|
||||||
_password = password;
|
|
||||||
_logger.Debug($"Slot:{Slot} - Login with password");
|
|
||||||
|
|
||||||
//Due to password is defined as uint96_t this direct communication will be used instead of
|
|
||||||
//WriteRegister. The data shouldn't be resorted MSB<->LSB like other unit data types!
|
|
||||||
var responseRecord = RequestProtocol.CommandToMeter(Commands.MultipleWriteData, regDef,
|
|
||||||
Encoding.ASCII.GetBytes(password), hideDataInLog: true);
|
|
||||||
if (runImmediately)
|
|
||||||
{
|
|
||||||
RequestProtocolProcess();
|
|
||||||
}
|
|
||||||
|
|
||||||
StartKeepSession();
|
|
||||||
return responseRecord;
|
|
||||||
}
|
}
|
||||||
/// <summary>
|
/// <summary>
|
||||||
/// Clear password to force new password reading
|
/// Clear password to force new password reading
|
||||||
@@ -1070,6 +1079,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
|||||||
/// <param name="password">password string to login</param>
|
/// <param name="password">password string to login</param>
|
||||||
/// <param name="runImmediately"> true = process command; false = add command to list. call
|
/// <param name="runImmediately"> true = process command; false = add command to list. call
|
||||||
/// <see cref="RequestProtocolProcess()"></see> to process login command </param>
|
/// <see cref="RequestProtocolProcess()"></see> to process login command </param>
|
||||||
|
/// <param name="skipReadMeterFwAndAssignRegisters"></param>
|
||||||
/// <returns></returns>
|
/// <returns></returns>
|
||||||
/// <remarks date="2019JAN01" author="drabesch">
|
/// <remarks date="2019JAN01" author="drabesch">
|
||||||
/// pass runImmediately for auto login
|
/// pass runImmediately for auto login
|
||||||
@@ -1083,7 +1093,11 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
|||||||
/// <remarks date="2023-Mar-06" author="Thomas Wiedebusch">
|
/// <remarks date="2023-Mar-06" author="Thomas Wiedebusch">
|
||||||
/// - Pulse module deactivated at login.
|
/// - Pulse module deactivated at login.
|
||||||
/// </remarks>
|
/// </remarks>
|
||||||
public Boolean Login(String password, Boolean runImmediately = true)
|
/// <remarks date="2023-Mar-07" author="Thomas Wiedebusch">
|
||||||
|
/// - REMOVED: Pulse module deactivated at login.
|
||||||
|
/// - Skip FW readout to quick connect being able to immediately switch off the pulse mode before App detection.
|
||||||
|
/// </remarks>
|
||||||
|
public Boolean Login(String password, Boolean runImmediately = true, Boolean skipReadMeterFwAndAssignRegisters = false)
|
||||||
{
|
{
|
||||||
|
|
||||||
var backupRetries = CommunicationConfig.RequestRetries;
|
var backupRetries = CommunicationConfig.RequestRetries;
|
||||||
@@ -1113,12 +1127,8 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
|||||||
IsDevelopmentUsage = true;
|
IsDevelopmentUsage = true;
|
||||||
}
|
}
|
||||||
|
|
||||||
if (!DeactivatePulseModule())
|
if (!skipReadMeterFwAndAssignRegisters)
|
||||||
{
|
ReadMeterFirmwareAndAssignRegisters();
|
||||||
_logger.Warn($"Slot:{Slot} - Pulse module deactivation failed!");
|
|
||||||
}
|
|
||||||
ReadMeterFirmwareAndAssignRegisters();
|
|
||||||
|
|
||||||
}
|
}
|
||||||
else
|
else
|
||||||
{
|
{
|
||||||
@@ -1472,36 +1482,6 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
|||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
/// <summary>
|
|
||||||
/// The pulse module interrupts and disturbs the IrDA communication. As quick fix the pulse module can be switched off,
|
|
||||||
/// as soon as a communication could be established. As the pulse output will only be switched on again, if a pulse
|
|
||||||
/// module is attached to the device, this pulse mode can be switched active instantaneously after deactivation.
|
|
||||||
/// </summary>
|
|
||||||
/// <remarks date="2023-Feb-13" author="Roland Drabesch/Thomas Wiedebusch">
|
|
||||||
/// - Initial.
|
|
||||||
/// </remarks>
|
|
||||||
private Boolean DeactivatePulseModule()
|
|
||||||
{
|
|
||||||
Boolean retVal;
|
|
||||||
try
|
|
||||||
{
|
|
||||||
var pulseMode = RegisterConverter.ConvertTo<Byte>(ReadRegister(Register.Mertrologyasst.PulseMode));
|
|
||||||
// if pulse mode is already set to 0 (OFF) return true
|
|
||||||
if (pulseMode == 0)
|
|
||||||
return true;
|
|
||||||
|
|
||||||
// write pulse mode temporary to 0 (OFF) and wait for result
|
|
||||||
retVal = WriteRegister(Register.Mertrologyasst.PulseMode, 0);
|
|
||||||
// instantaneously restore pulse mode to original value
|
|
||||||
retVal &= WriteRegister(Register.Mertrologyasst.PulseMode, pulseMode);
|
|
||||||
}
|
|
||||||
catch (Exception)
|
|
||||||
{
|
|
||||||
retVal = false;
|
|
||||||
}
|
|
||||||
|
|
||||||
return retVal;
|
|
||||||
}
|
|
||||||
/// <summary>
|
/// <summary>
|
||||||
/// Automatic login to meter enabled if logged out by lost authentication
|
/// Automatic login to meter enabled if logged out by lost authentication
|
||||||
/// </summary>
|
/// </summary>
|
||||||
@@ -1841,41 +1821,51 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
|||||||
public Boolean WriteRegister<T>(String reg, T value, Boolean waitForResult = true,
|
public Boolean WriteRegister<T>(String reg, T value, Boolean waitForResult = true,
|
||||||
Boolean checkRegister = false, UInt16 skipRetryErrorCode = CommunicationConfig.SkipRetryErrorCode)
|
Boolean checkRegister = false, UInt16 skipRetryErrorCode = CommunicationConfig.SkipRetryErrorCode)
|
||||||
{
|
{
|
||||||
var regDef = _configRegister.GetRegisterDefinitionByName(reg);
|
try
|
||||||
var data = RegisterConverter.ConvertFrom(value);
|
|
||||||
_logger.Info($"Slot:{Slot} - Write register({regDef.RegisterName}), " +
|
|
||||||
$"record({BitConverter.ToString(data.ToArray())})");
|
|
||||||
|
|
||||||
PreRegisterWrite(regDef, data);
|
|
||||||
|
|
||||||
var command = data.Length > RegisterDefinition.ChunkSize ?
|
|
||||||
Commands.MultipleWriteData : Commands.WriteData;
|
|
||||||
|
|
||||||
var responseRecord = RequestProtocol.CommandToMeter(command, regDef, data,
|
|
||||||
skipRetryErrorCode: skipRetryErrorCode);
|
|
||||||
|
|
||||||
if (!waitForResult && !checkRegister)
|
|
||||||
{
|
{
|
||||||
return true;
|
var regDef = _configRegister.GetRegisterDefinitionByName(reg);
|
||||||
}
|
var data = RegisterConverter.ConvertFrom(value);
|
||||||
|
_logger.Info($"Slot:{Slot} - Write register({regDef.RegisterName}), " +
|
||||||
|
$"record({BitConverter.ToString(data.ToArray())})");
|
||||||
|
|
||||||
RequestProtocolProcess();
|
PreRegisterWrite(regDef, data);
|
||||||
|
|
||||||
|
var command = data.Length > RegisterDefinition.ChunkSize ?
|
||||||
|
Commands.MultipleWriteData : Commands.WriteData;
|
||||||
|
|
||||||
|
var responseRecord = RequestProtocol.CommandToMeter(command, regDef, data,
|
||||||
|
skipRetryErrorCode: skipRetryErrorCode);
|
||||||
|
|
||||||
|
if (!waitForResult && !checkRegister)
|
||||||
|
{
|
||||||
|
return true;
|
||||||
|
}
|
||||||
|
|
||||||
|
RequestProtocolProcess();
|
||||||
|
|
||||||
|
//if register check by read back is not required we return the acknowledge state
|
||||||
|
if (!checkRegister || regDef.RegisterDetail.Privilege.Lvl8 == Registers.Access.Wo)
|
||||||
|
{
|
||||||
|
return responseRecord.Acknowledge == RequestAcknowledgeState.Ok;
|
||||||
|
}
|
||||||
|
|
||||||
|
var registerData = ReadRegister(reg, data.Length, skipRetryErrorCode);
|
||||||
|
//check if register read was okay and read and written data are EQUAL
|
||||||
|
if (registerData == null || registerData.Length < data.Length ||
|
||||||
|
data.Where((t, i) => registerData[i] != t).Any())
|
||||||
|
{
|
||||||
|
return false;
|
||||||
|
}
|
||||||
|
|
||||||
//if register check by read back is not required we return the acknowledge state
|
|
||||||
if (!checkRegister || regDef.RegisterDetail.Privilege.Lvl8 == Registers.Access.Wo)
|
|
||||||
{
|
|
||||||
return responseRecord.Acknowledge == RequestAcknowledgeState.Ok;
|
return responseRecord.Acknowledge == RequestAcknowledgeState.Ok;
|
||||||
}
|
|
||||||
|
|
||||||
var registerData = ReadRegister(reg, data.Length, skipRetryErrorCode);
|
}
|
||||||
//check if register read was okay and read and written data are EQUAL
|
catch (Exception e)
|
||||||
if (registerData == null || registerData.Length < data.Length ||
|
|
||||||
data.Where((t, i) => registerData[i] != t).Any())
|
|
||||||
{
|
{
|
||||||
return false;
|
_logger.Error(e);
|
||||||
}
|
}
|
||||||
|
|
||||||
return responseRecord.Acknowledge == RequestAcknowledgeState.Ok;
|
return false;
|
||||||
}
|
}
|
||||||
|
|
||||||
/// <summary>
|
/// <summary>
|
||||||
@@ -1889,25 +1879,34 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
|||||||
UInt16 skipRetryErrorCode = CommunicationConfig.SkipRetryErrorCode)
|
UInt16 skipRetryErrorCode = CommunicationConfig.SkipRetryErrorCode)
|
||||||
{
|
{
|
||||||
|
|
||||||
var regDef = _configRegister.GetRegisterDefinitionByName(reg);
|
try
|
||||||
_configRegister.Set(regDef, null);
|
{
|
||||||
_logger.Info($"Slot:{Slot} - Read register({regDef.RegisterName})");
|
var regDef = _configRegister.GetRegisterDefinitionByName(reg);
|
||||||
|
_configRegister.Set(regDef, null);
|
||||||
|
_logger.Info($"Slot:{Slot} - Read register({regDef.RegisterName})");
|
||||||
|
|
||||||
if (!expectedLength.HasValue || expectedLength.Value <= RegisterDefinition.ChunkSize)
|
if (!expectedLength.HasValue || expectedLength.Value <= RegisterDefinition.ChunkSize)
|
||||||
{
|
{
|
||||||
RequestProtocol?.CommandToMeter(Commands.ReadData, regDef,
|
RequestProtocol?.CommandToMeter(Commands.ReadData, regDef,
|
||||||
skipRetryErrorCode: skipRetryErrorCode);
|
skipRetryErrorCode: skipRetryErrorCode);
|
||||||
|
}
|
||||||
|
else
|
||||||
|
{
|
||||||
|
RequestProtocol?.CommandToMeter(Commands.MultipleReadData, regDef, expectedLength: expectedLength,
|
||||||
|
skipRetryErrorCode: skipRetryErrorCode);
|
||||||
|
}
|
||||||
|
|
||||||
|
RequestProtocolProcess();
|
||||||
|
var result = _configRegister.Get(reg);
|
||||||
|
PostRegisterRead(regDef, result);
|
||||||
|
return result;
|
||||||
}
|
}
|
||||||
else
|
catch (Exception e)
|
||||||
{
|
{
|
||||||
RequestProtocol?.CommandToMeter(Commands.MultipleReadData, regDef, expectedLength: expectedLength,
|
_logger.Error(e);
|
||||||
skipRetryErrorCode: skipRetryErrorCode);
|
|
||||||
}
|
}
|
||||||
|
|
||||||
RequestProtocolProcess();
|
return null;
|
||||||
var result = _configRegister.Get(reg);
|
|
||||||
PostRegisterRead(regDef, result);
|
|
||||||
return result;
|
|
||||||
}
|
}
|
||||||
|
|
||||||
/// <remarks date="2020-Dec-19" author="Thomas Wiedebusch">
|
/// <remarks date="2020-Dec-19" author="Thomas Wiedebusch">
|
||||||
|
|||||||
@@ -277,7 +277,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisFile
|
|||||||
}
|
}
|
||||||
if (genesisMeter.MeterAppListVersion.Any(f => f.AppName == "METROLOGYASST" && f.IsInstalled))
|
if (genesisMeter.MeterAppListVersion.Any(f => f.AppName == "METROLOGYASST" && f.IsInstalled))
|
||||||
{
|
{
|
||||||
_registersBeforeUpdate.Add(Register.Mertrologyasst.PulseMode, new Byte[] { 0 });
|
_registersBeforeUpdate.Add(Register.Metrologyasst.PulseMode, new Byte[] { 0 });
|
||||||
}
|
}
|
||||||
//deny access if NA product, because this does not have the radio app installed
|
//deny access if NA product, because this does not have the radio app installed
|
||||||
if (genesisMeter.MeterAppListVersion.Any(f => f.AppName == "SENSUSRADIO" && f.IsInstalled))
|
if (genesisMeter.MeterAppListVersion.Any(f => f.AppName == "SENSUSRADIO" && f.IsInstalled))
|
||||||
|
|||||||
@@ -178,7 +178,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisFile
|
|||||||
_registersBeforeUpdate.Add(Register.Genesisflow.SampleRate, new Byte[] { 1 });
|
_registersBeforeUpdate.Add(Register.Genesisflow.SampleRate, new Byte[] { 1 });
|
||||||
}
|
}
|
||||||
if (genesisMeter.MeterAppListVersion.Any(f => f.AppName == "METROLOGYASST" && f.IsInstalled))
|
if (genesisMeter.MeterAppListVersion.Any(f => f.AppName == "METROLOGYASST" && f.IsInstalled))
|
||||||
_registersBeforeUpdate.Add(Register.Mertrologyasst.PulseMode, new Byte[] { 0 });
|
_registersBeforeUpdate.Add(Register.Metrologyasst.PulseMode, new Byte[] { 0 });
|
||||||
//deny access if NA product, because this does not have the radio app installed
|
//deny access if NA product, because this does not have the radio app installed
|
||||||
if (genesisMeter.MeterAppListVersion.Any(f => f.AppName == "SENSUSRADIO" && f.IsInstalled))
|
if (genesisMeter.MeterAppListVersion.Any(f => f.AppName == "SENSUSRADIO" && f.IsInstalled))
|
||||||
_registersBeforeUpdate.Add(Register.Sensusradio.WakeupInterval, new Byte[] { 6 });
|
_registersBeforeUpdate.Add(Register.Sensusradio.WakeupInterval, new Byte[] { 6 });
|
||||||
|
|||||||
@@ -104,7 +104,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisStatus
|
|||||||
/// <summary>
|
/// <summary>
|
||||||
/// Drained capacity of all batteries in uAs.
|
/// Drained capacity of all batteries in uAs.
|
||||||
/// </summary>
|
/// </summary>
|
||||||
public UInt64 DrainedBatteryPower_uAs;
|
public UInt64 DrainedBatteryLoad_uAs;
|
||||||
|
|
||||||
/// <summary>
|
/// <summary>
|
||||||
/// Comment for approval and permissions reasons:
|
/// Comment for approval and permissions reasons:
|
||||||
|
|||||||
@@ -72,7 +72,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisStatus
|
|||||||
|
|
||||||
status.ExceededLifeTime_s = RegisterConverter.ConvertTo<UInt32>(
|
status.ExceededLifeTime_s = RegisterConverter.ConvertTo<UInt32>(
|
||||||
currentGenesis.ReadRegister(Register.Powermon.BatteryExceededSeconds));
|
currentGenesis.ReadRegister(Register.Powermon.BatteryExceededSeconds));
|
||||||
status.DrainedBatteryPower_uAs = RegisterConverter.ConvertTo<UInt64>(
|
status.DrainedBatteryLoad_uAs = RegisterConverter.ConvertTo<UInt64>(
|
||||||
currentGenesis.ReadRegister(Register.Powermon.BatteryDrainedLoad, 8));
|
currentGenesis.ReadRegister(Register.Powermon.BatteryDrainedLoad, 8));
|
||||||
status.BatteryQuantity = RegisterConverter.ConvertTo<Int32>(
|
status.BatteryQuantity = RegisterConverter.ConvertTo<Int32>(
|
||||||
currentGenesis.ReadRegister(Register.Powermon.BatteryQuantity));
|
currentGenesis.ReadRegister(Register.Powermon.BatteryQuantity));
|
||||||
@@ -105,7 +105,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisStatus
|
|||||||
var drainedBatteryLoad_rel = 1.0;
|
var drainedBatteryLoad_rel = 1.0;
|
||||||
if (initialBatteryLoad_uAs != 0)
|
if (initialBatteryLoad_uAs != 0)
|
||||||
{
|
{
|
||||||
drainedBatteryLoad_rel = (Double)status.DrainedBatteryPower_uAs / initialBatteryLoad_uAs;
|
drainedBatteryLoad_rel = (Double)status.DrainedBatteryLoad_uAs / initialBatteryLoad_uAs;
|
||||||
}
|
}
|
||||||
else
|
else
|
||||||
{
|
{
|
||||||
|
|||||||
@@ -79,7 +79,6 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.Registers
|
|||||||
public static readonly String FirstHitLvlUp2 = "GENESISFLOW_FirstHitLvlUp2";
|
public static readonly String FirstHitLvlUp2 = "GENESISFLOW_FirstHitLvlUp2";
|
||||||
public static readonly String FirstHitLvlUp3 = "GENESISFLOW_FirstHitLvlUp3";
|
public static readonly String FirstHitLvlUp3 = "GENESISFLOW_FirstHitLvlUp3";
|
||||||
public static readonly String StartHit = "GENESISFLOW_StartHit";
|
public static readonly String StartHit = "GENESISFLOW_StartHit";
|
||||||
|
|
||||||
public static readonly String NumFirePulses = "GENESISFLOW_NumFirePulses";
|
public static readonly String NumFirePulses = "GENESISFLOW_NumFirePulses";
|
||||||
public static readonly String LookupFileCrc = "GENESISFLOW_LookupFileCrc";
|
public static readonly String LookupFileCrc = "GENESISFLOW_LookupFileCrc";
|
||||||
|
|
||||||
@@ -92,6 +91,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.Registers
|
|||||||
public static readonly String BatteryDrainedLoad = "POWERMON_TotalUsedCharge";
|
public static readonly String BatteryDrainedLoad = "POWERMON_TotalUsedCharge";
|
||||||
public static readonly String BatteryInitialLoad = "POWERMON_BatteryMilliAHrRating";
|
public static readonly String BatteryInitialLoad = "POWERMON_BatteryMilliAHrRating";
|
||||||
public static readonly String BatteryExceededSeconds = "POWERMON_TotalUsedSeconds";
|
public static readonly String BatteryExceededSeconds = "POWERMON_TotalUsedSeconds";
|
||||||
|
public static readonly String StoreConfiguration = "POWERMON_StoreConfiguration";
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
||||||
@@ -100,9 +100,10 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.Registers
|
|||||||
public static readonly String FrequencyIndicator = "SENSUSRADIO_FrequencyIndicator";
|
public static readonly String FrequencyIndicator = "SENSUSRADIO_FrequencyIndicator";
|
||||||
public static readonly String WakeupInterval = "SENSUSRADIO_WakeupInterval";
|
public static readonly String WakeupInterval = "SENSUSRADIO_WakeupInterval";
|
||||||
public static readonly String SystemState = "SENSUSRADIO_SystemState";
|
public static readonly String SystemState = "SENSUSRADIO_SystemState";
|
||||||
|
public static readonly String StoreConfiguration = "SENSUSRADIO_StoreConfiguration";
|
||||||
}
|
}
|
||||||
|
|
||||||
public static class Mertrologyasst
|
public static class Metrologyasst
|
||||||
{
|
{
|
||||||
public static readonly String PulseMode = "METROLOGYASST_PulseMode";
|
public static readonly String PulseMode = "METROLOGYASST_PulseMode";
|
||||||
public static readonly String StoreConfiguration = "METROLOGYASST_StoreConfiguration";
|
public static readonly String StoreConfiguration = "METROLOGYASST_StoreConfiguration";
|
||||||
@@ -112,6 +113,10 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.Registers
|
|||||||
{
|
{
|
||||||
public static readonly String StoreConfiguration = "IRDA_StoreConfiguration";
|
public static readonly String StoreConfiguration = "IRDA_StoreConfiguration";
|
||||||
}
|
}
|
||||||
|
public static class Logger
|
||||||
|
{
|
||||||
|
public static readonly String StoreConfiguration = "LOGGER_StoreConfiguration";
|
||||||
|
}
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
@@ -119,6 +124,24 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.Registers
|
|||||||
{
|
{
|
||||||
return new List<String>()
|
return new List<String>()
|
||||||
{
|
{
|
||||||
|
System.CheckFwPresence,
|
||||||
|
System.CheckFwCrc,
|
||||||
|
System.TriggerFwUpgrade,
|
||||||
|
System.CoreRevision,
|
||||||
|
System.MonotonicSeconds,
|
||||||
|
System.MetrologyUpgradePermission,
|
||||||
|
|
||||||
|
Customer.AlarmStatus0,
|
||||||
|
Customer.AlarmStatus1,
|
||||||
|
Customer.TriggerAlarmCancel,
|
||||||
|
Customer.AlarmStatus2,
|
||||||
|
Customer.AlarmStatus3,
|
||||||
|
Customer.AlarmStatus4,
|
||||||
|
Customer.AlarmStatus5,
|
||||||
|
Customer.AlarmStatus6,
|
||||||
|
Customer.AlarmStatus7,
|
||||||
|
Customer.StoreConfiguration,
|
||||||
|
|
||||||
Configexchange.Privilege,
|
Configexchange.Privilege,
|
||||||
Configexchange.Password,
|
Configexchange.Password,
|
||||||
Configexchange.PcbSerialNumber,
|
Configexchange.PcbSerialNumber,
|
||||||
@@ -131,12 +154,6 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.Registers
|
|||||||
Configexchange.SetFilePointerOffset,
|
Configexchange.SetFilePointerOffset,
|
||||||
Configexchange.FileRemove,
|
Configexchange.FileRemove,
|
||||||
|
|
||||||
System.CheckFwPresence,
|
|
||||||
System.CheckFwCrc,
|
|
||||||
System.TriggerFwUpgrade,
|
|
||||||
System.CoreRevision,
|
|
||||||
System.MonotonicSeconds,
|
|
||||||
|
|
||||||
Genesisflow.TriggerActive,
|
Genesisflow.TriggerActive,
|
||||||
Genesisflow.TriggerIdle,
|
Genesisflow.TriggerIdle,
|
||||||
Genesisflow.LedMode,
|
Genesisflow.LedMode,
|
||||||
@@ -144,9 +161,26 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.Registers
|
|||||||
Genesisflow.MeterSize,
|
Genesisflow.MeterSize,
|
||||||
Genesisflow.LookupFileCrc,
|
Genesisflow.LookupFileCrc,
|
||||||
Genesisflow.StoreCalibration,
|
Genesisflow.StoreCalibration,
|
||||||
|
Genesisflow.StoreConfiguration,
|
||||||
|
|
||||||
|
Powermon.BatteryVoltage,
|
||||||
|
Powermon.BatteryQuantity,
|
||||||
|
Powermon.BatteryDrainedLoad,
|
||||||
|
Powermon.BatteryInitialLoad,
|
||||||
|
Powermon.BatteryExceededSeconds,
|
||||||
|
Powermon.StoreConfiguration,
|
||||||
|
|
||||||
Sensusradio.WakeupInterval,
|
Sensusradio.WakeupInterval,
|
||||||
Sensusradio.FrequencyIndicator
|
Sensusradio.FrequencyIndicator,
|
||||||
|
Sensusradio.SystemState,
|
||||||
|
Sensusradio.StoreConfiguration,
|
||||||
|
|
||||||
|
Metrologyasst.PulseMode,
|
||||||
|
Metrologyasst.StoreConfiguration,
|
||||||
|
|
||||||
|
Irda.StoreConfiguration,
|
||||||
|
|
||||||
|
Logger.StoreConfiguration
|
||||||
|
|
||||||
};
|
};
|
||||||
|
|
||||||
|
|||||||
@@ -121,7 +121,9 @@ namespace Xylem.Common.Hardware.WaterMeter.WaterMeterCore
|
|||||||
/// </summary>
|
/// </summary>
|
||||||
/// <param name="password">password for login</param>
|
/// <param name="password">password for login</param>
|
||||||
/// <param name="runImmediately">execute immediately</param>
|
/// <param name="runImmediately">execute immediately</param>
|
||||||
Boolean Login(String password, Boolean runImmediately = true);
|
/// <param name="skipReadMeterFwAndAssignRegisters">skip app readout and register generation to speed up
|
||||||
|
/// the initial connection process</param>
|
||||||
|
Boolean Login(String password, Boolean runImmediately = true, Boolean skipReadMeterFwAndAssignRegisters = false);
|
||||||
|
|
||||||
/// <summary>
|
/// <summary>
|
||||||
/// set up measurement parameter and set meter into test-mode
|
/// set up measurement parameter and set meter into test-mode
|
||||||
|
|||||||
+1
-1
@@ -1 +1 @@
|
|||||||
5ed75d99ee45ff67821090f1b3dbb001dd9e4fe3
|
1a3d4919c9c702245832d925951f2b7cb72fc333
|
||||||
|
|||||||
@@ -402,7 +402,7 @@ namespace Xylem.Common.Ui.GenesisToolBox
|
|||||||
Meter.SetLcdText(true, new Byte[] { 0x00, 0x00, 0x00, 0x01 });
|
Meter.SetLcdText(true, new Byte[] { 0x00, 0x00, 0x00, 0x01 });
|
||||||
|
|
||||||
Meter.ResetAlarm(GenesisMeter.Alarm.EMPTY_PIPE);//(true, new byte[] { 0x00, 0x00, 0x00, 0x01 });
|
Meter.ResetAlarm(GenesisMeter.Alarm.EMPTY_PIPE);//(true, new byte[] { 0x00, 0x00, 0x00, 0x01 });
|
||||||
_currentGenesis.WriteRegister(Register.Mertrologyasst.PulseMode, 5, true, true);
|
_currentGenesis.WriteRegister(Register.Metrologyasst.PulseMode, 5, true, true);
|
||||||
var useRadio = true;
|
var useRadio = true;
|
||||||
if (useRadio)
|
if (useRadio)
|
||||||
{
|
{
|
||||||
@@ -452,7 +452,7 @@ namespace Xylem.Common.Ui.GenesisToolBox
|
|||||||
|
|
||||||
if (_currentGenesis.Login())
|
if (_currentGenesis.Login())
|
||||||
{
|
{
|
||||||
_currentGenesis.WriteRegister(Register.Mertrologyasst.PulseMode, 0);
|
_currentGenesis.WriteRegister(Register.Metrologyasst.PulseMode, 0);
|
||||||
button6.Enabled = true;
|
button6.Enabled = true;
|
||||||
button7.Enabled = false;
|
button7.Enabled = false;
|
||||||
MessageBox.Show("Weiter");
|
MessageBox.Show("Weiter");
|
||||||
|
|||||||
@@ -77,6 +77,7 @@
|
|||||||
this.label3 = new System.Windows.Forms.Label();
|
this.label3 = new System.Windows.Forms.Label();
|
||||||
this.tbxFileToEraseDrive = new System.Windows.Forms.TextBox();
|
this.tbxFileToEraseDrive = new System.Windows.Forms.TextBox();
|
||||||
this.btnEraseFile = new System.Windows.Forms.Button();
|
this.btnEraseFile = new System.Windows.Forms.Button();
|
||||||
|
this.btnPulseModeOff = new System.Windows.Forms.Button();
|
||||||
this.grpSetup.SuspendLayout();
|
this.grpSetup.SuspendLayout();
|
||||||
((System.ComponentModel.ISupportInitialize)(this.pictureBox1)).BeginInit();
|
((System.ComponentModel.ISupportInitialize)(this.pictureBox1)).BeginInit();
|
||||||
this.groupBox1.SuspendLayout();
|
this.groupBox1.SuspendLayout();
|
||||||
@@ -356,6 +357,7 @@
|
|||||||
//
|
//
|
||||||
// groupBox1
|
// groupBox1
|
||||||
//
|
//
|
||||||
|
this.groupBox1.Controls.Add(this.btnPulseModeOff);
|
||||||
this.groupBox1.Controls.Add(this.btnTidyFile);
|
this.groupBox1.Controls.Add(this.btnTidyFile);
|
||||||
this.groupBox1.Controls.Add(this.btnGetDateTime);
|
this.groupBox1.Controls.Add(this.btnGetDateTime);
|
||||||
this.groupBox1.Controls.Add(this.btnSetDateTime);
|
this.groupBox1.Controls.Add(this.btnSetDateTime);
|
||||||
@@ -563,6 +565,16 @@
|
|||||||
this.btnEraseFile.UseVisualStyleBackColor = true;
|
this.btnEraseFile.UseVisualStyleBackColor = true;
|
||||||
this.btnEraseFile.Click += new System.EventHandler(this.btnEraseFile_Click);
|
this.btnEraseFile.Click += new System.EventHandler(this.btnEraseFile_Click);
|
||||||
//
|
//
|
||||||
|
// btnPulseModeOff
|
||||||
|
//
|
||||||
|
this.btnPulseModeOff.Location = new System.Drawing.Point(10, 205);
|
||||||
|
this.btnPulseModeOff.Name = "btnPulseModeOff";
|
||||||
|
this.btnPulseModeOff.Size = new System.Drawing.Size(116, 25);
|
||||||
|
this.btnPulseModeOff.TabIndex = 40;
|
||||||
|
this.btnPulseModeOff.Text = "Pulse Mode OFF";
|
||||||
|
this.btnPulseModeOff.UseVisualStyleBackColor = true;
|
||||||
|
this.btnPulseModeOff.Click += new System.EventHandler(this.btnPulseModeOff_Click);
|
||||||
|
//
|
||||||
// FrmLowLevelTools
|
// FrmLowLevelTools
|
||||||
//
|
//
|
||||||
this.AccessibleRole = System.Windows.Forms.AccessibleRole.Sound;
|
this.AccessibleRole = System.Windows.Forms.AccessibleRole.Sound;
|
||||||
@@ -656,5 +668,6 @@
|
|||||||
private System.Windows.Forms.Button btnEraseFile;
|
private System.Windows.Forms.Button btnEraseFile;
|
||||||
private System.Windows.Forms.Label label4;
|
private System.Windows.Forms.Label label4;
|
||||||
private System.Windows.Forms.TextBox tbxFileToEraseName;
|
private System.Windows.Forms.TextBox tbxFileToEraseName;
|
||||||
|
private System.Windows.Forms.Button btnPulseModeOff;
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
@@ -147,6 +147,7 @@ namespace Xylem.Common.Ui.GenesisToolBox
|
|||||||
/// </summary>
|
/// </summary>
|
||||||
private void DisableToolButtons()
|
private void DisableToolButtons()
|
||||||
{
|
{
|
||||||
|
btnPulseModeOff.Enabled = false;
|
||||||
btnClearDisplay.Enabled = false;
|
btnClearDisplay.Enabled = false;
|
||||||
btnSetDateTime.Enabled = false;
|
btnSetDateTime.Enabled = false;
|
||||||
btnGetDateTime.Enabled = false;
|
btnGetDateTime.Enabled = false;
|
||||||
@@ -167,6 +168,7 @@ namespace Xylem.Common.Ui.GenesisToolBox
|
|||||||
/// </summary>
|
/// </summary>
|
||||||
private void EnableToolButtons()
|
private void EnableToolButtons()
|
||||||
{
|
{
|
||||||
|
btnPulseModeOff.Enabled = true;
|
||||||
btnClearDisplay.Enabled = true;
|
btnClearDisplay.Enabled = true;
|
||||||
btnSetDateTime.Enabled = true;
|
btnSetDateTime.Enabled = true;
|
||||||
btnGetDateTime.Enabled = true;
|
btnGetDateTime.Enabled = true;
|
||||||
@@ -905,8 +907,12 @@ namespace Xylem.Common.Ui.GenesisToolBox
|
|||||||
|
|
||||||
_currentGenesis.SetLcdText(true, new Byte[] { 0x00, 0x00, 0x00, 0x00 });
|
_currentGenesis.SetLcdText(true, new Byte[] { 0x00, 0x00, 0x00, 0x00 });
|
||||||
|
|
||||||
// store configuration will logout
|
_currentGenesis.WriteRegister(Register.Genesisflow.StoreConfiguration, 1);
|
||||||
btnStoreConfiguration_Click(this, null);
|
|
||||||
|
//add a blank line to separate next operation
|
||||||
|
LogText("");
|
||||||
|
_currentGenesis.Logout();
|
||||||
|
LowLevelActionControl(false);
|
||||||
}
|
}
|
||||||
|
|
||||||
/// <summary>
|
/// <summary>
|
||||||
@@ -1115,8 +1121,12 @@ namespace Xylem.Common.Ui.GenesisToolBox
|
|||||||
|
|
||||||
LogPcAndCordonelTime();
|
LogPcAndCordonelTime();
|
||||||
|
|
||||||
// store configuration will logout
|
//add a blank line to separate next operation
|
||||||
btnStoreConfiguration_Click(this, null);
|
LogText("");
|
||||||
|
|
||||||
|
// SYSTEM does not support store configuration, just logout
|
||||||
|
_currentGenesis.Logout();
|
||||||
|
LowLevelActionControl(false);
|
||||||
}
|
}
|
||||||
|
|
||||||
/// <summary>
|
/// <summary>
|
||||||
@@ -1457,6 +1467,38 @@ namespace Xylem.Common.Ui.GenesisToolBox
|
|||||||
btnEraseFile_Click(this, null);
|
btnEraseFile_Click(this, null);
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
/// <summary>
|
||||||
|
/// Switch pulse mode to OFF
|
||||||
|
/// </summary>
|
||||||
|
/// <param name="sender"></param>
|
||||||
|
/// <param name="e"></param>
|
||||||
|
/// <remarks date="2023-Mar-08" author="Thomas Wiedebusch">
|
||||||
|
/// - Initial
|
||||||
|
/// </remarks>
|
||||||
|
private void btnPulseModeOff_Click(Object sender, EventArgs e)
|
||||||
|
{
|
||||||
|
if (_currentGenesis == null)
|
||||||
|
return;
|
||||||
|
|
||||||
|
//reset timer
|
||||||
|
_startTime = DateTimeOffset.UtcNow;
|
||||||
|
|
||||||
|
var msg = @"Switch pulse mode OFF";
|
||||||
|
LogText(msg);
|
||||||
|
lblActualProcess.Text = msg;
|
||||||
|
|
||||||
|
LowLevelActionControl(true);
|
||||||
|
_currentGenesis.ReLogin();
|
||||||
|
|
||||||
|
_currentGenesis.WriteRegister(Register.Metrologyasst.PulseMode, 0);
|
||||||
|
_currentGenesis.WriteRegister(Register.Metrologyasst.StoreConfiguration, 1);
|
||||||
|
|
||||||
|
//add a blank line to separate next operation
|
||||||
|
LogText("");
|
||||||
|
_currentGenesis.Logout();
|
||||||
|
LowLevelActionControl(false);
|
||||||
|
}
|
||||||
#endregion
|
#endregion
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
@@ -2224,7 +2224,7 @@ namespace Xylem.Common.Ui.GenesisToolBox
|
|||||||
sbMSG.AppendLine($"Pcb = {_currentGenesis.PcbId}");
|
sbMSG.AppendLine($"Pcb = {_currentGenesis.PcbId}");
|
||||||
|
|
||||||
sbMSG.AppendLine($"POWERMON_TotalUsedSeconds = {genesisStatus.ExceededLifeTime_s}");
|
sbMSG.AppendLine($"POWERMON_TotalUsedSeconds = {genesisStatus.ExceededLifeTime_s}");
|
||||||
sbMSG.AppendLine($"POWERMON_TotalUsedCharge = {genesisStatus.DrainedBatteryPower_uAs}");
|
sbMSG.AppendLine($"POWERMON_TotalUsedCharge = {genesisStatus.DrainedBatteryLoad_uAs}");
|
||||||
sbMSG.AppendLine($"POWERMON_BatteryQuantity = {genesisStatus.BatteryQuantity}");
|
sbMSG.AppendLine($"POWERMON_BatteryQuantity = {genesisStatus.BatteryQuantity}");
|
||||||
sbMSG.AppendLine($"POWERMON_BatteryMilliAHrRating = {genesisStatus.InitialBatteryLoad_mAh}");
|
sbMSG.AppendLine($"POWERMON_BatteryMilliAHrRating = {genesisStatus.InitialBatteryLoad_mAh}");
|
||||||
sbMSG.AppendLine("");
|
sbMSG.AppendLine("");
|
||||||
|
|||||||
@@ -24,6 +24,11 @@ namespace Xylem.ServiceFwUpdate.Common.FwUpdateConfig.Consts
|
|||||||
"Firmware ist aktuell!"
|
"Firmware ist aktuell!"
|
||||||
};
|
};
|
||||||
|
|
||||||
|
/// <summary>
|
||||||
|
/// Name of settings file being able to restores settings on crashed update procedure on next login.
|
||||||
|
/// </summary>
|
||||||
|
public const String RestoreSettingsFileName = "RestoreSettings.json";
|
||||||
|
|
||||||
/// <summary>
|
/// <summary>
|
||||||
/// Name of the file which contains the meter file names that can be erased before the FW-Update
|
/// Name of the file which contains the meter file names that can be erased before the FW-Update
|
||||||
/// to free disk space and have to be restored after the FW-Update
|
/// to free disk space and have to be restored after the FW-Update
|
||||||
|
|||||||
BIN
Binary file not shown.
BIN
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
@@ -1477,6 +1477,10 @@ namespace Xylem.ServiceFwUpdate.Ui.FwUpdateBuilder
|
|||||||
/// <remarks date="2023-Feb-24" author="Thomas Wiedebusch">
|
/// <remarks date="2023-Feb-24" author="Thomas Wiedebusch">
|
||||||
/// - Meter size check corrected.
|
/// - Meter size check corrected.
|
||||||
/// </remarks>
|
/// </remarks>
|
||||||
|
/// <remarks date="2023-Mar-17" author="Thomas Wiedebusch">
|
||||||
|
/// - FW-packages with multiple meter sizes supported in update capability check,
|
||||||
|
/// - FW-packages checked for multiple radio frequencies.
|
||||||
|
/// </remarks>
|
||||||
private String PreSelectFwPackages(CordonelProductionInfosDb cordonelDbInfo)
|
private String PreSelectFwPackages(CordonelProductionInfosDb cordonelDbInfo)
|
||||||
{
|
{
|
||||||
if (cordonelDbInfo == null)
|
if (cordonelDbInfo == null)
|
||||||
@@ -1495,110 +1499,141 @@ namespace Xylem.ServiceFwUpdate.Ui.FwUpdateBuilder
|
|||||||
return Constants.StrUnknown;
|
return Constants.StrUnknown;
|
||||||
}
|
}
|
||||||
|
|
||||||
// search in the list of all FW-packages infos for the user selected Id
|
// catch all meter sizes of a different entry but the identical FW-package references by name
|
||||||
foreach (var fw in _fwUpdateDbAccess.DbCordonelFwPackagesInfo)
|
var fwMeterSizes = new List<String>();
|
||||||
{
|
// catch multiple radio frequencies
|
||||||
// user selected Id
|
Int32? fwRadioFrequencyMhz = null;
|
||||||
if (_fwUpdatePackage.FwPackageInfo.Id != fw.Id)
|
Int32? fwCoreRevisionMax = null;
|
||||||
continue;
|
Int32? fwCoreRevisionMin = null;
|
||||||
|
Int32? fwMetrologyVersion = null;
|
||||||
|
var fwRegion = "";
|
||||||
|
|
||||||
|
// search in the list of all FW-packages infos for the user selected Id
|
||||||
|
foreach (var fw in _fwUpdateDbAccess.DbCordonelFwPackagesInfo.Where(
|
||||||
|
fw => _fwUpdatePackage.FwPackageInfo.Id == fw.Id))
|
||||||
|
{
|
||||||
|
// From here the FW-package is detected by its Id
|
||||||
// assign the unique version for all devices, even if these are having a lack of information
|
// assign the unique version for all devices, even if these are having a lack of information
|
||||||
cordonelDbInfo.RequiredReleaseNameVersion = fw.Name;
|
cordonelDbInfo.RequiredReleaseNameVersion = fw.Name;
|
||||||
|
fwRadioFrequencyMhz = fw.RadioFrequencyMhz;
|
||||||
|
fwCoreRevisionMax = fw.CoreRevisionMax;
|
||||||
|
fwCoreRevisionMin = fw.CoreRevisionMin;
|
||||||
|
fwMetrologyVersion = fw.MetrologyVersion;
|
||||||
|
fwRegion = fw.Region;
|
||||||
|
fwMeterSizes.Add(fw.MeterSize);
|
||||||
|
// As the first package has been found, the loop can be exited.
|
||||||
|
break;
|
||||||
|
}
|
||||||
|
|
||||||
try
|
// Collect all meter sizes and from identical FW-package(s)
|
||||||
|
foreach (var fw in _fwUpdateDbAccess.DbCordonelFwPackagesInfo.Where(
|
||||||
|
fw => fw.Name == cordonelDbInfo.RequiredReleaseNameVersion))
|
||||||
|
{
|
||||||
|
// on a package with multiple frequency support set the frequency to null to skip radio check
|
||||||
|
// in the FW-Update SW
|
||||||
|
if (fw.RadioFrequencyMhz != fwRadioFrequencyMhz)
|
||||||
{
|
{
|
||||||
var checkPassed = true;
|
fwRadioFrequencyMhz = null;
|
||||||
// if the installed version is unknown or not set, leave the approval to the user
|
}
|
||||||
if (string.IsNullOrEmpty(cordonelDbInfo.CoreRevision) || cordonelDbInfo.CoreRevision == Constants.StrUnknown)
|
|
||||||
|
// check multiple meter sizes in the FW-Update SW
|
||||||
|
if (fwMeterSizes.All(size => size != fw.MeterSize))
|
||||||
|
{
|
||||||
|
fwMeterSizes.Add(fw.MeterSize);
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
try
|
||||||
|
{
|
||||||
|
var checkPassed = true;
|
||||||
|
// if the installed version is unknown or not set, leave the approval to the user
|
||||||
|
if (string.IsNullOrEmpty(cordonelDbInfo.CoreRevision) || cordonelDbInfo.CoreRevision == Constants.StrUnknown)
|
||||||
|
{
|
||||||
|
cordonelDbInfo.ReasonForUpdateDenial = Resources.StrUpdateCapabilityCheckCore;
|
||||||
|
checkPassed = false;
|
||||||
|
}
|
||||||
|
else
|
||||||
|
{
|
||||||
|
// extract the Cordonel core version and validate it
|
||||||
|
var coreVersion = cordonelDbInfo.CoreRevision;
|
||||||
|
coreVersion = coreVersion.Replace(".", "");
|
||||||
|
Int32.TryParse(coreVersion, out var requiredCoreVersion);
|
||||||
|
if (requiredCoreVersion > fwCoreRevisionMax || requiredCoreVersion < fwCoreRevisionMin)
|
||||||
{
|
{
|
||||||
|
cordonelDbInfo.ReasonForUpdateDenial = "|";
|
||||||
cordonelDbInfo.ReasonForUpdateDenial = Resources.StrUpdateCapabilityCheckCore;
|
cordonelDbInfo.ReasonForUpdateDenial = Resources.StrUpdateCapabilityCheckCore;
|
||||||
checkPassed = false;
|
checkPassed = false;
|
||||||
}
|
}
|
||||||
else
|
|
||||||
{
|
|
||||||
// extract the Cordonel core version and validate it
|
|
||||||
var coreVersion = cordonelDbInfo.CoreRevision;
|
|
||||||
coreVersion = coreVersion.Replace(".", "");
|
|
||||||
Int32.TryParse(coreVersion, out var requiredCoreVersion);
|
|
||||||
if (requiredCoreVersion > fw.CoreRevisionMax || requiredCoreVersion < fw.CoreRevisionMin)
|
|
||||||
{
|
|
||||||
cordonelDbInfo.ReasonForUpdateDenial = Resources.StrUpdateCapabilityCheckCore;
|
|
||||||
checkPassed = false;
|
|
||||||
}
|
|
||||||
|
|
||||||
}
|
}
|
||||||
|
|
||||||
// check the completeness of information in DB of the Cordonel region
|
// check the completeness of information in DB of the Cordonel region
|
||||||
if (string.IsNullOrEmpty(cordonelDbInfo.Region) || cordonelDbInfo.Region != fw.Region)
|
if (string.IsNullOrEmpty(cordonelDbInfo.Region) || cordonelDbInfo.Region != fwRegion)
|
||||||
|
{
|
||||||
|
cordonelDbInfo.ReasonForUpdateDenial += "|";
|
||||||
|
cordonelDbInfo.ReasonForUpdateDenial += Resources.StrUpdateCapabilityCheckRegion;
|
||||||
|
checkPassed = false;
|
||||||
|
}
|
||||||
|
|
||||||
|
// check radio but skip check for NA region or if FW-package supports all frequencies indicated
|
||||||
|
// by null for the FW-package info frequency field
|
||||||
|
if (cordonelDbInfo.Region != "NA" && fwRadioFrequencyMhz != null)
|
||||||
|
{
|
||||||
|
// check the radio frequencies
|
||||||
|
if (string.IsNullOrEmpty(cordonelDbInfo.RadioFrequency)
|
||||||
|
|| cordonelDbInfo.RadioFrequency == Constants.StrUnknown
|
||||||
|
|| string.IsNullOrEmpty(fwRadioFrequencyMhz.ToString())
|
||||||
|
|| cordonelDbInfo.RadioFrequency != fwRadioFrequencyMhz.ToString())
|
||||||
{
|
{
|
||||||
cordonelDbInfo.ReasonForUpdateDenial += " ";
|
cordonelDbInfo.ReasonForUpdateDenial += "|";
|
||||||
cordonelDbInfo.ReasonForUpdateDenial += Resources.StrUpdateCapabilityCheckRegion;
|
cordonelDbInfo.ReasonForUpdateDenial += Resources.StrUpdateCapabilityCheckRadio;
|
||||||
checkPassed = false;
|
checkPassed = false;
|
||||||
}
|
}
|
||||||
|
}
|
||||||
|
|
||||||
// check radio but skip check for NA region or if FW-package supports all frequencies indicated
|
// if meter size does not fit and not for all meter sizes
|
||||||
// by null for the FW-package info frequency field
|
if (cordonelDbInfo.Diameter == Constants.StrUnknown
|
||||||
if (cordonelDbInfo.Region != "NA" && fw.RadioFrequencyMhz != null)
|
|| (fwMeterSizes.All(meterSize => meterSize != cordonelDbInfo.Diameter)
|
||||||
{
|
&& fwMeterSizes.Any( meterSize => meterSize != Constants.StrWildcard)))
|
||||||
// signal a non approved version
|
{
|
||||||
if (string.IsNullOrEmpty(cordonelDbInfo.RadioFrequency)
|
cordonelDbInfo.ReasonForUpdateDenial += "|";
|
||||||
|| cordonelDbInfo.RadioFrequency == Constants.StrUnknown
|
cordonelDbInfo.ReasonForUpdateDenial += Resources.StrUpdateCapabilityCheckMeterSize;
|
||||||
|| string.IsNullOrEmpty(fw.RadioFrequencyMhz.ToString())
|
checkPassed = false;
|
||||||
|| cordonelDbInfo.RadioFrequency != fw.RadioFrequencyMhz.ToString())
|
}
|
||||||
{
|
|
||||||
cordonelDbInfo.ReasonForUpdateDenial += " ";
|
|
||||||
cordonelDbInfo.ReasonForUpdateDenial += Resources.StrUpdateCapabilityCheckRadio;
|
|
||||||
checkPassed = false;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
// if meter size does not fit and not for all meter sizes
|
// if the installed version is unknown or not set, leave the approval to the user
|
||||||
if (string.IsNullOrEmpty(fw.MeterSize)
|
if (string.IsNullOrEmpty(cordonelDbInfo.Metrology) || cordonelDbInfo.Metrology == Constants.StrUnknown)
|
||||||
|| cordonelDbInfo.Diameter == Constants.StrUnknown
|
{
|
||||||
|| (fw.MeterSize != cordonelDbInfo.Diameter
|
cordonelDbInfo.ReasonForUpdateDenial += "|";
|
||||||
&& fw.MeterSize != Constants.StrWildcard))
|
cordonelDbInfo.ReasonForUpdateDenial += Resources.StrUpdateCapabilityCheckMetrokogy;
|
||||||
|
checkPassed = false;
|
||||||
|
}
|
||||||
|
else
|
||||||
|
{
|
||||||
|
// extract the metrology version and validate it
|
||||||
|
var metrologyVersion = cordonelDbInfo.Metrology;
|
||||||
|
metrologyVersion = metrologyVersion.Replace(".", "");
|
||||||
|
Int32.TryParse(metrologyVersion, out var requiredMetrologyVersion);
|
||||||
|
if (requiredMetrologyVersion != fwMetrologyVersion)
|
||||||
{
|
{
|
||||||
cordonelDbInfo.ReasonForUpdateDenial += " ";
|
cordonelDbInfo.ReasonForUpdateDenial += "|";
|
||||||
cordonelDbInfo.ReasonForUpdateDenial += Resources.StrUpdateCapabilityCheckMeterSize;
|
|
||||||
checkPassed = false;
|
|
||||||
}
|
|
||||||
|
|
||||||
// if the installed version is unknown or not set, leave the approval to the user
|
|
||||||
if (string.IsNullOrEmpty(cordonelDbInfo.Metrology) || cordonelDbInfo.Metrology == Constants.StrUnknown)
|
|
||||||
{
|
|
||||||
cordonelDbInfo.ReasonForUpdateDenial += " ";
|
|
||||||
cordonelDbInfo.ReasonForUpdateDenial += Resources.StrUpdateCapabilityCheckMetrokogy;
|
cordonelDbInfo.ReasonForUpdateDenial += Resources.StrUpdateCapabilityCheckMetrokogy;
|
||||||
checkPassed = false;
|
checkPassed = false;
|
||||||
}
|
}
|
||||||
else
|
|
||||||
{
|
|
||||||
// extract the metrology version and validate it
|
|
||||||
var metrologyVersion = cordonelDbInfo.Metrology;
|
|
||||||
metrologyVersion = metrologyVersion.Replace(".", "");
|
|
||||||
Int32.TryParse(metrologyVersion, out var requiredMetrologyVersion);
|
|
||||||
if (requiredMetrologyVersion != fw.MetrologyVersion )
|
|
||||||
{
|
|
||||||
cordonelDbInfo.ReasonForUpdateDenial += " ";
|
|
||||||
cordonelDbInfo.ReasonForUpdateDenial += Resources.StrUpdateCapabilityCheckMetrokogy;
|
|
||||||
checkPassed = false;
|
|
||||||
}
|
|
||||||
|
|
||||||
}
|
|
||||||
if (checkPassed)
|
|
||||||
{
|
|
||||||
cordonelDbInfo.IsRemoved = false;
|
|
||||||
cordonelDbInfo.IsApproved = true;
|
|
||||||
}
|
|
||||||
}
|
}
|
||||||
catch (Exception)
|
if (checkPassed)
|
||||||
{
|
{
|
||||||
return Constants.StrUnknown;
|
cordonelDbInfo.IsRemoved = false;
|
||||||
|
cordonelDbInfo.IsApproved = true;
|
||||||
}
|
}
|
||||||
|
}
|
||||||
return cordonelDbInfo.RequiredReleaseNameVersion;
|
catch (Exception)
|
||||||
|
{
|
||||||
|
return Constants.StrUnknown;
|
||||||
}
|
}
|
||||||
|
|
||||||
return Constants.StrUnknown;
|
return cordonelDbInfo.RequiredReleaseNameVersion;
|
||||||
}
|
}
|
||||||
|
|
||||||
/// <summary>
|
/// <summary>
|
||||||
@@ -2447,6 +2482,29 @@ namespace Xylem.ServiceFwUpdate.Ui.FwUpdateBuilder
|
|||||||
UiInvoker.ControlEnableInvoker(tabControlSelection, true);
|
UiInvoker.ControlEnableInvoker(tabControlSelection, true);
|
||||||
}
|
}
|
||||||
|
|
||||||
|
/// <summary>
|
||||||
|
/// Remove search items on FW-package pre-selection and deselect FW-package.
|
||||||
|
/// </summary>
|
||||||
|
/// <remarks date="2023-Mar-17" author="Thomas Wiedebusch">
|
||||||
|
/// - Initial.
|
||||||
|
/// </remarks>
|
||||||
|
private void DeselectFwPackageAndSearchMask()
|
||||||
|
{
|
||||||
|
// clear all search items for FW-Package as all cordonels are removed
|
||||||
|
_radioSearchItems.Clear();
|
||||||
|
_regionSearchItems.Clear();
|
||||||
|
_metrologySearchItems.Clear();
|
||||||
|
_coreSearchItems.Clear();
|
||||||
|
_sizeSearchItems.Clear();
|
||||||
|
// Clear FW-package selection
|
||||||
|
if (_fwUpdateDbAccess?.DbCordonelFwPackagesInfo != null)
|
||||||
|
{
|
||||||
|
foreach (var fw in _fwUpdateDbAccess.DbCordonelFwPackagesInfo)
|
||||||
|
fw.IsSelected = false;
|
||||||
|
_fwUpdatePackage = null;
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
#endregion --------------------------------------- Tools ------------------------------------------------------
|
#endregion --------------------------------------- Tools ------------------------------------------------------
|
||||||
|
|
||||||
#region ------------------------------------------ Threads and Tasks ------------------------------------------
|
#region ------------------------------------------ Threads and Tasks ------------------------------------------
|
||||||
@@ -2558,8 +2616,8 @@ namespace Xylem.ServiceFwUpdate.Ui.FwUpdateBuilder
|
|||||||
Thread.CurrentThread.CurrentCulture = _cultureInfo;
|
Thread.CurrentThread.CurrentCulture = _cultureInfo;
|
||||||
try
|
try
|
||||||
{
|
{
|
||||||
// check DB connection in advance to overcome the timing issues for DB service startup
|
// check DB connection in advance to overcome the timing issues for DB service startup
|
||||||
_fwUpdateDbAccess.CheckDbConnection();
|
_fwUpdateDbAccess.CheckDbConnection();
|
||||||
}
|
}
|
||||||
catch (Exception)
|
catch (Exception)
|
||||||
{
|
{
|
||||||
@@ -2592,8 +2650,8 @@ namespace Xylem.ServiceFwUpdate.Ui.FwUpdateBuilder
|
|||||||
Thread.CurrentThread.CurrentCulture = _cultureInfo;
|
Thread.CurrentThread.CurrentCulture = _cultureInfo;
|
||||||
try
|
try
|
||||||
{
|
{
|
||||||
// check DB connection in advance to overcome the timing issues for DB service startup
|
// check DB connection in advance to overcome the timing issues for DB service startup
|
||||||
_fwUpdateDbAccess.CheckDbConnection();
|
_fwUpdateDbAccess.CheckDbConnection();
|
||||||
GetAllUpdateOperatorsFromDb();
|
GetAllUpdateOperatorsFromDb();
|
||||||
}
|
}
|
||||||
catch (Exception)
|
catch (Exception)
|
||||||
@@ -2622,8 +2680,8 @@ namespace Xylem.ServiceFwUpdate.Ui.FwUpdateBuilder
|
|||||||
Thread.CurrentThread.CurrentCulture = _cultureInfo;
|
Thread.CurrentThread.CurrentCulture = _cultureInfo;
|
||||||
try
|
try
|
||||||
{
|
{
|
||||||
// check DB connection in advance to overcome the timing issues for DB service startup
|
// check DB connection in advance to overcome the timing issues for DB service startup
|
||||||
_fwUpdateDbAccess.CheckDbConnection();
|
_fwUpdateDbAccess.CheckDbConnection();
|
||||||
GetLicenseFromDb();
|
GetLicenseFromDb();
|
||||||
}
|
}
|
||||||
catch (Exception)
|
catch (Exception)
|
||||||
@@ -2657,10 +2715,10 @@ namespace Xylem.ServiceFwUpdate.Ui.FwUpdateBuilder
|
|||||||
Thread.CurrentThread.CurrentCulture = _cultureInfo;
|
Thread.CurrentThread.CurrentCulture = _cultureInfo;
|
||||||
try
|
try
|
||||||
{
|
{
|
||||||
// check DB connection in advance to overcome the timing issues for DB service startup
|
// check DB connection in advance to overcome the timing issues for DB service startup
|
||||||
_fwUpdateDbAccess.CheckDbConnection();
|
_fwUpdateDbAccess.CheckDbConnection();
|
||||||
// load the packages information
|
// load the packages information
|
||||||
GetCordonelFwPackagesInfosFromDb();
|
GetCordonelFwPackagesInfosFromDb();
|
||||||
}
|
}
|
||||||
catch (Exception)
|
catch (Exception)
|
||||||
{
|
{
|
||||||
@@ -2689,8 +2747,8 @@ namespace Xylem.ServiceFwUpdate.Ui.FwUpdateBuilder
|
|||||||
Thread.CurrentThread.CurrentCulture = _cultureInfo;
|
Thread.CurrentThread.CurrentCulture = _cultureInfo;
|
||||||
try
|
try
|
||||||
{
|
{
|
||||||
// check DB connection in advance to overcome the timing issues for DB service startup
|
// check DB connection in advance to overcome the timing issues for DB service startup
|
||||||
_fwUpdateDbAccess.CheckDbConnection();
|
_fwUpdateDbAccess.CheckDbConnection();
|
||||||
GetAndDisplaySingleReportFromDb();
|
GetAndDisplaySingleReportFromDb();
|
||||||
}
|
}
|
||||||
catch (Exception)
|
catch (Exception)
|
||||||
@@ -2718,8 +2776,8 @@ namespace Xylem.ServiceFwUpdate.Ui.FwUpdateBuilder
|
|||||||
Thread.CurrentThread.CurrentCulture = _cultureInfo;
|
Thread.CurrentThread.CurrentCulture = _cultureInfo;
|
||||||
try
|
try
|
||||||
{
|
{
|
||||||
// check DB connection in advance to overcome the timing issues for DB service startup
|
// check DB connection in advance to overcome the timing issues for DB service startup
|
||||||
_fwUpdateDbAccess.CheckDbConnection();
|
_fwUpdateDbAccess.CheckDbConnection();
|
||||||
GetReportsFromDb();
|
GetReportsFromDb();
|
||||||
}
|
}
|
||||||
catch (Exception)
|
catch (Exception)
|
||||||
@@ -2748,8 +2806,8 @@ namespace Xylem.ServiceFwUpdate.Ui.FwUpdateBuilder
|
|||||||
Thread.CurrentThread.CurrentCulture = _cultureInfo;
|
Thread.CurrentThread.CurrentCulture = _cultureInfo;
|
||||||
try
|
try
|
||||||
{
|
{
|
||||||
// check DB connection in advance to overcome the timing issues for DB service startup
|
// check DB connection in advance to overcome the timing issues for DB service startup
|
||||||
_fwUpdateDbAccess.CheckDbConnection();
|
_fwUpdateDbAccess.CheckDbConnection();
|
||||||
GetFwUpdateSafesInfosFromDb();
|
GetFwUpdateSafesInfosFromDb();
|
||||||
}
|
}
|
||||||
catch (Exception)
|
catch (Exception)
|
||||||
@@ -2784,8 +2842,8 @@ namespace Xylem.ServiceFwUpdate.Ui.FwUpdateBuilder
|
|||||||
Thread.CurrentThread.CurrentCulture = _cultureInfo;
|
Thread.CurrentThread.CurrentCulture = _cultureInfo;
|
||||||
try
|
try
|
||||||
{
|
{
|
||||||
// check DB connection in advance to overcome the timing issues for DB service startup
|
// check DB connection in advance to overcome the timing issues for DB service startup
|
||||||
_fwUpdateDbAccess.CheckDbConnection();
|
_fwUpdateDbAccess.CheckDbConnection();
|
||||||
GetAllCordonelCustomersFromDb();
|
GetAllCordonelCustomersFromDb();
|
||||||
}
|
}
|
||||||
catch (Exception)
|
catch (Exception)
|
||||||
@@ -2820,8 +2878,8 @@ namespace Xylem.ServiceFwUpdate.Ui.FwUpdateBuilder
|
|||||||
Thread.CurrentThread.CurrentCulture = _cultureInfo;
|
Thread.CurrentThread.CurrentCulture = _cultureInfo;
|
||||||
try
|
try
|
||||||
{
|
{
|
||||||
// check DB connection in advance to overcome the timing issues for DB service startup
|
// check DB connection in advance to overcome the timing issues for DB service startup
|
||||||
_fwUpdateDbAccess.CheckDbConnection();
|
_fwUpdateDbAccess.CheckDbConnection();
|
||||||
GetAllCordonelSerialNumbersOfOrderFromDb();
|
GetAllCordonelSerialNumbersOfOrderFromDb();
|
||||||
}
|
}
|
||||||
catch (Exception)
|
catch (Exception)
|
||||||
@@ -2853,8 +2911,8 @@ namespace Xylem.ServiceFwUpdate.Ui.FwUpdateBuilder
|
|||||||
Thread.CurrentThread.CurrentCulture = _cultureInfo;
|
Thread.CurrentThread.CurrentCulture = _cultureInfo;
|
||||||
try
|
try
|
||||||
{
|
{
|
||||||
// check DB connection in advance to overcome the timing issues for DB service startup
|
// check DB connection in advance to overcome the timing issues for DB service startup
|
||||||
_fwUpdateDbAccess.CheckDbConnection();
|
_fwUpdateDbAccess.CheckDbConnection();
|
||||||
GetAllCordonelOrdersOfCustomerFromDb();
|
GetAllCordonelOrdersOfCustomerFromDb();
|
||||||
}
|
}
|
||||||
catch (Exception)
|
catch (Exception)
|
||||||
@@ -3783,6 +3841,9 @@ namespace Xylem.ServiceFwUpdate.Ui.FwUpdateBuilder
|
|||||||
/// - Preselect order number and position to last production number to simplify update order generation,
|
/// - Preselect order number and position to last production number to simplify update order generation,
|
||||||
/// this will cause the update order-pos = production order-pos..
|
/// this will cause the update order-pos = production order-pos..
|
||||||
/// </remarks>
|
/// </remarks>
|
||||||
|
/// <remarks date="2023-Mar-17" author="Thomas Wiedebusch">
|
||||||
|
/// - Clear all search items for FW-package selection and deselect the FW-package if cordonel count is 0.
|
||||||
|
/// </remarks>
|
||||||
private void gridViewCordonelsSelection_CellClick(Object sender, DataGridViewCellEventArgs e)
|
private void gridViewCordonelsSelection_CellClick(Object sender, DataGridViewCellEventArgs e)
|
||||||
{
|
{
|
||||||
try
|
try
|
||||||
@@ -3793,14 +3854,7 @@ namespace Xylem.ServiceFwUpdate.Ui.FwUpdateBuilder
|
|||||||
return;
|
return;
|
||||||
}
|
}
|
||||||
|
|
||||||
// clear all search items for FW-Package selection
|
// the e.RowIndex is referenced to the (sorted) data grid view
|
||||||
_radioSearchItems.Clear();
|
|
||||||
_regionSearchItems.Clear();
|
|
||||||
_metrologySearchItems.Clear();
|
|
||||||
_coreSearchItems.Clear();
|
|
||||||
_sizeSearchItems.Clear();
|
|
||||||
|
|
||||||
// the e.RowIndex is referenced to the (sorted) data grid view
|
|
||||||
var cordSelect = new CordonelProductionInfosDb();
|
var cordSelect = new CordonelProductionInfosDb();
|
||||||
for (var columnIndex = 0; columnIndex < gridViewCordonelSelection.ColumnCount;
|
for (var columnIndex = 0; columnIndex < gridViewCordonelSelection.ColumnCount;
|
||||||
columnIndex++)
|
columnIndex++)
|
||||||
@@ -3840,12 +3894,12 @@ namespace Xylem.ServiceFwUpdate.Ui.FwUpdateBuilder
|
|||||||
if (_cordonelProductionPreSelectInfos.All(x => x.PcbId != cordSelect.PcbId))
|
if (_cordonelProductionPreSelectInfos.All(x => x.PcbId != cordSelect.PcbId))
|
||||||
_cordonelProductionPreSelectInfos.Add(cordSearch);
|
_cordonelProductionPreSelectInfos.Add(cordSearch);
|
||||||
// fill text box for update order
|
// fill text box for update order
|
||||||
if (cordSearch.CustomerOrderNumber > 0 )
|
if (cordSearch.CustomerOrderNumber > 0)
|
||||||
{
|
{
|
||||||
tbxOrderNumber.Text = cordSearch.CustomerOrderNumber.ToString();
|
tbxOrderNumber.Text = cordSearch.CustomerOrderNumber.ToString();
|
||||||
}
|
}
|
||||||
// fill text box for update position
|
// fill text box for update position
|
||||||
if (cordSearch.CustomerOrderPos > 0 )
|
if (cordSearch.CustomerOrderPos > 0)
|
||||||
{
|
{
|
||||||
tbxOrderPosition.Text = cordSearch.CustomerOrderPos.ToString();
|
tbxOrderPosition.Text = cordSearch.CustomerOrderPos.ToString();
|
||||||
}
|
}
|
||||||
@@ -3901,6 +3955,11 @@ namespace Xylem.ServiceFwUpdate.Ui.FwUpdateBuilder
|
|||||||
}// Search the cordonel in the production search list
|
}// Search the cordonel in the production search list
|
||||||
}
|
}
|
||||||
|
|
||||||
|
if (_cordonelProductionPreSelectInfos == null || _cordonelProductionPreSelectInfos.Count == 0)
|
||||||
|
{
|
||||||
|
DeselectFwPackageAndSearchMask();
|
||||||
|
}
|
||||||
|
|
||||||
_cordonelsPropertyChanged = false;
|
_cordonelsPropertyChanged = false;
|
||||||
}
|
}
|
||||||
catch (Exception)
|
catch (Exception)
|
||||||
@@ -4302,6 +4361,10 @@ namespace Xylem.ServiceFwUpdate.Ui.FwUpdateBuilder
|
|||||||
/// <remarks date="2021-Apr-17" author="Thomas Wiedebusch">
|
/// <remarks date="2021-Apr-17" author="Thomas Wiedebusch">
|
||||||
/// - Production pre select infos from production search infos.
|
/// - Production pre select infos from production search infos.
|
||||||
/// </remarks>
|
/// </remarks>
|
||||||
|
/// <remarks date="2023-Mar-17" author="Thomas Wiedebusch">
|
||||||
|
/// - Clear all search items for FW-package selection and deselect the FW-package as on customer change
|
||||||
|
/// everything needs to be renewed.
|
||||||
|
/// </remarks>
|
||||||
private void gridViewCustomerSelection_CellClick(Object sender, DataGridViewCellEventArgs e)
|
private void gridViewCustomerSelection_CellClick(Object sender, DataGridViewCellEventArgs e)
|
||||||
{
|
{
|
||||||
try
|
try
|
||||||
@@ -4311,6 +4374,9 @@ namespace Xylem.ServiceFwUpdate.Ui.FwUpdateBuilder
|
|||||||
return;
|
return;
|
||||||
}
|
}
|
||||||
|
|
||||||
|
// remove FW-package on customer change
|
||||||
|
DeselectFwPackageAndSearchMask();
|
||||||
|
|
||||||
// the e.RowIndex is referenced to the (sorted) data grid view
|
// the e.RowIndex is referenced to the (sorted) data grid view
|
||||||
var customerNumber = 0L;
|
var customerNumber = 0L;
|
||||||
for (var columnIndex = 0; columnIndex < gridViewCustomerSelection.ColumnCount; columnIndex++)
|
for (var columnIndex = 0; columnIndex < gridViewCustomerSelection.ColumnCount; columnIndex++)
|
||||||
|
|||||||
@@ -145,6 +145,11 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
// path and name of the installed applications
|
// path and name of the installed applications
|
||||||
private String _pathNameCordonelAppVersionFile;
|
private String _pathNameCordonelAppVersionFile;
|
||||||
|
|
||||||
|
// path and name of the restore settings file on crashed application or interrupted update
|
||||||
|
private String _pathNameCordonelRegisterRestoreSettingsFile;
|
||||||
|
// Register subset needed to adjust for update performance content before update
|
||||||
|
private Dictionary<String, Byte[]> _pulseModeRegistersRestore = new Dictionary<String, Byte[]>();
|
||||||
|
|
||||||
// loading the lists of meter files which shall be erased before the FW-Update and restored after.
|
// loading the lists of meter files which shall be erased before the FW-Update and restored after.
|
||||||
private MeterFilesEraseRestore _meterFilesEraseRestore;
|
private MeterFilesEraseRestore _meterFilesEraseRestore;
|
||||||
|
|
||||||
@@ -370,6 +375,7 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
|
|
||||||
case ProcessState.FirmwareUpdateSuccess:
|
case ProcessState.FirmwareUpdateSuccess:
|
||||||
ReleaseDisplay();
|
ReleaseDisplay();
|
||||||
|
RestoreRegisters();
|
||||||
FwUpdateSuccessMessage();
|
FwUpdateSuccessMessage();
|
||||||
_processState = ProcessState.Idle;
|
_processState = ProcessState.Idle;
|
||||||
break;
|
break;
|
||||||
@@ -979,9 +985,9 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
|
|
||||||
try
|
try
|
||||||
{
|
{
|
||||||
if (_cordonelDeviceInfos == null
|
if (_cordonelDeviceInfos == null
|
||||||
|| _cordonelFirmwarePackage?.FwPackageInfo == null
|
|| _cordonelFirmwarePackage?.FwPackageInfo == null
|
||||||
|| _cordonelFirmwarePackage.BinaryApplicationFiles == null
|
|| _cordonelFirmwarePackage.BinaryApplicationFiles == null
|
||||||
|| _cordonelFirmwarePackage.BinaryApplicationFiles.Count == 0
|
|| _cordonelFirmwarePackage.BinaryApplicationFiles.Count == 0
|
||||||
|| _cordonelFirmwarePackage.PackageDescriptionFile == null)
|
|| _cordonelFirmwarePackage.PackageDescriptionFile == null)
|
||||||
{
|
{
|
||||||
@@ -997,7 +1003,7 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
{
|
{
|
||||||
// here the firmware package is valid, encode content
|
// here the firmware package is valid, encode content
|
||||||
var encoding = new ASCIIEncoding();
|
var encoding = new ASCIIEncoding();
|
||||||
var packageFile =
|
var packageFile =
|
||||||
encoding.GetString(_cordonelFirmwarePackage.PackageDescriptionFile.FileContent.ToArray());
|
encoding.GetString(_cordonelFirmwarePackage.PackageDescriptionFile.FileContent.ToArray());
|
||||||
|
|
||||||
// setup package description file in FwUpdate class
|
// setup package description file in FwUpdate class
|
||||||
@@ -1211,8 +1217,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
// set information of required and detected versions, check failed!
|
// set information of required and detected versions, check failed!
|
||||||
LogText(StrSeparator);
|
LogText(StrSeparator);
|
||||||
LogErrorText(Resources.StrCoreRevision);
|
LogErrorText(Resources.StrCoreRevision);
|
||||||
LogErrorText(@"Minimum :" + _meterFwUpdate.CoreRevisionMinimum/100 + ":" + _meterFwUpdate.CoreRevisionMinimum%100);
|
LogErrorText(@"Minimum :" + _meterFwUpdate.CoreRevisionMinimum / 100 + ":" + _meterFwUpdate.CoreRevisionMinimum % 100);
|
||||||
LogErrorText(@"Maximum :" + _meterFwUpdate.CoreRevisionMaximum/100 + "." + _meterFwUpdate.CoreRevisionMaximum%100 );
|
LogErrorText(@"Maximum :" + _meterFwUpdate.CoreRevisionMaximum / 100 + "." + _meterFwUpdate.CoreRevisionMaximum % 100);
|
||||||
LogErrorText(@"Cordonel :" + GenesisMeter.BuildFwVersionString(_currentGenesis.CoreRevision));
|
LogErrorText(@"Cordonel :" + GenesisMeter.BuildFwVersionString(_currentGenesis.CoreRevision));
|
||||||
InfoProcessFailed(lblCordonelUpdateCapability, Resources.StrCordonelUpdateCapabilityCoreFailed);
|
InfoProcessFailed(lblCordonelUpdateCapability, Resources.StrCordonelUpdateCapabilityCoreFailed);
|
||||||
_processState = ProcessState.Error;
|
_processState = ProcessState.Error;
|
||||||
@@ -1279,12 +1285,12 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
// extract the package information
|
// extract the package information
|
||||||
var fwPackRegion = _cordonelFirmwarePackage.FwPackageInfo.Region;
|
var fwPackRegion = _cordonelFirmwarePackage.FwPackageInfo.Region;
|
||||||
var fwPackRadioFrequencyMhz = _cordonelFirmwarePackage.FwPackageInfo.RadioFrequencyMhz;
|
var fwPackRadioFrequencyMhz = _cordonelFirmwarePackage.FwPackageInfo.RadioFrequencyMhz;
|
||||||
|
|
||||||
// region
|
// region
|
||||||
if (!string.IsNullOrEmpty(fwPackRegion))
|
if (!string.IsNullOrEmpty(fwPackRegion))
|
||||||
{
|
{
|
||||||
// accept region if identical, on undefined installed region or support for all regions
|
// accept region if identical, on undefined installed region or support for all regions
|
||||||
if (_currentGenesis.Region == fwPackRegion
|
if (_currentGenesis.Region == fwPackRegion
|
||||||
|| Constants.StrWildcard == fwPackRegion
|
|| Constants.StrWildcard == fwPackRegion
|
||||||
|| Constants.StrUnknown == _currentGenesis.Region)
|
|| Constants.StrUnknown == _currentGenesis.Region)
|
||||||
{
|
{
|
||||||
@@ -1303,7 +1309,7 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
|
|
||||||
// if radio frequency is null the region is "NA" or the fw package serves all frequencies,
|
// if radio frequency is null the region is "NA" or the fw package serves all frequencies,
|
||||||
// if the radio frequency is explicit set, it has to be verified against the preset value in the Cordonel
|
// if the radio frequency is explicit set, it has to be verified against the preset value in the Cordonel
|
||||||
if (fwPackRadioFrequencyMhz == null || fwPackRadioFrequencyMhz == _currentGenesis.RadioFrequencyMhz
|
if (fwPackRadioFrequencyMhz == null || fwPackRadioFrequencyMhz == _currentGenesis.RadioFrequencyMhz
|
||||||
|| _currentGenesis.RadioFrequencyMhz == null)
|
|| _currentGenesis.RadioFrequencyMhz == null)
|
||||||
{
|
{
|
||||||
InfoProcessSuccess(null, Resources.StrCordonelUpdateCapabilityRadioSucceeded);
|
InfoProcessSuccess(null, Resources.StrCordonelUpdateCapabilityRadioSucceeded);
|
||||||
@@ -1317,8 +1323,9 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
LogErrorText(@"Cordonel: " + _currentGenesis.RadioFrequencyMhz + " MHz");
|
LogErrorText(@"Cordonel: " + _currentGenesis.RadioFrequencyMhz + " MHz");
|
||||||
InfoProcessFailed(lblCordonelUpdateCapability, Resources.StrCordonelUpdateCapabilityRadioFailed);
|
InfoProcessFailed(lblCordonelUpdateCapability, Resources.StrCordonelUpdateCapabilityRadioFailed);
|
||||||
}
|
}
|
||||||
|
|
||||||
if (!retVal) _processState = ProcessState.Error;
|
if (!retVal)
|
||||||
|
_processState = ProcessState.Error;
|
||||||
return retVal;
|
return retVal;
|
||||||
}
|
}
|
||||||
|
|
||||||
@@ -1331,7 +1338,7 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
/// for this update capability check.
|
/// for this update capability check.
|
||||||
/// </summary>
|
/// </summary>
|
||||||
/// <returns>true if meter size is approved</returns>
|
/// <returns>true if meter size is approved</returns>
|
||||||
/// <remarks date="2023-Feb-23" author="Thomas Wiedebusch">
|
/// <remarks date="2023-Feb-23" author="Thomas Wiedebusch">
|
||||||
/// - Initial.
|
/// - Initial.
|
||||||
/// </remarks>
|
/// </remarks>
|
||||||
private Boolean MeterSizeUpdateCapability()
|
private Boolean MeterSizeUpdateCapability()
|
||||||
@@ -1343,7 +1350,7 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
|
|
||||||
// extract the package information
|
// extract the package information
|
||||||
var fwPackMeterSizes = _cordonelFirmwarePackage.FwPackageInfo.MeterSizes;
|
var fwPackMeterSizes = _cordonelFirmwarePackage.FwPackageInfo.MeterSizes;
|
||||||
|
|
||||||
// meter size
|
// meter size
|
||||||
if (fwPackMeterSizes != null && fwPackMeterSizes.Count > 0)
|
if (fwPackMeterSizes != null && fwPackMeterSizes.Count > 0)
|
||||||
{
|
{
|
||||||
@@ -1351,7 +1358,7 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
// if fw package supports all meter sizes or the meter size is unknown
|
// if fw package supports all meter sizes or the meter size is unknown
|
||||||
if (fwPackMeterSizes.Any(size => size == _currentGenesis.MeterSize)
|
if (fwPackMeterSizes.Any(size => size == _currentGenesis.MeterSize)
|
||||||
|| fwPackMeterSizes.Any(size => size == Constants.StrWildcard)
|
|| fwPackMeterSizes.Any(size => size == Constants.StrWildcard)
|
||||||
|| Constants.StrUnknown == _currentGenesis.MeterSize )
|
|| Constants.StrUnknown == _currentGenesis.MeterSize)
|
||||||
{
|
{
|
||||||
InfoProcessSuccess(null, Resources.StrCordonelUpdateCapabilityMeterSizeSucceeded);
|
InfoProcessSuccess(null, Resources.StrCordonelUpdateCapabilityMeterSizeSucceeded);
|
||||||
}
|
}
|
||||||
@@ -1365,7 +1372,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
foreach (var size in fwPackMeterSizes)
|
foreach (var size in fwPackMeterSizes)
|
||||||
{
|
{
|
||||||
msg += size;
|
msg += size;
|
||||||
if (--cnt > 0) msg += ", ";
|
if (--cnt > 0)
|
||||||
|
msg += ", ";
|
||||||
}
|
}
|
||||||
LogErrorText(Resources.StrFwPackageInfo + msg);
|
LogErrorText(Resources.StrFwPackageInfo + msg);
|
||||||
LogErrorText(@"Cordonel: " + _currentGenesis.MeterSize);
|
LogErrorText(@"Cordonel: " + _currentGenesis.MeterSize);
|
||||||
@@ -1373,7 +1381,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
if (!retVal) _processState = ProcessState.Error;
|
if (!retVal)
|
||||||
|
_processState = ProcessState.Error;
|
||||||
return retVal;
|
return retVal;
|
||||||
}
|
}
|
||||||
|
|
||||||
@@ -1541,6 +1550,9 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
/// 3. login
|
/// 3. login
|
||||||
/// 4. read if not 0x01.
|
/// 4. read if not 0x01.
|
||||||
/// </remarks>
|
/// </remarks>
|
||||||
|
/// <remarks date="2023-Mar-07" author="Thomas Wiedebusch">
|
||||||
|
/// - Handle SystemState 0 = OFF
|
||||||
|
/// </remarks>
|
||||||
private Boolean ActivateRadio()
|
private Boolean ActivateRadio()
|
||||||
{
|
{
|
||||||
if (_currentGenesis == null)
|
if (_currentGenesis == null)
|
||||||
@@ -1550,7 +1562,9 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
try
|
try
|
||||||
{
|
{
|
||||||
// read initially if radio is NOT in production mode (0x01), where it sends unencrypted radio telegrams
|
// read initially if radio is NOT in production mode (0x01), where it sends unencrypted radio telegrams
|
||||||
if ( 0x01 != RegisterConverter.ConvertTo<Int32>(_currentGenesis.ReadRegister(Register.Sensusradio.SystemState)))
|
var radioSystemState =
|
||||||
|
RegisterConverter.ConvertTo<Int32>(_currentGenesis.ReadRegister(Register.Sensusradio.SystemState));
|
||||||
|
if (radioSystemState != 0x01 && radioSystemState != 0)
|
||||||
{
|
{
|
||||||
LogSuccessText(Resources.StrRadioAlreadyActive);
|
LogSuccessText(Resources.StrRadioAlreadyActive);
|
||||||
retVal = true;
|
retVal = true;
|
||||||
@@ -1589,6 +1603,96 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
return retVal;
|
return retVal;
|
||||||
}
|
}
|
||||||
|
|
||||||
|
/// <summary>
|
||||||
|
/// The pulse module interrupts and disturbs the IrDA communication. As quick fix the pulse module can be switched off,
|
||||||
|
/// as soon as a communication could be established. As the pulse output will only be switched on again, if a pulse
|
||||||
|
/// module is attached to the device, this pulse mode can be switched active instantaneously after deactivation.
|
||||||
|
/// </summary>
|
||||||
|
/// <remarks date="2023-Mar-07" author="Roland Drabesch/Thomas Wiedebusch">
|
||||||
|
/// - Initial.
|
||||||
|
/// </remarks>
|
||||||
|
private Boolean DeactivatePulseModule()
|
||||||
|
{
|
||||||
|
var retVal = false;
|
||||||
|
try
|
||||||
|
{
|
||||||
|
if (!_currentGenesis.IsLoggedOn)
|
||||||
|
_currentGenesis.ReLogin();
|
||||||
|
|
||||||
|
// create path and name for register setup reminder for this PcbId
|
||||||
|
_pathNameCordonelRegisterRestoreSettingsFile = Path.Combine(FwUpdateConfig.ReportedPath,
|
||||||
|
$"{_currentGenesis.PcbId}_" + FwUpdateConfig.RestoreSettingsFileName);
|
||||||
|
|
||||||
|
var pulseMode =
|
||||||
|
RegisterConverter.ConvertTo<Byte>(_currentGenesis.ReadRegister(Register.Metrologyasst.PulseMode));
|
||||||
|
// if pulse mode is already set to 0 (OFF) this could be initial setup or a indication of a crashed update
|
||||||
|
if (pulseMode == 0)
|
||||||
|
{
|
||||||
|
LogText(Resources.StrPulseModeInactive);
|
||||||
|
// check if a file exists with settings from a previous update
|
||||||
|
if (File.Exists(_pathNameCordonelRegisterRestoreSettingsFile))
|
||||||
|
{
|
||||||
|
var fileData = File.ReadAllText(_pathNameCordonelRegisterRestoreSettingsFile);
|
||||||
|
_pulseModeRegistersRestore = JsonConvert.DeserializeObject<Dictionary<String, Byte[]>>(fileData);
|
||||||
|
}
|
||||||
|
retVal = true;
|
||||||
|
}
|
||||||
|
|
||||||
|
//if retVal is true, the pulse mode is switched OFF, no further action is required
|
||||||
|
if (!retVal)
|
||||||
|
{
|
||||||
|
// safe the pulse setting
|
||||||
|
_pulseModeRegistersRestore.Add(Register.Metrologyasst.PulseMode, new[] { pulseMode });
|
||||||
|
// Create new file as for report only one version is allowed
|
||||||
|
var serializedData = JsonConvert.SerializeObject(_pulseModeRegistersRestore);
|
||||||
|
var asciiStream = Encoding.UTF8.GetBytes(serializedData);
|
||||||
|
File.WriteAllBytes(_pathNameCordonelRegisterRestoreSettingsFile, asciiStream);
|
||||||
|
|
||||||
|
// write pulse mode temporary to 0 (OFF) and wait for result
|
||||||
|
retVal = _currentGenesis.WriteRegister(Register.Metrologyasst.PulseMode, 0);
|
||||||
|
LogText(Resources.StrPulseModeTemporaryDeactivated);
|
||||||
|
}
|
||||||
|
}
|
||||||
|
catch (Exception )
|
||||||
|
{
|
||||||
|
retVal = false;
|
||||||
|
}
|
||||||
|
|
||||||
|
_currentGenesis.Logout();
|
||||||
|
return retVal;
|
||||||
|
}
|
||||||
|
/// <summary>
|
||||||
|
/// Restore all listed registers.
|
||||||
|
/// </summary>
|
||||||
|
/// <remarks date="2023-Mar-07" author="Roland Drabesch/Thomas Wiedebusch">
|
||||||
|
/// - Initial.
|
||||||
|
/// </remarks>
|
||||||
|
private Boolean RestoreRegisters()
|
||||||
|
{
|
||||||
|
var retVal = true;
|
||||||
|
try
|
||||||
|
{
|
||||||
|
if (!_currentGenesis.IsLoggedOn)
|
||||||
|
_currentGenesis.ReLogin();
|
||||||
|
|
||||||
|
foreach (var item in _pulseModeRegistersRestore)
|
||||||
|
{
|
||||||
|
retVal &= _currentGenesis.WriteRegister(item.Key, item.Value);
|
||||||
|
}
|
||||||
|
|
||||||
|
retVal &= _currentGenesis.WriteRegister(Register.Metrologyasst.StoreConfiguration, 1);
|
||||||
|
if (retVal && _pulseModeRegistersRestore.Any(x => x.Key == Register.Metrologyasst.PulseMode))
|
||||||
|
LogText(Resources.StrPulseModeRestored);
|
||||||
|
}
|
||||||
|
catch (Exception )
|
||||||
|
{
|
||||||
|
retVal = false;
|
||||||
|
}
|
||||||
|
|
||||||
|
_currentGenesis.Logout();
|
||||||
|
return retVal;
|
||||||
|
}
|
||||||
|
|
||||||
/// <summary>
|
/// <summary>
|
||||||
/// Store configurations with logging of success or failed.
|
/// Store configurations with logging of success or failed.
|
||||||
/// </summary>
|
/// </summary>
|
||||||
@@ -1601,7 +1705,7 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
return false;
|
return false;
|
||||||
_currentGenesis.ReLogin();
|
_currentGenesis.ReLogin();
|
||||||
Boolean retVal;
|
Boolean retVal;
|
||||||
if ( _currentGenesis.StoreAllConfigurations())
|
if (_currentGenesis.StoreAllConfigurations())
|
||||||
{
|
{
|
||||||
LogSuccessText(Resources.StrStoreConfigSuccess);
|
LogSuccessText(Resources.StrStoreConfigSuccess);
|
||||||
retVal = true;
|
retVal = true;
|
||||||
@@ -1635,7 +1739,7 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
// deactivate LED, not needed to get measurements during the update or on repeated start after system
|
// deactivate LED, not needed to get measurements during the update or on repeated start after system
|
||||||
// failure. This overwrites the settings in _meterFwUpdate.
|
// failure. This overwrites the settings in _meterFwUpdate.
|
||||||
_currentGenesis.WriteRegister(Register.Genesisflow.LedMode, new[] { (Byte)LedMode.Off });
|
_currentGenesis.WriteRegister(Register.Genesisflow.LedMode, new[] { (Byte)LedMode.Off });
|
||||||
_currentGenesis.WriteRegister(Register.Genesisflow.StoreConfiguration, 1);
|
_currentGenesis.WriteRegister(Register.Genesisflow.StoreConfiguration, 1);
|
||||||
LogText(Resources.StrDisplayReleased);
|
LogText(Resources.StrDisplayReleased);
|
||||||
_currentGenesis.Logout();
|
_currentGenesis.Logout();
|
||||||
}
|
}
|
||||||
@@ -2435,7 +2539,6 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
// try to login to check if meter is ready after reboot procedure
|
// try to login to check if meter is ready after reboot procedure
|
||||||
_currentGenesis.ReLogin();
|
_currentGenesis.ReLogin();
|
||||||
|
|
||||||
|
|
||||||
_processState = _currentGenesis.IsLoggedOn ? successExitState : errorExitState;
|
_processState = _currentGenesis.IsLoggedOn ? successExitState : errorExitState;
|
||||||
|
|
||||||
// change first the process state, otherwise the timer may switch the bar on again
|
// change first the process state, otherwise the timer may switch the bar on again
|
||||||
@@ -2654,6 +2757,49 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
SetOverallProgressDisplayOn(Resources.StrConnecting);
|
SetOverallProgressDisplayOn(Resources.StrConnecting);
|
||||||
}
|
}
|
||||||
|
|
||||||
|
/// <summary>
|
||||||
|
/// Common login and special setup procedure, as this is needed for login with password level 8
|
||||||
|
/// and for login with skeleton key:
|
||||||
|
/// - Initial login without register readout being able to quick switch off the pulse mode,
|
||||||
|
/// - Switch off the pulse mode on initial connection,
|
||||||
|
/// - Activate the radio,
|
||||||
|
/// - Release the display to normal operation,
|
||||||
|
/// - Store all configurations on initial connection.
|
||||||
|
/// </summary>
|
||||||
|
/// <param name="password">lvl8 or skeleton</param>
|
||||||
|
/// <param name="initialLogin">initial connection</param>
|
||||||
|
/// <returns>true if successfully executed</returns>
|
||||||
|
/// <remarks date="2023-Mar-07" author="Thomas Wiedebusch">
|
||||||
|
/// - Initial
|
||||||
|
/// </remarks>
|
||||||
|
private Boolean LoginAndSpecialSetupProcedure(String password, Boolean initialLogin)
|
||||||
|
{
|
||||||
|
// login without reading all registers and FW keeping the communication to a minimum to switch
|
||||||
|
// the pulse mode OFF before reading all installed apps, which will be unpredictable on activated
|
||||||
|
// pulse module
|
||||||
|
var retVal = _currentGenesis.Login(password, skipReadMeterFwAndAssignRegisters: initialLogin);
|
||||||
|
if (!retVal)
|
||||||
|
return false;
|
||||||
|
|
||||||
|
// switch the pulse module inactive
|
||||||
|
if (initialLogin)
|
||||||
|
DeactivatePulseModule();
|
||||||
|
|
||||||
|
// login with reading out all installed applications
|
||||||
|
retVal = _currentGenesis.Login(password);
|
||||||
|
|
||||||
|
if (_currentGenesis.RadioFrequencyMhz != null)
|
||||||
|
ActivateRadio();
|
||||||
|
|
||||||
|
// display to normal operation
|
||||||
|
ReleaseDisplay();
|
||||||
|
|
||||||
|
// safe all settings from RAM to FLASH to keep those for reboot
|
||||||
|
if (initialLogin)
|
||||||
|
StoreConfigurations();
|
||||||
|
|
||||||
|
return retVal;
|
||||||
|
}
|
||||||
/// <summary>
|
/// <summary>
|
||||||
/// Execution of connect to water-meter.
|
/// Execution of connect to water-meter.
|
||||||
/// </summary>
|
/// </summary>
|
||||||
@@ -2692,15 +2838,19 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
/// <remarks date="2023-Mar-01" author="Thomas Wiedebusch">
|
/// <remarks date="2023-Mar-01" author="Thomas Wiedebusch">
|
||||||
/// - "Release Display" before "Store Configuration".
|
/// - "Release Display" before "Store Configuration".
|
||||||
/// </remarks>
|
/// </remarks>
|
||||||
|
/// <remarks date="2023-Mar-07" author="Thomas Wiedebusch">
|
||||||
|
/// - "Deactivate Pulse Mode" at initial login to avoid interference of pulses to IrDA communication.
|
||||||
|
/// </remarks>
|
||||||
private Boolean ExecConnect()
|
private Boolean ExecConnect()
|
||||||
{
|
{
|
||||||
// logout if already logged in into meter
|
var initialLogin = false;
|
||||||
if (_currentGenesis.IsLoggedOn)
|
// read out the PCB ID from water-meter to open the password container of this device
|
||||||
_currentGenesis.Logout();
|
|
||||||
|
|
||||||
//read out the PCB ID from water-meter to open the password container of this device
|
|
||||||
if (string.IsNullOrEmpty(_currentGenesis.PcbId))
|
if (string.IsNullOrEmpty(_currentGenesis.PcbId))
|
||||||
|
{
|
||||||
|
// if the PcbId is unknown, it is an initial login
|
||||||
|
initialLogin = true;
|
||||||
_currentGenesis.GetPcbId();
|
_currentGenesis.GetPcbId();
|
||||||
|
}
|
||||||
|
|
||||||
// search the PCB ID and extract password for login
|
// search the PCB ID and extract password for login
|
||||||
String password = null;
|
String password = null;
|
||||||
@@ -2729,11 +2879,8 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
|
|
||||||
// this login may be time consuming on readout of application information
|
// this login may be time consuming on readout of application information
|
||||||
// first try to login with password Level 8, this is needed if the password file is installed
|
// first try to login with password Level 8, this is needed if the password file is installed
|
||||||
if (_currentGenesis.Login(password))
|
if (LoginAndSpecialSetupProcedure(password, initialLogin))
|
||||||
{
|
{
|
||||||
if (_currentGenesis.RadioFrequencyMhz != null) ActivateRadio();
|
|
||||||
ReleaseDisplay();
|
|
||||||
StoreConfigurations();
|
|
||||||
_passwordFileIsCorrupted = false;
|
_passwordFileIsCorrupted = false;
|
||||||
return true;
|
return true;
|
||||||
}
|
}
|
||||||
@@ -2752,11 +2899,9 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
// wait that long, otherwise the Cordonel locks for 2s, 4s, 8s, 16s and so on on every retry!
|
// wait that long, otherwise the Cordonel locks for 2s, 4s, 8s, 16s and so on on every retry!
|
||||||
Thread.Sleep(5000);
|
Thread.Sleep(5000);
|
||||||
|
|
||||||
if (_currentGenesis.Login(skeletonKey))
|
// use the skeleton key for login as the password file may not be installed or invalid
|
||||||
|
if (LoginAndSpecialSetupProcedure(skeletonKey, initialLogin))
|
||||||
{
|
{
|
||||||
if (_currentGenesis.RadioFrequencyMhz != null) ActivateRadio();
|
|
||||||
ReleaseDisplay();
|
|
||||||
StoreConfigurations();
|
|
||||||
return true;
|
return true;
|
||||||
}
|
}
|
||||||
|
|
||||||
@@ -2812,6 +2957,9 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
/// <remarks date="2021-Apr-20" author="Thomas Wiedebusch">
|
/// <remarks date="2021-Apr-20" author="Thomas Wiedebusch">
|
||||||
/// - Final login message produced to log password file validation.
|
/// - Final login message produced to log password file validation.
|
||||||
/// </remarks>
|
/// </remarks>
|
||||||
|
/// <remarks date="2023-Mar-07" author="Thomas Wiedebusch">
|
||||||
|
/// - Enable connect if error.
|
||||||
|
/// </remarks>
|
||||||
private void FinalConnect(Boolean success, IReadOnlyList<Object> exitProcessStateObjects)
|
private void FinalConnect(Boolean success, IReadOnlyList<Object> exitProcessStateObjects)
|
||||||
{
|
{
|
||||||
ObjectsToProcessStates(exitProcessStateObjects, out var successExitState, out var errorExitState,
|
ObjectsToProcessStates(exitProcessStateObjects, out var successExitState, out var errorExitState,
|
||||||
@@ -2833,6 +2981,7 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
_processState = errorExitState;
|
_processState = errorExitState;
|
||||||
// change first the process state, otherwise the timer may switch the bar on again
|
// change first the process state, otherwise the timer may switch the bar on again
|
||||||
SetOverallProgressDisplayOff();
|
SetOverallProgressDisplayOff();
|
||||||
|
SetDisableDownloadAndEnableConnect();
|
||||||
return;
|
return;
|
||||||
}
|
}
|
||||||
|
|
||||||
@@ -2847,15 +2996,15 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
// if authentication succeeded, the cordonel port detection must have succeeded in advance,
|
// if authentication succeeded, the cordonel port detection must have succeeded in advance,
|
||||||
// this information might get lost on Connect() without previous port scan.
|
// this information might get lost on Connect() without previous port scan.
|
||||||
InfoProcessSuccess(lblCordonelDetection, Resources.StrCordonelDetectSucceeded);
|
InfoProcessSuccess(lblCordonelDetection, Resources.StrCordonelDetectSucceeded);
|
||||||
InfoProcessSuccess(lblCordonelAuthentication, _finalLoginAfterUpdate
|
InfoProcessSuccess(lblCordonelAuthentication, _finalLoginAfterUpdate
|
||||||
? Resources.StrPasswordFileValid
|
? Resources.StrPasswordFileValid
|
||||||
: Resources.StrCordonelAuthenticationSucceeded);
|
: Resources.StrCordonelAuthenticationSucceeded);
|
||||||
|
|
||||||
// use here direct text assignment to avoid x or v before label
|
// use here direct text assignment to avoid x or v before label
|
||||||
UiInvoker.ControlInvoker(lblConnectPcb, ColorSuccess,
|
UiInvoker.ControlInvoker(lblConnectPcb, ColorSuccess,
|
||||||
Resources.StrPartPcbConnected + @" " + _currentGenesis.PcbId);
|
Resources.StrPartPcbConnected + @" " + _currentGenesis.PcbId);
|
||||||
UiInvoker.ControlInvoker(lblCoreRevision, ColorDefault,
|
UiInvoker.ControlInvoker(lblCoreRevision, ColorDefault,
|
||||||
Resources.StrCoreRevision + @" " +
|
Resources.StrCoreRevision + @" " +
|
||||||
$"{GenesisMeter.BuildFwVersionString(_currentGenesis.CoreRevision)}");
|
$"{GenesisMeter.BuildFwVersionString(_currentGenesis.CoreRevision)}");
|
||||||
// avoid report again on final login after update
|
// avoid report again on final login after update
|
||||||
if (!_finalLoginAfterUpdate && BuildReportFiles())
|
if (!_finalLoginAfterUpdate && BuildReportFiles())
|
||||||
@@ -3753,6 +3902,6 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw
|
|||||||
|
|
||||||
#endregion --------------------------------------- Language ---------------------------------------------------
|
#endregion --------------------------------------- Language ---------------------------------------------------
|
||||||
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|||||||
@@ -853,6 +853,33 @@ namespace Xylem.ServiceFwUpdate.Ui.ServiceFwUpdateSw.Properties {
|
|||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
/// <summary>
|
||||||
|
/// Looks up a localized string similar to Pulse mode is inactive..
|
||||||
|
/// </summary>
|
||||||
|
internal static string StrPulseModeInactive {
|
||||||
|
get {
|
||||||
|
return ResourceManager.GetString("StrPulseModeInactive", resourceCulture);
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
/// <summary>
|
||||||
|
/// Looks up a localized string similar to Original pulse mode restored..
|
||||||
|
/// </summary>
|
||||||
|
internal static string StrPulseModeRestored {
|
||||||
|
get {
|
||||||
|
return ResourceManager.GetString("StrPulseModeRestored", resourceCulture);
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
/// <summary>
|
||||||
|
/// Looks up a localized string similar to Pulse mode temporary deactivated..
|
||||||
|
/// </summary>
|
||||||
|
internal static string StrPulseModeTemporaryDeactivated {
|
||||||
|
get {
|
||||||
|
return ResourceManager.GetString("StrPulseModeTemporaryDeactivated", resourceCulture);
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
/// <summary>
|
/// <summary>
|
||||||
/// Looks up a localized string similar to Failed to activate the radio in customer mode!.
|
/// Looks up a localized string similar to Failed to activate the radio in customer mode!.
|
||||||
/// </summary>
|
/// </summary>
|
||||||
|
|||||||
@@ -529,4 +529,13 @@
|
|||||||
<data name="StrDisplayReleased" xml:space="preserve">
|
<data name="StrDisplayReleased" xml:space="preserve">
|
||||||
<value>Display freigegeben für Volumen- und Durchflußanzeige.</value>
|
<value>Display freigegeben für Volumen- und Durchflußanzeige.</value>
|
||||||
</data>
|
</data>
|
||||||
</root>
|
<data name="StrPulseModeInactive" xml:space="preserve">
|
||||||
|
<value>Pulsmodus ist ausgeschaltet.</value>
|
||||||
|
</data>
|
||||||
|
<data name="StrPulseModeRestored" xml:space="preserve">
|
||||||
|
<value>Orginal Pulsmodus wiederhergestellt.</value>
|
||||||
|
</data>
|
||||||
|
<data name="StrPulseModeTemporaryDeactivated" xml:space="preserve">
|
||||||
|
<value>Pulsmodus vorrübergehend ausgeschaltet.</value>
|
||||||
|
</data>
|
||||||
|
</root>
|
||||||
@@ -529,4 +529,13 @@
|
|||||||
<data name="StrDisplayReleased" xml:space="preserve">
|
<data name="StrDisplayReleased" xml:space="preserve">
|
||||||
<value>Display released to accumulator- and flow-display.</value>
|
<value>Display released to accumulator- and flow-display.</value>
|
||||||
</data>
|
</data>
|
||||||
|
<data name="StrPulseModeInactive" xml:space="preserve">
|
||||||
|
<value>Pulse mode is inactive.</value>
|
||||||
|
</data>
|
||||||
|
<data name="StrPulseModeRestored" xml:space="preserve">
|
||||||
|
<value>Original pulse mode restored.</value>
|
||||||
|
</data>
|
||||||
|
<data name="StrPulseModeTemporaryDeactivated" xml:space="preserve">
|
||||||
|
<value>Pulse mode temporary deactivated.</value>
|
||||||
|
</data>
|
||||||
</root>
|
</root>
|
||||||
Reference in New Issue
Block a user