GenesisStatus: - taken POWERMON_RemainingSeconds,

ProductionUiCordonel: - check EOL remaining lifetime from firmware POWERMON_RemainingSeconds
This commit is contained in:
Thomas Wiedebusch
2025-08-11 16:51:19 +02:00
parent 46e2ceca04
commit 82ae52eb3c
11 changed files with 92 additions and 54 deletions
@@ -18469,7 +18469,7 @@
},
"description": "",
"version": {
"first": 69,
"first": 72,
"last": 72
},
"statictype": "dynamic",
@@ -7,6 +7,16 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisStatus
/// </summary>
public class GenesisStatus
{
/// <summary>
/// Remaining lifetime for Cordonel in years based on FW calculation.
/// </summary>
public Double? FwCalculatedRemainingLifeTimeYears { get; set; }
/// <summary>
/// Remaining lifetime for Cordonel in seconds based on FW calculation.
/// </summary>
public UInt64? FwCalculatedRemainingLifeTime_s { get; set; }
/// <summary>
/// Remaining lifetime for Cordonel in years based on battery drainage.
/// </summary>
@@ -280,6 +280,9 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisStatus
/// <remarks date="2024-Nov-15" author="Thomas Wiedebusch">
/// - errorMsg.
/// </remarks>
/// <remarks date="2025-Aug-11" author="Thomas Wiedebusch">
/// - Readout FW based calculation of remaining lifetime in seconds.
/// </remarks>
public static Boolean BuildLifeTimeInformation(IGenesisMeter currentGenesis, GenesisStatus status, out String errorMsg)
{
Boolean retVal;
@@ -302,6 +305,13 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisStatus
status.InitialBatteryLoad_mAh = RegisterConverter.ByteArrayToValue<UInt32>(
currentGenesis.ReadRegister(Register.Powermon.BatteryInitialLoad));
var nullCheck = currentGenesis.ReadRegister(Register.Powermon.RemainingSeconds);
if (nullCheck == null)
status.FwCalculatedRemainingLifeTime_s = null;
else
status.FwCalculatedRemainingLifeTime_s =
RegisterConverter.ByteArrayToValue<UInt32>(nullCheck);
currentGenesis.Logout();
retVal = CalculateLifeTime(status);
@@ -337,6 +347,9 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisStatus
/// <remarks date="2025-Mar-25" author="Thomas Wiedebusch">
/// - Calculate storage months.
/// </remarks>
/// <remarks date="2025-Aug-11" author="Thomas Wiedebusch">
/// - Calculate FW based calculation of remaining lifetime in years.
/// </remarks>
public static Boolean CalculateLifeTime(GenesisStatus status)
{
// Mark as false if the basic inputs are missed
@@ -361,6 +374,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisStatus
var estimatedLifeTime_s = status.ExceededLifeTime_s / drainedBatteryLoad_rel;
var remainingLifetime_s = estimatedLifeTime_s - status.ExceededLifeTime_s;
status.RemainingLifeTimeYears = remainingLifetime_s * YEARS_PER_SECONDS;
status.FwCalculatedRemainingLifeTimeYears = status.FwCalculatedRemainingLifeTime_s * YEARS_PER_SECONDS;
// Calculate an alternative threshold for remaining battery load based on the quiescent current and a supplement
// for production purpose. Those values can be assigned in the Cordonel requirements.
@@ -94,6 +94,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.Registers
public static readonly String BatteryInitialLoad = "POWERMON_BatteryMilliAHrRating";
public static readonly String BatteryExceededSeconds = "POWERMON_TotalUsedSeconds";
public static readonly String StoreConfiguration = "POWERMON_StoreConfiguration";
public static readonly String RemainingSeconds = "POWERMON_RemainingSeconds";
}