diff --git a/Common/Hardware/WaterMeter/MagFlux/MagFluxCore/MagFluxMeter.cs b/Common/Hardware/WaterMeter/MagFlux/MagFluxCore/MagFluxMeter.cs
index 792844db..73fbe8c4 100644
--- a/Common/Hardware/WaterMeter/MagFlux/MagFluxCore/MagFluxMeter.cs
+++ b/Common/Hardware/WaterMeter/MagFlux/MagFluxCore/MagFluxMeter.cs
@@ -1098,6 +1098,19 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
return pcbId;
}
///
+ /// Get empty pipe control bits MagFlux
+ ///
+ public Boolean GetEmptyPipeControl()
+ {
+ var retVal = RequestProtocol.GetEmptyPipeControl(out var epd_cntl_bits);
+ if (retVal)
+ {
+ EpdControlBits = epd_cntl_bits;
+ }
+
+ return retVal;
+ }
+ ///
/// Write calibration values to MagFlux
///
public void WriteCalibration(List calibrationsCmPerH)
diff --git a/Common/Ui/MagFluxToolBox/FrmTest.cs b/Common/Ui/MagFluxToolBox/FrmTest.cs
index a0f044aa..ac6b0bd4 100644
--- a/Common/Ui/MagFluxToolBox/FrmTest.cs
+++ b/Common/Ui/MagFluxToolBox/FrmTest.cs
@@ -636,7 +636,20 @@ namespace Xylem.Common.Ui.MagFluxToolBox
private void cbxIgnoreEmptyPipeStatus_CheckedChanged(Object sender, EventArgs e)
{
var retVal = _magFluxMeter?.SetIgnoreFailOnEmptyPipeOnHealthy(cbxIgnoreEmptyPipeStatus.Checked);
- cbxIgnoreEmptyPipeStatus.ForeColor = retVal == null || (Boolean) retVal == false ? Color.Red : SystemColors.ControlText;
+ if (retVal != null && (Boolean)retVal)
+ {
+ cbxIgnoreEmptyPipeStatus.ForeColor = SystemColors.ControlText;
+ if (_magFluxMeter != null && _magFluxMeter.GetEmptyPipeControl())
+ {
+ cbxStatus10.Checked = (_magFluxMeter?.EpdControlBits & 0x01) == 0x01;
+ cbxStatus11.Checked = (_magFluxMeter?.EpdControlBits & 0x02) == 0x02;
+ cbxStatus12.Checked = (_magFluxMeter?.EpdControlBits & 0x04) == 0x04;
+ }
+ }
+ else
+ {
+ cbxIgnoreEmptyPipeStatus.ForeColor = Color.Red;
+ }
}
private void cbxSimulatedFlow_CheckedChanged(Object sender, EventArgs e)