This commit is contained in:
Stoyan Zlatev
2024-09-24 09:47:44 +02:00
14 changed files with 598 additions and 295 deletions
@@ -56,12 +56,6 @@ namespace XYLEM
/// <param name="baudRate">Like 9600 (default on RS485)</param>
/// <param name="parity">Like Parity.Even (default on RS485)</param>
/// <returns></returns>
Boolean Connect(string comport, UInt16 id, UInt32 baudRate, Parity parity);
/// <summary>
/// Close communication connection to Meter
/// </summary>
/// <returns>true on okay or false on error</returns>
Boolean CloseConnection();
Boolean Connect(string comport, UInt16 id, UInt32 baudRate, Parity parity);
}
}
@@ -1,11 +1,11 @@
using System.IO.Ports;
using System;
using System.IO.Ports;
using XYLEM.Device;
namespace XYLEM
{
public interface IMagFluxAPI
{
/// <summary>
/// Make communication connection to Meter
///
@@ -36,5 +36,12 @@ namespace XYLEM
/// <returns>Return a MagFlux device or "null" if failing connect</returns>
/// <exception cref="InvalidDataException"> if the configuration is not valid</exception>
IMagFluxRequestProtocol Connect(string comport, ushort id, uint baudRate, Parity parity, string log_path = null, RUN_TYPE runAs = RUN_TYPE.Normal);
/// <summary>
/// Close communication connection to all Meters and clean up for a fresh connection of all devices.
/// Note to continue, all devices needs initialized to be reconnected with Connect(...)
/// </summary>
/// <returns>true on okay or false on error</returns>
Boolean CloseConnections();
}
}
@@ -16,6 +16,20 @@ namespace XYLEM
/// <returns>true if yes</returns>
Boolean IsConnected();
/// <summary>
/// Close communication connection to Meter
/// </summary>
/// <returns>true on okay or false on error</returns>
Boolean CloseConnection();
/// <summary>
/// Try reconnect communication to a Meter that already had a communication connection
/// Note: will reuse already used communication settings and CloseConnection() is not already closed before call.
/// Used for reestablished communication to Meter when fail to respond during normal operation
/// </summary>
/// <returns>true on okay or false on error</returns>
Boolean Reconnect();
/// <summary>
/// Get current device Modbus ID / Device Address
/// </summary>
@@ -147,6 +161,22 @@ namespace XYLEM
/// <returns>true on okay or false on error</returns>
Boolean GetFlowRate_lps(out Single value_out);
/// <summary>
/// Average Electrode measurement used for Device calibration verification
/// </summary>
/// <param name="value_out"> Average Electrode [mV] </param>
/// <returns>true on okay or false on error</returns>
Boolean GetAverage_Electrode_mV(out Single value_out);
/// <summary>
/// Standard deviation electrode measurement used for Device calibration verification
/// Note: update will only happen after x seconds, depending on filter config in device
/// </summary>
/// <param name="value_out"> Average Electrode [mV] </param>
/// <returns>true on okay or false on error</returns>
Boolean GetStdDev_Electrode_mV(out Single value_out);
/// <summary>
/// !!! Warning make sure to turn off simulation, when calibration off sensor is done !!!
/// ----
@@ -89,20 +89,21 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore.Consts
public static String GetStateInfosOfStateMask(UInt32 stateMask)
{
var sb = new StringBuilder();
sb.Append("Device State:\n");
sb.Append($"Device State: 0x{stateMask:X4}");
// if state is okay return immediately
if (stateMask == (UInt32)State.Okay)
{
sb.Append(GetStateInfoOfState(State.Okay)).Append("\n");
sb.Append(GetStateInfoOfState(State.Okay));
return sb.ToString();
}
sb.Append(" => ");
// loop all states set in state mask
foreach (var state in _stateContainer.Where(state => state.State != State.Okay).Where(state =>
((UInt32)state.State & stateMask) == (UInt32)state.State))
{
sb.Append(state.Info).Append("\n");
sb.Append(state.Info).Append(" | ");
}
return sb.ToString();
@@ -37,6 +37,14 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
{
#region Variables and Properties
/// <summary>
/// Ident of request protocol
/// </summary>
private String RequestIdent
{
get;
set;
}
/// <summary>
/// Reminder for status bits
/// </summary>
@@ -51,6 +59,22 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
/// </summary>
private Boolean _enableRawDataLogging;
/// <summary>
/// Simulated flow activity
/// </summary>
public Boolean SimulatedFlowIsActive
{
get;
private set;
}
/// <summary>
/// Empty pipe ignore
/// </summary>
public Boolean IgnoreEmptyPipeDetection
{
get;
private set;
}
/// <summary>
/// to reduce the IrdA communication in test bench, preparation will be done once (when SkipPreparationForTestBench is true)
/// </summary>
@@ -67,7 +91,11 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
/// Quality watch mode can be used to decode intermediate records and check
/// for actual quality of the measurements.
/// </summary>
public Boolean QualityWatchMode;
public Boolean QualityWatchMode
{
get;
set;
}
/// <summary>
/// Represent FW version
@@ -123,6 +151,22 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
get; private set;
}
/// <summary>
/// Average of the electrode in milli Volts
/// </summary>
public Single AverageElectrode_mV
{
get; private set;
}
/// <summary>
/// Standard deviation of the electrode in milli Volts
/// </summary>
public Single StandardDeviationElectrode_mV
{
get; private set;
}
/// <summary>
/// Represents Empty Pipe Detection control bits
/// Bit0="EPD disabled", 1="Enabled w. Flags only", 2="EPD enabled full"
@@ -300,6 +344,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
private readonly CancellationTokenSource _keepSessionToken = new CancellationTokenSource();
private ILogger _logger;
//private ILogger _loggerRawData;
#endregion
@@ -407,7 +452,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
if (record.StatusBits != _lastStatusBits)
{
_lastStatusBits = record.StatusBits;
_logger.Info($"Slot:{Slot} - {StateDef.GetStateInfosOfStateMask(record.StatusBits)}");
_logger.Debug($"{RequestIdent} {StateDef.GetStateInfosOfStateMask(record.StatusBits)}");
}
}
@@ -491,7 +536,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
/// <inheritdoc />
public void Dispose()
{
_logger.Trace($"Slot:{Slot} - Start to dispose");
WriteLog("Start to dispose");
StreamingProtocol.OnRecordIsDecoded -= StreamingProtocol_ApplyDecodedRecord;
RequestProtocol.OnRecordIsDecoded -= RequestProtocol_ApplyDecodedRecord;
@@ -542,30 +587,30 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
RequestProtocol?.Dispose();
StreamingProtocol?.Dispose();
_logger.Trace($"Slot:{Slot} - Dispose is finished");
WriteLog("Dispose is finished");
}
/// <summary>
/// Ctor
/// </summary>
/// <param name="slot">Slot number for test-bench </param>
/// <param name="requestPort"><see cref="PortConfig" /> for request Port</param>
/// <param name="streamingPort"><see cref="PortConfig" /> for streaming Port</param>
/// <param name="ignoreCorruptedData">don´t send CRC error or telegrams with error flag to caller</param>
/// <param name="password">
/// If you have a password for highest access level you need, if you don't want to access the meter
/// (just read led record) than you can leave it null
/// </param>
/// <remarks date="2023-Apr-20" author="Thomas Wiedebusch">
/// - Initial
/// </remarks>
public MagFluxMeter(Int32 slot, PortConfig? requestPort, PortConfig? streamingPort,
Boolean ignoreCorruptedData = true, String password = null)
{
_logger = NLogHelper.CreateOrGetMultiLogger($"Slot:{slot}", "Slot", "Meter", "MeterBase", "MeterBase");
SetupMagFluxMeter(slot, requestPort, streamingPort, ignoreCorruptedData, password);
}
///// <summary>
///// Ctor
///// </summary>
///// <param name="slot">Slot number for test-bench </param>
///// <param name="requestPort"><see cref="PortConfig" /> for request Port</param>
///// <param name="streamingPort"><see cref="PortConfig" /> for streaming Port</param>
///// <param name="ignoreCorruptedData">don´t send CRC error or telegrams with error flag to caller</param>
///// <param name="password">
///// If you have a password for highest access level you need, if you don't want to access the meter
///// (just read led record) than you can leave it null
///// </param>
///// <remarks date="2023-Apr-20" author="Thomas Wiedebusch">
///// - Initial
///// </remarks>
//public MagFluxMeter(Int32 slot, PortConfig? requestPort, PortConfig? streamingPort,
// Boolean ignoreCorruptedData = true, String password = null)
//{
// _logger = NLogHelper.CreateOrGetMultiLogger($"Slot:{slot}", "Slot", "Meter", "MeterBase", "MeterBase");
// SetupMagFluxMeter(slot, requestPort, streamingPort, ignoreCorruptedData, password);
//}
#endregion
@@ -591,15 +636,15 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
{
if (requestPort.Value.Type == "Xylem.Common.Hardware.Interfaces.Ports.SerialPorts.UartSerialPort")
{
var requestIdent = $"Slot:{Slot}, Port:{requestPort.Value.PortName}, Protocol:Request, Type:UART -";
RequestIdent = $"Slot:{Slot}, Port:{requestPort.Value.PortName}, Protocol:Request, Type:UART -";
RequestProtocol = new RequestProtocol(requestIdent);
RequestProtocol = new RequestProtocol(RequestIdent);
TransmitProtocol = new UartTransmitProtocol(requestPort.Value.PortName);
//RequestProtocol.SetTransmitProtocol(TransmitProtocol);
// request port is needed to assign the port name from file, else it is not used
// as the IMagFluxRequestProtocol implements the port handling and communication
RequestPort = new UartSerialPort(requestIdent, requestPort.Value.GetSerialPort(),
RequestPort = new UartSerialPort(RequestIdent, requestPort.Value.GetSerialPort(),
TransmitProtocol.GetTransmitPortSettings());
}
}
@@ -608,7 +653,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
{
var ledTransmit = new LedTransmitProtocol(streamingPort.Value.PortName);
var streamingIdent = $"Slot:{Slot}, Port:{streamingPort.Value.PortName}, Protocol:LED";
var streamingIdent = $"Slot:{Slot}, Port:{streamingPort.Value.PortName}, Protocol:Streaming, Type:LED -";
StreamingPort = new LedSerialPort(streamingIdent, streamingPort.Value.GetSerialPort(),
ledTransmit.GetTransmitPortSettings());
@@ -617,7 +662,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
Configuration = new ProcessConfig(ProgramConfig.ConfigFileName);
SetLogger();
_logger.Debug($"Slot:{Slot} - Setup done");
WriteLog("Setup done");
}
/// <inheritdoc />
@@ -630,23 +675,23 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
{
if (RequestProtocol.Connect(RequestPort.GetPortName()))
{
_logger.Trace($"Slot:{Slot} - RequestPort and RequestProtocol linked");
WriteLog("RequestPort and RequestProtocol linked");
RequestProtocol.OnRecordIsDecoded += RequestProtocol_ApplyDecodedRecord;
RequestProtocol.CloseConnection();
}
else
{
_logger.Trace($"Slot:{Slot} - RequestPort Connection failed");
WriteLog("RequestPort Connection failed");
}
}
if (StreamingPort != null && StreamingPort.GetPortName() != BaseSerialPort.PortNotAssigned)
{
LinkPortToProtocol(StreamingPort, StreamingProtocol);
_logger.Trace($"Slot:{Slot} - StreamingPort and StreamingProtocol linked");
WriteLog("StreamingPort and StreamingProtocol linked");
StreamingProtocol.OnRecordIsDecoded += StreamingProtocol_ApplyDecodedRecord;
}
_logger.Debug($"Slot:{Slot} - Connected and communication started");
WriteLog("Connected and communication started");
}
/// <summary>
@@ -702,7 +747,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
private void RequestProtocol_AuthorizationGrant(Object sender, EventArgs e)
{
_logger.Debug($"Slot:{Slot} - Authorization succeeded");
WriteLog("Authorization succeeded");
}
public void SetupFromConfigFile(Int32 slot, Boolean ignoreCorruptedData = true)
@@ -727,7 +772,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
calibrationCmPerH.dutFlowRate = (Single)result.MeasuredDutFlowQmPerH;
calibrationsCmPerH.Add(calibrationCmPerH);
}
_logger.Debug($"Slot:{Slot} - Test bench calibration values received");
WriteLog("Test bench calibration values received");
WriteCalibration(calibrationsCmPerH);
ReadCalibration(out _);
@@ -791,7 +836,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
}
}
_logger.Debug($"Slot:{slot} - Configuration loaded");
WriteLog("Configuration loaded");
}
/// <inheritdoc />
@@ -859,9 +904,21 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
{
EpdControlBits = epd_cntl_bits;
}
RequestProtocol?.GetCalibrationPoints(out _);
StreamingProtocol?.SetDecodingMask(SensorSerialNo, uniqueId);
if (RequestProtocol.GetStdDev_Electrode_mV(out var u_mV))
{
StandardDeviationElectrode_mV = u_mV;
}
if (RequestProtocol.GetAverage_Electrode_mV(out u_mV))
{
AverageElectrode_mV = u_mV;
}
SimulatedFlowIsActive = RequestProtocol.IsSimulatedFlowActive();
IgnoreEmptyPipeDetection = RequestProtocol.GetIgnoreFailOnEmptyPipeOnHealthy();
RequestProtocol.GetCalibrationPoints(out _);
StreamingProtocol.SetDecodingMask(SensorSerialNo, uniqueId);
return IsLoggedOn;
}
@@ -874,7 +931,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
/// <inheritdoc />
public void InitMeasurement()
{
_logger.Info($"Slot:{Slot} - Init measurement");
WriteLog("Init measurement");
PreMeasurement();
}
@@ -904,7 +961,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
measurement.OnActionStateHasChanged += Measurement_ActionStateHasChanged;
}
_logger.Info($"Slot:{Slot} - Start measurement");
WriteLog("Start measurement");
ProcessStatus = ProcessState.MeasurementIsActive;
_listOfIMeasurement.ForEach(m => m.MeasurementState = MeasurementStates.IsWaitingForStartData);
@@ -914,7 +971,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
/// <inheritdoc />
public void StopMeasurement()
{
_logger.Info($"Slot:{Slot} - Stop measurement");
WriteLog("Stop measurement");
ProcessStatus = ProcessState.MeasurementIsDone;
_listOfIMeasurement.ForEach(m => m.MeasurementState = MeasurementStates.IsWaitingForEndData);
SyncStreamingBuffer(SyncMarkRecord.SyncEnd);
@@ -937,7 +994,6 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
}
/// <inheritdoc />
///
public List<MeasurementResults> GetAllMeasurementResults(Double? refVolume, Double? refTimeS, Boolean intermediateMeasurement = false,
Int32? channel = null, MeasurementDirection dir = MeasurementDirection.TakeBoth)
{
@@ -958,7 +1014,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
? mainMeasurement.GetIntermediateMeasurementResult(refVolume, refTimeS)
: mainMeasurement.GetFinalMeasurementResult(refVolume, refTimeS);
results.Add(mainResult);
_logger.Info($"Slot:{Slot}, Channel:{mainMeasurement.GetChannel()} - MeasuredTime({mainResult.DutTimeS}s), " +
_logger.Debug($"Slot:{Slot}, Channel:{mainMeasurement.GetChannel()} - MeasuredTime({mainResult.DutTimeS}s), " +
$"MeasuredVolume({mainResult.DutVolumeCm}Qm)");
foreach (var otherMeasurement in _listOfIMeasurement.Where(m => m.GetType() != typeof(MagFluxRecord)))
@@ -968,7 +1024,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
var otherResults = intermediateMeasurement
? otherMeasurement.GetIntermediateMeasurementResult(refVolume, refTimeS)
: otherMeasurement.GetFinalMeasurementResult(refVolume, refTimeS);
_logger.Info($"Slot:{Slot}, Channel:{otherMeasurement.GetChannel()} - ChannelTime({otherResults.DutTimeS}s), " +
_logger.Debug($"Slot:{Slot}, Channel:{otherMeasurement.GetChannel()} - ChannelTime({otherResults.DutTimeS}s), " +
$"ChannelVolume({otherResults.DutVolumeCm}Qm)");
results.Add(otherResults);
}
@@ -988,7 +1044,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
/// <inheritdoc />
public MeasurementStates GetMeasurementState(Int32? onlyChannelNr = null)
{
_logger.Trace($"Slot:{Slot} - Get measurement state");
WriteLog("Get measurement state");
if (!_listOfIMeasurement.Any())
{
return MeasurementStates.NotStarted;
@@ -1005,7 +1061,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
/// <inheritdoc />
public Boolean RequestIntermediateMeasurementState(Int32? onlyChannelNr = null)
{
_logger.Trace($"Slot:{Slot} - Get measurement state");
WriteLog("Get measurement state");
if (!_listOfIMeasurement.Any())
{
return false;
@@ -1048,13 +1104,25 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
return pcbId;
}
/// <summary>
/// Get empty pipe control bits MagFlux
/// </summary>
public Boolean GetEmptyPipeControl()
{
var retVal = RequestProtocol.GetEmptyPipeControl(out var epd_cntl_bits);
if (retVal)
{
EpdControlBits = epd_cntl_bits;
}
return retVal;
}
/// <summary>
/// Write calibration values to MagFlux
/// </summary>
public void WriteCalibration(List<Calibration> calibrationsCmPerH)
{
_logger.Info($"Slot:{Slot} - Write calibration values to MagFlux");
RequestProtocol?.SetCalibrationPoints(calibrationsCmPerH);
RequestProtocol?.CloseConnection();
//RequestProtocol?.CloseConnection();
}
/// <summary>
/// Read calibration values to MagFlux
@@ -1062,44 +1130,60 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
public void ReadCalibration(out List<Calibration> calibrationsCmPerH)
{
calibrationsCmPerH = null;
_logger.Info($"Slot:{Slot} - Read calibration values from MagFlux");
RequestProtocol?.GetCalibrationPoints(out calibrationsCmPerH);
RequestProtocol?.CloseConnection();
//RequestProtocol?.CloseConnection();
}
///// <summary>
///// Turn on/off fixed test flow output from MagFlux
///// Used for getting a fixed simulated flow from MagFlux
///// </summary>
///// <param name="testFlowOn"></param>
///// <returns>true on okay or false on error</returns>
//public Boolean SetSimulatedFlowActive(Boolean testFlowOn)
//{
// _logger.Info($"Slot:{Slot} - Set test flow");
// return RequestProtocol.SetSimulatedFlowActive(on);
//}
/// <summary>
/// Average Electrode measurement used for Device calibration verification
/// </summary>
/// <param name="u_mV"> Average Electrode [mV] </param>
/// <returns>true on okay or false on error</returns>
public Boolean GetAverage_Electrode_mV(out Single u_mV)
{
u_mV = 0;
var retVal = RequestProtocol.GetAverage_Electrode_mV(out u_mV);
AverageElectrode_mV = u_mV;
return retVal;
}
///// <summary>
///// Is the fixed test flow active
///// Used for getting a fixed simulated flow from MagFlux
///// </summary>
///// <returns>true if ON</returns>
//public Boolean IsSimulatedFlowActive()
//{
// _logger.Info($"Slot:{Slot} - Get test flow setting");
// return RequestProtocol.IsSimulatedFlowActive();
//};
/// <summary>
/// Standard deviation electrode measurement used for Device calibration verification
/// Note: update will only happen after x seconds, depending on filter config in device
/// </summary>
/// <param name="u_mV"> Average Electrode [mV] </param>
/// <returns>true on okay or false on error</returns>
public Boolean GetStdDev_Electrode_mV(out Single u_mV)
{
u_mV = 0;
var retVal = RequestProtocol.GetStdDev_Electrode_mV(out u_mV);
StandardDeviationElectrode_mV = u_mV;
return retVal;
}
/// <summary>
/// Ignore Empty pipe flag on Healthy, because it is not yet working correct
/// Note: Not 100% secure all test is working during empty pipe, metrology board firmware may not allow running during detection of empty pipe
/// </summary>
/// <param name="ignoreEmptyPipeStatus"></param>
/// <returns>true on okay or false on error</returns>
public Boolean SetIgnoreFailOnEmptyPipeOnHealthy(Boolean ignoreEmptyPipeStatus)
{
var retVal = RequestProtocol.SetIgnoreFailOnEmptyPipeOnHealthy(ignoreEmptyPipeStatus);
if (retVal)
IgnoreEmptyPipeDetection = ignoreEmptyPipeStatus;
return retVal;
}
/// <summary>
/// Set PCB settings and PCB calibrations to default.
/// </summary>
public Boolean SetPCBToDemoDefaults()
{
_logger.Info($"Slot:{Slot} - Set PCB settings and PCB calibrations to default");
if (RequestProtocol == null)
return false;
var retVal = RequestProtocol.SetPCBToDemoDefaults();
RequestProtocol?.CloseConnection();
//RequestProtocol?.CloseConnection();
return retVal;
}
@@ -1108,11 +1192,10 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
/// </summary>
public Boolean SetMeterSizeMm(UInt16 meterSize_mm)
{
_logger.Info($"Slot:{Slot} - Set meter size in mm");
if (RequestProtocol == null)
return false;
var retVal = RequestProtocol.SetMeterSizeMm(meterSize_mm);
RequestProtocol?.CloseConnection();
//RequestProtocol?.CloseConnection();
return retVal;
}
@@ -1121,23 +1204,21 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
/// </summary>
public Boolean SetSensorSerialNo(UInt32 sensorSerialNo)
{
_logger.Info($"Slot:{Slot} - Set sensor serial no.");
if (RequestProtocol == null)
return false;
var retVal = RequestProtocol.SetSensorSerialNo(sensorSerialNo);
RequestProtocol?.CloseConnection();
//RequestProtocol?.CloseConnection();
return retVal;
}
/// <inheritdoc />
public void InitCalibration()
{
_logger.Info($"Slot:{Slot} - Init calibration and set calibration values of all channels to default");
if (RequestProtocol == null)
return;
if (RequestProtocol.PrepareDeviceForCalibration())
PreMeasurement();
RequestProtocol?.CloseConnection();
//RequestProtocol?.CloseConnection();
}
/// <inheritdoc />
@@ -1150,7 +1231,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
public void StopCalibration()
{
StopMeasurement();
RequestProtocol?.CloseConnection();
//RequestProtocol?.CloseConnection();
}
/// <inheritdoc />
@@ -1193,7 +1274,13 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
/// <inheritdoc />
public void WriteLog(String text)
{
_logger.Info($"Slot:{Slot} - {text}");
_logger.Trace($"Slot:{Slot} - {text}");
}
/// <inheritdoc />
public void LogRawData(Boolean on)
{
_enableRawDataLogging = on;
//if (_enableRawDataLogging)
//{
// if (_loggerRawData == null)
@@ -1202,14 +1289,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
// StreamingPort.GetPortName(), "", "LedRawData", "TargetLedRawDataBase", "LedRawDataBase");
// }
// _loggerRawData.Info($"{text}");
//}
}
/// <inheritdoc />
public void LogRawData(Boolean on)
{
_enableRawDataLogging = on;
if (StreamingPort is LedSerialPort port)
{
port.RecordStreamingRawData = _enableRawDataLogging;
@@ -1297,24 +1377,24 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.MagFluxCore
((LedSerialPort)StreamingPort).RefreshLogger();
if (!string.IsNullOrEmpty(SerialNumber) && CurrentActionText.Contains("PG"))
{
//if (!string.IsNullOrEmpty(SerialNumber) && CurrentActionText.Contains("PG"))
//{
//var pathMain = NLogHelper.GetPath(_logger);
//var pathRaw = NLogHelper.GetPath(((LedSerialPort)StreamingPort).GetRawLogger());
// //var pathMain = NLogHelper.GetPath(_logger);
// //var pathRaw = NLogHelper.GetPath(((LedSerialPort)StreamingPort).GetRawLogger());
//var basePath = Path.GetDirectoryName(pathMain);
// //var basePath = Path.GetDirectoryName(pathMain);
//var testRunString = CurrentActionText.Replace("PG", "");
//var lastChat = pathMain.LastIndexOf('\\');
//pathMain = pathMain.Substring(lastChat + 1);
//pathRaw = Path.GetFileName(pathRaw);
// //var testRunString = CurrentActionText.Replace("PG", "");
// //var lastChat = pathMain.LastIndexOf('\\');
// //pathMain = pathMain.Substring(lastChat + 1);
// //pathRaw = Path.GetFileName(pathRaw);
//var tmpUrl = $"http://10.49.40.25/MeterProcessState/api/TestBench/SetMeterLogPathInfo?SerialNumber={SerialNumber}&TestRunId={testRunString}&BasePath={basePath}&MainLogName={pathMain}&LEDName={pathRaw}";
//_logger.Debug($"Request Url: { tmpUrl}");
////ToDO: Update to service URl
//LocalWebRequest.GetRequest(tmpUrl);
}
// //var tmpUrl = $"http://10.49.40.25/MeterProcessState/api/TestBench/SetMeterLogPathInfo?SerialNumber={SerialNumber}&TestRunId={testRunString}&BasePath={basePath}&MainLogName={pathMain}&LEDName={pathRaw}";
// //_logger.Debug($"Request Url: { tmpUrl}");
// ////ToDO: Update to service URl
// //LocalWebRequest.GetRequest(tmpUrl);
//}
}
}
}
@@ -18,7 +18,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
public class RequestProtocol : BaseProtocol
{
private readonly String _ident;
private readonly ILogger _logger;
private readonly ILogger _logger;
private IMagFluxRequestProtocol _magFluxRequestProtocol;
private IMagFluxAPI _magFluxApi;
@@ -34,7 +34,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
_ident = ident;
_magFluxApi = new MagFluxAPI();
_calibPointsCmPerH = new List<Calibration>();
_logger = NLogHelper.CreateOrGetMultiLogger(_ident, "", "RequestProtocol", "MeterBase",
_logger = NLogHelper.CreateOrGetMultiLogger(_ident, "", "RequestProtocol", "MeterBase",
"MeterBase");
}
@@ -74,24 +74,41 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
/// <remarks date="2024-Aug-12" author="T.Wiedebusch">
/// - MagFluxApi
/// </remarks>
/// <remarks date="2024-Sep-20" author="T.Wiedebusch">
/// - Avoid re-opening if connection is already done
/// </remarks>
public Boolean Connect(String portName)
{
if (_magFluxApi == null) return false;
if (_magFluxApi == null)
return false;
if (_magFluxRequestProtocol != null && _magFluxRequestProtocol.IsConnected())
{
_logger.Info($"{_ident} Connection already established to {portName}");
return true;
}
_magFluxRequestProtocol = _magFluxApi.Connect(portName);
if (_magFluxRequestProtocol == null)
{
_logger.Debug($"{_ident} Connection to {portName} failed! Object reference returned null");
_logger.Error($"{_ident} Connection to {portName} failed! Object reference returned null");
return false;
}
Thread.Sleep(100);
var retVal = _magFluxRequestProtocol.IsConnected();
_logger.Debug(retVal ? $"{_ident} Connection established to {portName}" :
$"{_ident} Connection to {portName} failed!");
if (retVal)
{
_logger.Info($"{_ident} New connection established to {portName}");
}
else
{
_logger.Error($"{_ident} Connection to {portName} failed!");
}
return retVal;
}
public String GetComCounters()
public String GetComCounters()
{
throw new NotImplementedException();
}
@@ -107,10 +124,13 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
/// </remarks>
public Boolean SetLogLocation(String path, String fileName)
{
if (_magFluxRequestProtocol == null) return false;
if (_magFluxRequestProtocol == null)
return false;
var retVal = _magFluxRequestProtocol.SetLogLocation(path, fileName);
if (string.IsNullOrEmpty(fileName)) fileName = "?";
_logger.Debug(retVal ? $"{_ident} Logging set to: {path}\\{fileName}" :
if (string.IsNullOrEmpty(fileName))
fileName = "?";
_logger.Debug(retVal ?
$"{_ident} Logging set to: {path}\\{fileName}" :
$"{_ident} Logging path setup failed!");
return retVal;
}
@@ -119,7 +139,7 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
{
throw new NotImplementedException();
}
/// <summary>
/// Wrapper to set experimental boards to defaults regarding board serial number
/// and board calibration values
@@ -130,78 +150,85 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
/// </remarks>
public Boolean SetPCBToDemoDefaults()
{
if (_magFluxRequestProtocol == null) return false;
if (_magFluxRequestProtocol == null)
return false;
var retVal = _magFluxRequestProtocol.SetPCBToDemoDefaults();
_logger.Debug(retVal ? $"{_ident} Successfully set PCB settings and PCB calibrations to default" :
_logger.Debug(retVal ?
$"{_ident} Successfully set PCB settings and PCB calibrations to default" :
$"{_ident} PCB settings and PCB calibrations setup to default failed!");
return retVal;
}
///// <summary>
///// Wrapper to get the simulated flow setting
///// </summary>
///// <returns></returns>
///// <remarks date="2024-Aug-23" author="T.Wiedebusch">
///// - Initial
///// </remarks>
//public Boolean GetSimulatedFlowOn()
//{
// if (_magFluxRequestProtocol == null) return false;
// var retVal = _magFluxRequestProtocol.IsSimulatedFlowActive();
// _logger.Debug(retVal ? $"{_ident} Simulated flow active read back returns: true" :
// $"{_ident} Read back simulated flow status failed!");
// return retVal;
//}
/// <summary>
/// Wrapper to get the simulated flow setting
/// </summary>
/// <returns></returns>
/// <remarks date="2024-Aug-23" author="T.Wiedebusch">
/// - Initial
/// </remarks>
public Boolean IsSimulatedFlowActive()
{
if (_magFluxRequestProtocol == null)
return false;
var retVal = _magFluxRequestProtocol.IsSimulatedFlowActive();
_logger.Debug($"{_ident} Simulated flow active read back returns: {retVal}");
return retVal;
}
///// <summary>
///// Wrapper to set the simulated flow setting
///// </summary>
///// <param name="on">true to ignore state</param>
///// <returns></returns>
///// <remarks date="2024-Aug-23" author="T.Wiedebusch">
///// - Initial
///// </remarks>
//public Boolean SetSimulatedFlowActive(Boolean on)
//{
// if (_magFluxRequestProtocol == null) return false;
// var retVal = _magFluxRequestProtocol.SetSimulatedFlowActive(on);
// _logger.Debug(retVal ? $"{_ident} Simulated flow active set to: {on}" :
// $"{_ident} Simulated flow active setup failed!");
// return retVal;
//}
/// <summary>
/// Wrapper to set the simulated flow setting
/// </summary>
/// <param name="on">true to ignore state</param>
/// <returns></returns>
/// <remarks date="2024-Aug-23" author="T.Wiedebusch">
/// - Initial
/// </remarks>
public Boolean SetSimulatedFlowActive(Boolean on)
{
if (_magFluxRequestProtocol == null)
return false;
var retVal = _magFluxRequestProtocol.SetSimulatedFlowActive(on);
_logger.Debug(retVal ?
$"{_ident} Simulated flow active set to: {on}" :
$"{_ident} Simulated flow active setup failed!");
return retVal;
}
///// <summary>
///// Wrapper to get the ignore empty pipe mode status
///// </summary>
///// <returns></returns>
///// <remarks date="2024-Aug-23" author="T.Wiedebusch">
///// - Initial
///// </remarks>
//public Boolean GetIgnoreEmptyPipeStatus()
//{
// if (_magFluxRequestProtocol == null) return false;
// var retVal = _magFluxRequestProtocol.IgnoreFailOnEmptyPipeOnHealthy();
// _logger.Debug(retVal ? $"{_ident} Ignore empty pipe status read back returns: {retVal}" :
// $"{_ident} Read back empty pipe status failed!");
// return retVal;
//}
/// <summary>
/// Wrapper to get the ignore empty pipe mode status
/// </summary>
/// <returns></returns>
/// <remarks date="2024-Aug-23" author="T.Wiedebusch">
/// - Initial
/// </remarks>
public Boolean GetIgnoreFailOnEmptyPipeOnHealthy()
{
if (_magFluxRequestProtocol == null)
return false;
var retVal = _magFluxRequestProtocol.GetIgnoreFailOnEmptyPipeOnHealthy();
_logger.Debug($"{_ident} Ignore empty pipe status read back returns: {retVal}");
return retVal;
}
///// <summary>
///// Wrapper to set the ignore empty pipe mode
///// </summary>
///// <param name="on">true to ignore state</param>
///// <returns></returns>
///// <remarks date="2024-Aug-23" author="T.Wiedebusch">
///// - Initial
///// </remarks>
//public Boolean SetIgnoreEmptyPipeStatus(Boolean on)
//{
// if (_magFluxRequestProtocol == null) return false;
// var retVal = _magFluxRequestProtocol.IgnoreFailOnEmptyPipeOnHealthy(on);
// _logger.Debug(retVal ? $"{_ident} Ignore empty pipe status adjusted to: {on}" :
// $"{_ident} Setup empty pipe status request failed!");
// return retVal;
//}
/// <summary>
/// Wrapper to set the ignore empty pipe mode
/// </summary>
/// <param name="on">true to ignore state</param>
/// <returns></returns>
/// <remarks date="2024-Aug-23" author="T.Wiedebusch">
/// - Initial
/// </remarks>
public Boolean SetIgnoreFailOnEmptyPipeOnHealthy(Boolean on)
{
if (_magFluxRequestProtocol == null)
return false;
_magFluxRequestProtocol.SetIgnoreFailOnEmptyPipeOnHealthy(on);
var retVal = _magFluxRequestProtocol.GetIgnoreFailOnEmptyPipeOnHealthy();
_logger.Debug(retVal == on ?
$"{_ident} Ignore empty pipe status adjusted to: {on}" :
$"{_ident} Ignore empty pipe status setup failed!");
return retVal == on;
}
/// <summary>
/// Wrapper to get the empty pipe bits
@@ -214,13 +241,54 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
public Boolean GetEmptyPipeControl(out Int32 epd_cntl_bits)
{
epd_cntl_bits = 0;
if (_magFluxRequestProtocol == null) return false;
if (_magFluxRequestProtocol == null)
return false;
var retVal = _magFluxRequestProtocol.GetEmptyPipeControl(out epd_cntl_bits);
_logger.Debug(retVal ? $"{_ident} Empty pipe control bits: 0x{epd_cntl_bits:X1}" :
_logger.Debug(retVal ?
$"{_ident} Empty pipe control bits: 0x{epd_cntl_bits:X4}" :
$"{_ident} Empty pipe control bits request failed!");
return retVal;
}
/// <summary>
/// Wrapper to get the standard deviation value of the electrode in milli Volts
/// </summary>
/// <param name="u_mV"></param>
/// <returns></returns>
/// <remarks date="2024-Sep-19" author="T.Wiedebusch">
/// - Initial
/// </remarks>
public Boolean GetStdDev_Electrode_mV(out Single u_mV)
{
u_mV = 0;
if (_magFluxRequestProtocol == null)
return false;
var retVal = _magFluxRequestProtocol.GetStdDev_Electrode_mV(out u_mV);
_logger.Debug(retVal ?
$"{_ident} Standard deviation of electrode: {u_mV:F6} mV" :
$"{_ident} Standard deviation of electrode request failed!");
return retVal;
}
/// <summary>
/// Wrapper to get the standard deviation value of the electrode in milli Volts
/// </summary>
/// <param name="u_mV"></param>
/// <returns></returns>
/// <remarks date="2024-Sep-19" author="T.Wiedebusch">
/// - Initial
/// </remarks>
public Boolean GetAverage_Electrode_mV(out Single u_mV)
{
u_mV = 0;
if (_magFluxRequestProtocol == null)
return false;
var retVal = _magFluxRequestProtocol.GetAverage_Electrode_mV(out u_mV);
_logger.Debug(retVal ?
$"{_ident} Average of electrode: {u_mV:F6} mV" :
$"{_ident} Average of electrode request failed!");
return retVal;
}
/// <summary>
/// Wrapper to get the board calibration value
/// </summary>
@@ -232,9 +300,11 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
public Boolean GetElectrodeBoardCorrectionFactor(out Single value_out)
{
value_out = 0f;
if (_magFluxRequestProtocol == null) return false;
if (_magFluxRequestProtocol == null)
return false;
var retVal = _magFluxRequestProtocol.GetElectrodeBoardCorrectionFactor(out value_out);
_logger.Debug(retVal ? $"{_ident} Board calibration: {value_out:F4}" :
_logger.Debug(retVal ?
$"{_ident} Board calibration: {value_out:F4}" :
$"{_ident} SensorSerialNo request failed!");
return retVal;
}
@@ -250,9 +320,11 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
public Boolean GetSensorSerialNo(out String sensorSerialNo)
{
sensorSerialNo = "?";
if (_magFluxRequestProtocol == null) return false;
if (_magFluxRequestProtocol == null)
return false;
var retVal = _magFluxRequestProtocol.GetSensorSerialNo(out sensorSerialNo);
_logger.Debug(retVal ? $"{_ident} SensorSerialNo: {sensorSerialNo}" :
_logger.Debug(retVal ?
$"{_ident} SensorSerialNo: {sensorSerialNo}" :
$"{_ident} SensorSerialNo request failed!");
return retVal;
}
@@ -268,9 +340,11 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
public Boolean GetPcbId(out String pcbId)
{
pcbId = "?";
if (_magFluxRequestProtocol == null) return false;
if (_magFluxRequestProtocol == null)
return false;
var retVal = _magFluxRequestProtocol.GetBoardSerialNo(out pcbId);
_logger.Debug(retVal ? $"{_ident} PcbId: {pcbId}" :
_logger.Debug(retVal ?
$"{_ident} PcbId: {pcbId}" :
$"{_ident} PcbId request failed!");
return retVal;
}
@@ -285,9 +359,11 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
/// </remarks>
public Boolean SetSensorSerialNo(UInt32 sensorSerialNo)
{
if (_magFluxRequestProtocol == null) return false;
if (_magFluxRequestProtocol == null)
return false;
var retVal = _magFluxRequestProtocol.SetSensorSerialNo(sensorSerialNo);
_logger.Debug(retVal ? $"{_ident} Set SensorSerialNo: {sensorSerialNo}" :
_logger.Debug(retVal ?
$"{_ident} Set SensorSerialNo: {sensorSerialNo}" :
$"{_ident} Set SensorSerialNo request failed!");
return retVal;
}
@@ -303,9 +379,11 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
public Boolean GetUniqueId(out String pcbId)
{
pcbId = "?";
if (_magFluxRequestProtocol == null) return false;
if (_magFluxRequestProtocol == null)
return false;
var retVal = _magFluxRequestProtocol.GetUniqueId(out pcbId);
_logger.Debug(retVal ? $"{_ident} UniqueId: {pcbId}" :
_logger.Debug(retVal ?
$"{_ident} UniqueId: {pcbId}" :
$"{_ident} UniqueId request failed!");
return retVal;
}
@@ -321,9 +399,11 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
public Boolean GetFirmwareVersion(out String fwVersion)
{
fwVersion = "?";
if (_magFluxRequestProtocol == null) return false;
if (_magFluxRequestProtocol == null)
return false;
var retVal = _magFluxRequestProtocol.GetFirmwareVersion(out fwVersion);
_logger.Debug(retVal ? $"{_ident} FW Version: {fwVersion}" :
_logger.Debug(retVal ?
$"{_ident} FW Version: {fwVersion}" :
$"{_ident} FW Version request failed!");
return retVal;
}
@@ -339,13 +419,15 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
public Boolean GetFwBuildDate(out String fwBuildDate)
{
fwBuildDate = "?";
if (_magFluxRequestProtocol == null) return false;
if (_magFluxRequestProtocol == null)
return false;
var retVal = _magFluxRequestProtocol.GetFwBuildDate(out fwBuildDate);
_logger.Debug(retVal ? $"{_ident} FW Build Date: {fwBuildDate}" :
_logger.Debug(retVal ?
$"{_ident} FW Build Date: {fwBuildDate}" :
$"{_ident} FW Build Date request failed!");
return retVal;
}
/// <summary>
/// Wrapper to get FW GIT hash of MagFlux
/// </summary>
@@ -357,9 +439,11 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
public Boolean GetFwGitHash(out String fwGitHash)
{
fwGitHash = "?";
if (_magFluxRequestProtocol == null) return false;
if (_magFluxRequestProtocol == null)
return false;
var retVal = _magFluxRequestProtocol.GetFwGitHash(out fwGitHash);
_logger.Debug(retVal ? $"{_ident} FW GIT Hash: {fwGitHash}" :
_logger.Debug(retVal ?
$"{_ident} FW GIT Hash: {fwGitHash}" :
$"{_ident} FW GIT Hash request failed!");
return retVal;
}
@@ -375,9 +459,11 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
public Boolean GetApiRegisterVersion(out String apiRegisterVersion)
{
apiRegisterVersion = "?";
if (_magFluxRequestProtocol == null) return false;
if (_magFluxRequestProtocol == null)
return false;
var retVal = _magFluxRequestProtocol.GetAPIRegisterVersion(out apiRegisterVersion);
_logger.Debug(retVal ? $"{_ident} MagFlux API Register Version: {apiRegisterVersion}" :
_logger.Debug(retVal ?
$"{_ident} MagFlux API Register Version: {apiRegisterVersion}" :
$"{_ident} MagFlux API Register Version request failed!");
return retVal;
}
@@ -398,9 +484,11 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
public Boolean GetMeterSizeMm(out Int32 meterSize)
{
meterSize = 0;
if (_magFluxRequestProtocol == null) return false;
if (_magFluxRequestProtocol == null)
return false;
var retVal = _magFluxRequestProtocol.GetDn_mm(out meterSize);
_logger.Debug(retVal ? $"{_ident} MeterSize DN: {meterSize}" :
_logger.Debug(retVal ?
$"{_ident} MeterSize DN: {meterSize}" :
$"{_ident} MeterSize request failed!");
return retVal;
}
@@ -415,9 +503,11 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
/// </remarks>
public Boolean SetMeterSizeMm(UInt16 meterSize)
{
if (_magFluxRequestProtocol == null) return false;
if (_magFluxRequestProtocol == null)
return false;
var retVal = _magFluxRequestProtocol.SetDn_mm(meterSize);
_logger.Debug(retVal ? $"{_ident} Set MeterSize DN: {meterSize}" :
_logger.Debug(retVal ?
$"{_ident} Set MeterSize DN: {meterSize}" :
$"{_ident} Set MeterSize failed!");
return retVal;
}
@@ -434,18 +524,22 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
public Boolean PrepareDeviceForCalibration()
{
if (_magFluxRequestProtocol == null) return false;
if (_magFluxRequestProtocol == null)
return false;
var retVal = _magFluxRequestProtocol.PrepareDeviceForCalibration();
_logger.Debug(retVal ? $"{_ident} MagFlux successfully prepared for calibration" :
_logger.Debug(retVal ?
$"{_ident} MagFlux successfully prepared for calibration" :
$"{_ident} MagFlux preparation for calibration failed!");
return retVal;
}
public Boolean AbortDeviceForCalibration()
{
if (_magFluxRequestProtocol == null) return false;
if (_magFluxRequestProtocol == null)
return false;
var retVal = _magFluxRequestProtocol.AbortDeviceForCalibration();
_logger.Debug(retVal ? $"{_ident} MagFlux calibration successfully aborted" :
_logger.Debug(retVal ?
$"{_ident} MagFlux calibration successfully aborted" :
$"{_ident} MagFlux abortion of calibration failed!");
return retVal;
}
@@ -466,15 +560,17 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
public Boolean GetCalibrationPoints(out List<Calibration> calibPointsCmPerH)
{
calibPointsCmPerH = new List<Calibration>();
if (_magFluxRequestProtocol == null) return false;
if (_magFluxRequestProtocol == null)
return false;
var retVal = _magFluxRequestProtocol.GetCalibrationPoints(out var calibrations);
_logger.Debug(retVal ? $"{_ident} MagFlux calibration successfully read:\n{calibrations}" :
_logger.Debug(retVal ?
$"{_ident} MagFlux calibration successfully read:\n{calibrations}" :
$"{_ident} MagFlux calibration read failed!");
if (!retVal)
return false;
// extract the single calibration points from container as ref and DUT in liters per second
var calibPoints = calibrations?.calibrations?.ToList();
if (calibPoints == null)
@@ -512,7 +608,8 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
/// </remarks>
public Boolean SetCalibrationPoints(List<Calibration> calibPointsCmPerH)
{
if (_magFluxRequestProtocol == null || calibPointsCmPerH == null) return false;
if (_magFluxRequestProtocol == null || calibPointsCmPerH == null)
return false;
// remove zeros as this are possibly empty (unused) fields
var removedZeros = calibPointsCmPerH.Where(x => x.dutFlowRate != 0 || x.refFlowRate != 0);
@@ -542,7 +639,8 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
}
var cbs = new CalibrationPoints(calibPoints, calibPoints.Count);
var retVal = _magFluxRequestProtocol.SetCalibrationPoints(cbs);
_logger.Debug(retVal ? $"{_ident} MagFlux calibration successfully set:\n{cbs}" :
_logger.Debug(retVal ?
$"{_ident} MagFlux calibration successfully set:\n{cbs}" :
$"{_ident} MagFlux calibration setup failed!");
return retVal;
}
@@ -560,12 +658,14 @@ namespace Xylem.Common.Hardware.WaterMeter.MagFlux.Protocols.RequestProtocol
/// </remarks>
public Boolean CloseConnection()
{
if (_magFluxRequestProtocol == null) return false;
if (_magFluxRequestProtocol == null)
return false;
MagFluxAPI.CloseAllConnections();
Thread.Sleep(100);
var retVal = _magFluxRequestProtocol.IsConnected();
_logger.Debug(!retVal ? $"{_ident} Connection is closed" :
_logger.Info(!retVal ?
$"{_ident} Connection is closed" :
$"{_ident} Close connection request failed!");
return retVal;
}
@@ -1 +1 @@
89102b0142e574de38a9f47d370f3334e5e6c268
8fbe991b217e7692af4817ad205b768685aa5a72