IGenesisMeter, new GenesisStatus

This commit is contained in:
Thomas Wiedebusch
2025-03-18 14:37:21 +01:00
parent e6fc5fc792
commit 277944edb3
110 changed files with 87131 additions and 903 deletions
+1
View File
@@ -55,6 +55,7 @@
<s:Boolean x:Key="/Default/UserDictionary/Words/=PCBID/@EntryIndexedValue">True</s:Boolean>
<s:Boolean x:Key="/Default/UserDictionary/Words/=perc/@EntryIndexedValue">True</s:Boolean>
<s:Boolean x:Key="/Default/UserDictionary/Words/=PERIODICLOG/@EntryIndexedValue">True</s:Boolean>
<s:Boolean x:Key="/Default/UserDictionary/Words/=POWERMON/@EntryIndexedValue">True</s:Boolean>
<s:Boolean x:Key="/Default/UserDictionary/Words/=Preadjustment/@EntryIndexedValue">True</s:Boolean>
<s:Boolean x:Key="/Default/UserDictionary/Words/=prot/@EntryIndexedValue">True</s:Boolean>
<s:Boolean x:Key="/Default/UserDictionary/Words/=restorable/@EntryIndexedValue">True</s:Boolean>
+27 -1
View File
@@ -9,7 +9,10 @@ namespace Xylem.Common.CommonCore.Configuration
/// </summary>
public static class ServiceUrls
{
private const String DefaultInspectCordonelRequirementInfoUrl =
"http://sla12iis01.emea.sensus.net/LaaProductionWeb/";
// return code: 404 not found, 400 Error with text, 200 okay
private const String DefaultEolDataForSentinelServiceUrl =
"http://sla12iis01.emea.sensus.net/LaaProductionWeb/api/cordonel/eolprogress/";
@@ -143,6 +146,9 @@ namespace Xylem.Common.CommonCore.Configuration
private const String DefaultGenesisCalibrationResult =
"http://sla12iis01.emea.sensus.net/MeterProcessState/api/GenesisMeter/PostCalibrationResult";
private const String DefaultGetGenesisCalibrationResults =
"http://sla12iis01.emea.sensus.net/MeterProcessState/api/FinalCheck/CalibrationResults/";
private const String DefaultGenesisMeter =
"http://sla12iis01.emea.sensus.net/MeterProcessState/api/GenesisMeter/";
@@ -390,6 +396,16 @@ namespace Xylem.Common.CommonCore.Configuration
DefaultSetCordonelAppVersionServiceUrl;
}
/// <summary>
/// Inspect a specific requirement (read only).
/// </summary>
/// <returns></returns>
public static String InspectCordonelRequirementInfoServiceUrl()
{
return ConfigurationManager.AppSettings["InspectCordonelRequirementInfoServiceUrl"] ??
DefaultInspectCordonelRequirementInfoUrl;
}
/// <summary>
/// Get all production infos for skip process checks or limits for production like:
/// - Battery drained percentage upper limit,
@@ -716,6 +732,16 @@ namespace Xylem.Common.CommonCore.Configuration
DefaultGetSoftwareStartUpAccessUrl;
}
/// <summary>
/// Get Genesis calibration results for final check if those have been correctly set
/// </summary>
/// <returns></returns>
public static String GetGenesisCalibrationResultsUrl()
{
return ConfigurationManager.AppSettings["GetGenesisCalibrationResults"] ??
DefaultGetGenesisCalibrationResults;
}
/// <summary>
/// Post Genesis calibration results
/// </summary>
@@ -198,6 +198,10 @@
<Project>{9EB1F659-6F73-4F65-BCAB-4114FD94F5FC}</Project>
<Name>CommonCore.Configuration</Name>
</ProjectReference>
<ProjectReference Include="..\CommonCore\CommonCore.csproj">
<Project>{1B02C79E-0B19-43E2-8F6B-71EF0C786C97}</Project>
<Name>CommonCore</Name>
</ProjectReference>
<ProjectReference Include="..\Hardware\WaterMeter\Genesis\Applications\Applications.csproj">
<Project>{315E94B8-B82F-4B25-B5BD-297DF3BC1D54}</Project>
<Name>Applications</Name>
@@ -588,7 +588,7 @@ namespace CordonelAssemblyLine.Model
var genesisStatus = new GenesisStatus();
// this calculates all life time values
if (!GenesisStatusHandler.BuildLifeTimeInformation(meter, genesisStatus))
if (!GenesisStatusHandler.BuildLifeTimeInformation(meter, genesisStatus, out _))
{
meter.WriteLog("Batterie nicht lesbar");
lblS08Text = "Batterie nicht lesbar";
@@ -228,8 +228,10 @@
<Compile Include="..\..\..\..\.shared\SharedAssemblyInfo.cs">
<Link>Properties\SharedAssemblyInfo.cs</Link>
</Compile>
<Compile Include="Consts\Alarm.cs" />
<Compile Include="Consts\PowCorrConst.cs" />
<Compile Include="Consts\MetrologyDefinition.cs" />
<Compile Include="IGenesisMeter.cs" />
<Compile Include="PowerCorrectionCalc.cs" />
<Compile Include="PowerCorrection.cs" />
<Compile Include="Consts\ErrorState.cs" />
File diff suppressed because it is too large Load Diff
@@ -0,0 +1,231 @@
using System;
using System.Collections.Generic;
using Xylem.Common.CommonCore.Consts;
using Xylem.Common.Hardware.Interfaces.Protocols.TransmitProtocol;
using Xylem.Common.Hardware.WaterMeter.Genesis.Applications;
using Xylem.Common.Hardware.WaterMeter.Genesis.GenesisConfig;
using Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Consts;
using Xylem.Common.Hardware.WaterMeter.Genesis.Registers;
using Xylem.Common.Hardware.WaterMeter.WaterMeterCore;
namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
{
/// <summary>
/// Interface of special GenesisMeter derived from IMeter
/// </summary>
public interface IGenesisMeter : IMeter
{
#region properties
/// <summary>
/// Represent <see cref="Register.Configexchange.PcbSerialNumber" />
/// proposed for login
/// </summary>
String PcbId
{
get;
}
/// <summary>
/// Transmit protocol access for underlie objects to change response timeout
/// </summary>
ITransmitProtocol TransmitProtocol{ get; }
/// <summary>
/// List of all present meter applications installed in meter
/// </summary>
List<MeterApplications> MeterAppListVersion
{
get;
}
/// <summary>
/// Successfully logged on to meter
/// </summary>
Boolean IsLoggedOn
{
get;
}
/// <summary>
/// Core revision of boot code.
/// </summary>
Int32? CoreRevision
{
get;
}
/// <summary>
/// Core revision of boot code as string.
/// </summary>
String StrCoreRevision
{
get;
}
/// <summary>
/// This is the FLEXNETVERSION version which describes the entire packet.
/// </summary>
String FwVersion
{
get;
}
/// <summary>
/// This is the FLEXNETVERSION version which describes the entire packet.
/// </summary>
UInt32? InstalledFwVersion
{
get;
}
/// <summary>
/// This is the Metrology Lookup Table CRC.
/// </summary>
String LutCrc
{
get;
}
/// <summary>
/// This is the meter size.
/// </summary>
String MeterSize
{
get;
}
/// <summary>
/// Region (EMEA, NA or China).
/// </summary>
String Region
{
get;
}
/// <summary>
/// Radio frequency in MHz (433 or 868 or null).
/// </summary>
Int32? RadioFrequencyMhz
{
get;
}
/// <summary>
/// Metrology upgrade permission.
/// </summary>
Byte MetrologyUpgradePermission
{
set; get;
}
/// <summary>
/// Order number under which this meter has to be produced
/// </summary>
Int32 OrderNumber
{
set; get;
}
/// <summary>
/// Radio address
/// </summary>
Int64 RadioAddress
{
set; get;
}
/// <summary>
/// Process configuration
/// </summary>
ProcessConfig Configuration
{
get;
}
/// <summary>
/// Customer serial number for informal issues
/// </summary>
String CustomerSerialNumber
{
get; set;
}
#endregion
#region methods
/// <summary>
/// Check region and size.
/// After reading the version, all valid registers are going to be selected.
/// </summary>
void CheckRegionSizeLutCrc();
/// <summary>
/// Reset the empty pipe alarm
/// </summary>
void ResetAlarm(Alarm clear);
/// <summary>
/// Upload app list to database
/// </summary>
/// <param name="progressName"></param>
/// <param name="version"></param>
/// <returns></returns>
StatusReturn PushProgress(String progressName, String version);
/// <summary>
/// Clear password to force new password reading
/// </summary>
void ClearPassword();
/// <summary>
/// Executes all StoreConfiguration and StoreCalibration for each application.
/// </summary>
/// <returns>true if all configurations are stored</returns>
Boolean StoreAllConfigurations();
/// <summary>
/// Login with identical password as last time to avoid get password from database
/// </summary>
Boolean ReLogin();
/// <summary>
/// Returns meter registers
/// </summary>
/// <returns></returns>
MeterRegisters GetConfigRegistersDefinitions();
/// <summary>
/// Common routine for reboot being able to override this routine which will be called in
/// MeteResetPsu to simulate a reboot.
/// </summary>
/// <returns></returns>
StatusReturn RebootGenesis();
/// <summary>
/// Write Register, optional: wait for result and validate,
/// write register will ALWAYS log the data DON'T use for password write
/// </summary>
/// <typeparam name="T">Data type of Register</typeparam>
/// <param name="regName">Register name</param>
/// <param name="value">Value to save as byte array in raw format</param>
/// <param name="waitForResult">wait until result is ready</param>
/// <param name="checkRegister">check the content of the register by read back</param>
/// <param name="skipRetryErrorCode">skip retries on this error code return</param>
/// <returns>true on successful operation</returns>
Boolean WriteRegister<T>(String regName, T value, Boolean waitForResult = true,
Boolean checkRegister = false, UInt16 skipRetryErrorCode = CommunicationConfig.SkipRetryErrorCode);
/// <summary>
/// Read Register and return byte array
/// </summary>
/// <param name="regName">Register name</param>
/// <param name="expectedLength">expected length for response</param>
/// <param name="skipRetryErrorCode">skip retries on this error code return</param>
/// <returns>value as byte array in raw format or null</returns>
Byte[] ReadRegister(String regName, Int32? expectedLength = null,
UInt16 skipRetryErrorCode = CommunicationConfig.SkipRetryErrorCode);
#endregion
}
}
@@ -4,6 +4,7 @@ using Xylem.Common.Hardware.WaterMeter.Genesis.DataPackages.MeasurementRecords;
using Xylem.Common.Hardware.WaterMeter.Genesis.GenesisConfig.Const;
using Xylem.Common.Hardware.WaterMeter.Genesis.Registers;
using Xylem.Common.Logic.ProductionOrderCore.TestResults;
using Xylem.Common.Logic.SoftwareAccessHelper;
using Xylem.Common.Metrology.Measurements;
using Xylem.Common.Metrology.Measurements.Consts;
@@ -31,7 +32,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// <inheritdoc />
public void InitCalibration()
{
_logger.Info($"Slot:{Slot} - Init calibration and set calibration values of all channels to default");
Logger.Info($"Slot:{Slot} - Init calibration and set calibration values of all channels to default");
for (var channel = 0; channel < MeterConfig.CalibChannels; channel++)
{
_calibFactor[channel] = new CalibFactor(channel, _registersToStoreCalibFactor[channel]);
@@ -84,11 +85,11 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
if (channel == 0 || channel > MeterConfig.CalibChannels)
{
var message = $"Slot:{Slot}, Channel:{channel} - Calibration channel out of range";
_logger.Warn(message);
Logger.Warn(message);
throw new ApplicationException(message);
}
_logger.Info($"Slot:{Slot}, Channel:{channel} - Calculate Calibrationfactor Relative(RefVolumeCm:{refVolumeCm}, refTimeS:{refTimeS},reqDeviationPercent:{reqDeviationPercent})");
Logger.Info($"Slot:{Slot}, Channel:{channel} - Calculate Calibrationfactor Relative(RefVolumeCm:{refVolumeCm}, refTimeS:{refTimeS},reqDeviationPercent:{reqDeviationPercent})");
var calibFactorRel = calib.CalculateCalibFactorRel(refVolumeCm, refTimeS, reqDeviationPercent);
@@ -96,7 +97,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
if (null == calibFactorRel)
{
var message = $"Slot:{Slot}, Channel:{channel} - Calibration factor not calculated";
_logger.Warn(message);
Logger.Warn(message);
throw new ApplicationException(message);
}
@@ -104,9 +105,9 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
_calibFactor[channel - 1].BuildMeterCalibFactor(calibFactorRel.Value);
_calibFactor[channel - 1].IsCalculated = true;
_logger.Info($"Slot:{Slot}, Channel:{channel} - New calibration factor({_calibFactor[channel - 1].GetRelativeCalibFactor()}rel/{calibFactorRel})");
Logger.Info($"Slot:{Slot}, Channel:{channel} - New calibration factor({_calibFactor[channel - 1].GetRelativeCalibFactor()}rel/{calibFactorRel})");
_logger.Info($"Slot:{Slot}, Channel:{channel} - Calc /{ _calibFactor[channel - 1].GetMeterRawCalibFactor()} * {calibFactorRel.Value}) -> UInt16");
Logger.Info($"Slot:{Slot}, Channel:{channel} - Calc /{ _calibFactor[channel - 1].GetMeterRawCalibFactor()} * {calibFactorRel.Value}) -> UInt16");
//Setup the required tolerance value to check against
@@ -123,12 +124,12 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
var warnMessage = $"Slot:{Slot}, Channel:{channel} - " +
$"Calibration factor is out of range({calibFactorRel.Value}rel)";
_logger.Warn(warnMessage);
Logger.Warn(warnMessage);
throw new ApplicationException(warnMessage);
}
var t = new JustageResults()
var t = new JustageResults
{
pcbId = PcbId,
p1Target = reqDeviationPercent,
@@ -144,15 +145,15 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
try
{
var tmpUrl = $"http://10.49.40.25/MeterProcessState/api/TestBench/SetCalibrationValues";
_logger.Info($"Request Url: { tmpUrl}");
var tmpUrl = "http://10.49.40.25/MeterProcessState/api/TestBench/SetCalibrationValues";
Logger.Info($"Request Url: { tmpUrl}");
//ToDO: Update to service URl
Logic.SoftwareAccessHelper.LocalWebRequest.PostAsJson<JustageResults>(t, tmpUrl);
LocalWebRequest.PostAsJson<JustageResults>(t, tmpUrl);
}
catch (Exception ex)
{
_logger.Error($"Request Url: { ex.Message}");
Logger.Error($"Request Url: { ex.Message}");
}
@@ -163,7 +164,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
public void SetCalibFactorsAllChannels(Boolean justLog = false)
{
WriteRegister<Byte>(Register.Genesisflow.SampleRate, 2, checkRegister: true);
WriteRegister<UInt16>(Register.Genesisflow.TriggerIdle, 0x1234, true);
WriteRegister<UInt16>(Register.Genesisflow.TriggerIdle, 0x1234);
for (var channel = 0; channel < MeterConfig.CalibChannels; channel++)
{
@@ -174,14 +175,14 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
if (justLog)
{
_logger.Warn($"Slot:{Slot} - Calculated calibration factors but not stored to registers");
Logger.Warn($"Slot:{Slot} - Calculated calibration factors but not stored to registers");
}
else
{
var registerRawCalibFactor = _calibFactor[channel].GetMeterRawCalibFactor();
var resultWrite = WriteRegister(_calibFactor[channel].RegisterToStoreCalibFactor,
registerRawCalibFactor, checkRegister: true);
_logger.Info($"Slot:{Slot}, Channel:{channel} - Stored calibration factor({_registersToStoreCalibFactor[channel]})");
Logger.Info($"Slot:{Slot}, Channel:{channel} - Stored calibration factor({_registersToStoreCalibFactor[channel]})");
//if (!string.IsNullOrEmpty(SerialNumber) && CurrentActionText.Contains("PG"))
//{
@@ -198,7 +199,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
//
if (resultWrite)
{
_logger.Warn($"Set calibration went wrong {_calibFactor[channel].RegisterToStoreCalibFactor}, with {registerRawCalibFactor}");
Logger.Warn($"Set calibration went wrong {_calibFactor[channel].RegisterToStoreCalibFactor}, with {registerRawCalibFactor}");
}
}
}
@@ -206,11 +207,11 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
WriteRegister(Register.Genesisflow.ResetAccumulators, true);
//WriteRegister<UInt16>(Register.Genesisflow.ForwardArrow, 0, checkRegister: true);
WriteRegister<UInt16>(Register.Genesisflow.StoreCalibration, 1, true);
WriteRegister<UInt16>(Register.Genesisflow.StoreCalibration, 1);
_logger.Info($"Slot:{Slot} - StoreCalibration { RegisterConverter.ByteArrayToValue<UInt16>(ReadRegister(Register.Genesisflow.StoreCalibration))}");
WriteRegister<UInt16>(Register.Genesisflow.TriggerActive, 1, true);
_logger.Info($"Slot:{Slot} - Set forward arrow of LCD, reset accumulators, set sample rate to 2Hz");
Logger.Info($"Slot:{Slot} - StoreCalibration { RegisterConverter.ByteArrayToValue<UInt16>(ReadRegister(Register.Genesisflow.StoreCalibration))}");
WriteRegister<UInt16>(Register.Genesisflow.TriggerActive, 1);
Logger.Info($"Slot:{Slot} - Set forward arrow of LCD, reset accumulators, set sample rate to 2Hz");
WriteRegister<Byte>(Register.Genesisflow.SampleRate, 10, checkRegister: true);
}
}
@@ -39,7 +39,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// </summary>
public void InitMeasurement()
{
_logger.Info($"Slot:{Slot} - Init measurement");
Logger.Info($"Slot:{Slot} - Init measurement");
PreMeasurement();
}
@@ -62,7 +62,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
displayState = ReadRegister(Register.Genesisflow.TriggerIdle);
if (displayState == null)
{
_logger.Info($"Slot:{Slot} - Not able to read display state");
Logger.Info($"Slot:{Slot} - Not able to read display state");
return;
}
}
@@ -123,7 +123,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
measurement.OnActionStateHasChanged += Measurement_ActionStateHasChanged;
}
_logger.Info($"Slot:{Slot} - Start measurement");
Logger.Info($"Slot:{Slot} - Start measurement");
ProcessStatus = ProcessState.MeasurementIsActive;
_listOfIMeasurement.ForEach(m => m.MeasurementState = MeasurementStates.IsWaitingForStartData);
@@ -134,7 +134,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// <inheritdoc />
public void StopMeasurement()
{
_logger.Info($"Slot:{Slot} - Stop measurement");
Logger.Info($"Slot:{Slot} - Stop measurement");
ProcessStatus = ProcessState.MeasurementIsDone;
_listOfIMeasurement.ForEach(m => m.MeasurementState = MeasurementStates.IsWaitingForEndData);
SyncStreamingBuffer(SyncMarkRecord.SyncEnd);
@@ -199,7 +199,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
? mainMeasurement.GetIntermediateMeasurementResult(refVolume, refTimeS)
: mainMeasurement.GetFinalMeasurementResult(refVolume, refTimeS);
results.Add(mainResult);
_logger.Info($"Slot:{Slot}, Channel:{mainMeasurement.GetChannel()} - MeasuredTime({mainResult.DutTimeS}s), " +
Logger.Info($"Slot:{Slot}, Channel:{mainMeasurement.GetChannel()} - MeasuredTime({mainResult.DutTimeS}s), " +
$"MeasuredVolume({mainResult.DutVolumeCm}Qm)");
foreach (var otherMeasurement in _listOfIMeasurement.Where(m => m.GetType() != typeof(FlowTestRecord)))
@@ -209,13 +209,13 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
var otherResults = intermediateMeasurement
? otherMeasurement.GetIntermediateMeasurementResult(refVolume, refTimeS)
: otherMeasurement.GetFinalMeasurementResult(refVolume, refTimeS);
_logger.Info($"Slot:{Slot}, Channel:{otherMeasurement.GetChannel()} - ChannelTime({otherResults.DutTimeS}s), " +
Logger.Info($"Slot:{Slot}, Channel:{otherMeasurement.GetChannel()} - ChannelTime({otherResults.DutTimeS}s), " +
$"ChannelVolume({otherResults.DutVolumeCm}Qm)");
results.Add(otherResults);
}
catch (Exception ex)
{
_logger.Warn($"Slot:{Slot}, No Results for channel:{otherMeasurement.GetChannel()} Ex: {ex.Message}");
Logger.Warn($"Slot:{Slot}, No Results for channel:{otherMeasurement.GetChannel()} Ex: {ex.Message}");
if (channel == null)
{
throw new ApplicationException($"Can not read result from channel:{otherMeasurement.GetChannel() } Ex: {ex.Message}");
@@ -261,7 +261,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// <inheritdoc />
public MeasurementStates GetMeasurementState(Int32? onlyChannelNr = null)
{
_logger.Trace($"Slot:{Slot} - Get measurement state");
Logger.Trace($"Slot:{Slot} - Get measurement state");
if (!_listOfIMeasurement.Any())
{
return MeasurementStates.NotStarted;
@@ -278,7 +278,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
/// <inheritdoc />
public Boolean RequestIntermediateMeasurementState(Int32? onlyChannelNr = null)
{
_logger.Trace($"Slot:{Slot} - Get measurement state");
Logger.Trace($"Slot:{Slot} - Get measurement state");
if (!_listOfIMeasurement.Any())
{
return false;
@@ -3,96 +3,50 @@
namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisStatus
{
/// <summary>
/// Status of Cordonel like:
/// - Battery drainage,
/// - Production date of electronics,
/// - Due date for production,
/// - Remaining life time,
/// - Special permissions for production capability check for
/// - Battery Drainage in %,
/// - Remaining Life Time in years,
/// - Production Due Date as DateTime.
/// Status of Cordonel calculated out of the Cordonel readouts
/// </summary>
public class GenesisStatus
{
/// <summary>
/// Data base primary key
/// Average days per month based on 365.25 [Days/Year] / 12 [Months/Year] = 30.4375
/// </summary>
public Int32 Id { get; set; }
public const Double DAYS_PER_MONTH = 30.4375d;
/// <summary>
/// Order number
/// Average seconds per month
/// </summary>
public Int32? OrderNumber { get; set; }
public const Double SECONDS_PER_MONTH = 3600 * 24 * DAYS_PER_MONTH;
/// <summary>
/// PcbId.
/// Months from seconds
/// </summary>
public String PcbId { get; set; }
public const Double MONTHS_FROM_SECONDS = 1.0d / SECONDS_PER_MONTH;
/// <summary>
/// Skip radio parameter check
/// Calculate years from seconds taking the leap year into account
/// </summary>
public Boolean SkipRadioParametersCheck { get; set; }
public const Double YEARS_FROM_SECONDS = 1.0d / (3600.0 * 24.0 * 365.25);
/// <summary>
/// Override FW version. Normally the FW will be assigned to the latest released version
/// and taken from the data base. Here special versions can be used for FW tests.
/// null means take the current released version
/// Convert milli-ampere-hours to micro-ampere-seconds
/// </summary>
public Int32? OverrideFwCheck { get; set; }
public const Double MILLI_AMPERE_HOURS_TO_MICRO_AMPERE_SECONDS = 1000.0d * 3600.0;
/// <summary>
/// override the Lut version to check the look-up-table installation as this device may be used for development.
/// null means take the current released version
/// </summary>
public Int32? OverrideLutCheck { get; set; }
/// <summary>
/// Internally used to signal that production and shipping is proved and validated.
/// </summary>
public Boolean ProductionAccepted { get; set; }
/// <summary>
/// Date and time of production of electronics.
/// </summary>
public DateTime KitronProductionDate { get; set; }
/// <summary>
/// Last date until production has to be finished, can be extended by special permission
/// </summary>
public DateTime ProductionDueDate { get; set; }
/// <summary>
/// Remaining life time for Cordonel in years based on battery drainage.
/// Remaining lifetime for Cordonel in years based on battery drainage.
/// </summary>
public Double RemainingLifeTimeYears { get; set; }
/// <summary>
/// Exceeded life time of all batteries in seconds.
/// Exceeded lifetime of all batteries in seconds.
/// </summary>
public UInt64 ExceededLifeTime_s { get; set; }
/// <summary>
/// Required life time in years for assembly, is dependent on region and special permission.
/// </summary>
public Double RequiredLifeTimeYearsAssembly { get; set; }
/// <summary>
/// Required life time in years for shipping, is dependent on region and special permission.
/// </summary>
public Double RequiredLifeTimeYearsShipping { get; set; }
/// <summary>
/// Battery drainage in percent.
/// </summary>
public Double DrainedBatteryLoadPercent { get; set; }
/// <summary>
/// Maximum drained Battery load in percent.
/// </summary>
public Double MaxDrainedBatteryLoadPercent { get; set; }
/// <summary>
/// Number of batteries attached to Cordonel.
/// </summary>
@@ -103,41 +57,42 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisStatus
/// </summary>
public UInt64 InitialBatteryLoad_mAh { get; set; }
/// <summary>
/// Quiescent current used for alternative calculation of threshold for
/// maximum remaining battery load given by Cordonel requirements.
/// If this values and the <see cref="EstimatedProductionBatteryLoadPercent"/>
/// is set, this has a higher priority as the normal threshold.
/// </summary>
public Double? QuiescentCurrent_uA { get; set; }
///<summary>
///Additional allowed load for production used for alternative calculation of
/// threshold for maximum remaining battery load given by Cordonel requirements.
/// If this values and the <see cref="QuiescentCurrent_uA"/>
/// is set, this has a higher priority as the normal threshold.
/// </summary>
public Double? EstimatedProductionBatteryLoadPercent { get; set; }
/// <summary>
/// Drained capacity of all batteries in uAs.
/// </summary>
public UInt64 DrainedBatteryLoad_uAs { get; set; }
/// <summary>
/// Alternative calculation of required battery load in percent based on quiescent
/// current multiplied by operational time and supplement for production.
/// </summary>
public Double? AlternativeRequiredBatteryLoadPercent { get; internal set; }
/// <summary>
/// Battery assembly time based on the POWERMON_TotalUsedSeconds and the current time in UTC.
/// </summary>
public DateTime? BatteryAssemblyDateTimeUtc { get; internal set; }
/// <summary>
/// Comment for approval and permissions reasons:
/// e.g. "On customer requirement for test purposes the life time isn't of importance".
/// Calculation of storage months based on assembly time and UtcNow.
/// </summary>
public String ApprovalComment { get; set; }
/// <summary>
/// Name of approver for special permissions.
/// </summary>
public String ApproverName { get; set; }
/// <summary>
/// Date of approval.
/// </summary>
public DateTime ApprovalDate { get; set; }
/// <summary>
/// Uniontown limits
/// </summary>
public Double UNTLimit { get; internal set; }
/// <summary>
/// Uniontown status
/// </summary>
public Boolean UNTStatus { get; internal set; }
public Double EMEALimit { get; internal set; }
public Boolean EMEAStatus { get; internal set; }
public Double PreProductionUNTLimit { get; internal set; }
public Boolean PreProductionUNTStatus { get; internal set; }
public Double PreProductionEMEALimit { get; internal set; }
public Boolean PreProductionEMEAStatus { get; internal set; }
public Double? StorageMonths { get; internal set; }
}
}
@@ -61,10 +61,18 @@
<Project>{9EB1F659-6F73-4F65-BCAB-4114FD94F5FC}</Project>
<Name>CommonCore.Configuration</Name>
</ProjectReference>
<ProjectReference Include="..\..\..\..\Logic\ProductionOrderCore\ProductionOrderCore.csproj">
<Project>{6D2777BB-7A88-466D-A49B-3266F9BF0160}</Project>
<Name>ProductionOrderCore</Name>
</ProjectReference>
<ProjectReference Include="..\..\..\..\SoftwareAccessHelper\SoftwareAccessHelper.csproj">
<Project>{A33E3C6D-EAAE-4A20-A0EE-F9E6922FD029}</Project>
<Name>SoftwareAccessHelper</Name>
</ProjectReference>
<ProjectReference Include="..\..\WaterMeterCore\WaterMeterCore.csproj">
<Project>{8203abb8-38e5-472e-a742-33f38b7a74a6}</Project>
<Name>WaterMeterCore</Name>
</ProjectReference>
<ProjectReference Include="..\GenesisCore\GenesisCore.csproj">
<Project>{04201E95-90A0-4B73-A72F-379739B2A3AE}</Project>
<Name>GenesisCore</Name>
@@ -1,14 +1,19 @@
using System;
using System.Collections.Generic;
using System.Net;
using LaaPackages.Features.Cordonel.Models;
using Newtonsoft.Json;
using Xylem.Common.CommonCore.Configuration;
using Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore;
using Xylem.Common.Hardware.WaterMeter.Genesis.Registers;
using Xylem.Common.Logic.SoftwareAccessHelper;
using Xylem.Common.Logic.ProductionOrderCore.TestResults;
namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisStatus
{
/// <summary>
/// Handler for the production status check. This will be feed by the DB.
/// The base is the standard requirement or the special requirement.
/// - Calculation of drained battery,
/// - Assembly capability check,
/// - Shipping capability check.
@@ -16,86 +21,181 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisStatus
public static class GenesisStatusHandler
{
/// <summary>
/// Get all production infos for skip process checks or limits for production like:
/// Get all production infos out of the "CordonelRequirements" which can be "StandardRequirements" or
/// "SpecialRequirements". The call of "CordonelRequirements" will automatically select the active
/// requirement with priority to the "SpecialRequirement".
/// - Battery drained percentage upper limit,
/// - Production due date for a special register,
/// - Required life time for assembly line,
/// - Required life time for shipping line.
/// - Required lifetime for assembly line,
/// - Required lifetime for shipping line.
/// </summary>
/// <param name="pcbId"></param>
/// <param name="orderNumber"></param>
/// <param name="productionStatus"></param>
/// <param name="prodRequirements"></param>
/// <param name="errorMsg"></param>
/// <returns>true if successfully executed</returns>
/// <remarks date="2023-Mar-02" author="Roland Drabesch/Thomas Wiedebusch">
/// - Initial.
/// </remarks>
/// <remarks date="2024-Jan-23" author="Roland Drabesch/Thomas Wiedebusch">
/// - Clone all properties coming from data base to reference (deep clone).
/// - Clone all properties coming from database to reference (deep clone).
/// </remarks>
public static Boolean GetProductionSkipAndLifeTimeInfoFromDb(String pcbId, Int32 orderNumber,
GenesisStatus productionStatus)
/// <remarks date="2024-Jul-19" author="Thomas Wiedebusch">
/// - Changed from "ProductionSkipAndLifeTimeInfo" to "CordonelRequirements".
/// </remarks>
/// <remarks date="2024-Dec-17" author="Thomas Wiedebusch">
/// - Overwrite production "ProductionOrderNr" if null with "OuterProductionOrderNr" which is standard for
/// standard requirements as those are neither PcbId based nor order number based.
/// </remarks>
public static Boolean GetCordonelRequirementInfoFromDb(String pcbId, CordonelRequirements prodRequirements,
out String errorMsg)
{
if (string.IsNullOrEmpty(pcbId) || productionStatus == null)
errorMsg = "";
if (null == prodRequirements || string.IsNullOrEmpty(pcbId))
{
return false;
}
GenesisStatus status;
try
{
var url = ""; // ServiceUrls.GetProductionSkipAndLifeTimeInfoServiceUrl();
url += $"{pcbId}&orderNumber={orderNumber}";
var response = LocalWebRequest.GetRequest(url, 2000);
status = JsonConvert.DeserializeObject<GenesisStatus>(response);
if (status == null)
var url = ServiceUrls.GetCordonelRequirementInfoServiceUrl();
url += pcbId;
var response = LocalWebRequest.GetRequest(url, 30000, out var httpStatus);
if (httpStatus == HttpStatusCode.OK && !string.IsNullOrEmpty(response))
{
return false;
var requirements = JsonConvert.DeserializeObject<CordonelRequirements>(response);
var type = typeof(CordonelRequirements);
foreach (var prop in type.GetProperties())
{
if (prop.CanWrite)
prop.SetValue(prodRequirements, prop.GetValue(requirements, null), null);
}
// For standard requirements the order number has to be set as those are neither PcbId based
// nor order number based
if (prodRequirements.ProductionOrderNr == null)
prodRequirements.ProductionOrderNr = prodRequirements.OuterProductionOrderNr;
return true;
}
}
catch (Exception )
catch (Exception e)
{
errorMsg = e.Message;
return false;
}
return false;
}
/// <summary>
/// Get the calibration results for a meter from a test-bench calibration.
/// </summary>
/// <param name="pcbId"></param>
/// <param name="calibResults"></param>
/// <param name="errorMsg"></param>
/// <returns></returns>
/// <remarks date="2024-11-09" author="Thomas Wiedebusch">
/// - Initial.
/// </remarks>
public static Boolean GetCalibrationResultsFromDb(String pcbId, CalibrationResults calibResults,
out String errorMsg)
{
errorMsg = "";
if (null == calibResults || string.IsNullOrEmpty(pcbId))
{
return false;
}
var type = typeof(GenesisStatus);
foreach (var prop in type.GetProperties())
try
{
try
var url = ServiceUrls.GetGenesisCalibrationResultsUrl();
url += pcbId;
var requestResponse = LocalWebRequest.GetRequest(url, 30000, out var httpStatus);
if (httpStatus == HttpStatusCode.OK && !string.IsNullOrEmpty(requestResponse))
{
if( prop.CanWrite)
prop.SetValue(productionStatus, prop.GetValue(status, null), null);
}
catch (Exception)
{
// nothing to do, go ahead
var calibRes = JsonConvert.DeserializeObject<CalibrationResults>(requestResponse);
// ClassAccess.CopyProperties(calibResults, calibRes);
var type = typeof(CalibrationResults);
foreach (var prop in type.GetProperties())
{
if (prop.CanWrite)
prop.SetValue(calibResults, prop.GetValue(calibRes, null), null);
}
return true;
}
}
catch (Exception e)
{
errorMsg = e.Message;
return false;
}
return true;
return false;
}
/// <summary>
/// Read and calculate life time information.
/// Get the state of executed flow tests for a meter from a test-bench run.
/// </summary>
/// <param name="pcbId"></param>
/// <param name="testBenchState"></param>
/// <param name="errorMsg"></param>
/// <returns></returns>
/// <remarks date="2024-11-09" author="Thomas Wiedebusch">
/// - Initial.
/// </remarks>
public static Boolean GetFlowTestStateFromDb(String pcbId, List<String> testBenchState, out String errorMsg)
{
errorMsg = "";
if (testBenchState == null || string.IsNullOrEmpty(pcbId))
{
return false;
}
try
{
var url = ServiceUrls.MeterInfoForTestBench() + pcbId;
var requestResponse = LocalWebRequest.GetRequest(url, 30000, out var httpStatus);
if (httpStatus == HttpStatusCode.OK && !string.IsNullOrEmpty(requestResponse))
{
var state = JsonConvert.DeserializeObject<String[]>(requestResponse);
testBenchState.AddRange(state);
return true;
}
}
catch (Exception e)
{
errorMsg = e.Message;
return false;
}
return false;
}
/// <summary>
/// Read and calculate lifetime information.
/// </summary>
/// <param name="currentGenesis"></param>
/// <param name="status"></param>
/// <param name="errorMsg"></param>
/// <returns></returns>
/// <remarks date="2023-Mar-02" author="Thomas Wiedebusch">
/// - Initial.
/// </remarks>
public static Boolean BuildLifeTimeInformation(GenesisMeter currentGenesis, GenesisStatus status)
/// <remarks date="2024-Nov-15" author="Thomas Wiedebusch">
/// - errorMsg.
/// </remarks>
public static Boolean BuildLifeTimeInformation(IGenesisMeter currentGenesis, GenesisStatus status, out String errorMsg)
{
Boolean retVal;
if (currentGenesis == null || status == null) return false;
errorMsg = "";
if (currentGenesis == null || status == null)
return false;
// read information from genesis
try
{
if (!currentGenesis.IsLoggedOn) currentGenesis.Login();
if (!currentGenesis.IsLoggedOn)
currentGenesis.Login();
status.ExceededLifeTime_s = RegisterConverter.ByteArrayToValue<UInt32>(
currentGenesis.ReadRegister(Register.Powermon.BatteryExceededSeconds));
status.DrainedBatteryLoad_uAs = RegisterConverter.ByteArrayToValue<UInt64>(
@@ -109,15 +209,16 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisStatus
retVal = CalculateLifeTime(status);
}
catch (Exception)
catch (Exception e)
{
retVal = false;
errorMsg = e.Message;
return false;
}
return retVal;
}
/// <summary>
/// Calculation of life time values.
/// Calculation of lifetime values.
/// </summary>
/// <param name="status"></param>
/// <returns>true if all calculations could be executed</returns>
@@ -127,54 +228,62 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisStatus
/// <remarks date="2023-Dec-??" author="Roland Drahbesch">
/// - Uniontown limits UNT.
/// </remarks>
/// <remarks date="2024-Sep-25" author="Thomas Wiedebusch">
/// - Alternative calculation based on quiescent current and production supplement instead of UNT limits.
/// </remarks>
/// <remarks date="2024-Oct-22" author="Thomas Wiedebusch">
/// - Battery assembly time calculation added.
/// </remarks>
/// <remarks date="2024-Nov-25" author="Thomas Wiedebusch">
/// - Exit if essential inputs missing.
/// </remarks>
/// <remarks date="2025-Mar-25" author="Thomas Wiedebusch">
/// - Calculate storage months.
/// </remarks>
public static Boolean CalculateLifeTime(GenesisStatus status)
{
var retVal = true;
// Mark as false if the basic inputs are missed
if (status == null ||
status.InitialBatteryLoad_mAh == 0 ||
status.BatteryQuantity == 0 ||
status.DrainedBatteryLoad_uAs == 0 ||
status.ExceededLifeTime_s == 0)
{
return false;
}
// Calculate the initial overall battery load of all batteries in uAs as the drained load uses this unit.
var initialBatteryLoad_uAs = 1000 * 3600 * status.InitialBatteryLoad_mAh * (UInt64)status.BatteryQuantity;
var initialBatteryLoad_uAs = GenesisStatus.MILLI_AMPERE_HOURS_TO_MICRO_AMPERE_SECONDS * status.InitialBatteryLoad_mAh * status.BatteryQuantity;
// Relation of drained to initial load, set the battery to fully unloaded for failed check to force a recalculation
var drainedBatteryLoad_rel = 1.0;
if (initialBatteryLoad_uAs != 0)
{
drainedBatteryLoad_rel = (Double)status.DrainedBatteryLoad_uAs / initialBatteryLoad_uAs;
}
else
{
retVal = false;
}
status.DrainedBatteryLoadPercent = drainedBatteryLoad_rel * 100;
// The estimated life time uses the drained load over the actual exceeded life time and assumes, that further on
// an identical load will be consumed over the remaining life cycle. The initial load will be multiplied with the
// drained load relation. Set the estimated time to the exceeded time to force a recalculation on failed input.
var estimatedLifeTime_s = (Double)status.ExceededLifeTime_s;
if (drainedBatteryLoad_rel != 0.0)
{
estimatedLifeTime_s = status.ExceededLifeTime_s / drainedBatteryLoad_rel;
}
else
{
retVal = false;
}
var drainedBatteryLoad_rel = status.DrainedBatteryLoad_uAs / initialBatteryLoad_uAs;
status.DrainedBatteryLoadPercent = drainedBatteryLoad_rel * 100.0;
// The estimated lifetime uses the drained load over the actual exceeded lifetime and assumes, that further on
// an identical load will be consumed over the remaining life cycle.
var estimatedLifeTime_s = status.ExceededLifeTime_s / drainedBatteryLoad_rel;
var remainingLifetime_s = estimatedLifeTime_s - status.ExceededLifeTime_s;
// convert the seconds to years
status.RemainingLifeTimeYears = remainingLifetime_s / 3600 / 24 / 365.25;
status.RemainingLifeTimeYears = remainingLifetime_s * GenesisStatus.YEARS_FROM_SECONDS;
status.UNTLimit = 1368000000 + (status.ExceededLifeTime_s * 77.7);
status.UNTStatus = status.UNTLimit >= status.DrainedBatteryLoad_uAs;
// Calculate an alternative threshold for remaining battery load based on the quiescent current and a supplement
// for production purpose. Those values can be assigned in the Cordonel requirements.
if (status.QuiescentCurrent_uA != null &&
status.QuiescentCurrent_uA > 0 &&
status.EstimatedProductionBatteryLoadPercent != null)
{
status.AlternativeRequiredBatteryLoadPercent =
// The additional free power for production purposes
(Double)status.EstimatedProductionBatteryLoadPercent +
// The power consumption based on the actual lifetime and consumed current in relation to absolute load
status.ExceededLifeTime_s * (Double)status.QuiescentCurrent_uA / initialBatteryLoad_uAs * 100.0;
}
status.EMEALimit = 1368000000 + (status.ExceededLifeTime_s * 119.8);
status.EMEAStatus = status.UNTLimit >= status.DrainedBatteryLoad_uAs;
status.PreProductionUNTLimit = (1368000000/2) + (status.ExceededLifeTime_s * 77.7);
status.PreProductionUNTStatus = status.UNTLimit >= status.DrainedBatteryLoad_uAs;
status.PreProductionEMEALimit = (1368000000 / 2) + (status.ExceededLifeTime_s * 119.8);
status.PreProductionEMEAStatus = status.UNTLimit >= status.DrainedBatteryLoad_uAs;
return retVal;
// Calculate battery assembly time
var actualDate = DateTime.UtcNow;
status.BatteryAssemblyDateTimeUtc = actualDate.AddSeconds(-(Double)status.ExceededLifeTime_s);
var timeDifference = actualDate - status.BatteryAssemblyDateTimeUtc;
status.StorageMonths = timeDifference.GetValueOrDefault().TotalSeconds * GenesisStatus.MONTHS_FROM_SECONDS;
return true;
}
}
}
@@ -0,0 +1,39 @@
Release summary for product 1.69
Block ./Zero/objects/zero
Id 0x00, CRC 0x3F95, size 36868 bytes, version 4.98
Block ../../Applications/PowerMon/powermon
Id 0x01, CRC 0x9ACE, size 3068 bytes, version 0.67
Block ../../Applications/ConfigExchange/configex
Id 0x04, CRC 0xF967, size 8036 bytes, version 2.19
Block ../../Applications/Logger/logger
Id 0x08, CRC 0xDC48, size 3972 bytes, version 0.17
Block ../../Applications/PeriodicLogging/periodiclog
Id 0x11, CRC 0x92E5, size 12540 bytes, version 0.70
Block ../../Applications/Communications/SensusRFRadio/SensusRF_433
Id 0x10, CRC 0x731F, size 79504 bytes, version 4.76
Block ../../Applications/Metrology/Water/GenesisFlow/genesisflow
Id 0x0F, CRC 0x8228, size 23300 bytes, version 2.87
Block ../../Applications/Customer/GenesisDefault/customer
Id 0x09, CRC 0xE3CF, size 6104 bytes, version 1.52
Block ../../Applications/MetrologyAssistant/assistant
Id 0x12, CRC 0xF798, size 7728 bytes, version 1.07
Block ../../Applications/Communications/IrDA/irda
Id 0x14, CRC 0x8376, size 23144 bytes, version 1.98
Block ../../Applications/Communications/NFC/nfc
Id 0x15, CRC 0xB3D8, size 6424 bytes, version 0.53
Block ../../Applications/FlexNetVersion/flexnetversion
Id 0x18, CRC 0xB848, size 116 bytes, version 11.07
Minimum supported core revision: "Cordonel 1.62"
Maximum supported core revision: "Cordonel 1.69"
@@ -0,0 +1,40 @@
Release summary for product 1.71
Block ./Zero/objects/zero
Id 0x00, CRC 0x2325, size 37728 bytes, version 5.17
Block ../../Applications/PowerMon/objects/powermon
Id 0x01, CRC 0x2527, size 3068 bytes, version 0.68
Block ../../Applications/ConfigExchange/objects/configex
Id 0x04, CRC 0x0822, size 7904 bytes, version 2.26
Block ../../Applications/Logger/objects/logger
Id 0x08, CRC 0x12D4, size 3972 bytes, version 0.18
Block ../../Applications/PeriodicLogging/objects/periodiclog
Id 0x11, CRC 0x5E72, size 12528 bytes, version 0.73
Block ../../Applications/Communications/SensusRFRadio/objects/SensusRF
Id 0x10, CRC 0xFFCE, size 81820 bytes, version 4.93
Block ../../Applications/Metrology/Water/GenesisFlow/objects/genesisflow
Id 0x0F, CRC 0xA3A6, size 25164 bytes, version 3.02
Block ../../Applications/Customer/GenesisDefault/objects/customer
Id 0x09, CRC 0xAEC5, size 6148 bytes, version 1.55
Block ../../Applications/MetrologyAssistant/objects/assistant
Id 0x12, CRC 0xB4D5, size 7948 bytes, version 1.11
Block ../../Applications/Communications/IrDA/objects/irda
Id 0x14, CRC 0x2EB1, size 23324 bytes, version 2.06
Block ../../Applications/Communications/NFC/objects/nfc
Id 0x15, CRC 0xCE04, size 6452 bytes, version 0.57
Block ../../Applications/FlexNetVersion/objects/flexnetversion
Id 0x18, CRC 0xBA83, size 116 bytes, version 12.47
Minimum supported core revision: "Cordonel 1.62"
Maximum supported core revision: "Cordonel 1.71"
@@ -0,0 +1,40 @@
Release summary for product 1.78
Block ./Zero/objects/zero
Id 0x00, CRC16 0x39A8, size 37972 bytes, version 5.37
Block ../../Applications/PowerMon/objects/powermon
Id 0x01, CRC16 0xB16C, size 3112 bytes, version 0.70
Block ../../Applications/ConfigExchange/objects/configex
Id 0x04, CRC16 0x8290, size 7944 bytes, version 2.38
Block ../../Applications/Logger/objects/logger
Id 0x08, CRC16 0x12D4, size 3972 bytes, version 0.18
Block ../../Applications/PeriodicLogging/objects/periodiclog
Id 0x11, CRC16 0x5796, size 12412 bytes, version 0.75
Block ../../Applications/Communications/SensusRFRadio/objects/SensusRF
Id 0x10, CRC16 0x0704, size 93488 bytes, version 5.30
Block ../../Applications/Metrology/Water/GenesisFlow/objects/genesisflow
Id 0x0F, CRC16 0xA3A6, size 25164 bytes, version 3.02
Block ../../Applications/Customer/GenesisDefault/objects/customer
Id 0x09, CRC16 0xD56D, size 6196 bytes, version 1.59
Block ../../Applications/MetrologyAssistant/objects/assistant
Id 0x12, CRC16 0x9BA6, size 7948 bytes, version 1.13
Block ../../Applications/Communications/IrDA/objects/irda
Id 0x14, CRC16 0x2EB1, size 23324 bytes, version 2.06
Block ../../Applications/Communications/NFC/objects/nfc
Id 0x15, CRC16 0x43F4, size 6808 bytes, version 0.59
Block ../../Applications/FlexNetVersion/objects/flexnetversion
Id 0x18, CRC16 0xB2D5, size 116 bytes, version 13.0B
Minimum supported core revision: "Cordonel 1.62"
Maximum supported core revision: "Cordonel 1.78"
@@ -0,0 +1,40 @@
Release summary for product 1.78
Block ./Zero/objects/zero
Id 0x00, CRC16 0x3828, size 37972 bytes, version 5.37
Block ../../Applications/PowerMon/objects/powermon
Id 0x01, CRC16 0xB16C, size 3112 bytes, version 0.70
Block ../../Applications/ConfigExchange/objects/configex
Id 0x04, CRC16 0x8290, size 7944 bytes, version 2.38
Block ../../Applications/Logger/objects/logger
Id 0x08, CRC16 0x12D4, size 3972 bytes, version 0.18
Block ../../Applications/Metrology/Water/GenesisFlow/objects/genesisflow
Id 0x0F, CRC16 0x8228, size 23300 bytes, version 2.87
Block ../../Applications/MetrologyAssistant/objects/assistant
Id 0x12, CRC16 0x9BA6, size 7948 bytes, version 1.13
Block ../../Applications/Customer/GenesisDefault/objects/customer
Id 0x09, CRC16 0xD56D, size 6196 bytes, version 1.59
Block ../../Applications/Communications/IrDA/objects/irda
Id 0x14, CRC16 0x2EB1, size 23324 bytes, version 2.06
Block ../../Applications/Communications/NFC/objects/nfc
Id 0x15, CRC16 0x25B6, size 6824 bytes, version 0.61
Block ../../Applications/FlexNetVersion/objects/flexnetversion
Id 0x18, CRC16 0xE953, size 116 bytes, version 13.F3
Block ../../Applications/Communications/SensusRFRadio/objects/SensusRF
Id 0x10, CRC16 0x8261, size 93424 bytes, version 5.25
Block ../../Applications/PeriodicLogging/objects/periodiclog
Id 0x11, CRC16 0x5796, size 12412 bytes, version 0.75
Minimum supported core revision: "Cordonel 1.62"
Maximum supported core revision: "Cordonel 1.78"
@@ -0,0 +1,43 @@
Release summary for product 1.75
Block ./Zero/objects/zero
Id 0x00, CRC16 0x43E2, size 37948 bytes, version 5.33
Block ../../Applications/PowerMon/objects/powermon
Id 0x01, CRC16 0x2527, size 3068 bytes, version 0.68
Block ../../Applications/ConfigExchange/objects/configex
Id 0x04, CRC16 0x73BF, size 7940 bytes, version 2.35
Block ../../Applications/Logger/objects/logger
Id 0x08, CRC16 0x12D4, size 3972 bytes, version 0.18
Block ../../Applications/Metrology/Water/GenesisFlow/objects/genesisflow
Id 0x0F, CRC16 0x3A55, CRC32 0xFBEE5A5E, size 25424 bytes, version 3.15
Block ../../Applications/MetrologyAssistant/objects/assistant
Id 0x12, CRC16 0xD466, size 7948 bytes, version 1.14
Block ../../Applications/Customer/GenesisDefault/objects/customer
Id 0x09, CRC16 0xDCD7, size 6468 bytes, version 1.57
Block ../../Applications/Communications/IrDA/objects/irda
Id 0x14, CRC16 0x2ACD, size 24108 bytes, version 2.10
Block ../../Applications/Communications/NFC/objects/nfc
Id 0x15, CRC16 0x43F4, size 6808 bytes, version 0.59
Block ../../Applications/FlexNetVersion/objects/flexnetversion
Id 0x18, CRC16 0x68A4, size 116 bytes, version 20.06
Block ../../Applications/Communications/FlexNetSerial/objects/flexnetserial
Id 0x1A, CRC16 0x7326, size 6180 bytes, version 0.20
Block ../../Applications/NA2WAlarms/objects/na2walarms
Id 0x17, CRC16 0x49D9, size 10264 bytes, version 1.02
Block ../../Applications/NA2WLogger/objects/NA2WLogger
Id 0x16, CRC16 0xC9EF, size 9712 bytes, version 1.99
Minimum supported core revision: "Cordonel 1.62"
Maximum supported core revision: "Cordonel 1.75"
@@ -0,0 +1,978 @@
using System;
using System.Collections.Generic;
using System.IO;
using System.Linq;
using System.Reflection;
using NCrunch.Framework;
using Xylem.Common.CommonCore.Consts;
using Xylem.Common.Hardware.WaterMeter.Genesis.Applications;
using Xylem.Common.Hardware.WaterMeter.Genesis.Applications.Const;
using Xylem.Common.Hardware.WaterMeter.Genesis.GenesisConfig;
using Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore;
using Xylem.Common.Hardware.WaterMeter.Genesis.GenesisFile;
using Xylem.Common.Hardware.WaterMeter.Genesis.Registers;
using Xylem.Common.Hardware.WaterMeter.Genesis.Registers.DataTypes;
using Xylem.Common.Logic.ProductionOrderCore.TestResults;
namespace Xylem.Common.Hardware.WaterMeter.Genesis.MockGenesis
{
/// <summary>
/// Mock Genesis for usage to simulate an original Genesis without any hardware:
/// - The communication will use buffers program internally instead a physical port,
/// - Login, Logout and all other operations will NOT use a database call.
/// </summary>
public class MockGenesis : GenesisMeter
{
#region -------------------------------- Properties -----------------------------------------------------------
/// <summary>
/// The application description file (ADF) will be used to install a simulated new firmware to
/// the mock Genesis
/// </summary>
private String _packageDescriptionFile = DefaultPackageDescriptionFile;
/// <summary>
/// The required mock firmware installation is based on the file application simulation an installation
/// based on the package description file.
/// </summary>
private List<FileApplications> _mockFw = new List<FileApplications>();
/// <summary>
/// A list of all config registers for debug.
/// </summary>
// ReSharper disable once CollectionNeverQueried.Local for DEBUG only
private readonly List<String> _configRegisterNames = new List<String>();
/// <summary>
/// A list of all FLASH registers for debug.
/// </summary>
// ReSharper disable once CollectionNeverQueried.Local for DEBUG only
private readonly List<String> _flashRegisterNames = new List<String>();
/// <summary>
/// Simulated permanent storage (FLASH memory) to keep the values set with store configuration.
/// </summary>
private readonly MeterRegisters _flashRegister = new MeterRegisters();
/// <summary>
/// A list of all known registers which do not return the written value.
/// EXAMPLES:
/// - SENSUSRADIO_SystemState writing 0xFF returns 0x02
/// - XXX_StoreConfiguration writing 0x01 returns 0x00
///
/// The registers can be fully qualified or contain a substring like _StoreConfiguration if it always
/// returns an identical reply!
///
/// The first value is the expected value which will be searched for and the second value is the reply!
/// Only it the first value is exact as described here the reply is going to be changed.
///
/// </summary>
private static readonly List<RecoveryRegisterItem> SpecialRegisterReplies = new List<RecoveryRegisterItem>
{
// (partial) name expected value reply value
new RecoveryRegisterItem("SENSUSRADIO_SystemState", new Byte[]{0xFF}, new Byte[]{0x02}),
new RecoveryRegisterItem("_StoreCalibration", new Byte[]{0x01}, new Byte[]{0x00}),
new RecoveryRegisterItem("_StoreConfiguration", new Byte[]{0x01}, new Byte[]{0x00})
};
/// <summary>
/// The root path for all mock FwPackaged.
/// </summary>
private const String RootMockFwPath = "MockFwExamples";
/// <summary>
/// Mock object can overwrite PcbId for test purposes and set password to null to avoid
/// usage of wrong password and lock of the device trying to log in with the wrong password
/// </summary>
public new String PcbId
{
set
{
base.PcbId = value;
ClearPassword();
}
get => base.PcbId;
}
/// <summary>
/// Mock object can overwrite LutCrc for test purposes
/// </summary>
public new String LutCrc
{
set => base.LutCrc = value;
get => base.LutCrc;
}
/// <summary>
/// Mock object can overwrite StrCoreRevision for test purposes
/// </summary>
public new String StrCoreRevision
{
set => base.StrCoreRevision = value;
get => base.StrCoreRevision;
}
/// <summary>
/// Mock object can overwrite CoreRevision for test purposes
/// </summary>
public new Int32? CoreRevision
{
set => base.CoreRevision = value;
get => base.CoreRevision;
}
/// <summary>
/// Mock object can overwrite RadioFrequencyMhz for test purposes
/// </summary>
public new Int32? RadioFrequencyMhz
{
set => base.RadioFrequencyMhz = value;
get => base.RadioFrequencyMhz;
}
/// <summary>
/// Mock object can overwrite InstalledFwVersion for test purposes
/// </summary>
public new UInt32? InstalledFwVersion
{
set => base.InstalledFwVersion = value;
get => base.InstalledFwVersion;
}
/// <summary>
/// Mock object can overwrite Region for test purposes
/// </summary>
public new String Region
{
set => base.Region = value;
get => base.Region;
}
/// <summary>
/// Mock object can overwrite MeterSize for test purposes
/// </summary>
public new String MeterSize
{
set => base.MeterSize = value;
get => base.MeterSize;
}
/// <summary>
/// Mock object can overwrite FwVersion for test purposes
/// </summary>
public new String FwVersion
{
private set => base.FwVersion = value;
get => base.FwVersion;
}
/// <summary>
/// Mock object can overwrite login status for test purposes
/// </summary>
public new Boolean IsLoggedOn
{
set => base.IsLoggedOn = value;
get => base.IsLoggedOn;
}
/// <summary>
/// The exec path of the assembly for debug in environment.
/// </summary>
private readonly String _assemblyExecRootPath = Path.GetDirectoryName(Assembly.GetExecutingAssembly().Location);
/// <summary>
/// Fw package path relative to solution main folder.
/// </summary>
private readonly String _mockFwPackageRootPath;
#endregion ----------------------------- Properties -----------------------------------------------------------
#region --------------------------------- Default package description file ------------------------------------
/// <summary>
/// This file will be used to assign the default MeterApplications as simulated installation to the Genesis
/// meter. It contains only the important information:
/// - Each line starting with "Id" is an App,
/// - the "Maximum supported core revision" will be used as CoreRevision.
/// </summary>
private const String DefaultPackageDescriptionFile =
"Id 0x00, CRC16 0x39A8, size 37972 bytes, version 5.37\r\n" +
"Id 0x01, CRC16 0xB16C, size 3112 bytes, version 0.70\r\n" +
"Id 0x04, CRC16 0x8290, size 7944 bytes, version 2.38\r\n" +
"Id 0x08, CRC16 0x12D4, size 3972 bytes, version 0.18\r\n" +
"Id 0x11, CRC16 0x5796, size 12412 bytes, version 0.75\r\n" +
"Id 0x10, CRC16 0x0704, size 93488 bytes, version 5.30\r\n" +
"Id 0x0F, CRC16 0xA3A6, size 25164 bytes, version 3.02\r\n" +
"Id 0x09, CRC16 0xD56D, size 6196 bytes, version 1.59\r\n" +
"Id 0x12, CRC16 0x9BA6, size 7948 bytes, version 1.13\r\n" +
"Id 0x14, CRC16 0x2EB1, size 23324 bytes, version 2.06\r\n" +
"Id 0x15, CRC16 0x43F4, size 6808 bytes, version 0.59\r\n" +
"Id 0x18, CRC16 0xB2D5, size 116 bytes, version 13.0B\r\n" +
"Maximum supported core revision: \"Cordonel 1.78\"";
#endregion ------------------------------ Default package description file ------------------------------------
#region -------------------------------- Class handling -------------------------------------------------------
/// <summary>
/// Standard Ctor
/// </summary>
public MockGenesis()
{
var subFolder = Path.Combine("Hardware", "WaterMeter", "Genesis", "MockGenesis");
var solutionPath = "";
if (NCrunchEnvironment.NCrunchIsResident())
{
solutionPath = NCrunchEnvironment.GetOriginalSolutionPath().Replace("Common.sln", "");
}
else
{
if (_assemblyExecRootPath != null)
{
// We are in the Unit test folder "..\Common\Production\ProductionUiCordonel.UnitTests\bin\Debug"
// and need to go back to "..\Common"
var directoryInfo = Directory.GetParent(_assemblyExecRootPath)?.Parent?.Parent?.Parent?.Parent;
if (directoryInfo != null)
{
solutionPath = directoryInfo.FullName;
}
}
}
_mockFwPackageRootPath = Path.Combine(solutionPath, subFolder, "MockFwExamples");
Console.WriteLine($@"MOCK GENESIS: Search path for MockFwExamples: {_mockFwPackageRootPath}");
}
#endregion
#region -------------------------------- Firmware update and modification -------------------------------------
/// <summary>
/// Install a new firmware to the mock with the package description file as serialized string
/// <see cref="DefaultPackageDescriptionFile"/> which is reduced to the important lines or alternative
/// a named FW Version string like "R1.3.0B" or "R130B" which has to be part of the MockFwExamples.
///
/// The filters to find the path in the root path is the region and FW release version
/// "EMEA" or "NA"
/// "R130B" or "R1.3.0B"
/// additional naming is allowed (e.g. "EMEA_R13F3_replaces_R1107_R1108")
///
/// The filters to accept the file is:
/// "product" and
/// ".txt"
/// additional naming is allowed (e.g. "rowproduct_R130B.txt")
///
/// The FW root path is the path where the FW update packages are stored.
/// All files needed to be stored directly in the main folder of the FW version:
///
/// EXAMPLE:
/// [Root path]\EMEA_R130B\rowproduct_xyz.txt (package description file, mandatory is "product" and ".txt")
/// \configuration.json
/// \binfile00_0537_xyz.bin (package description file, mandatory is "binfile" and ".bin")
/// \binfile01_0070_xyz.bin
/// \...
/// \binfile18_130B_xyz.bin
/// [Root path]\NA_R2006 \naproduct_xyz.txt (package description file, mandatory is "product" and ".txt")
/// \configuration.json
/// \binfile00_0533_xyz.bin (package description file, mandatory is "binfile" and ".bin")
/// \binfile01_0068_xyz.bin
/// \...
/// \binfile18_2006_xyz.bin
///
/// </summary>
/// <param name="packageDescriptionFile"></param>
/// <param name="fwName">if this is null, the description file will be installed</param>
/// <remarks date="2024-Dec-02" author="Thomas Wiedebusch">
/// - Initial
/// </remarks>
/// <remarks date="2024-Dec-12" author="Thomas Wiedebusch">
/// - Logout, clear FLASH, login.
/// </remarks>
/// <remarks date="2024-Dec-18" author="Thomas Wiedebusch">
/// - Take FW version from MockFwExamples if explicit named with the release string.
/// </remarks>
/// <remarks date="2024-Dec-19" author="Thomas Wiedebusch">
/// - Returns bool.
/// </remarks>
public Boolean InstallNewMockFw(String packageDescriptionFile = null, String fwName = null)
{
if (fwName != null)
{
var releaseName = FwVersion.Replace(".", "");
if (!FwVersion.Equals(fwName) && !releaseName.Contains(fwName))
{
//Load new rawproduct.txt or naproduct.txt and install it to MockGenesis
if (!MeterFwUpdate.LoadPackageFile(_mockFwPackageRootPath, fwName, out _packageDescriptionFile))
return false;
}
}
else if (packageDescriptionFile != null)
{
// Set the new package file which will be parsed and used as simulation for all installed
// applications
_packageDescriptionFile = packageDescriptionFile;
}
else
{
return false;
}
Logout();
_flashRegister.MeterRegisterDic.Clear();
_flashRegisterNames.Clear();
// Force re-generation of the meter app and config register lists
MeterAppListVersion.Clear();
ConfigRegister.MeterRegisterDic.Clear();
ConfigApplications.Clear();
// Login to build initial registers being able to use the FLASH register dictionary immediately.
Login();
return RebootGenesis() == StatusReturn.Okay;
}
/// <summary>
/// Prepare the mock installed firmware by parsing the package description file.
/// </summary>
/// <remarks date="2024-Dec-01" author="Thomas Wiedebusch">
/// - Initial
/// </remarks>
private void ParsePackageDescriptionFile()
{
if (string.IsNullOrEmpty(_packageDescriptionFile))
return;
if (_mockFw == null)
_mockFw = new List<FileApplications>();
_mockFw.Clear();
MeterFwUpdate.GetPackageFileApplications(_packageDescriptionFile, _mockFw);
CoreRevision = MeterFwUpdate.GetCoreRevisionMax(_packageDescriptionFile);
if (CoreRevision != null)
StrCoreRevision = BuildFwVersionStringFromDec(CoreRevision);
}
/// <summary>
/// Modify or erase one mock app to simulate an application error of the firmware package.
/// This will be used for test purposes to manually change installed app-properties.
///
/// REMIND: All Apps are required to stay in MeterAppListVersion as this is a list of all Apps found in the
/// configuration.json. Does mean, for erasure just change the status to
/// <see cref="MeterAppState.MeterAppNotInstalled"/> !
///
/// </summary>
/// <param name="appId"></param>
/// <param name="version">null doesn't change actual version</param>
/// <param name="crc">null doesn't change actual CRC</param>
/// <param name="eraseApp"></param>
/// <returns>true if modification could be done</returns>
/// <remarks date="2024-Dec-04..05" author="Thomas Wiedebusch">
/// - Initial
/// </remarks>
public Boolean ModifyMockApp(Byte appId, UInt32? version = null, UInt16? crc = null, Boolean eraseApp = false)
{
if (MeterAppListVersion == null ||
MeterAppListVersion.Count == 0 ||
MeterAppListVersion.All(app => app.AppId != appId))
return false;
Logout();
foreach (var app in MeterAppListVersion.Where(app => app.AppId == appId))
{
if (eraseApp)
{
app.IsInstalled = false;
app.Status = MeterAppState.MeterAppNotInstalled;
app.StrVersion = "0.0";
app.Version = 0;
}
if (version != null)
{
app.Version = (UInt32)version;
app.StrVersion = BuildFwVersionStringFromDec((Int32?)version);
}
if (crc != null)
{
app.Crc = (UInt16)crc;
}
}
return true;
}
#endregion ----------------------------- Firmware update and modification -------------------------------------
#region -------------------------------- Mock Genesis Initialization ------------------------------------------
/// <summary>
/// Mock reading all applications from a predefined package description file instead from the Meter.
/// </summary>
/// <remarks date="2024-Dec-01" author="Thomas Wiedebusch">
/// - Initial
/// </remarks>
protected override void ReadMeterFirmwareAndAssignRegisters()
{
// Avoid overwriting of list if this already exits
if (MeterAppListVersion.Any() && MeterAppListVersion.All(f => f.Status != MeterAppState.Unknown))
{
Logger.Warn($"Slot:{Slot} - Trying to overwride installed FW. Skipping generation of new " +
"App list and meter register dictionary");
return;
}
// This loads the configuration.json from the exec directory
LoadConfiguration(Path.Combine(Path.GetDirectoryName(Assembly.GetExecutingAssembly().Location)));
// Simulate a firmware installation using the package description file to assign applications
ParsePackageDescriptionFile();
// Use the _mockFw created out of the package description file and which is a file application list
if (_mockFw == null || _mockFw.Count < MeterFwUpdate.MinAppsRequiredForOperation)
{
return;
}
//Get all existing applications from meter register dictionary
foreach (var meterApp in ConfigApplications.OrderBy(o => o.AppId))
{
// Take all listed config apps even if not installed
var app = new MeterApplications
{
AppId = meterApp.AppId,
Version = 0,
StrVersion = "0.00",
AppName = meterApp.AppName,
Crc = 0x0000,
Status = MeterAppState.MeterAppNotInstalled,
IsInstalled = false
};
foreach (var fileApp in _mockFw)
{
if (fileApp.AppId == meterApp.AppId)
{
app.Version = fileApp.Version;
app.StrVersion = fileApp.StrVersion;
app.Crc = fileApp.Crc;
app.Status = MeterAppState.MeterAppUpToDate;
app.IsInstalled = true;
}
// The FLEXNETVERSION is the overall firmware version
if (fileApp.AppId == MeterFwUpdate.FlexnetVersionAppId)
{
InstalledFwVersion = fileApp.Version;
FwVersion = fileApp.StrVersion;
}
}
MeterAppListVersion.Add(app);
}
try
{
// Initial list of ALL registers defined in configuration.json read from local bin directory
var tempConfigRegisters = ConfigRegister.MeterRegisterDic.ToList();
// Reduce registers to valid registers for a specific application with a specific version
// The old register dictionary is going to be cleared automatically calling this method.
BuildValidMeterRegisters(tempConfigRegisters);
// Fill the meter register dictionary with defaults are stored values in simulated FLASH memory
InitConfigAndFlashRegisters();
// Check for SENSUSRADIO as indication for region "EMEA", else it is regin "NA"
Region = "NA";
if (ConfigRegister.MeterRegisterDic.Any(app => app.Key.AppName.Equals("SENSUSRADIO")))
{
var value = ConfigRegister.Get("SENSUSRADIO_FrequencyIndicator");
if (value != null)
{
RadioFrequencyMhz = RegisterConverter.ByteArrayToValue<Int32>(value);
Region = "EMEA";
}
}
}
catch (Exception ex)
{
Logger.Error($"Slot:{Slot} - {ex.Message}");
}
}
/// <summary>
/// Use the app name to flash all contents:
/// - Take all values from RAM memory (config register dictionary) and copy it to FLASH memory (flash
/// register dictionary) which simulates the non-volatile memory of the Genesis.
/// </summary>
/// <param name="appName"></param>
/// <remarks date="2024-Dec-03" author="Thomas Wiedebusch">
/// - Initial.
/// </remarks>
private void FlashMemory(String appName)
{
if (_flashRegister == null || ConfigRegister == null)
{
return;
}
// Safe all data from config to FLASH register dictionary for App.
foreach (var reg in ConfigRegister.MeterRegisterDic)
{
try
{
var regName = reg.Key.GetIdent();
// Filter for all registers of a specific App
if (regName.Contains(appName))
{
// Avoid writing of NOT writable registers, only read write makes sense as others cannot be
// read back!
if (reg.Key.RegisterDetail.Privilege.Lvl8 == Access.RW &&
reg.Key.DataType != typeof(Rpc))
{
var flashData = ConfigRegister.Get(regName);
// Throws an exception if register doesn't exist, but we want to go ahead with the others
var regDef = _flashRegister.GetRegisterDefinitionByName(regName);
_flashRegister.Set(regDef, flashData);
}
}
}
catch (Exception ex)
{
Logger.Error($"Slot:{Slot} - {ex.Message}");
}
}
}
/// <summary>
/// Store one single parameter to flash memory to simulate FW internal change of register or the
/// "GENESISFLOW_StoreCalibration":
/// - Avoid to check of RO or WO to force an update as it would be done by the FW.
/// </summary>
/// <param name="regName"></param>
/// <remarks date="2024-Dec-07" author="Thomas Wiedebusch">
/// - Initial.
/// </remarks>
private void SingleParameterFlashMemory(String regName)
{
if (_flashRegister == null)
{
return;
}
try
{
var flashData = ConfigRegister.Get(regName);
// Throws an exception if register doesn't exist, but we want to go ahead with the others
var regDef = _flashRegister.GetRegisterDefinitionByName(regName);
_flashRegister.Set(regDef, flashData);
}
catch (Exception ex)
{
Logger.Error($"Slot:{Slot} - {ex.Message}");
}
}
/// <summary>
/// Fill the meter register dictionary with the stored values of the simulated FLASH memory:
/// - If FLASH memory register dictionary doesn't exist (initial start) generate a copy of
/// the config register dictionary and fill it with default values from configuration.json,
/// - Copy ALWAYS the content of the FLASH to the config register dictionary.
///
/// REMIND:
/// If an application has received a store configuration, the FLASH content will be overwritten
/// from default value to the actual value of the config register dictionary as this is the
/// temporary value (RAM simulation) of the Genesis.
///
/// </summary>
/// <remarks date="2024-Dec-03..10" author="Thomas Wiedebusch">
/// - Initial.
/// </remarks>
private void InitConfigAndFlashRegisters()
{
if (_flashRegister == null || ConfigRegister == null)
{
return;
}
_configRegisterNames.Clear();
// If the FLASH registers do not exist, create those and fill it with default values
if (_flashRegister.MeterRegisterDic.Count == 0)
{
foreach (var reg in ConfigRegister.MeterRegisterDic)
{
var regName = reg.Key.GetIdent();
_flashRegisterNames.Add(regName);
var regDef = ConfigRegister.GetRegisterDefinitionByName(regName);
// First clone entire register set to avoid exception if register is not available
_flashRegister.MeterRegisterDic.TryAdd(reg.Key, null);
// Avoid writing of NOT writable registers
if (reg.Key.RegisterDetail.Privilege.Lvl8 == Access.RW) // && reg.Key.DataType != typeof(Rpc))
{
// Add default value to FLASH register dictionary
RegisterConverter.SetToDefault(regDef, out var value);
_flashRegister.Set(regDef, value);
}
}
_flashRegisterNames.Sort();
}
// Preset at initial login after start or reboot all config registers with the FLASH register values.
// Those are set to default on initial start and after store configuration on a predefined value.
foreach (var reg in ConfigRegister.MeterRegisterDic)
{
try
{
var regName = reg.Key.GetIdent();
_configRegisterNames.Add(regName);
var regDef = ConfigRegister.GetRegisterDefinitionByName(regName);
// Avoid writing of NOT writable registers, only read write makes sense as others cannot be read
// back!
if (reg.Key.RegisterDetail.Privilege.Lvl8 == Access.RW) //&& reg.Key.DataType != typeof(Rpc))
{
var flashData = _flashRegister.Get(regName);
// Throws an exception if register doesn't exist, but we want to go ahead with the others
ConfigRegister.Set(regDef, flashData);
}
}
catch (Exception ex)
{
Logger.Error($"Slot:{Slot} - {ex.Message}");
}
_configRegisterNames.Sort();
}
}
#endregion ----------------------------- Mock Genesis Initialization ------------------------------------------
#region -------------------------------- Mock Genesis Simulation ----------------------------------------------
/// <inheritdoc />
/// <summary>
/// Simulate login to mock Genesis for test purposes
/// </summary>
/// <remarks date="2024-Nov-28" author="Thomas Wiedebusch">
/// - Initial.
/// </remarks>
public override Boolean Login()
{
ReadMeterFirmwareAndAssignRegisters();
IsLoggedOn = true;
return IsLoggedOn;
}
/// <inheritdoc />
/// <summary>
/// Simulate logout to mock Genesis for test purposes
/// </summary>
/// <remarks date="2024-Nov-28" author="Thomas Wiedebusch">
/// - Initial.
/// </remarks>
public override Boolean Logout()
{
IsLoggedOn = false;
return IsLoggedOn;
}
/// <inheritdoc />
/// <summary>
/// Simulate login with password to mock Genesis for test purposes
/// </summary>
/// <remarks date="2024-Nov-28" author="Thomas Wiedebusch">
/// - Initial.
/// </remarks>
public override Boolean Login(String password, Boolean runImmediately = true,
Boolean skipReadMeterFwAndAssignRegisters = false)
{
Password = password;
return Login();
}
/// <summary>
/// Mock Write Register:
/// - Optional: wait for result and validate.
/// </summary>
/// <typeparam name="T">Data type of Register</typeparam>
/// <param name="regName">Register to change</param>
/// <param name="value">Value to save</param>
/// <param name="waitForResult">wait until result is ready</param>
/// <param name="checkRegister">check the content of the register by read back</param>
/// <param name="skipRetryErrorCode">skip retries on this error code return</param>
/// <returns>true on successful operation</returns>
/// <remarks date="2024-Dec-02..03" author="Thomas Wiedebusch">
/// - Initial mock implementation.
/// </remarks>
/// <remarks date="2024-Dec-10" author="Thomas Wiedebusch">
/// - Capture "SYSTEM_TriggerUpgrade" to force a reboot and install the FW defined in the actual FW package
/// description file.
/// - Store calibration executed on calibration registers.
/// </remarks>
public override Boolean WriteRegister<T>(String regName, T value, Boolean waitForResult = true,
Boolean checkRegister = false, UInt16 skipRetryErrorCode = CommunicationConfig.SkipRetryErrorCode)
{
try
{
var regDef = ConfigRegister.GetRegisterDefinitionByName(regName);
var data = RegisterConverter.ValueToByteArray(value);
var hideDataInLog = regDef.RegisterName.Contains("EncryptionKey") ||
regDef.RegisterName.Contains("Password");
var rawMsg = RegisterConverter.GetRegisterRawText(regDef, data, hideDataInLog);
Logger.Info($"Slot:{Slot} - Write register({regDef.GetIdent()}), record({rawMsg})");
// Check for special response for predefined registers which reply with a changed
// parameter like SENSUSRADIO_SystemState set to 0xFF creates a reply of 0x02.
// This has to be done BEFORE ConfigRegister.Set!
CheckAndModifySpecialReplies(regName, data);
// Avoid writing of NOT writable registers and out of range of register value
if (!PreRegisterWrite(regDef, data))
return false;
// Throws an exception if register doesn't exist
ConfigRegister.Set(regDef, data);
// For mock simulation the write register is going to kick-off special activities
CheckSpecialActivities(regName, value);
// If no further action like check register or read-back is required, exit here with success
if (!waitForResult && !checkRegister)
{
return true;
}
// If register check by read back is not required we return the acknowledgment state
if (!checkRegister || regDef.RegisterDetail.Privilege.Lvl8 == Access.WO)
{
return true;
}
var readBackData = ReadRegister(regName, data.Length, skipRetryErrorCode);
if (readBackData == null)
return false;
// Check if register read was okay and read and written data are EQUAL
for (var i = 0; i < data.Length; i++)
{
if (readBackData[i] != data[i])
return false;
}
return true;
}
catch (Exception e)
{
Logger.Error($"Slot:{Slot} - {e.Message}");
}
return false;
}
/// <summary>
/// Check for special activities needed to execute on register write access:
/// - Store configuration to safe all values of a single App to the simulated FLASH memory,
/// - Store calibration stores all defined register <see cref="CalibrationResults.CalibrationRegisterNames"/>,
/// to the simulated FLASH memory,
/// - Trigger upgrade forces a reboot of the meter including a reload of all applications and regeneration of
/// all registers.
/// </summary>
/// <typeparam name="T"></typeparam>
/// <param name="regName"></param>
/// <param name="value"></param>
/// <remarks date="2024-Dec-10" author="Thomas Wiedebusch">
/// - Initial MockGenesis simulation.
/// </remarks>
private void CheckSpecialActivities<T>(String regName, T value)
{
// Capture "StoreConfiguration" to copy config register contents of App to FLASH
var searchString = "_StoreConfiguration";
if (regName.Contains(searchString))
{
var appName = regName.Replace(searchString, "");
FlashMemory(appName);
}
// Capture "StoreCalibration" to copy config register contents of App to FLASH
searchString = "GENESISFLOW_StoreCalibration";
if (regName.Contains(searchString))
{
// Store single parameter to FLASH
foreach (var registerName in CalibrationResults.CalibrationRegisterNames)
SingleParameterFlashMemory(registerName);
}
// Capture "UpgradePermissions" to copy config register contents of App to FLASH as
// SYSTEM doesn't have a "StoreConfiguration" command
searchString = "SYSTEM_UpgradePermissions";
if (regName.Contains(searchString))
{
SingleParameterFlashMemory(searchString);
}
// Capture "SYSTEM_TriggerUpgrade" to force a reboot and install the actual given firmware
// package description file as FW.
searchString = "SYSTEM_TriggerUpgrade";
if (regName.Equals(searchString) && typeof(T) == typeof(Boolean))
{
var forceTriggerUpgrade = (Boolean)Convert.ChangeType(value, typeof(Boolean));
if (forceTriggerUpgrade)
RebootGenesis();
}
}
/// <summary>
/// Check for special response for predefined registers which reply with a changed parameter like
/// SENSUSRADIO_SystemState set to 0xFF creates a reply of 0x02. This should simulate the real
/// GenesisMeter reply.
/// </summary>
/// <param name="regName"></param>
/// <param name="data"></param>
/// <remarks date="2024-Dec-10" author="Thomas Wiedebusch">
/// - Initial MockGenesis simulation.
/// </remarks>
private static void CheckAndModifySpecialReplies(String regName, Byte[] data)
{
if (SpecialRegisterReplies.Any(n => regName.Contains(n.RegisterIdent)))
{
foreach (var special in SpecialRegisterReplies.Where(special =>
regName.Contains(special.RegisterIdent)))
{
var retVal = true;
// Avoid buffer overflow
if (data.Length < special.ReadBackValue.Length)
break;
for (var i = 0; i < special.WriteValue.Length; i++)
{
// Check the required input which forces a change of the response
if (data[i] != special.WriteValue[i])
retVal = false;
}
if (!retVal)
break;
// Exchange the received value with the special reply
for (var i = 0; i < special.ReadBackValue.Length; i++)
{
data[i] = special.ReadBackValue[i];
}
}
}
}
/// <summary>
/// Mock Read Register and return byte array for test purposes stored in the config register dictionary.
/// </summary>
/// <param name="regName"></param>
/// <param name="expectedLength">expected length for response</param>
/// <param name="skipRetryErrorCode">skip retries on this error code return</param>
/// <returns></returns>
/// <remarks date="2024-Dec-02..03" author="Thomas Wiedebusch">
/// - Initial mock implementation.
/// </remarks>
public override Byte[] ReadRegister(String regName, Int32? expectedLength = null,
UInt16 skipRetryErrorCode = CommunicationConfig.SkipRetryErrorCode)
{
try
{
var regDef = ConfigRegister.GetRegisterDefinitionByName(regName);
var hideDataInLog = regDef.RegisterName.Contains("EncryptionKey");
// Avoid reading of NOT readable registers
if (regDef.RegisterDetail.Privilege.Lvl8 != Access.RW &&
regDef.RegisterDetail.Privilege.Lvl8 != Access.RO)
return null;
var result = ConfigRegister.Get(regName);
// Avoid access of not present register
if (result == null)
{
Logger.Error($"Slot:{Slot} - Read register({regDef.GetIdent()}) returns value (null)");
return null;
}
var rawMsg = RegisterConverter.GetRegisterRawText(regDef, result, hideDataInLog);
Logger.Info($"Slot:{Slot} - Read register({regDef.GetIdent()}), record({rawMsg})");
return result;
}
catch (Exception e)
{
Logger.Error($"Slot:{Slot} - {e.Message}");
}
return null;
}
/// <summary>
/// The simulation of the Genesis reboot:
/// - Login to create the actual installed
/// Kill all old applications,
/// this will force a regeneration of a valid application list and config register dictionary!
/// This will include the copy of FLASH register values or defaults to the config meter dictionary.
/// </summary>
/// <returns></returns>
/// <remarks date="2024-Dec-03" author="Thomas Wiedebusch">
/// - Initial.
/// </remarks>
/// <remarks date="2024-Dec-07" author="Thomas Wiedebusch">
/// - Reboot count used to check for success of reboot.
/// </remarks>
/// <remarks date="2024-Dec-11..12" author="Thomas Wiedebusch">
/// - Prepared to override the Genesis reboot used in <see cref="MeterResetPsu"/>.
/// </remarks>
public override StatusReturn RebootGenesis()
{
// ReLogin to build initial registers if it has not been performed in advance
ReLogin();
const String registerName = "CUSTOMER_RebootCount";
var rebootCountBeforeReboot = RegisterConverter.ByteArrayToValue<UInt32>(ReadRegister(registerName));
// Simulate reboot execution by increasing the reboot count by one
rebootCountBeforeReboot++;
if (WriteRegister(registerName, rebootCountBeforeReboot))
{
SingleParameterFlashMemory(registerName);
}
// Kill all old applications to force a regeneration of a valid application list
// and config register dictionary!
Logout();
FwVersion = "";
InstalledFwVersion = 0;
Region = "";
RadioFrequencyMhz = null;
MeterAppListVersion.Clear();
ConfigRegister.MeterRegisterDic.Clear();
ConfigApplications.Clear();
// Login to build initial registers if it has not been performed in advance
Login();
var rebootCountAfterReboot = RegisterConverter.ByteArrayToValue<UInt32>(ReadRegister(registerName));
return rebootCountAfterReboot == rebootCountBeforeReboot ? StatusReturn.Okay : StatusReturn.Failed;
}
/// <summary>
/// Clear the config registers to simulate an invalid load or invalid configuration.json
/// </summary>
/// <remarks date="2025-Feb-17" author="Thomas Wiedebusch">
/// - Initial.
/// </remarks>
public void KillConfigRegisters()
{
ConfigRegister.MeterRegisterDic.Clear();
}
#endregion ----------------------------- Mock Genesis simulation ----------------------------------------------
}
}
@@ -0,0 +1,94 @@
<?xml version="1.0" encoding="utf-8"?>
<Project ToolsVersion="15.0" xmlns="http://schemas.microsoft.com/developer/msbuild/2003">
<Import Project="$(MSBuildExtensionsPath)\$(MSBuildToolsVersion)\Microsoft.Common.props" Condition="Exists('$(MSBuildExtensionsPath)\$(MSBuildToolsVersion)\Microsoft.Common.props')" />
<PropertyGroup>
<Configuration Condition=" '$(Configuration)' == '' ">Debug</Configuration>
<Platform Condition=" '$(Platform)' == '' ">AnyCPU</Platform>
<ProjectGuid>{D7A7E1FF-D024-407F-B30D-4C519CFA7BF1}</ProjectGuid>
<OutputType>Library</OutputType>
<AppDesignerFolder>Properties</AppDesignerFolder>
<RootNamespace>Xylem.Common.Hardware.WaterMeter.Genesis.MockGenesis</RootNamespace>
<AssemblyName>Xylem.Common.Hardware.WaterMeter.Genesis.MockGenesis</AssemblyName>
<TargetFrameworkVersion>v4.8.1</TargetFrameworkVersion>
<FileAlignment>512</FileAlignment>
<Deterministic>true</Deterministic>
<TargetFrameworkProfile />
</PropertyGroup>
<PropertyGroup Condition=" '$(Configuration)|$(Platform)' == 'Debug|AnyCPU' ">
<DebugSymbols>true</DebugSymbols>
<DebugType>full</DebugType>
<Optimize>false</Optimize>
<OutputPath>bin\Debug\</OutputPath>
<DefineConstants>DEBUG;TRACE</DefineConstants>
<ErrorReport>prompt</ErrorReport>
<WarningLevel>4</WarningLevel>
</PropertyGroup>
<PropertyGroup Condition=" '$(Configuration)|$(Platform)' == 'Release|AnyCPU' ">
<DebugType>pdbonly</DebugType>
<Optimize>true</Optimize>
<OutputPath>bin\Release\</OutputPath>
<DefineConstants>TRACE</DefineConstants>
<ErrorReport>prompt</ErrorReport>
<WarningLevel>4</WarningLevel>
</PropertyGroup>
<ItemGroup>
<Reference Include="NCrunch.Framework, Version=5.11.0.0, Culture=neutral, PublicKeyToken=01d101bf6f3e0aea, processorArchitecture=MSIL">
<HintPath>..\..\..\..\packages\NCrunch.Framework.5.11.0\lib\net35\NCrunch.Framework.dll</HintPath>
</Reference>
<Reference Include="NLog, Version=5.0.0.0, Culture=neutral, PublicKeyToken=5120e14c03d0593c, processorArchitecture=MSIL">
<HintPath>..\..\..\..\packages\NLog.5.2.2\lib\net46\NLog.dll</HintPath>
</Reference>
<Reference Include="System" />
<Reference Include="System.Configuration" />
<Reference Include="System.Core" />
<Reference Include="System.IO.Compression" />
<Reference Include="System.Xml.Linq" />
<Reference Include="System.Data.DataSetExtensions" />
<Reference Include="Microsoft.CSharp" />
<Reference Include="System.Data" />
<Reference Include="System.Net.Http" />
<Reference Include="System.Xml" />
</ItemGroup>
<ItemGroup>
<Compile Include="MockGenesis.cs" />
<Compile Include="Properties\AssemblyInfo.cs" />
</ItemGroup>
<ItemGroup>
<ProjectReference Include="..\..\..\..\CommonCore\CommonCore.csproj">
<Project>{1B02C79E-0B19-43E2-8F6B-71EF0C786C97}</Project>
<Name>CommonCore</Name>
</ProjectReference>
<ProjectReference Include="..\..\..\..\Logic\ProductionOrderCore\ProductionOrderCore.csproj">
<Project>{6D2777BB-7A88-466D-A49B-3266F9BF0160}</Project>
<Name>ProductionOrderCore</Name>
</ProjectReference>
<ProjectReference Include="..\..\WaterMeterCore\WaterMeterRegisters\WaterMeterRegisters.csproj">
<Project>{26AFCF1E-1287-48B8-A506-32B1E8A0DD0E}</Project>
<Name>WaterMeterRegisters</Name>
</ProjectReference>
<ProjectReference Include="..\Applications\Applications.csproj">
<Project>{315e94b8-b82f-4b25-b5bd-297df3bc1d54}</Project>
<Name>Applications</Name>
</ProjectReference>
<ProjectReference Include="..\GenesisConfig\GenesisConfig.csproj">
<Project>{F013A56B-7BE6-4852-9CD8-B971CD1ADD0C}</Project>
<Name>GenesisConfig</Name>
</ProjectReference>
<ProjectReference Include="..\GenesisCore\GenesisCore.csproj">
<Project>{04201E95-90A0-4B73-A72F-379739B2A3AE}</Project>
<Name>GenesisCore</Name>
</ProjectReference>
<ProjectReference Include="..\GenesisFile\GenesisFile.csproj">
<Project>{2C6378C6-6BA1-4CEE-8992-8404D8369A90}</Project>
<Name>GenesisFile</Name>
</ProjectReference>
<ProjectReference Include="..\Registers\Registers.csproj">
<Project>{F4AAF7E6-7333-4284-B735-E32DEB076C64}</Project>
<Name>Registers</Name>
</ProjectReference>
</ItemGroup>
<ItemGroup>
<None Include="packages.config" />
</ItemGroup>
<Import Project="$(MSBuildToolsPath)\Microsoft.CSharp.targets" />
</Project>
@@ -0,0 +1,5 @@
<ProjectConfiguration>
<Settings>
<HiddenComponentWarnings />
</Settings>
</ProjectConfiguration>
@@ -0,0 +1,103 @@
[
//Content missing CSD parameters to force a failure for register-restorer
{
"RegisterName": "SENSUSRADIO_RadioAddress",
"RegisterValue": "GI6fMA==",
"Source": 0
},
{
"RegisterName": "SENSUSRADIO_EncryptionKey",
"RegisterValue": "Dp+sxqDh7xw7J6SbrCFlNQ==",
"Source": 0
},
{
"RegisterName": "GENESISFLOW_MeterSize",
"RegisterValue": "AAAAAQ==",
"Source": 0
},
{
"RegisterName": "GENESISFLOW_DisplayUnits",
"RegisterValue": "AAAAAA==",
"Source": 0
},
{
"RegisterName": "METROLOGYASST_FlowUnits",
"RegisterValue": "AAAABA==",
"Source": 0
},
{
"RegisterName": "SENSUSRADIO_FrequencyIndicator",
"RegisterValue": "AAABsQ==",
"Source": 0
},
{
"RegisterName": "METROLOGYASST_PulseMode",
"RegisterValue": "AAAABQ==",
"Source": 0
},
{
"RegisterName": "METROLOGYASST_PulseLength",
"RegisterValue": "AAAACA==",
"Source": 0
},
{
"RegisterName": "METROLOGYASST_PressurePresent",
"RegisterValue": "AAAAAA==",
"Source": 0
},
{
"RegisterName": "METROLOGYASST_TemperatureUnits",
"RegisterValue": "AAAAAA==",
"Source": 0
},
{
"RegisterName": "METROLOGYASST_PressureRate",
"RegisterValue": "AAAAAA==",
"Source": 0
},
{
"RegisterName": "METROLOGYASST_PressureUnits",
"RegisterValue": "AAAAAA==",
"Source": 0
},
{
"RegisterName": "METROLOGYASST_PulseWeight",
"RegisterValue": "ADDUAA==",
"Source": 0
},
{
"RegisterName": "SENSUSRADIO_MbusState",
"RegisterValue": "AAAABw==",
"Source": 0
},
{
"RegisterName": "SENSUSRADIO_OmTxInterval",
"RegisterValue": "AAAOEA==",
"Source": 0
},
{
"RegisterName": "SENSUSRADIO_TxInterval",
"RegisterValue": "AAAADw==",
"Source": 0
},
{
"RegisterName": "SENSUSRADIO_WakeupInterval",
"RegisterValue": "AAAAAw==",
"Source": 0
},
{
"RegisterName": "SENSUSRADIO_LatInterval",
"RegisterValue": "AAAAAw==",
"Source": 0
},
{
"RegisterName": "GENESISFLOW_DisplayPow10",
"RegisterValue": "/f///w==",
"Source": 0
},
{
"RegisterName": "METROLOGYASST_FlowPoint",
"RegisterValue": "AgAAAA==",
"Source": 0
}
]
File diff suppressed because one or more lines are too long
File diff suppressed because one or more lines are too long
@@ -0,0 +1 @@
[{"RegisterName":"GENESISFLOW_MeterSize","RegisterValue":"AAAACw==","Source":0},{"RegisterName":"GENESISFLOW_DisplayUnits","RegisterValue":"AAAAAg==","Source":0},{"RegisterName":"METROLOGYASST_FlowUnits","RegisterValue":"AAAABg==","Source":0},{"RegisterName":"METROLOGYASST_PulseMode","RegisterValue":"AAAABQ==","Source":0},{"RegisterName":"METROLOGYASST_PulseLength","RegisterValue":"AAAACA==","Source":0},{"RegisterName":"METROLOGYASST_PressurePresent","RegisterValue":"AAAAAQ==","Source":0},{"RegisterName":"METROLOGYASST_TemperatureUnits","RegisterValue":"AAAAAQ==","Source":0},{"RegisterName":"METROLOGYASST_PressureRate","RegisterValue":"AADqYA==","Source":0},{"RegisterName":"METROLOGYASST_PressureUnits","RegisterValue":"AAAAAA==","Source":0},{"RegisterName":"GENESISFLOW_ForwardArrow","RegisterValue":"AAAAAA==","Source":0},{"RegisterName":"METROLOGYASST_PulseWeight","RegisterValue":"ABJ7ww==","Source":0},{"RegisterName":"GENESISFLOW_DisplayPow10","RegisterValue":"/////w==","Source":0},{"RegisterName":"METROLOGYASST_FlowPoint","RegisterValue":"AwAAAA==","Source":0},{"RegisterName":"CUSTOMER_AlarmEnableMask","RegisterValue":"AAAAAA==","Source":1},{"RegisterName":"GENESISFLOW_LowFlowThreshold","RegisterValue":"AAAAyA==","Source":1},{"RegisterName":"GENESISFLOW_LowFlowMaxPeriod","RegisterValue":"ADwAAA==","Source":1},{"RegisterName":"GENESISFLOW_Timeout","RegisterValue":"AAE=","Source":1},{"RegisterName":"GENESISFLOW_MinValidToF","RegisterValue":"ANG3Fw==","Source":1},{"RegisterName":"GENESISFLOW_MinValidAmplitude","RegisterValue":"JYAAAA==","Source":1},{"RegisterName":"GENESISFLOW_MaxValidToF","RegisterValue":"AXl8ww==","Source":1},{"RegisterName":"GENESISFLOW_MaxValidDeltaToF","RegisterValue":"ABxPvg==","Source":1},{"RegisterName":"GENESISFLOW_MaxValidAmplitude","RegisterValue":"rwAAAA==","Source":1},{"RegisterName":"CUSTOMER_PressureLowDelay","RegisterValue":"AAAAPA==","Source":1},{"RegisterName":"CUSTOMER_PressureLowThreshold","RegisterValue":"AAOpgA==","Source":1},{"RegisterName":"CUSTOMER_PressureHighDelay","RegisterValue":"AAAAPA==","Source":1},{"RegisterName":"CUSTOMER_PressureHighThreshold","RegisterValue":"ABUOoA==","Source":1},{"RegisterName":"CUSTOMER_TemperatureLowDelay","RegisterValue":"AAAAPA==","Source":1},{"RegisterName":"CUSTOMER_TemperatureLowThreshold","RegisterValue":"AAAAFA==","Source":1},{"RegisterName":"CUSTOMER_TemperatureHighDelay","RegisterValue":"AAAAPA==","Source":1},{"RegisterName":"CUSTOMER_TemperatureHighThreshold","RegisterValue":"AAABDg==","Source":1},{"RegisterName":"CUSTOMER_ExcessFlowVolumeThreshold","RegisterValue":"APQkAA==","Source":1},{"RegisterName":"CUSTOMER_ExcessFlowTimeThreshold","RegisterValue":"AAAABQ==","Source":1},{"RegisterName":"CUSTOMER_LeakTimeThreshold","RegisterValue":"AAAQ4A==","Source":1},{"RegisterName":"CUSTOMER_LeakFlowThreshold","RegisterValue":"AAF3AA==","Source":1},{"RegisterName":"GENESISFLOW_LedMode","RegisterValue":"AAAAAA==","Source":1},{"RegisterName":"GENESISFLOW_ForwardArrow","RegisterValue":"AAAAAQ==","Source":1},{"RegisterName":"GENESISFLOW_SampleRate","RegisterValue":"AAI=","Source":1},{"RegisterName":"POWERMON_BatteryQuantity","RegisterValue":"AAAAAg==","Source":1},{"RegisterName":"SYSTEM_UpgradePermissions","RegisterValue":"AAAA/w==","Source":1},{"RegisterName":"POWERMON_WarnFromClamp","RegisterValue":"JZgGAA==","Source":1},{"RegisterName":"METROLOGYASST_TemperatureUnits","RegisterValue":"AAAAAQ==","Source":1},{"RegisterName":"CUSTOMER_ReverseFlowTimeThreshold","RegisterValue":"AAAAPA==","Source":1},{"RegisterName":"CUSTOMER_AlarmVisualMask","RegisterValue":"AAAAAA==","Source":1},{"RegisterName":"CUSTOMER_AlarmBroadcastMask","RegisterValue":"AAAAAA==","Source":1},{"RegisterName":"IRDA_AdapterPresenceLimit","RegisterValue":"AAM=","Source":1},{"RegisterName":"CUSTOMER_RebootCount","RegisterValue":"AAAAAA==","Source":1},{"RegisterName":"METROLOGYASST_PressureUnits","RegisterValue":"AAE=","Source":1},{"RegisterName":"GENESISFLOW_ArrowThreshold","RegisterValue":"AAAAAA==","Source":1},{"RegisterName":"METROLOGYASST_PressureRate","RegisterValue":"AADqYA==","Source":1},{"RegisterName":"CUSTOMER_InstallationTime","RegisterValue":"AAAAAA==","Source":1},{"RegisterName":"GENESISFLOW_MaxDeltaToFRange","RegisterValue":"AAIY3g==","Source":1},{"RegisterName":"GENESISFLOW_MaxDeltaToFDeviation","RegisterValue":"AAGtfw==","Source":1},{"RegisterName":"GENESISFLOW_StartHit","RegisterValue":"AAAABg==","Source":1},{"RegisterName":"METROLOGYASST_PulseEvenDistribution","RegisterValue":"AA==","Source":1}]
@@ -0,0 +1,36 @@
using System.Reflection;
using System.Runtime.CompilerServices;
using System.Runtime.InteropServices;
// General Information about an assembly is controlled through the following
// set of attributes. Change these attribute values to modify the information
// associated with an assembly.
[assembly: AssemblyTitle("Xylem.Common.Hardware.WaterMeter.Genesis.MockGenesis")]
[assembly: AssemblyDescription("")]
[assembly: AssemblyConfiguration("")]
[assembly: AssemblyCompany("Xylem")]
[assembly: AssemblyProduct("MockGenesis")]
[assembly: AssemblyCopyright("Copyright © Xylem 2024")]
[assembly: AssemblyTrademark("")]
[assembly: AssemblyCulture("")]
// Setting ComVisible to false makes the types in this assembly not visible
// to COM components. If you need to access a type in this assembly from
// COM, set the ComVisible attribute to true on that type.
[assembly: ComVisible(false)]
// The following GUID is for the ID of the typelib if this project is exposed to COM
[assembly: Guid("d7a7e1ff-d024-407f-b30d-4c519cfa7bf1")]
// Version information for an assembly consists of the following four values:
//
// Major Version
// Minor Version
// Build Number
// Revision
//
// You can specify all the values or you can default the Build and Revision Numbers
// by using the '*' as shown below:
// [assembly: AssemblyVersion("1.0.*")]
[assembly: AssemblyVersion("1.0.0.0")]
[assembly: AssemblyFileVersion("1.0.0.0")]
@@ -0,0 +1,5 @@
<?xml version="1.0" encoding="utf-8"?>
<packages>
<package id="NCrunch.Framework" version="5.11.0" targetFramework="net481" />
<package id="NLog" version="5.2.2" targetFramework="net48" />
</packages>
@@ -130,7 +130,7 @@ namespace Xylem.Common.Hardware.WaterMeter.WaterMeterCore
Boolean Login();
/// <summary>
/// Start Login with out password service and a fixed password
/// Start Login without password service and a fixed password
/// </summary>
/// <param name="password">password for login</param>
/// <param name="runImmediately">execute immediately</param>
@@ -209,9 +209,7 @@ namespace Xylem.Common.Hardware.WaterMeter.WaterMeterCore
void StartCalibration();
/// <summary>
/// Meter must have a active for calibration <see />
/// Stop receive record from meter, decode and store record
/// record will not calculate or store
/// Meter must have an active Stop Record for calibration
/// </summary>
void StopCalibration();
@@ -282,6 +280,10 @@ namespace Xylem.Common.Hardware.WaterMeter.WaterMeterCore
/// Clear all object set up on runtime
/// </summary>
void DisposeMeter();
/// <summary>
/// Dispose the entire test bench
/// </summary>
void TestBenchDispose();
}
}
@@ -0,0 +1,287 @@
using System;
using System.Collections.Generic;
using System.Runtime.InteropServices;
using Xylem.Common.Hardware.WaterMeter.WaterMeterCore.Consts;
using Xylem.Common.Metrology.Measurements;
using Xylem.Common.Metrology.Measurements.Consts;
namespace Xylem.Common.Hardware.WaterMeter.WaterMeterCore
{
/// <inheritdoc />
/// <summary>
/// IMeter is the highest level interface between a meter with direct communication to a test bench.
/// has general things like calibration, measurement and set up routines.
/// no specific meter stuff in here!
/// it is always disposable
/// </summary>
[Guid("7BD20046-DF8C-44A6-8F6B-687FAA26FA71")
, ComVisible(true)
, InterfaceType(ComInterfaceType.InterfaceIsIDispatch)]
public interface IMeter : IDisposable
{
#region events
/// <summary>
/// occurs when ProcessState has changed
/// </summary>
event EventHandler OnProcessStatusChanged;
/// <summary>
/// occurs when ErrorState has changed
/// </summary>
event EventHandler OnErrorStatusChanged;
/// <summary>
/// occurs when Init is completed
/// </summary>
event EventHandler OnInitCompleted;
/// <summary>
/// occurs when the initialization for Measurement is completed
/// </summary>
event EventHandler OnMeasurementInitCompleted;
/// <summary>
/// occurs when the Measurement is completed
/// </summary>
event EventHandler OnMeasurementCompleted;
/// <summary>
/// occurs when the initialization for calibration is completed
/// </summary>
event EventHandler OnCalibInitCompleted;
/// <summary>
/// occurs when the calibration is completed
/// </summary>
event EventHandler OnCalibCompleted;
/// <summary>
/// occurs when meter gets disposed
/// </summary>
event EventHandler OnDisposeCompleted;
#endregion
#region properties
/// <summary>
/// unique meter identification
/// </summary>
String SerialNumber { get; set; }
/// <summary>
/// read-only to see current Process state <see cref="ProcessState" />
/// </summary>
ProcessState ProcessStatus { get; }
/// <summary>
/// the current slot in test-bench
/// </summary>
Int32 Slot { get; set; }
/// <summary>
/// Setup of intermediate update time for measurement updates and overflow detections,
/// has to be calculated depending on flow-rate and nominal diameter (DN)
/// </summary>
Int32 IntermediateUpdateTimeS { get; set; }
/// <summary>
/// Skip the test bench preparation process
/// </summary>
Boolean SkipPreparationForTestBench { get; set; }
/// <summary>
/// Set the current action test
/// </summary>
String CurrentActionText { get; set; }
#endregion
#region method
/// <summary>
/// Read the PcbId from IMeter, if device has no readable PcbId simulate one
/// </summary>
/// <returns></returns>
String GetPcbId();
/// <summary>
/// Open Com ports, try some communication, login
/// </summary>
void ConnectMeter();
/// <summary>
/// Setup up meter from config file. just a workaround for vb6 calls. please do not use if your working with .net
/// </summary>
/// <param name="slot">Slot Number for Test bench</param>
/// <param name="ignoreCorruptedData">don´t send CRC error or telegrams with error flag to caller</param>
/// <param name="useRequest"></param>
/// <param name="useStreaming"></param>
void SetupFromConfigFile(Int32 slot, Boolean ignoreCorruptedData = true, Boolean useRequest = true, Boolean useStreaming = true);
/// <summary>
/// Logout from device
/// </summary>
Boolean Logout();
/// <summary>
/// Start Login with password service
/// </summary>
Boolean Login();
/// <summary>
/// Start Login with out password service and a fixed password
/// </summary>
/// <param name="password">password for login</param>
/// <param name="runImmediately">execute immediately</param>
/// <param name="skipReadMeterFwAndAssignRegisters">skip app readout and register generation to speed up
/// the initial connection process</param>
Boolean Login(String password, Boolean runImmediately = true, Boolean skipReadMeterFwAndAssignRegisters = false);
/// <summary>
/// set up measurement parameter and set meter into test-mode
/// </summary>
void InitMeasurement();
/// <summary>
/// Starting a Measurement
/// Meter must be initialized <see cref="InitMeasurement" />
/// Start to receive record from meter and decode this record into <code>MeasurementRecord</code>
/// <see cref="IMeasurementRecord" />
/// </summary>
[ComVisible(false)]
void StartMeasurement();
/// <summary>
/// Meter must have a active measurement <see cref="StartMeasurement" />
/// Stop receive record from meter and decode record
/// </summary>
void StopMeasurement();
/// <remarks date="2018JAN09" author="drabesch">
/// - simplify the measurement results handling
/// - getting the main measurement of the entire device (combination of all paths)
/// - add MeasurementResult
/// - remove all other methods
/// </remarks>
/// <summary>
/// After a completed measurement , you can grab <see cref="MeasurementResults"/>
/// </summary>
/// <returns>Calculated results</returns>
MeasurementResults GetMainMeasurementResult(Double? refVolume, Double? refTimeS, Boolean intermediateMeasurement = false, MeasurementDirection dir = MeasurementDirection.TakeBoth);
/// <summary>
/// The first measurement is ALWAYS a FlowTestRecord.
/// </summary>
List<MeasurementResults> GetAllMeasurementResults(Double? refVolume, Double? refTimeS,
Boolean intermediateMeasurement = false, Int32? channel = null, MeasurementDirection dir = MeasurementDirection.TakeBoth);
/// <summary>
/// get current state of the running measurement
/// </summary>
/// <param name="onlyChannelNr">leave empty for an aggregate state for all measurements or pass the channel number to check</param>
/// <returns></returns>
MeasurementStates GetMeasurementState(Int32? onlyChannelNr = null );
/// <summary>
/// Request for intermediate measurement state.
/// </summary>
/// <param name="onlyChannelNr"></param>
/// <returns></returns>
Boolean RequestIntermediateMeasurementState(Int32? onlyChannelNr = null);
/// <summary>
/// set up calibration parameter (calibration factor to default) and set meter into calibration mode
/// </summary>
void InitCalibration();
/// <summary>
/// Starting a Calibration
/// Meter must be initialized <see cref="InitCalibration" />
/// Start to receive record from meter, decode and store this record
/// no <see cref="IMeasurementRecord" /> available
/// To finish calibration process run <see cref="StopCalibration" />
/// </summary>
[ComVisible(false)]
void StartCalibration();
/// <summary>
/// Meter must have a active for calibration <see />
/// Stop receive record from meter, decode and store record
/// record will not calculate or store
/// </summary>
void StopCalibration();
/// <summary>
/// Get current state of the running calibration
/// </summary>
/// <returns></returns>
MeasurementStates GetCalibrationState();
/// <summary>
/// Calculate calibration factor for static and flying start / stop
/// Results kept internal and not being saved to meter.
/// if you want to store them on meter use <see cref="SetCalibFactorsAllChannels" />
/// </summary>
/// <param name="refVolumeCm">the reference volume is essential for calculation of calibration factor</param>
/// <param name="refTimeS">the reference time is needed for flying start/stop</param>
/// <param name="reqDeviationPercent">the required deviation to set the scale apart from 0</param>
/// <param name="maxCalibFactorTolerancePercent"> override the default max calibration factor tolerance</param>
void BuildAndCheckCalibFactorsAllChannels(Double refVolumeCm, Double? refTimeS = null, Double reqDeviationPercent = 0.0, Double maxCalibFactorTolerancePercent = 0.0);
/// <summary>
/// Save calculated calibration on meter if no calibration results available an exception occurred
/// </summary>
void SetCalibFactorsAllChannels(Boolean justLog = false);
/// <summary>
/// To control the LCD from meter for status information etc.
/// </summary>
/// <param name="release">if set to true the meter will show his normal screen, if set to false the next parameter will shown in display</param>
/// <param name="textInHex">test shown in LCD in byte array as hex value (0x33,0xFF shows 33FF on screen)</param>
void SetLcdText(Boolean release, Byte[] textInHex);
/// <summary>
/// Sets Display text and update production database
/// </summary>
/// <param name="newState">New ProductionState</param>
/// <param name="webRequest">web logging required per default true, for offline usage set to false</param>
void SetProcessState(DisplayCodes newState, Boolean webRequest = true);
/// <summary>
/// Get last Process State
/// </summary>
DisplayCodes GetLastProcessState();
/// <summary>
/// Add external text to internal log file handling
/// </summary>
/// <param name="text">text to log</param>
void WriteLog(String text);
/// <summary>
/// Enable/Disable Raw record Logging
/// </summary>
/// <param name="on">True = Write Raw record into log/ false = Stop write raw record into log </param>
void LogRawData(Boolean on);
/// <summary>
/// Check if the meter has any errors that can occur on a measurement
/// the error reason has find out in the log files
/// </summary>
/// <returns>false = everything is good, detect at least one error</returns>
Boolean CheckStateAfterMeasurement();
#endregion
/// <summary>
/// Clear all object set up on runtime
/// </summary>
void DisposeMeter();
void TestBenchDispose();
}
}
@@ -123,9 +123,20 @@ namespace ProductionUiCordonel.ProductionProcesses.Actions
Progress = 50;
var genesisStatus = new GenesisStatus();
//TODO Roland: Check this implementation --- START
if (Meter.Region.Equals("EMEA"))
{
genesisStatus.QuiescentCurrent_uA = 119.8;
genesisStatus.EstimatedProductionBatteryLoadPercent = 1.0;
}
else
{
genesisStatus.QuiescentCurrent_uA = 77.7;
genesisStatus.EstimatedProductionBatteryLoadPercent = 1.0;
}
// this calculates all life time values
if (!GenesisStatusHandler.BuildLifeTimeInformation(Meter, genesisStatus))
// this calculates all lifetime values
if (!GenesisStatusHandler.BuildLifeTimeInformation(Meter, genesisStatus, out _))
{
setTxt("Batterie nicht lesbar", true, true);
@@ -142,27 +153,39 @@ namespace ProductionUiCordonel.ProductionProcesses.Actions
return;
}
if (!genesisStatus.UNTStatus)
if (genesisStatus.AlternativeRequiredBatteryLoadPercent != null &&
genesisStatus.DrainedBatteryLoadPercent > genesisStatus.AlternativeRequiredBatteryLoadPercent)
{
if (Meter.Region == "NA")
{
currentProcessState = ProductionProcessState.Error;
}
//
setTxt($"UNT Limit überschritten Limit{genesisStatus.UNTLimit} vs {genesisStatus.DrainedBatteryLoad_uAs}", true, true);
setTxt($"{Meter.Region} limit OK ", true, true);
}
else
{
setTxt($"{Meter.Region} limit überschritten ", true, true);
}
setTxt($"Maximum drained battery load: {genesisStatus.AlternativeRequiredBatteryLoadPercent} % - " +
$" Meter reports drained battery load: {genesisStatus.DrainedBatteryLoad_uAs} %", true, true);
//if (!genesisStatus.UNTStatus)
//{
// if (Meter.Region == "NA")
// {
// currentProcessState = ProductionProcessState.Error;
// }
// //
// setTxt($"UNT Limit überschritten Limit{genesisStatus.UNTLimit} vs {genesisStatus.DrainedBatteryLoad_uAs}", true, true);
//}
//TODO Roland: Check this implementation --- STOP
if (genesisStatus.RemainingLifeTimeYears < 20)
{
if (genesisStatus.DrainedBatteryLoadPercent > 9)
{
currentProcessState = ProductionProcessState.Error;
setTxt("EMEA Limit überschritten Limit 8% vs {genesisStatus.DrainedBatteryLoadPercent}", true, true);
setTxt($"EMEA Limit überschritten Limit 8% vs {genesisStatus.DrainedBatteryLoadPercent}", true, true);
Meter.WriteLog("Batterie über 10% entladen");
@@ -212,7 +235,7 @@ namespace ProductionUiCordonel.ProductionProcesses.Actions
if (currentProcessState != ProductionProcessState.Error)
if (currentProcessState != ProductionProcessState.Error)
{
currentProcessState = ProductionProcessState.Done;
return;
@@ -14,6 +14,7 @@ using System.Windows.Forms;
using System.Windows.Threading;
using Xylem.Common.CommonCore.Configuration;
using Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore;
using Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Consts;
using Xylem.Common.Hardware.WaterMeter.Genesis.Registers;
using Xylem.Common.Logic.SoftwareAccessHelper;
using Button = System.Windows.Controls.Button;
@@ -322,7 +323,7 @@ namespace ProductionUiCordonel.ProductionProcesses.Actions
stm.Start(); // Start polling
DebugMessage(" OK\r\n", true);
Meter.ResetAlarm(GenesisMeter.Alarm.EMPTY_PIPE);
Meter.ResetAlarm(Alarm.EMPTY_PIPE);
Thread.Sleep(5000);
//Meter.WriteRegister("SENSUSRADIO_SYSTEMSTATE", 0x01, true, false);
forcePush();
@@ -6,6 +6,7 @@ using System.Linq;
using System.Threading;
using System.Windows.Controls;
using Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore;
using Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Consts;
using Xylem.Common.Hardware.WaterMeter.Genesis.GenesisFile;
using Xylem.Common.Hardware.WaterMeter.Genesis.Registers;
@@ -165,11 +166,11 @@ namespace ProductionUiCordonel.ProductionProcesses.Actions
}
else
{
Meter.ResetAlarm(GenesisMeter.Alarm.ALL);//(true, new byte[] { 0x00, 0x00, 0x00, 0x01 });
Meter.ResetAlarm(Alarm.ALL);//(true, new byte[] { 0x00, 0x00, 0x00, 0x01 });
Meter.SetLcdText(true, new Byte[] { 0x00, 0x00, 0x00, 0x01 });
Meter.ResetAlarm(GenesisMeter.Alarm.EMPTY_PIPE);//(true, new byte[] { 0x00, 0x00, 0x00, 0x01 });
Meter.ResetAlarm(Alarm.EMPTY_PIPE);//(true, new byte[] { 0x00, 0x00, 0x00, 0x01 });
Meter.WriteRegister("SENSUSRADIO_SystemState", 0xFF);
Meter.Logout();
@@ -253,11 +254,11 @@ namespace ProductionUiCordonel.ProductionProcesses.Actions
}
}
Meter.ResetAlarm(GenesisMeter.Alarm.ALL);//(true, new byte[] { 0x00, 0x00, 0x00, 0x01 });
Meter.ResetAlarm(Alarm.ALL);//(true, new byte[] { 0x00, 0x00, 0x00, 0x01 });
Meter.SetLcdText(true, new Byte[] { 0x00, 0x00, 0x00, 0x01 });
Meter.ResetAlarm(GenesisMeter.Alarm.EMPTY_PIPE);//(true, new byte[] { 0x00, 0x00, 0x00, 0x01 });
Meter.ResetAlarm(Alarm.EMPTY_PIPE);//(true, new byte[] { 0x00, 0x00, 0x00, 0x01 });
if (rebootSucceeded && hasDiffrences.HasValue && !hasDiffrences.Value)
{
@@ -779,154 +779,154 @@ namespace Service.MeterProcessState.Controllers
}
}
[Route("GetProductionSkipAndLifeTimeInfo")]
public async Task<HttpResponseMessage> GetProductionSkipAndLifeTimeInfo(Int32? pcbId = null, Int32? orderNumber = null)
{
try
{
if (!pcbId.HasValue && !orderNumber.HasValue)
{
return Request.CreateResponse(HttpStatusCode.InternalServerError, new ApplicationException("No Argument"));
}
return Request.CreateResponse(HttpStatusCode.OK, await Task.Run(() =>
{
//[Route("GetProductionSkipAndLifeTimeInfo")]
//public async Task<HttpResponseMessage> GetProductionSkipAndLifeTimeInfo(Int32? pcbId = null, Int32? orderNumber = null)
//{
// try
// {
// if (!pcbId.HasValue && !orderNumber.HasValue)
// {
// return Request.CreateResponse(HttpStatusCode.InternalServerError, new ApplicationException("No Argument"));
// }
// return Request.CreateResponse(HttpStatusCode.OK, await Task.Run(() =>
// {
using (var dataAccess = new SqlDataAccess(GlobalConfig.connectionString.Value))
{
StringBuilder sb = new StringBuilder();
// using (var dataAccess = new SqlDataAccess(GlobalConfig.connectionString.Value))
// {
// StringBuilder sb = new StringBuilder();
int DefaultMaxMonthsNaRegion = 6;
int DefaultMaxMonthsEmeaRegion = 3;
Double DefaultRequiredLifeTimeYearsAssembly = 21.0;
Double DefaultRequiredLifeTimeYearsShipping = 20.0;
Double DefaultMaxDrainedBatteryLoadPercent = 10.0;
sb.AppendLine("Select IdendKey, [Value] from ProductionDefaultKeys where IdendKey in (");
sb.AppendLine(" 'DefaultMaxMonthsNaRegion'");
sb.AppendLine(" ,'DefaultMaxMonthsEmeaRegion'");
sb.AppendLine(" ,'DefaultRequiredLifeTimeYearsAssembly'");
sb.AppendLine(" ,'DefaultRequiredLifeTimeYearsShipping'");
sb.AppendLine(" ,'DefaultMaxDrainedBatteryLoadPercent'");
sb.AppendLine(" )");
// int DefaultMaxMonthsNaRegion = 6;
// int DefaultMaxMonthsEmeaRegion = 3;
// Double DefaultRequiredLifeTimeYearsAssembly = 21.0;
// Double DefaultRequiredLifeTimeYearsShipping = 20.0;
// Double DefaultMaxDrainedBatteryLoadPercent = 10.0;
// sb.AppendLine("Select IdendKey, [Value] from ProductionDefaultKeys where IdendKey in (");
// sb.AppendLine(" 'DefaultMaxMonthsNaRegion'");
// sb.AppendLine(" ,'DefaultMaxMonthsEmeaRegion'");
// sb.AppendLine(" ,'DefaultRequiredLifeTimeYearsAssembly'");
// sb.AppendLine(" ,'DefaultRequiredLifeTimeYearsShipping'");
// sb.AppendLine(" ,'DefaultMaxDrainedBatteryLoadPercent'");
// sb.AppendLine(" )");
var dt = dataAccess.ExecuteQuery(sb.ToString());
// var dt = dataAccess.ExecuteQuery(sb.ToString());
foreach (var item in dt.Select())
{
switch (item["IdendKey"].ToString())
{
case "DefaultMaxMonthsNaRegion":
int.TryParse(item["Value"].ToString(), out DefaultMaxMonthsNaRegion);
// foreach (var item in dt.Select())
// {
// switch (item["IdendKey"].ToString())
// {
// case "DefaultMaxMonthsNaRegion":
// int.TryParse(item["Value"].ToString(), out DefaultMaxMonthsNaRegion);
break;
case "DefaultMaxMonthsEmeaRegion":
int.TryParse(item["Value"].ToString(), out DefaultMaxMonthsEmeaRegion);
break;
case "DefaultRequiredLifeTimeYearsAssembly":
double.TryParse(item["Value"].ToString(), out DefaultRequiredLifeTimeYearsAssembly);
break;
case "DefaultRequiredLifeTimeYearsShipping":
double.TryParse(item["Value"].ToString(), out DefaultRequiredLifeTimeYearsShipping);
break;
case "DefaultMaxDrainedBatteryLoadPercent":
double.TryParse(item["Value"].ToString(), out DefaultMaxDrainedBatteryLoadPercent);
break;
default:
break;
}
// break;
// case "DefaultMaxMonthsEmeaRegion":
// int.TryParse(item["Value"].ToString(), out DefaultMaxMonthsEmeaRegion);
// break;
// case "DefaultRequiredLifeTimeYearsAssembly":
// double.TryParse(item["Value"].ToString(), out DefaultRequiredLifeTimeYearsAssembly);
// break;
// case "DefaultRequiredLifeTimeYearsShipping":
// double.TryParse(item["Value"].ToString(), out DefaultRequiredLifeTimeYearsShipping);
// break;
// case "DefaultMaxDrainedBatteryLoadPercent":
// double.TryParse(item["Value"].ToString(), out DefaultMaxDrainedBatteryLoadPercent);
// break;
// default:
// break;
// }
}
sb = new StringBuilder();
// }
// sb = new StringBuilder();
sb.AppendLine($" select [id] ");
sb.AppendLine($" ,[OrderNumber] ");
sb.AppendLine($" ,[PcbId] ");
sb.AppendLine($" ,[SkipRadioParametersCheck] ");
sb.AppendLine($" ,[OverrideFwCheck] ");
sb.AppendLine($" ,[OverrideLutCheck] ");
sb.AppendLine($" ,[RequiredLifeTimeYearsAssembly] ");
sb.AppendLine($" ,[RequiredLifeTimeYearsShipping] ");
sb.AppendLine($" ,[KitronProductionDate] ");
sb.AppendLine($" ,[MaxDrainedBatteryLoadPercent] ");
sb.AppendLine($" ,[MaxStorageMonths] ");
sb.AppendLine($" ,[ApprovalDate] ");
sb.AppendLine($" ,[ApproverName] ");
sb.AppendLine($" ,[ApprovalComment] ");
// sb.AppendLine($" select [id] ");
// sb.AppendLine($" ,[OrderNumber] ");
// sb.AppendLine($" ,[PcbId] ");
// sb.AppendLine($" ,[SkipRadioParametersCheck] ");
// sb.AppendLine($" ,[OverrideFwCheck] ");
// sb.AppendLine($" ,[OverrideLutCheck] ");
// sb.AppendLine($" ,[RequiredLifeTimeYearsAssembly] ");
// sb.AppendLine($" ,[RequiredLifeTimeYearsShipping] ");
// sb.AppendLine($" ,[KitronProductionDate] ");
// sb.AppendLine($" ,[MaxDrainedBatteryLoadPercent] ");
// sb.AppendLine($" ,[MaxStorageMonths] ");
// sb.AppendLine($" ,[ApprovalDate] ");
// sb.AppendLine($" ,[ApproverName] ");
// sb.AppendLine($" ,[ApprovalComment] ");
sb.AppendLine($" FROM [Auftrag].[dbo].[ProductionSkipAndLifeTimeInfo] ");
sb.AppendLine($" where 1 = 1 ");
if (orderNumber.HasValue)
{
sb.AppendLine($" and (OrderNumber = {orderNumber.Value} or OrderNumber is null) ");
}
if (pcbId.HasValue)
{
sb.AppendLine($" and (PcbId = {pcbId.Value} or PcbId is null) ");
}
// sb.AppendLine($" FROM [Auftrag].[dbo].[ProductionSkipAndLifeTimeInfo] ");
// sb.AppendLine($" where 1 = 1 ");
// if (orderNumber.HasValue)
// {
// sb.AppendLine($" and (OrderNumber = {orderNumber.Value} or OrderNumber is null) ");
// }
// if (pcbId.HasValue)
// {
// sb.AppendLine($" and (PcbId = {pcbId.Value} or PcbId is null) ");
// }
// PcbId != null sticht ordernumber , Ordernumbner
//TODO Roland: The defaults should come from a DefaultProductionSkipAndLifeTimeInfo table
// // PcbId != null sticht ordernumber , Ordernumbner
// //TODO Roland: The defaults should come from a DefaultProductionSkipAndLifeTimeInfo table
dt = dataAccess.ExecuteQuery(sb.ToString());
// dt = dataAccess.ExecuteQuery(sb.ToString());
if (dt.Rows.Count == 0)
{
var stat = new GenesisStatus
{
OverrideLutCheck = null,
OverrideFwCheck = null,
SkipRadioParametersCheck = false,
RequiredLifeTimeYearsAssembly = DefaultRequiredLifeTimeYearsAssembly,
RequiredLifeTimeYearsShipping = DefaultRequiredLifeTimeYearsShipping,
MaxDrainedBatteryLoadPercent = DefaultMaxDrainedBatteryLoadPercent,
};
//TODO Roland implement defaults
// get region from order if (Region == "NA")
stat.ProductionDueDate = stat.KitronProductionDate.AddMonths(DefaultMaxMonthsNaRegion);
// else
stat.ProductionDueDate = stat.KitronProductionDate.AddMonths(DefaultMaxMonthsEmeaRegion);
return stat;
}
var ret = new GenesisStatus();
//TODO Roland check for multiple rows take the last?
foreach (var item in dt.Select())
{
try
{
ret.OrderNumber = orderNumber;
ret.PcbId = pcbId.ToString();
ret.SkipRadioParametersCheck = (Boolean)item["SkipRadioParametersCheck"];
ret.OverrideFwCheck = (int)item["OverrideFwCheck"];
ret.OverrideLutCheck = (int)item["OverrideLutCheck"];
//ret.RequiredLifeTimeYearsAssembly = (Double)item["RequiredLifeTimeYearsAssembly"];
//ret.RequiredLifeTimeYearsShipping = (Double)item["RequiredLifeTimeYearsShipping"];
//ret.MaxDrainedBatteryLoadPercent = (Double)item["MaxDrainedBatteryLoadPercent"];
//ret.KitronProductionDate = (DateTime)item["KitronProductionDate"];
var maxStorageMonths = (Int32)item["MaxStorageMonths"];
ret.ProductionDueDate = ret.KitronProductionDate + TimeSpan.FromDays(30.0 * maxStorageMonths);
ret.ApprovalDate = (DateTime)item["ApprovalDate"];
ret.ApproverName = item["ApproverName"].ToString();
ret.ApprovalComment = item["ApprovalComment"].ToString();
}
catch (Exception)
{
}
}
// if (dt.Rows.Count == 0)
// {
// var stat = new GenesisStatus
// {
// OverrideLutCheck = null,
// OverrideFwCheck = null,
// SkipRadioParametersCheck = false,
// RequiredLifeTimeYearsAssembly = DefaultRequiredLifeTimeYearsAssembly,
// RequiredLifeTimeYearsShipping = DefaultRequiredLifeTimeYearsShipping,
// MaxDrainedBatteryLoadPercent = DefaultMaxDrainedBatteryLoadPercent,
// };
// //TODO Roland implement defaults
// // get region from order if (Region == "NA")
// stat.ProductionDueDate = stat.KitronProductionDate.AddMonths(DefaultMaxMonthsNaRegion);
// // else
// stat.ProductionDueDate = stat.KitronProductionDate.AddMonths(DefaultMaxMonthsEmeaRegion);
// return stat;
// }
// var ret = new GenesisStatus();
// //TODO Roland check for multiple rows take the last?
// foreach (var item in dt.Select())
// {
// try
// {
// ret.OrderNumber = orderNumber;
// ret.PcbId = pcbId.ToString();
// ret.SkipRadioParametersCheck = (Boolean)item["SkipRadioParametersCheck"];
// ret.OverrideFwCheck = (int)item["OverrideFwCheck"];
// ret.OverrideLutCheck = (int)item["OverrideLutCheck"];
// //ret.RequiredLifeTimeYearsAssembly = (Double)item["RequiredLifeTimeYearsAssembly"];
// //ret.RequiredLifeTimeYearsShipping = (Double)item["RequiredLifeTimeYearsShipping"];
// //ret.MaxDrainedBatteryLoadPercent = (Double)item["MaxDrainedBatteryLoadPercent"];
// //ret.KitronProductionDate = (DateTime)item["KitronProductionDate"];
// var maxStorageMonths = (Int32)item["MaxStorageMonths"];
// ret.ProductionDueDate = ret.KitronProductionDate + TimeSpan.FromDays(30.0 * maxStorageMonths);
// ret.ApprovalDate = (DateTime)item["ApprovalDate"];
// ret.ApproverName = item["ApproverName"].ToString();
// ret.ApprovalComment = item["ApprovalComment"].ToString();
// }
// catch (Exception)
// {
// }
// }
return ret;
}
// return ret;
// }
}));
}
catch (Exception ex)
{
return Request.CreateResponse(HttpStatusCode.ExpectationFailed, ex.ToString() + "<br >" + ex.InnerException.ToString());
}
}
// }));
// }
// catch (Exception ex)
// {
// return Request.CreateResponse(HttpStatusCode.ExpectationFailed, ex.ToString() + "<br >" + ex.InnerException.ToString());
// }
//}
}
+34 -7
View File
@@ -1,5 +1,4 @@
using Newtonsoft.Json;
using Newtonsoft.Json;
using RestSharp;
using System;
using System.Collections.Generic;
@@ -308,6 +307,36 @@ namespace Xylem.Common.Logic.SoftwareAccessHelper
}
/// <summary>
/// Web request
/// </summary>
/// <param name="url"></param>
/// <param name="httpStatus"></param>
/// <param name="timeoutMs"></param>
/// <returns></returns>
public static String GetRequest(String url, Double timeoutMs, out HttpStatusCode httpStatus)
{
try
{
var httpClient = new HttpClient();
httpClient.DefaultRequestHeaders.Accept.Add(new MediaTypeWithQualityHeaderValue("application/json"));
httpClient.Timeout = TimeSpan.FromMilliseconds(timeoutMs);
var response = httpClient
.GetAsync(url)
.Result;
httpStatus = response.StatusCode;
return response.Content.ReadAsStringAsync().Result;
}
catch (Exception error)
{
httpStatus = HttpStatusCode.ServiceUnavailable;
return error.Message;
}
}
/// <summary>
/// Web request with asynchronous operation
/// </summary>
@@ -347,7 +376,7 @@ namespace Xylem.Common.Logic.SoftwareAccessHelper
{
request.AddJsonBody(json);
}
var r = client.ExecuteAsPost(request, Method.POST.ToString());
return r;
}
@@ -415,8 +444,7 @@ namespace Xylem.Common.Logic.SoftwareAccessHelper
/// <returns></returns>
public static String DeleteRequest(String url, Int32? timeoutMs = null, Dictionary<String, String> header = null, Boolean isRetry = false)
{
Int32 temp;
var ret = DeleteRequestWithError(url, out temp, timeoutMs, header, isRetry);
var ret = DeleteRequestWithError(url, out var temp, timeoutMs, header, isRetry);
if (temp != 200)
{
throw new ApplicationException($"WebRequest Status {temp}");
@@ -479,8 +507,7 @@ namespace Xylem.Common.Logic.SoftwareAccessHelper
/// <returns></returns>
public static String GetRequest(String url, Int32? timeoutMs = null, Dictionary<String, String> header = null, Boolean isRetry = false)
{
Int32 temp;
var ret = GetRequestWithError(url, out temp, timeoutMs, header, isRetry);
var ret = GetRequestWithError(url, out var temp, timeoutMs, header, isRetry);
if (temp != 200)
{
throw new ApplicationException($"WebRequest Status {temp}");
+10 -9
View File
@@ -8,6 +8,7 @@ using System.Threading;
using System.Windows.Forms;
using Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore;
using Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Consts;
using Xylem.Common.Hardware.WaterMeter.Genesis.Registers;
using Xylem.Common.Hardware.WaterMeter.WaterMeterCore;
@@ -139,10 +140,10 @@ namespace Xylem.Common.Ui.GenesisToolBox
{
clbAlarms.ItemCheck -= clbAlarms_ItemCheck;
var cAlarm = _currentGenesis.GetAlarms();
//MessageBox.Show($"Checkalarm EMPTY_PIPE = { _currentGenesis.HasAlarms(GenesisMeter.Alarm.EMPTY_PIPE)}");
//MessageBox.Show($"Checkalarm EMPTY_PIPE = { _currentGenesis.HasAlarms(Alarm.EMPTY_PIPE)}");
clbAlarms.Items.Clear();
foreach (GenesisMeter.Alarm suit in (GenesisMeter.Alarm[])Enum.GetValues(typeof(GenesisMeter.Alarm)))
foreach (Alarm suit in (Alarm[])Enum.GetValues(typeof(Alarm)))
{
clbAlarms.Items.Add(suit, cAlarm.HasFlag(suit));
@@ -169,8 +170,8 @@ namespace Xylem.Common.Ui.GenesisToolBox
{
if (_currentGenesis != null)
{
//_currentGenesis.ResetAlarm(GenesisMeter.Alarm.EMPTY_PIPE | GenesisMeter.Alarm.REBOOT);
var allEnums = ((GenesisMeter.Alarm[])Enum.GetValues(typeof(GenesisMeter.Alarm)));
//_currentGenesis.ResetAlarm(Alarm.EMPTY_PIPE | Alarm.REBOOT);
var allEnums = ((Alarm[])Enum.GetValues(typeof(Alarm)));
if (allEnums.Length > e.Index)
{
_currentGenesis.ResetAlarm(allEnums[e.Index]);
@@ -392,16 +393,16 @@ namespace Xylem.Common.Ui.GenesisToolBox
{
if (_currentGenesis != null && _currentGenesis.IsLoggedOn)
{
_currentGenesis.ResetAlarm(GenesisMeter.Alarm.ALL);
_currentGenesis.ResetAlarm(Alarm.ALL);
}
}
private void finishMeter(GenesisMeter Meter)
{
Meter.ResetAlarm(GenesisMeter.Alarm.ALL);//(true, new byte[] { 0x00, 0x00, 0x00, 0x01 });
Meter.ResetAlarm(Alarm.ALL);//(true, new byte[] { 0x00, 0x00, 0x00, 0x01 });
Meter.SetLcdText(true, new Byte[] { 0x00, 0x00, 0x00, 0x01 });
Meter.ResetAlarm(GenesisMeter.Alarm.EMPTY_PIPE);//(true, new byte[] { 0x00, 0x00, 0x00, 0x01 });
Meter.ResetAlarm(Alarm.EMPTY_PIPE);//(true, new byte[] { 0x00, 0x00, 0x00, 0x01 });
_currentGenesis.WriteRegister(Register.Metrologyasst.PulseMode, 5, true, true);
var useRadio = true;
if (useRadio)
@@ -487,7 +488,7 @@ namespace Xylem.Common.Ui.GenesisToolBox
ReadAlarm("CUSTOMER_AlarmVisualMask", lblAVM, clbAVM);
var cAlarm = _currentGenesis.GetAlarms();
//MessageBox.Show($"Checkalarm EMPTY_PIPE = { _currentGenesis.HasAlarms(GenesisMeter.Alarm.EMPTY_PIPE)}");
//MessageBox.Show($"Checkalarm EMPTY_PIPE = { _currentGenesis.HasAlarms(Alarm.EMPTY_PIPE)}");
Boolean retry = false;
Boolean roland = false;
@@ -495,7 +496,7 @@ namespace Xylem.Common.Ui.GenesisToolBox
if (lblAEM.Text == "00-00-80-53" && lblABM.Text == "00-00-1F-DC" && lblAVM.Text == "00-00-1F-DC")
{
if (cAlarm == GenesisMeter.Alarm.EMPTY_PIPE)
if (cAlarm == Alarm.EMPTY_PIPE)
{
MessageBox.Show("weiter");
}

Some files were not shown because too many files have changed in this diff Show More