branch changing

This commit is contained in:
Stoyan Zlatev
2024-10-07 08:55:21 +02:00
parent d188985f48
commit 2042ffd959
@@ -470,71 +470,6 @@
private Boolean CheckBatteryAndLifeTime(EOLProgressModel eolModel, CordonelRequirements requirements)
{
// Check battery load in percent and compare with requirements for limits for drained battery load
// For the alternative calculation based quiescent current and production supplement this will be used.
// Build message for required versus calculated life time
//ProductionStatus.QuiescentCurrent_uA = ProductionRequirements.QuiescentCurrent_uA;
//ProductionStatus.EstimatedProductionBatteryLoadPercent =
// ProductionRequirements.EstimatedProductionBatteryLoadPercent;
//var threshold = ProductionStatus.AlternativeRequiredBatteryLoadPercent ??
// ProductionRequirements.MaxDrainedBatteryLoadPercentShipping;
//var alternativeCalculation = ProductionStatus.AlternativeRequiredBatteryLoadPercent == null ? "" :
// $"({Resources.StrMsgAlternativeDrainedBatteryCalculation})";
//var batteryLoad = $"{Resources.StrMsgDrainedBatteryAtEol}: " +
// // Actual calculated battery load based on readings from meter
// $"{ProductionStatus.DrainedBatteryLoadPercent:F2} %" +
// $" - {Resources.StrMsgRequirementLimtDrainedBatteryAtEol}: " +
// // Required battery load from standard or special requirement
// $"{threshold:F2} % {alternativeCalculation}";
//eolModel.ProductionStatusDrainedBatteryLoad = ProductionStatus.DrainedBatteryLoadPercent;
//if (ProductionStatus.AlternativeRequiredBatteryLoadPercent != null &&
// ProductionStatus.DrainedBatteryLoadPercent >
// ProductionStatus.AlternativeRequiredBatteryLoadPercent)
//{
// // errorMsg = $"{Resources.StrErrorMsg}: {batteryLoad}";
// eolModel.ProductionStatusBatteryLoadChecked = EOLStatus.FAIL;
// return false; // ExitWithErrorAndUserWindow(errorMsg);
//}
//if (ProductionStatus.DrainedBatteryLoadPercent >
// ProductionRequirements.MaxDrainedBatteryLoadPercentShipping)
//{
// // errorMsg = $"{Resources.StrErrorMsg}: {batteryLoad}";
// eolModel.ProductionStatusBatteryLoadChecked = EOLStatus.FAIL;
// return false; // ExitWithErrorAndUserWindow(errorMsg);
//}
//eolModel.ProductionStatusBatteryLoadChecked = EOLStatus.OK;
//// SuccessMsgDispatcher($"{Resources.StrSuccessMsg}: {batteryLoad}");
//// Build message for required versus calculated life time
//var lifeTime = $"{Resources.StrMsgRemainingLifeTimeAtEol}: " +
// // Actual calculated life time based on readings from meter
// $"{ProductionStatus.RemainingLifeTimeYears:F2} " +
// $"{Resources.StrMsgYears}" +
// $" - {Resources.StrMsgRequiredLifeTimeAtEol}: " +
// // Required life time from special or standard requirement
// $"{ProductionRequirements.RequiredLifeTimeYearsShipping:F2} " +
// $"{Resources.StrMsgYears}";
//// Check required years for shipping
//// EolProgress.ProductionStatusRemainingLifeTime = ProductionStatus.RemainingLifeTimeYears;
//if (ProductionStatus.RemainingLifeTimeYears < ProductionRequirements.RequiredLifeTimeYearsShipping)
//{
// // errorMsg = $"{Resources.StrErrorMsg}: {lifeTime}";
// eolModel.ProductionStatusRemainingLifeTimeChecked = EOLStatus.FAIL;
// return false; // ExitWithErrorAndUserWindow(errorMsg);
//}
//// SuccessMsgDispatcher($"{Resources.StrSuccessMsg}: {lifeTime}");
//eolModel.ProductionStatusRemainingLifeTimeChecked = EOLStatus.OK;
return true;
}