Common: - configuration.json compatibility test and messages
This commit is contained in:
@@ -31,6 +31,16 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.Applications
|
||||
/// </summary>
|
||||
public Int32? AppVersion;
|
||||
|
||||
/// <summary>
|
||||
/// Max supported version of configuration.json for region EMEA.
|
||||
/// </summary>
|
||||
public String InterfaceMaxEmeaVersion;
|
||||
|
||||
/// <summary>
|
||||
/// Max supported version of configuration.json for region NA.
|
||||
/// </summary>
|
||||
public String InterfaceMaxNaVersion;
|
||||
|
||||
/// <summary>
|
||||
/// Get application name
|
||||
/// </summary>
|
||||
|
||||
@@ -1,4 +1,6 @@
|
||||
namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
using System.Linq;
|
||||
|
||||
namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
{
|
||||
using Newtonsoft.Json;
|
||||
using Newtonsoft.Json.Converters;
|
||||
@@ -60,6 +62,15 @@
|
||||
/// <param name="configurationJson"></param>
|
||||
/// <returns></returns>
|
||||
/// <exception cref="Exception"></exception>
|
||||
/// <remarks date="2025-Aug-05" author="Thomas Wiedebusch">
|
||||
/// - AppId from Byte to UInt16 including typecast for Byte[] return. To external, it will be used as Byte
|
||||
/// as before this change. But being able to parse the configuration.json with OPTICALINTERFACE using the
|
||||
/// AppId 256, which exceeds the byte range as this isn't a real application, but will be used to identify
|
||||
/// the interface (configuration.json) version.
|
||||
/// </remarks>
|
||||
/// <remarks date="2025-Aug-07" author="Thomas Wiedebusch">
|
||||
/// - Extract the max supported versions for EMEA and NA to check the supported FW.
|
||||
/// </remarks>
|
||||
public void BuildRegisterList(String configurationJson)
|
||||
{
|
||||
IDictionary<String, AppSection> sections;
|
||||
@@ -80,13 +91,34 @@
|
||||
var appId = sectionKVP.Value.Id;
|
||||
var appName = sectionKVP.Key;
|
||||
var appVersion = sectionKVP.Value.Version.Last;
|
||||
if (appName.Equals("OPTICALINTERFACE"))
|
||||
{
|
||||
var builds = sectionKVP.Value.Builds;
|
||||
var emeaBuilds = builds["emea"];
|
||||
var naBuilds = builds["na"];
|
||||
String maxSupportedEmeaVersion = "";
|
||||
String maxSupportedNaVersion = "";
|
||||
if (emeaBuilds.Count > 0)
|
||||
maxSupportedEmeaVersion = emeaBuilds[emeaBuilds.Count - 1].FW;
|
||||
if (naBuilds.Count > 0)
|
||||
maxSupportedNaVersion = naBuilds[naBuilds.Count - 1].FW;
|
||||
ConfigApplicationDefinitions.Add(new ApplicationDefinition
|
||||
{
|
||||
AppId = appId,
|
||||
AppName = appName,
|
||||
AppVersion = appVersion,
|
||||
InterfaceMaxEmeaVersion = maxSupportedEmeaVersion,
|
||||
InterfaceMaxNaVersion = maxSupportedNaVersion
|
||||
});
|
||||
continue;
|
||||
}
|
||||
|
||||
ConfigApplicationDefinitions.Add(new ApplicationDefinition
|
||||
{
|
||||
AppId = appId,
|
||||
AppName = appName,
|
||||
AppVersion = appVersion
|
||||
});
|
||||
AppVersion = appVersion,
|
||||
});
|
||||
|
||||
var section = sectionKVP.Value;
|
||||
|
||||
@@ -125,7 +157,7 @@
|
||||
AppName = appName,
|
||||
DataType = GetType(detail.Type),
|
||||
Default = values?.Default is Int64 d ? d : default(Int64?),
|
||||
IsAvailable = default(Boolean),
|
||||
IsAvailable = false,
|
||||
Maximum = values?.Maximum is Int64 max ? max : default(Int64?),
|
||||
Minimum = values?.Minimum is Int64 min ? min : default(Int64?),
|
||||
RegAddressInApp = regId,
|
||||
|
||||
@@ -229,11 +229,26 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
}
|
||||
|
||||
/// <inheritdoc />
|
||||
public String InterfaceVersion {
|
||||
public String InterfaceVersion
|
||||
{
|
||||
protected set;
|
||||
get;
|
||||
} = "?";
|
||||
|
||||
/// <inheritdoc />
|
||||
public String InterfaceMaxFwVersion
|
||||
{
|
||||
protected set;
|
||||
get;
|
||||
}
|
||||
|
||||
/// <inheritdoc />
|
||||
public Boolean InterfaceSupportsFwVersion
|
||||
{
|
||||
protected set;
|
||||
get;
|
||||
}
|
||||
|
||||
/// <inheritdoc />
|
||||
public String Region
|
||||
{
|
||||
@@ -241,7 +256,8 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
}
|
||||
|
||||
/// <inheritdoc />
|
||||
public String MeterLength {
|
||||
public String MeterLength
|
||||
{
|
||||
set;
|
||||
get;
|
||||
} = "?";
|
||||
@@ -1287,7 +1303,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
|
||||
/// <summary>
|
||||
/// Building the FW Version string and the hexadecimal version out of 2 bytes of data or from an
|
||||
/// input string like "11.07" or "R1.1.07" or "B1.1.07" or "1.3.0B" or "9.0.2D".
|
||||
/// input string like "1107", "11.07", "R1.1.07", "B1.1.07", "1.3.0B" or "9.0.2D".
|
||||
///
|
||||
/// REASON: FLEXNETVERSION is one application which does not follow the same rule of decimal numbers.
|
||||
/// Instead, it uses hexadecimal digits.
|
||||
@@ -1649,6 +1665,11 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
InstalledFwVersion = 0;
|
||||
MeterAppListVersion.Clear();
|
||||
|
||||
CheckRegionSizeLutCrc();
|
||||
|
||||
UInt32 interfaceMaxEmeaVersion = 0;
|
||||
UInt32 interfaceMaxNaVersion = 0;
|
||||
|
||||
// Get all existing applications from meter register dictionary
|
||||
foreach (var meterApp in ConfigApplications.OrderBy(o => o.AppId))
|
||||
{
|
||||
@@ -1657,8 +1678,16 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
{
|
||||
// Build the interface id for information of compatibility from FW to configuration.json
|
||||
InterfaceVersion = BuildFwVersionStringFromDec(meterApp.AppVersion);
|
||||
// Build the max supported versions for EMEA and NA to check the supported FW
|
||||
if (Region.Equals("EMEA"))
|
||||
InterfaceMaxFwVersion = BuildFlexnetFwVersion(out interfaceMaxEmeaVersion,
|
||||
meterApp.InterfaceMaxEmeaVersion);
|
||||
if (Region.Equals("NA"))
|
||||
InterfaceMaxFwVersion = BuildFlexnetFwVersion(out interfaceMaxNaVersion,
|
||||
meterApp.InterfaceMaxNaVersion);
|
||||
continue;
|
||||
}
|
||||
|
||||
UInt32 readFwVersion = 0;
|
||||
UInt16 readFwCrc = 0;
|
||||
var isInstalled = false;
|
||||
@@ -1677,7 +1706,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
if (meterApp.AppName.Equals("FLEXNETVERSION"))
|
||||
{
|
||||
// msb and lsb are swapped during communication
|
||||
FwVersion = BuildFlexnetFwVersion(out readFwVersion, null, readFwVersionBytes[1],
|
||||
FwVersion = BuildFlexnetFwVersion(out readFwVersion, null, readFwVersionBytes[1],
|
||||
readFwVersionBytes[0]);
|
||||
versionString = FwVersion;
|
||||
InstalledFwVersion = readFwVersion;
|
||||
@@ -1724,8 +1753,6 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
});
|
||||
}
|
||||
|
||||
CheckRegionSizeLutCrc();
|
||||
|
||||
//read metrology upgrade permission
|
||||
MetrologyUpgradePermission = RegisterConverter.ByteArrayToValue<Byte>(
|
||||
ReadRegister(Register.System.MetrologyUpgradePermission));
|
||||
@@ -1789,6 +1816,20 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
Logger.Info($"Slot:{Slot} - Meter size: {MeterSize}");
|
||||
Logger.Info($"Slot:{Slot} - Upgrade permission: {MetrologyUpgradePermission:X2}");
|
||||
Logger.Info($"Slot:{Slot} - Interface (configuration.json) version: {InterfaceVersion}");
|
||||
|
||||
if (InstalledFwVersion != null &&
|
||||
((Region.Equals("EMEA") && interfaceMaxEmeaVersion >= InstalledFwVersion) ||
|
||||
(Region.Equals("NA") && interfaceMaxNaVersion >= InstalledFwVersion)))
|
||||
{
|
||||
InterfaceSupportsFwVersion = true;
|
||||
Logger.Info($"Slot:{Slot} - Interface supports FW version: {FwVersion}");
|
||||
}
|
||||
else
|
||||
{
|
||||
InterfaceSupportsFwVersion = false;
|
||||
Logger.Warn($"Slot:{Slot} - Interface does not support FW version! Installed FW version: {FwVersion}, " +
|
||||
$"Interface supports max FW version: {InterfaceMaxFwVersion}");
|
||||
}
|
||||
|
||||
// initial list of ALL registers defined in configuration.json
|
||||
var tempConfigRegisters = ConfigRegister.MeterRegisterDic.ToList();
|
||||
@@ -2745,7 +2786,7 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
private void PostRegisterRead(RegisterDefinition reg, Byte[] value)
|
||||
{
|
||||
var avoidLoggingRegisterNameList = Register.GetAvoidLogRegisters();
|
||||
|
||||
|
||||
if (Configuration.UseRegisterWatchService && avoidLoggingRegisterNameList.All(regName => regName != reg.GetIdent()))
|
||||
{
|
||||
try
|
||||
|
||||
@@ -95,13 +95,30 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// This is the version Id of the interface "configuration.json".
|
||||
/// This is the version of the interface "configuration.json".
|
||||
/// </summary>
|
||||
String InterfaceVersion
|
||||
{
|
||||
get;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// This is the max supported firmware version of the interface "configuration.json".
|
||||
/// It is the max version for a specific region.
|
||||
/// </summary>
|
||||
String InterfaceMaxFwVersion
|
||||
{
|
||||
get;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// This FW version is supported by the interface "configuration.json".
|
||||
/// </summary>
|
||||
Boolean InterfaceSupportsFwVersion
|
||||
{
|
||||
get;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Length of the meter.
|
||||
/// </summary>
|
||||
|
||||
@@ -447,6 +447,9 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.MockGenesis
|
||||
/// <remarks date="2025-Jun-19" author="Thomas Wiedebusch">
|
||||
/// - Avoid overwriting of list combined with valid register dictionary.
|
||||
/// </remarks>
|
||||
/// <remarks date="2025-Aug-07" author="Thomas Wiedebusch">
|
||||
/// - Check interface compatibility.
|
||||
/// </remarks>
|
||||
protected override void ReadMeterFirmwareAndAssignRegisters()
|
||||
{
|
||||
// Avoid overwriting of list if this already exits
|
||||
@@ -470,9 +473,26 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.MockGenesis
|
||||
return;
|
||||
}
|
||||
|
||||
UInt32 interfaceMaxEmeaVersion = 0;
|
||||
UInt32 interfaceMaxNaVersion = 0;
|
||||
var strInterfaceMaxEmeaVersion = "";
|
||||
var strInterfaceMaxNaVersion = "";
|
||||
|
||||
//Get all existing applications from meter register dictionary
|
||||
foreach (var meterApp in ConfigApplications.OrderBy(o => o.AppId))
|
||||
{
|
||||
if (meterApp.AppName.Equals("OPTICALINTERFACE"))
|
||||
{
|
||||
// Build the interface id for information of compatibility from FW to configuration.json
|
||||
InterfaceVersion = BuildFwVersionStringFromDec(meterApp.AppVersion);
|
||||
// Build the max supported versions for EMEA and NA to check the supported FW
|
||||
strInterfaceMaxEmeaVersion = BuildFlexnetFwVersion(out interfaceMaxEmeaVersion,
|
||||
meterApp.InterfaceMaxEmeaVersion);
|
||||
strInterfaceMaxNaVersion = BuildFlexnetFwVersion(out interfaceMaxNaVersion,
|
||||
meterApp.InterfaceMaxNaVersion);
|
||||
continue;
|
||||
}
|
||||
|
||||
// Take all listed config apps even if not installed
|
||||
var app = new MeterApplications
|
||||
{
|
||||
@@ -530,6 +550,28 @@ namespace Xylem.Common.Hardware.WaterMeter.Genesis.MockGenesis
|
||||
Region = "EMEA";
|
||||
}
|
||||
}
|
||||
|
||||
// Assign the max supported FW version of the interface depending on the region
|
||||
if (Region.Equals("EMEA"))
|
||||
InterfaceMaxFwVersion = strInterfaceMaxEmeaVersion;
|
||||
if (Region.Equals("NA"))
|
||||
InterfaceMaxFwVersion = strInterfaceMaxNaVersion;
|
||||
|
||||
// Check if the interface supports the FW
|
||||
if (InstalledFwVersion != null &&
|
||||
((Region.Equals("EMEA") && interfaceMaxEmeaVersion >= InstalledFwVersion) ||
|
||||
(Region.Equals("NA") && interfaceMaxNaVersion >= InstalledFwVersion)))
|
||||
{
|
||||
InterfaceSupportsFwVersion = true;
|
||||
Logger.Info($"Slot:{Slot} - Interface supports FW version: {FwVersion}");
|
||||
}
|
||||
else
|
||||
{
|
||||
InterfaceSupportsFwVersion = false;
|
||||
Logger.Warn($"Slot:{Slot} - Interface does not support FW version! Installed FW version: {FwVersion}, " +
|
||||
$"Interface supports max FW version: {InterfaceMaxFwVersion}");
|
||||
}
|
||||
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
|
||||
Reference in New Issue
Block a user