ProductionUiCordonel: - alarm reset after reboot
This commit is contained in:
@@ -34,7 +34,7 @@
|
||||
|
||||
|
||||
<appSettings>
|
||||
<add key="Mode" value="2" /> <!--1 = EOL ; 2 = Picking-->
|
||||
<add key="Mode" value="1" /> <!--1 = EOL ; 2 = Picking-->
|
||||
<add key="SirtComport433" value="14" /> <!--Individual for Thomas 14-->
|
||||
<add key="SirtComport868" value="15" /> <!--Individual for Thomas 15-->
|
||||
<add key="SirtBoxNr" value="2" /> <!--Roland and Thomas, box for development, box at shipping station is 1-->
|
||||
|
||||
+1
-2
@@ -326,8 +326,7 @@ namespace Xylem.Common.Production.ProductionUiCordonel.ProductionProcesses.EolPr
|
||||
}
|
||||
|
||||
SuccessMsgDispatcher(Resources.StrSuccessMsgRadioInCustomerMode);
|
||||
SuccessMsgDispatcher(Resources.StrSuccessMsgRadioAlarmsReset);
|
||||
|
||||
|
||||
// Skip radio check by requirement
|
||||
if (skipRadioCheck)
|
||||
{
|
||||
|
||||
+60
-20
@@ -1,6 +1,7 @@
|
||||
using System;
|
||||
using LaaPackages.Features.Cordonel.Models;
|
||||
using Xylem.Common.CommonCore.Consts;
|
||||
using Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Consts;
|
||||
using Xylem.Common.Hardware.WaterMeter.Genesis.GenesisFile;
|
||||
using Xylem.Common.Hardware.WaterMeter.Genesis.Registers;
|
||||
using Xylem.Common.Hardware.WaterMeter.Genesis.Registers.DataTypes;
|
||||
@@ -42,6 +43,9 @@ namespace Xylem.Common.Production.ProductionUiCordonel.ProductionProcesses.EolPr
|
||||
/// <remarks date="2025-Apr-03" author="Thomas Wiedebusch">
|
||||
/// - Moved setting of time and reset counters from <see cref="CheckFinalParametrization"/> to here.
|
||||
/// </remarks>
|
||||
/// <remarks date="2025-Jul-10" author="Thomas Wiedebusch/Roland Drabesch">
|
||||
/// - Reset alarms in customer app and radio app and check it for success.
|
||||
/// </remarks>
|
||||
public override StatusReturn ExecuteProcess()
|
||||
{
|
||||
// Uncheck executed process to leave the result open needed for retries
|
||||
@@ -104,33 +108,69 @@ namespace Xylem.Common.Production.ProductionUiCordonel.ProductionProcesses.EolPr
|
||||
var rawSeconds = RegisterConverter.ValueToByteArray(teaTime.UtcNowToSecondsSince2000);
|
||||
var timerSetup = new ProgrammingParameters("SYSTEM_CalendarSeconds", rawSeconds,
|
||||
ProgrammingSource.ProgramInternal);
|
||||
// This is the manufacturing date of the Cordonel
|
||||
var irdaMfgDate = new ProgrammingParameters("IRDA_MfgDate", rawSeconds,
|
||||
ProgrammingSource.ProgramInternal);
|
||||
// Reset reboot counter
|
||||
var nullRebootCtr = new ProgrammingParameters("CUSTOMER_RebootCount", new Byte[] { 0x00 },
|
||||
ProgrammingSource.ProgramInternal);
|
||||
var retValBol = WriteRegisterLogAndProcessCtr(timerSetup);
|
||||
retValBol &= WriteRegisterLogAndProcessCtr(irdaMfgDate);
|
||||
retValBol &= WriteRegisterLogAndProcessCtr(nullRebootCtr);
|
||||
if (Meter.RadioFrequencyMhz != null)
|
||||
{
|
||||
// Reset periodic log reset counter
|
||||
var periodicLogResetCtr = new ProgrammingParameters("PERIODICLOG_ResetCounter", new Byte[] { 0x00 },
|
||||
ProgrammingSource.ProgramInternal);
|
||||
retValBol &= WriteRegisterLogAndProcessCtr(periodicLogResetCtr);
|
||||
// Reset sensus radio reset counter
|
||||
var sensusRadioResetCtr = new ProgrammingParameters("SENSUSRADIO_ResetCounter", new Byte[] { 0x00 },
|
||||
ProgrammingSource.ProgramInternal);
|
||||
retValBol &= WriteRegisterLogAndProcessCtr(sensusRadioResetCtr);
|
||||
}
|
||||
|
||||
if (!retValBol)
|
||||
// This is the manufacturing date of the Cordonel
|
||||
retValBol &= WriteRegisterLogAndProcessCtr(new ProgrammingParameters("IRDA_MfgDate", rawSeconds,
|
||||
ProgrammingSource.ProgramInternal));
|
||||
// Reset reboot counter
|
||||
retValBol &= WriteRegisterLogAndProcessCtr(new ProgrammingParameters("CUSTOMER_RebootCount", new Byte[] { 0x00 },
|
||||
ProgrammingSource.ProgramInternal));
|
||||
// Reset alarms Customer
|
||||
retValBol &= WriteRegisterLogAndProcessCtr(new ProgrammingParameters("CUSTOMER_TriggerAlarmCancel",
|
||||
new Byte[] { 0xFF, 0xFF, 0xFF, 0xFF }, ProgrammingSource.ProgramInternal));
|
||||
ActualProcessProgress++;
|
||||
|
||||
// Read back CUSTOMER_TriggerAlarmCancel and ignore empty pipe
|
||||
var readBackCustomerAlarmCancel =
|
||||
RegisterConverter.ByteArrayToValue<UInt32>(Meter.ReadRegister("CUSTOMER_TriggerAlarmCancel"));
|
||||
|
||||
if (!retValBol || readBackCustomerAlarmCancel != 0)
|
||||
{
|
||||
ErrorMsgDispatcher(Resources.StrErrorMsgAlarmReset);
|
||||
EolProgress.RebootDoneChecked = EOLStatus.FAIL;
|
||||
return StatusReturn.Failed;
|
||||
}
|
||||
|
||||
if (Meter.RadioFrequencyMhz != null)
|
||||
{
|
||||
// Reset periodic log reset counter
|
||||
retValBol &= WriteRegisterLogAndProcessCtr(new ProgrammingParameters("PERIODICLOG_ResetCounter",
|
||||
new Byte[] { 0x00 }, ProgrammingSource.ProgramInternal));
|
||||
|
||||
// Reset main and extended alarm mask
|
||||
retValBol &= WriteRegisterLogAndProcessCtr(new ProgrammingParameters("SENSUSRADIO_MainAlarmMask",
|
||||
new Byte[] { 0 }, ProgrammingSource.ProgramInternal));
|
||||
retValBol &= WriteRegisterLogAndProcessCtr(new ProgrammingParameters("SENSUSRADIO_ExtendedAlarmMask",
|
||||
new Byte[] { 0 }, ProgrammingSource.ProgramInternal));
|
||||
|
||||
// System state sensus radio to 0xFF for re-initialize
|
||||
retValBol &= WriteRegisterLogAndProcessCtr(new ProgrammingParameters("SENSUSRADIO_SystemState",
|
||||
new Byte[] { 0xFF }, ProgrammingSource.ProgramInternal));
|
||||
|
||||
// Read back alarm masks
|
||||
var mainAlarmMask =
|
||||
RegisterConverter.ByteArrayToValue<Byte>(Meter.ReadRegister("SENSUSRADIO_MainAlarmMask"));
|
||||
var extendedAlarmMask =
|
||||
RegisterConverter.ByteArrayToValue<Byte>(Meter.ReadRegister("SENSUSRADIO_ExtendedAlarmMask"));
|
||||
var finalRadioSystemState =
|
||||
RegisterConverter.ByteArrayToValue<Byte>(Meter.ReadRegister("SENSUSRADIO_SystemState"));
|
||||
|
||||
// Reset sensus radio reset counter
|
||||
var sensusRadioResetCtr = new ProgrammingParameters("SENSUSRADIO_ResetCounter", new Byte[] { 0x00 },
|
||||
ProgrammingSource.ProgramInternal);
|
||||
retValBol &= WriteRegisterLogAndProcessCtr(sensusRadioResetCtr);
|
||||
|
||||
if (!retValBol || mainAlarmMask != 0 || extendedAlarmMask !=0 || finalRadioSystemState != 0x02)
|
||||
{
|
||||
ErrorMsgDispatcher(Resources.StrErrorMsgAlarmReset);
|
||||
EolProgress.RebootDoneChecked = EOLStatus.FAIL;
|
||||
return StatusReturn.Failed;
|
||||
}
|
||||
|
||||
}
|
||||
|
||||
SuccessMsgDispatcher(Resources.StrSuccessMsgAlarmReset);
|
||||
EolProgress.RebootDoneChecked = EOLStatus.OK;
|
||||
return StatusReturn.Okay;
|
||||
}
|
||||
|
||||
@@ -312,6 +312,15 @@ namespace Xylem.Common.Production.ProductionUiCordonel.Properties {
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to ERROR: Failed to reset alarms.
|
||||
/// </summary>
|
||||
internal static string StrErrorMsgAlarmReset {
|
||||
get {
|
||||
return ResourceManager.GetString("StrErrorMsgAlarmReset", resourceCulture);
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to ERROR: At least one wrong or missing App.
|
||||
/// </summary>
|
||||
@@ -1914,6 +1923,15 @@ namespace Xylem.Common.Production.ProductionUiCordonel.Properties {
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to Success: Alarms successfully reset.
|
||||
/// </summary>
|
||||
internal static string StrSuccessMsgAlarmReset {
|
||||
get {
|
||||
return ResourceManager.GetString("StrSuccessMsgAlarmReset", resourceCulture);
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to Success: Cordonel Calibration process execution reported .
|
||||
/// </summary>
|
||||
@@ -2004,15 +2022,6 @@ namespace Xylem.Common.Production.ProductionUiCordonel.Properties {
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to Success: Radio alarms successfully reset.
|
||||
/// </summary>
|
||||
internal static string StrSuccessMsgRadioAlarmsReset {
|
||||
get {
|
||||
return ResourceManager.GetString("StrSuccessMsgRadioAlarmsReset", resourceCulture);
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Looks up a localized string similar to Radio successfully switched to customer mode.
|
||||
/// </summary>
|
||||
|
||||
@@ -520,8 +520,11 @@
|
||||
<data name="StrStartMsgProcess" xml:space="preserve">
|
||||
<value>Start</value>
|
||||
</data>
|
||||
<data name="StrSuccessMsgRadioAlarmsReset" xml:space="preserve">
|
||||
<value>Erfolg: Funkalarme erfolgreich gelöscht</value>
|
||||
<data name="StrSuccessMsgAlarmReset" xml:space="preserve">
|
||||
<value>Erfolg: Alarme erfolgreich zurückgesetzt</value>
|
||||
</data>
|
||||
<data name="StrErrorMsgAlarmReset" xml:space="preserve">
|
||||
<value>FEHLER: Alarme konnten nicht zurückgesetzt werden</value>
|
||||
</data>
|
||||
<data name="StrSuccessMsgRadioInCustomerMode" xml:space="preserve">
|
||||
<value>Erfolg: Funk efolgreich in Kundenmodus geschaltet</value>
|
||||
|
||||
@@ -520,8 +520,11 @@
|
||||
<data name="StrStartMsgProcess" xml:space="preserve">
|
||||
<value>Start</value>
|
||||
</data>
|
||||
<data name="StrSuccessMsgRadioAlarmsReset" xml:space="preserve">
|
||||
<value>Success: Radio alarms successfully reset</value>
|
||||
<data name="StrSuccessMsgAlarmReset" xml:space="preserve">
|
||||
<value>Success: Alarms successfully reset</value>
|
||||
</data>
|
||||
<data name="StrErrorMsgAlarmReset" xml:space="preserve">
|
||||
<value>ERROR: Failed to reset alarms</value>
|
||||
</data>
|
||||
<data name="StrSuccessMsgRadioInCustomerMode" xml:space="preserve">
|
||||
<value>Radio successfully switched to customer mode</value>
|
||||
|
||||
Reference in New Issue
Block a user