ProductionUiCordonel: - alarm reset after reboot

This commit is contained in:
Thomas Wiedebusch
2025-07-10 14:02:27 +02:00
parent fdffdf8a08
commit 060782197d
6 changed files with 90 additions and 36 deletions
@@ -34,7 +34,7 @@
<appSettings>
<add key="Mode" value="2" /> <!--1 = EOL ; 2 = Picking-->
<add key="Mode" value="1" /> <!--1 = EOL ; 2 = Picking-->
<add key="SirtComport433" value="14" /> <!--Individual for Thomas 14-->
<add key="SirtComport868" value="15" /> <!--Individual for Thomas 15-->
<add key="SirtBoxNr" value="2" /> <!--Roland and Thomas, box for development, box at shipping station is 1-->
@@ -326,8 +326,7 @@ namespace Xylem.Common.Production.ProductionUiCordonel.ProductionProcesses.EolPr
}
SuccessMsgDispatcher(Resources.StrSuccessMsgRadioInCustomerMode);
SuccessMsgDispatcher(Resources.StrSuccessMsgRadioAlarmsReset);
// Skip radio check by requirement
if (skipRadioCheck)
{
@@ -1,6 +1,7 @@
using System;
using LaaPackages.Features.Cordonel.Models;
using Xylem.Common.CommonCore.Consts;
using Xylem.Common.Hardware.WaterMeter.Genesis.GenesisCore.Consts;
using Xylem.Common.Hardware.WaterMeter.Genesis.GenesisFile;
using Xylem.Common.Hardware.WaterMeter.Genesis.Registers;
using Xylem.Common.Hardware.WaterMeter.Genesis.Registers.DataTypes;
@@ -42,6 +43,9 @@ namespace Xylem.Common.Production.ProductionUiCordonel.ProductionProcesses.EolPr
/// <remarks date="2025-Apr-03" author="Thomas Wiedebusch">
/// - Moved setting of time and reset counters from <see cref="CheckFinalParametrization"/> to here.
/// </remarks>
/// <remarks date="2025-Jul-10" author="Thomas Wiedebusch/Roland Drabesch">
/// - Reset alarms in customer app and radio app and check it for success.
/// </remarks>
public override StatusReturn ExecuteProcess()
{
// Uncheck executed process to leave the result open needed for retries
@@ -104,33 +108,69 @@ namespace Xylem.Common.Production.ProductionUiCordonel.ProductionProcesses.EolPr
var rawSeconds = RegisterConverter.ValueToByteArray(teaTime.UtcNowToSecondsSince2000);
var timerSetup = new ProgrammingParameters("SYSTEM_CalendarSeconds", rawSeconds,
ProgrammingSource.ProgramInternal);
// This is the manufacturing date of the Cordonel
var irdaMfgDate = new ProgrammingParameters("IRDA_MfgDate", rawSeconds,
ProgrammingSource.ProgramInternal);
// Reset reboot counter
var nullRebootCtr = new ProgrammingParameters("CUSTOMER_RebootCount", new Byte[] { 0x00 },
ProgrammingSource.ProgramInternal);
var retValBol = WriteRegisterLogAndProcessCtr(timerSetup);
retValBol &= WriteRegisterLogAndProcessCtr(irdaMfgDate);
retValBol &= WriteRegisterLogAndProcessCtr(nullRebootCtr);
if (Meter.RadioFrequencyMhz != null)
{
// Reset periodic log reset counter
var periodicLogResetCtr = new ProgrammingParameters("PERIODICLOG_ResetCounter", new Byte[] { 0x00 },
ProgrammingSource.ProgramInternal);
retValBol &= WriteRegisterLogAndProcessCtr(periodicLogResetCtr);
// Reset sensus radio reset counter
var sensusRadioResetCtr = new ProgrammingParameters("SENSUSRADIO_ResetCounter", new Byte[] { 0x00 },
ProgrammingSource.ProgramInternal);
retValBol &= WriteRegisterLogAndProcessCtr(sensusRadioResetCtr);
}
if (!retValBol)
// This is the manufacturing date of the Cordonel
retValBol &= WriteRegisterLogAndProcessCtr(new ProgrammingParameters("IRDA_MfgDate", rawSeconds,
ProgrammingSource.ProgramInternal));
// Reset reboot counter
retValBol &= WriteRegisterLogAndProcessCtr(new ProgrammingParameters("CUSTOMER_RebootCount", new Byte[] { 0x00 },
ProgrammingSource.ProgramInternal));
// Reset alarms Customer
retValBol &= WriteRegisterLogAndProcessCtr(new ProgrammingParameters("CUSTOMER_TriggerAlarmCancel",
new Byte[] { 0xFF, 0xFF, 0xFF, 0xFF }, ProgrammingSource.ProgramInternal));
ActualProcessProgress++;
// Read back CUSTOMER_TriggerAlarmCancel and ignore empty pipe
var readBackCustomerAlarmCancel =
RegisterConverter.ByteArrayToValue<UInt32>(Meter.ReadRegister("CUSTOMER_TriggerAlarmCancel"));
if (!retValBol || readBackCustomerAlarmCancel != 0)
{
ErrorMsgDispatcher(Resources.StrErrorMsgAlarmReset);
EolProgress.RebootDoneChecked = EOLStatus.FAIL;
return StatusReturn.Failed;
}
if (Meter.RadioFrequencyMhz != null)
{
// Reset periodic log reset counter
retValBol &= WriteRegisterLogAndProcessCtr(new ProgrammingParameters("PERIODICLOG_ResetCounter",
new Byte[] { 0x00 }, ProgrammingSource.ProgramInternal));
// Reset main and extended alarm mask
retValBol &= WriteRegisterLogAndProcessCtr(new ProgrammingParameters("SENSUSRADIO_MainAlarmMask",
new Byte[] { 0 }, ProgrammingSource.ProgramInternal));
retValBol &= WriteRegisterLogAndProcessCtr(new ProgrammingParameters("SENSUSRADIO_ExtendedAlarmMask",
new Byte[] { 0 }, ProgrammingSource.ProgramInternal));
// System state sensus radio to 0xFF for re-initialize
retValBol &= WriteRegisterLogAndProcessCtr(new ProgrammingParameters("SENSUSRADIO_SystemState",
new Byte[] { 0xFF }, ProgrammingSource.ProgramInternal));
// Read back alarm masks
var mainAlarmMask =
RegisterConverter.ByteArrayToValue<Byte>(Meter.ReadRegister("SENSUSRADIO_MainAlarmMask"));
var extendedAlarmMask =
RegisterConverter.ByteArrayToValue<Byte>(Meter.ReadRegister("SENSUSRADIO_ExtendedAlarmMask"));
var finalRadioSystemState =
RegisterConverter.ByteArrayToValue<Byte>(Meter.ReadRegister("SENSUSRADIO_SystemState"));
// Reset sensus radio reset counter
var sensusRadioResetCtr = new ProgrammingParameters("SENSUSRADIO_ResetCounter", new Byte[] { 0x00 },
ProgrammingSource.ProgramInternal);
retValBol &= WriteRegisterLogAndProcessCtr(sensusRadioResetCtr);
if (!retValBol || mainAlarmMask != 0 || extendedAlarmMask !=0 || finalRadioSystemState != 0x02)
{
ErrorMsgDispatcher(Resources.StrErrorMsgAlarmReset);
EolProgress.RebootDoneChecked = EOLStatus.FAIL;
return StatusReturn.Failed;
}
}
SuccessMsgDispatcher(Resources.StrSuccessMsgAlarmReset);
EolProgress.RebootDoneChecked = EOLStatus.OK;
return StatusReturn.Okay;
}
@@ -312,6 +312,15 @@ namespace Xylem.Common.Production.ProductionUiCordonel.Properties {
}
}
/// <summary>
/// Looks up a localized string similar to ERROR: Failed to reset alarms.
/// </summary>
internal static string StrErrorMsgAlarmReset {
get {
return ResourceManager.GetString("StrErrorMsgAlarmReset", resourceCulture);
}
}
/// <summary>
/// Looks up a localized string similar to ERROR: At least one wrong or missing App.
/// </summary>
@@ -1914,6 +1923,15 @@ namespace Xylem.Common.Production.ProductionUiCordonel.Properties {
}
}
/// <summary>
/// Looks up a localized string similar to Success: Alarms successfully reset.
/// </summary>
internal static string StrSuccessMsgAlarmReset {
get {
return ResourceManager.GetString("StrSuccessMsgAlarmReset", resourceCulture);
}
}
/// <summary>
/// Looks up a localized string similar to Success: Cordonel Calibration process execution reported .
/// </summary>
@@ -2004,15 +2022,6 @@ namespace Xylem.Common.Production.ProductionUiCordonel.Properties {
}
}
/// <summary>
/// Looks up a localized string similar to Success: Radio alarms successfully reset.
/// </summary>
internal static string StrSuccessMsgRadioAlarmsReset {
get {
return ResourceManager.GetString("StrSuccessMsgRadioAlarmsReset", resourceCulture);
}
}
/// <summary>
/// Looks up a localized string similar to Radio successfully switched to customer mode.
/// </summary>
@@ -520,8 +520,11 @@
<data name="StrStartMsgProcess" xml:space="preserve">
<value>Start</value>
</data>
<data name="StrSuccessMsgRadioAlarmsReset" xml:space="preserve">
<value>Erfolg: Funkalarme erfolgreich gelöscht</value>
<data name="StrSuccessMsgAlarmReset" xml:space="preserve">
<value>Erfolg: Alarme erfolgreich zurückgesetzt</value>
</data>
<data name="StrErrorMsgAlarmReset" xml:space="preserve">
<value>FEHLER: Alarme konnten nicht zurückgesetzt werden</value>
</data>
<data name="StrSuccessMsgRadioInCustomerMode" xml:space="preserve">
<value>Erfolg: Funk efolgreich in Kundenmodus geschaltet</value>
@@ -520,8 +520,11 @@
<data name="StrStartMsgProcess" xml:space="preserve">
<value>Start</value>
</data>
<data name="StrSuccessMsgRadioAlarmsReset" xml:space="preserve">
<value>Success: Radio alarms successfully reset</value>
<data name="StrSuccessMsgAlarmReset" xml:space="preserve">
<value>Success: Alarms successfully reset</value>
</data>
<data name="StrErrorMsgAlarmReset" xml:space="preserve">
<value>ERROR: Failed to reset alarms</value>
</data>
<data name="StrSuccessMsgRadioInCustomerMode" xml:space="preserve">
<value>Radio successfully switched to customer mode</value>